Filtern
Dokumenttyp
- Zeitschriftenartikel (6)
- Beitrag zu einem Tagungsband (6)
- Vortrag (2)
- Handbuch (1)
- Posterpräsentation (1)
Schlagworte
- CO2 quality (3)
- Impurities (3)
- Pipeline network (3)
- Recommendations (3)
- Whole-chain CCS scenario (3)
- Beton (2)
- Civil engineering (2)
- Corrosion (2)
- Non-destrucive testing (2)
- Procedure (2)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (6)
- 8 Zerstörungsfreie Prüfung (6)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (6)
- 7.6 Korrosion und Korrosionsschutz (5)
- 5 Werkstofftechnik (3)
- 5.1 Materialographie, Fraktographie und Alterung technischer Werkstoffe (3)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
- 1.8 Umweltanalytik (1)
- 6 Materialchemie (1)
MYCN is a transcription factor that is aberrantly expressed in many tumor types and is often correlated with poor patient prognosis. Recently, several lines of evidence pointed to the fact that oncogenic activation of MYC family proteins is concomitant with reprogramming of tumor cells to cope with an enhanced need for metabolites during cell growth. These adaptions are driven by the ability of MYC proteins to act as transcriptional amplifiers in a tissue-of-origin specific manner. Here, we describe the effects of MYCN overexpression on metabolic reprogramming in neuroblastoma cells. Ectopic expression of MYCN induced a glycolytic switch that was concomitant with enhanced sensitivity towards 2-deoxyglucose, an inhibitor of glycolysis. Moreover, global metabolic profiling revealed extensive alterations in the cellular metabolome resulting from overexpression of MYCN. Limited supply with either of the two main carbon sources, glucose or glutamine, resulted in distinct shifts in steady-state metabolite levels and significant changes in glutathione metabolism. Interestingly, interference with glutamine-glutamate conversion preferentially blocked proliferation of MYCN overexpressing cells, when glutamine levels were reduced. Thus, our study uncovered MYCN induction and nutrient levels as important metabolic master switches in neuroblastoma cells and identified critical nodes that restrict tumor cell proliferation.
The field of non-destructive testing of civil structures (NDT-CE) has been continuously growing. Due to the complexity and diversity of civil constructions as well as the heterogeneity of concrete, specific standards or guidelines for the application of modern NDT-CE are still missing. The development of individual solutions is the current approach, which is just as challenging as it is common for NDT-CE.
With the increasing development and commercialization of NDT-CE technology, the group of practitioners is growing. To ensure a good level of quality in the industry, it appears necessary to establish adequate means.
Naturally, the performance of NDT-CE methods regarding a specific application is strongly dependent on choosing the most suitable inspection technique and applying it correctly, generally referred to as the inspection procedure in the field of NDT. There are well-defined guidelines regarding procedure documentation and handling in many fields of NDT (e.g. nuclear, aerospace or automotive) according to the high importance of procedures in assuring a successful and reliable application. For a long time, this has not always been the case with NDT-CE, which is still considered a unique discipline of NDT. Part of the reason for that might be the young development state of NDTCE, the heterogeneity of building materials like concrete, timber or masonry as a material and the diversity of civil structures. In consequence, NDT-CE procedure development is considered challenging.
Among other aspects, addressed in the subcommittee on Quality Assurance (UA-QS) within the committee for NDT-CE of the German Society for Nondestructive Testing (DGZfP), part of its work aims at establishing an adequate basis for NDT-CE procedure development. While some of the highly developed approaches from other industries are taken into consideration, they need to be analyzed regarding their suitability for NDT-CE and adapted accordingly. For a procedure to be as defined as possible, it needs to contain sufficient information, such as the scope and limitations regarding material, geometry and condition of the test object, inspection parameters, calibration, data acquisition, analysis criteria as well as requirements regarding the inspection personnel.
For a successful implementation in the field, it is important to define the specific procedure as precisely as possible. Despite the necessity of a great amount of information to be included, the procedure needs to be suitable for efficient field application.
The UA-QS is developing a guideline for NDT-CE procedures suitable for application in this field of NDT to ensure correct and reproducible application. To demonstrate and evaluate this concept, specific examples of procedures are also produced. In particular, the UA-QS has developed a procedure for the detection and positioning of tendon ducts using Ground Penetrating Radar (GPR). This procedure is tested regarding the practical applicability in a roundrobin on a defined type of reference test block.
The process of ensuring reliability of NDT applications contains various aspects, such as determining the performance and probability of success, the uncertainty in measurement, the provision of clear and functional procedures and ensuring the correct application accordingly. Test specimens have become powerful elements in supporting many of these aspects. Within the committee for NDT in Civil Engineering (NDT-CE) of the German Society for Nondestructive Testing (DGZfP), the subcommittee on Quality Assurance (UA-QS) therefore addresses the design and the integration of test specimens in the quality assurance process. Depending on the specific purpose, the requirements on test specimens can vary significantly based on the defined simulated scenario. The most prominent purposes of test specimens might be seen in providing references for inspection systems in regard to function control, calibration and validation. Further aspects can be parametric studies, basic investigation of physical principles related to NDT or a simplified and therefore comprehensive demonstration of inspection concepts (e.g. for teaching purposes). The specific purpose of a test specimen dictates the requirements regarding its conception, including the exact design, the material or the fabrication accuracy and the conditioning. In the development of a general guideline by the UA-QS for application-specific procedures and their validation, the use of test specimens is addressed and specific concepts for the design of test specimens are made. This includes the analysis of the measurement process regarding any given application, deriving an adequate calibration approach for it and designing test specimens (calibration specimens) accordingly. Furthermore, it includes the validation of the procedure taking into account all conditions related to the specific application in the field. The validation requires a statistically sufficient number of trials. Thorough evaluation of each trial can only be established if the ground-truth is known. Therefore, test specimens providing a realistic but controlled simulation of the inspection problem are valuable and indispensable elements in the validation process. The requirement of being fully realistic will often not be possible to fulfill due to practical restrictions. Any aspect that cannot be included in the simulation realistically needs to be simulated conservatively. This again, requires a sufficient understanding of the inspection principle and technique to ensure conservativeness. Among other quality-assurance-related aspects, the UA-QS establishes concepts and guidelines regarding sound and efficient approaches for the specific purposes of test specimens. This subcommittee brings together representatives of different Groups along the entire value chain of NDT-CE, including researchers, practitioners, manufacturers and clients. They all work together in establishing a common understanding and level of quality assurance in the industry.
Stahlbetontragwerke sind eine wichtige Konstruktionsweise im Bauwesen und ein wachsendes Anwendungsfeld für die Zerstörungsfreie Prüfung (ZfP).
Zur Sicherung der Tragsicherheit, strukturellen Integrität, Bestimmung von Geometrien und zur Detektion konstruktiver Elemente wie z.B. Bewehrung, Verankerungen und Spannkanälen besitzen zerstörungsfreie Prüfverfahren in diesem Bereich inzwischen große Relevanz. Durch den bislang erreichten Fortschritt in der Forschung und Entwicklung haben moderne akustische und elektromagnetische Verfahren eine beachtliche Leistungsfähigkeit erreicht. Von Geräteherstellern sind diese in kommerziellen Produktserien umgesetzt worden und finden eine zunehmend breite Anwendung in der Praxis. In einigen anderen Anwendungsgebieten, in denen die ZfP bereits fester Bestandteil von Überwachungen ist, wie z.B. im Maschinenbau und insbesondere in der Kerntechnik und der Luftfahrt, existieren umfangreiche Qualitätssicherungssysteme für die konforme Anwendung und zuverlässige Einbeziehung der ZfP. Dem relativ jungen Entwicklungsstadium moderner ZfP für Stahlbetonbauteile entsprechend müssen solche Konzepte im Bauwesen erst noch entwickelt bzw. implementiert werden.
Dementsprechend hat sich der Unterausschuss Qualitätssicherung (UA- S) des Fachausschusses ZfP im Bauwesen (ZfPBau) die Definition und Verbesserung der Qualität von ZfP-Anwendungen sowie insbesondere die verfahrensunabhängige Standardisierung von Prüfprozeduren und statistische Absicherung der Prüfergebnisse zum Ziel gemacht.
Die aktuellen Arbeitsfelder beinhalten die Entwicklung praxisgerechter Konzepte für Prüfprozeduren und deren Erprobung in einem Ringversuch sowie die Konzeption von Testkörpern hinsichtlich unterschiedlicher Aspekte wie Parameterstudien, Validierung, Kalibrierung und Simulation. Dabei werden Ansätze anderer Branchen durchaus einbezogen, die Anpassung an die spezifischen Bedürfnisse und Gegebenheiten des Bauwesens wird jedoch als wesentlich angesehen und stellt somit eine wichtige Vorgabe dar.
Da die Tätigkeiten nicht auf einzelne Verfahren begrenzt sind, müssen generelle Vorgehensweisen entwickelt werden, die sich auf die jeweiligen Verfahren konkretisieren lassen. Der Vortrag gibt hierzu erste Einblicke in die Arbeit des Ausschusses.
MACC1 is a prognostic and predictive metastasis biomarker for more than 20 solid Cancer entities. However, its role in cancer metabolism is not sufficiently explored. Here, we report on how MACC1 impacts the use of glucose, glutamine, lactate, pyruvate and fatty acids and show the comprehensive analysis of MACC1-driven metabolic networks. We analyzed concentrationdependent changes in nutrient use, nutrient depletion, metabolic tracing employing 13C-labeled substrates, and in vivo studies. We found that MACC1 permits numerous effects on cancer
metabolism. Most of those effects increased nutrient uptake. Furthermore, MACC1 alters metabolic pathways by affecting metabolite production or turnover from metabolic substrates. MACC1 supports use of glucose, glutamine and pyruvate via their increased depletion or altered distribution within metabolic pathways. In summary, we demonstrate that MACC1 is an important regulator of metabolism in cancer cells.
Metal nanoparticles have a substantial impact across diferent felds of science, such as photochemistry, energy conversion, and medicine. Among the commonly used nanoparticles, silver nanoparticles are of special interest due to their antibacterial properties and applications in sensing and catalysis. However, many of the methods used to synthesize silver nanoparticles often do not result in well-defned products, the main obstacles being high polydispersity or a lack of particle size tunability. We describe an automated approach to on-demand synthesis of adjustable particles with mean radii of 3 and 5 nm using the polyol route. The polyol process is a promising route for silver nanoparticles e.g., to be used as reference materials. We characterised the as-synthesized nanoparticles using small-angle X-ray scattering, dynamic light scattering and further methods, showing that automated synthesis can yield colloids with reproducible and tuneable properties.