Filtern
Dokumenttyp
- Buchkapitel (2)
Sprache
- Englisch (2) (entfernen)
Schlagworte
- Adiabatic compression (1)
- Adjustable pressure rise time (1)
- Burn out safety (1)
- Endurance testing (1)
- High pressure oxygen (1)
- Ignition source (1)
- Incident research (1)
- Innovation in OPST facility (1)
- Lubricant (1)
- Nonmetallic material (1)
Organisationseinheit der BAM
Cylinder valves for oxygen service that meet the standard DIN EN ISO 10297 should be safe, if properly handled by the user. In the last few years, however, the number of incidents with oxygen valves that has been reported to Federal Institute for Materials Research and Testing (BAM) has increased. According to the incident reports, incorrect handling can be ruled out. People were seriously injured and in most cases, the causes of these incidents were not clear. Very often, such incidents occurred during opening and closing of the valves. Therefore, the technical-scientific community has put the existing test methods for type testing more and more into question. Besides other mandatory tests, the above-mentioned standard allows to perform the endurance test with air or with nitrogen. This is appropriate for all other gases but not for oxygen. Up to now, this test does not consider the fact that cylinder valves also contain nonmetallic seat materials and lubricants that may react with oxygen in a dangerous way. Because of this unsatisfactory situation, BAM initiated a research project to perform endurance testing of cylinder valves for oxygen service much more practice related with oxygen. This test simulates very well real life situations when the cylinder valve is opened or closed. The first part of this project was the development of a new oxygen operated endurance tester in accordance with DIN EN ISO 10297. In a second part, endurance testing of valves with air and with oxygen was performed and the results were compared. In addition, another mandatory test of the standard, the oxygen pressure surge test was carried out on new valves and on valves that had undergone endurance tests with air or oxygen, to see the influence on the burn-out safety of such pre-stressed valves. This paper presents the main results of the project. The findings clearly speak for implementing the oxygen endurance test not only to DIN EN ISO 10297 but also to various other standards to increase the burn-out safety of oxygen cylinder valves.
The Oxygen Pressure Surge Test (OPST) is considered to be best practice for evaluating the burn out safety of plant components and testing the compatibility of nonmetallic materials for oxygen service. Nevertheless, there are only a few laboratories worldwide performing the OPST. The Federal Institute for Materials Research and Testing (BAM) already operates oxygen pressure surge test facilities with maximum OPST pressures of 450 bar.
However, to ensure technical innovation and to enhance research and development, the decision was made to develop a new and large-scale oxygen pressure surge test facility. Due to the size and the high potential impact energies, the test facility is located outside of Berlin at BAM Test Site for Technical Safety (TTS), where large scale testing is carried out. In addition to an intended maximum OPST pressure of 750 bar, there is the possibility of testing industrial equipment with large inner volumes and diameters. The new quick opening valve constitutes the core of the system and was developed by BAM. It allows to perform tests with the standardized pressure rise times of 15 ms to 20 ms or with adjustable pressure rise times at higher or lower values. As a result, it is possible to provide customized test parameters for specific practical applications as well as research projects.
This presentation shows the status quo of this unique test facility, its performance, its technical specifications, and its new possibilities for research and development for a long term enhancement of burn out safety in oxygen application.