Filtern
Dokumenttyp
Referierte Publikation
- ja (3) (entfernen)
Schlagworte
- Acrylamide (1)
- Cadmium (1)
- Certified reference material (1)
- Cocoa (1)
- Food analysis (1)
- Hydrogen peroxide oxidation (1)
- IC (1)
- KFT (1)
- Optimized Monier-Williams method (1)
- Quality assurance (1)
Organisationseinheit der BAM
Since 1 January 2019 a maximum content of 0.6 mg kg−1 cadmium (Cd) in cocoa powder sold to the final consumer or as an ingredient in sweetened cocoa powder sold to the final consumer (drinking chocolate) is set by the Commission Regulation (EU) No. 488/2014. Monitoring compliance with the specified limit value requires analytical measuring methods and reference materials for quality control. However, suitable certified reference materials intended for quality assurance and quality control purposes are still lacking. Therefore, three cocoa reference materials (ERM®-BD513, ERM®-514 and ERM®-515) were developed according to the requirements of ISO 17034 and the recommendations of ISO Guide 35. The whole process of reference material development, including material preparation, assessment of homogeneity and stability, characterisation and value assignment is presented. The assignment of the certified mass fractions was based upon an interlaboratory comparison study involving 19 expert laboratories for Cd and 12 laboratories for acrylamide. The certified mass fractions and expanded uncertainties (k = 2) of the reference materials were (0.181 ± 0.009) mg kg−1 Cd (ERM®-BD513), (0.541 ± 0.024) mg kg−1 Cd (ERM®-BD514) and (0.690 ± 0.029) mg kg−1 Cd (ERM®-BD515). Acrylamide contents are given for information.
Sulfur dioxide (SO2) or sulfites are the most common preservatives used in winemaking. The level of total SO2 is subject to regulation. Currently, the regulatory determination of total SO2 (including sulfites) is done by the optimized Monier–Williams (OMW) method, which includes time-consuming distillation and titration steps. This paper describes the development and application of an alternative, rapid, straightforward, and reliable method for the determination of total sulfite in wine. In this method, a simple oxidation step using alkaline hydrogen peroxide (H2O2) solution is followed by ion chromatographic (IC) analysis of sulfate coupled with conductometric detection. Thirteen wines were analyzed in order to compare the in-sample oxidation method with the OMW-procedure. A t-test revealed satisfying compliance regarding sample preparation, i.e., alkaline H2O2 treatment and acidic distillation (OMW method). Comparable results were also obtained between IC analysis and acid/base titration. Our results indicate that the novel method (limit of quantification: 4 mg SO2 L-1) is well suited for the cost-efficient monitoring of regulatory limits.