Filtern
Dokumenttyp
Sprache
- Englisch (9)
Referierte Publikation
- ja (9) (entfernen)
Schlagworte
- Gas chromatography (3)
- Analysis (1)
- Breath alcohol (1)
- Certified reference material (1)
- Certified reference materials (CRM) (1)
- DDT breakdown (1)
- Derivatisation (1)
- Ethanol in water (1)
- Extraction (1)
- Extraction efficiency (1)
Due to the utilisation of 1,1,2-trichlorotrifluoroethane (CFE) as extraction solvent the IR-spectrometric determination of total petrol hydrocarbon (TPH) in soil according to ISO/TR 11046 has been replaced by gas chromatography/flame ionisation detection (GC/FID) after extraction with a halogen-free solvent according to ISO/DIS 16703:2001. The results obtained with both methods by field laboratories in three proficiency testing (PT) rounds are compared. The consensus means obtained with GC/FID are typically 10%-20% (ranging between 0% and 25%) higher than those found with IR-spectroscopy. On the contrary, coefficients of variation (CV) are roughly double in case of GC/FID and are briefly discussed against the background of the Horwitz equation.
Determination of pentachlorphenol (PCP) in waste wood - method comparison by a collaborative trial
(2002)
Two independently developed and validated procedures for the determination of pentachlorophenol (PCP) in waste wood were compared by means of a collaborative trial. Both methods foresee quantification of PCP by gas chromatography (GC-ECD) after acetylation and differ with regard to the use of methanol or toluene/sulphuric acid, respectively, as solvent in the sonication extraction step. Test samples with established analyte homogeneity were prepared from a ground real life starting material. A total of 23 participating laboratories with experience in wood preservative analysis were instructed to apply both methods to three levels of content in the range of 0.520 mg PCP/kg. In case of the toluene/sulphuric acid extraction, lower recoveries and higher interlaboratory dispersion of results at the higher PCP contents were observed. Seen against the background of the Horwitz equation a reproducibility standard deviation of not, vert, similar19% for the methanol extraction at the 4.5 mg/kg level meets the requirement for a sound analytical method. Thus, the sonication extraction procedure with methanol has been annexed as a reference method to the German waste wood regulation.
The capabilities of National Metrology Institutes (NMIsthose which are members of the Comité Consultatif pour la Quantité de Matière (CCQM)of the CIPM) and selected outside "expert" laboratories to quantitate (C4H9)3Sn+ (TBT) in a prepared marine sediment were assessed. This exercise was sanctioned by the 7th CCQM meeting, April 46, 2001, as an activity of the Inorganic Analysis Working Group and was jointly piloted by the Institute for National Measurement Standards of the National Research Council of Canada (NRC) and the Laboratory of the Government Chemist (LGC), UK. A total of 11 laboratories submitted results (7 NMIs, and 4 external labs). Two external laboratories utilized a standard calibration approach based on a natural abundance TBT standard, whereas all NMIs relied upon isotope dilution mass spectrometry for quantitation. For this purpose, a species specific 117Sn-enriched TBT standard was supplied by the LGC. No sample preparation methodology was prescribed by the piloting laboratories and, by consequence, a variety of approaches was adopted by the participants, including mechanical shaking, sonication, accelerated solvent extraction, microwave assisted extraction and heating in combination with Grignard derivatization, ethylation and direct sampling. Detection techniques included ICPMS (with GC and HPLC sample introduction), GCMS, GCAED and GCFPD. Recovery of TBT from a control standard (NRCC CRM PACS-2 marine sediment) averaged 93.5±2.4% (n=14). Results for the pilot material averaged 0.680±0.015 µmol kg1 (n=14; 80.7±1.8 µg kg1) with a median value of 0.676 µmol kg1. Overall, performance was substantially better than state-of-the-art expectations and the satisfactory agreement amongst participants permitted scheduling of a follow-up Key comparison for TBT (K-28), a Pilot intercomparison for DBT (P-43), and certification of the test sediment for TBT content and its release as a new Certified Reference Material (HIPA-1) with a TBT content of 0.679±0.089 µmol kg1 (expanded uncertainty, k=2, as Sn) (80.5±10.6 µg kg1). Electronic Supplementary Material Supplementary material is available in the online version of this article at http://dx.doi.org/10.1007/s00216-003-2016-9.
The 2-year international joint project HYCREF (Contract-No. G6RD-CT-2002-00854), funded by the European Commission in the 5th Framework programme, aimed to develop methods to prepare homogenous and stable water-, soil- and waste reference materials contaminated with mineral oil hydrocarbons and to test certify the mineral oil content by gas chromatographic methods. As mineral oil products are important sources for environmental contaminations, appropriate reference materials certified by using the new gas chromatographic methods (soil: ISO/FDIS 16703, waste: prEN 14039 and KW/04, water: ISO 9377-2) are highly needed. Additional to the HYCREF-results presented in part Imineral contaminated soilsthis second paper gives an overview of the feasibility study for the preparation and test certification of three waste reference materials (offshore marine sediment, building material and industrial waste). The following specifications, which had been defined in the project work plan, were reached successfully: uncertainty of the mineral oil content resulting from the certification exercise ≤ 5% and a between-bottle inhomogeneity of ≤ 3%. All three materials have been evaluated for long- and short term stability. They contain different levels and types of mineral oil and cover the full application range of ISO/FDIS 16703 and prEN 14039 (10010,000 mg/kg). The expanded uncertainties U cert of the three materials are about 6%. In this way, they are comparable to ERM®-CC015a (U cert=7.1%, mineral oil in a river sediment) and are suited to close the present gap of commercially available CRM for mineral oil determination in waste.
Ethanol/water solutions as certified reference materials for breath alcohol analyzer calibration
(2010)
The Federal Institute for Materials Research and Testing (BAM), Germany, has issued a series of large volume ethanol in water certified reference materials (CRMs), primarily developed for the calibration of evidential breath alcohol analyzers in Germany. The certified parameter is the ethanol mass concentration at 20 °C. When used in a wet bath simulator, the solutions deliver gas samples that meet the requirements set by the Organization of Legal Metrology for calibration of breathalyzers. The materials were prepared gravimetrically by spiking of ethanol into water in single 5 L units. A complete uncertainty budget for the preparation process has been established. The purity of the commercial ethanol stock solution was identified to be the main source of uncertainty. For stability and homogeneity measurements and for the verification of the gravimetric mass concentration of the CRMs, a robust high-precision gas chromatography, with flame-ionization detection method for ethanol determination in aqueous samples was developed and validated. The good performance of this method has been demonstrated in several international comparisons organized by the Consultative Committee for Amount of Substance-Metrology in Chemistry at the International Bureau of Weights and Measures.
KEY COMPARISON
At the October 2005 CCQM Organic Analysis Working Group Meeting (IRMM, Belgium), the decision was made to proceed with a Key Comparison study (CCQM-K47) addressing the calibration function for the determination of volatile organic compounds (VOCs) used for water quality monitoring. This was coordinated by CENAM and NIST. Benzene, o-xylene, m-xylene and p-xylene were chosen as representative VOCs. The solvent of choice was methanol.
Key Comparison CCQM-K47 demonstrated the capabilities of participating NMIs to identify and measure the four target VOCs in a calibration solution using GC-based methods. The measurement challenges in CCQM-K47, such as avoiding volatility loss, achieving adequate chromatographic resolution and isolating potential interferences, are typical of those required for value-assigning volatile reference materials. Participants achieving comparable measurements for all four VOCs in this Key Comparison should be capable of providing reference materials and measurements for VOCs in solutions when present at concentration levels greater than 10 µg/g.
Commercially available linear alkylbenzenesulfonates (LASs) are a mixture of various homologues and isomers, leading to 20 major species. In this work we investigated the commercial product by liquid chromatography-solid phase extraction-nuclear magnetic resonance spectroscopy-mass spectrometry (LC-SPE-NMR/MS). The commercial product was separated into 17 fractions by liquid chromatography (LC). After chromatographic separation, 5% of the flow was split to a mass spectrometer (MS) while 95% was send to post-column solid phase extraction cartridges for enrichment of the analytes (LC-SPE). After elution from the SPE-cartridges a NMR-spectrometer equipped with a cryo-probe was used for the characterisation of the different LASs species. For the first time H-1-1D and H-H-COSY spectra for 14 LASs species out of 20 major isomers are presented, whereas the 6 remaining species are detected as mixtures in 3 H-1-1D and H-H-COSY spectra. These data were used to correlate the chromatographic retention of the LASs isomers to the substitution pattern of the alkyl chain.