Filtern
Erscheinungsjahr
- 2019 (3) (entfernen)
Dokumenttyp
Sprache
- Englisch (3)
Referierte Publikation
- ja (3)
Schlagworte
- Core-shell nanoparticles (1)
- Geomembranes (1)
- Ionic liquid (1)
- Landfill (1)
- Landfill lining (1)
- Quantitative XPS (1)
- T-SEM (1)
- ToF-SIMS (1)
- Transmission function (1)
- XPS (1)
Organisationseinheit der BAM
An approach to achieve 'zero leakage' is discussed with respect to experience in Germany, where strict regulations for landfill lining and capping Systems have been developed and issued because of large environmental Problems related to landfills that accumulated in the 1970s and 1980s. Using a thick, high-quality high-density Polyethylene (HDPE) geomembrane (GM) that is installed free of residual waves and wrinkles in intimate contact with a compacted clay liner or geosynthetic clay liner of very low permeability, by a qualified, experienced, well-equipped and properly third-party-controlled installer, and which is protected by heavy protection layers designed with respect to the long-term performance of the GM may result in a liner or capping system of practically no leakage. This is demonstrated by analysing results of measurements obtained from permanently installed leak-detection Systems in combination with HDPE GMs. The survey was based on 32 German landfills with 1.276.500 m² of installed GMs.
The uncertainty of measurement in quantitative XPS analysis can be reduced by using a calibrated spectrometer transmission function T (E), which is usually determined by taking spectra from Au, Ag, Cu and Ge elemental reference materials. However, this approach is quite time-consuming due to required sample preparation steps like sputter cleaning etc., and the relatively big number of samples to be measured. This contribution proposes the use of the ionic liquids [C2C1im][NTf2] and [C3C1im][NTf2] as reference materials for a determination of T(E). These multi-elemental samples deliver five intensive photoemission peaks, F 1s, O 1s, N 1s, C 1s and S 2p, in an energy window from 160 eV to 700 eV which is of specific interest for applications of quantitative XPS for surface chemical analysis of soft matter, one of the major applications of XPS.
Core–shell nanoparticles (CSNPs) have become indispensable in various industrial applications. However, their real internal structure usually deviates from an ideal core–shell structure. To control how the particles perform with regard to their specific applications, characterization techniques are required that can distinguish an ideal from a nonideal morphology. In this work, we investigated poly(tetrafluoroethylene)–poly(methyl methacrylate) (PTFE–PMMA) and poly(tetrafluoroethylene)–polystyrene (PTFE–PS) polymer CSNPs with a constant core diameter (45 nm) but varying shell thicknesses (4–50 nm). As confirmed by transmission scanning electron microscopy (T-SEM), the shell completely covers the core for the PTFE–PMMA nanoparticles, while the encapsulation of the core by the shell material is incomplete for the PTFE–PS nanoparticles. X-ray photoelectron spectroscopy (XPS) was applied to determine the shell thickness of the nanoparticles. The software SESSA v2.0 was used to analyze the intensities of the elastic peaks, and the QUASES software package was employed to evaluate the shape of the inelastic background in the XPS survey spectra. For the first time, nanoparticle shell thicknesses are presented, which are exclusively based on the analysis of the XPS inelastic background. Furthermore, principal component analysis (PCA)-assisted time-of-flight secondary-ion mass spectrometry (ToF-SIMS) of the PTFE–PS nanoparticle sample set revealed a systematic variation among the samples and, thus, confirmed the incomplete encapsulation of the core by the shell material. As opposed to that, no variation is observed in the PCA score plots of the PTFE–PMMA nanoparticle sample set. Consequently, the complete coverage of the core by the shell material is proved by ToF-SIMS with a certainty that cannot be achieved by XPS and T-SEM.