Sulfate attack constitutes a major risk of chemical aggression for concrete and other building materials. Mainly structures exposed to sewage waters and sulfate rich soils are affected. The measurement of sulfate ingress is important for damage assessment previous to repair works and for quality assurance of the effectiveness of protecting coatings or during concrete removal.
Laser induced breakdown spectroscopy is introduced for the quantitative measurement of sulfur contents in building materials, providing detailed depth profiles and imaging element distributions with 1 mm spatial resolution. Detailed statistical evaluation is possible due to the spatial resolution and the fast measurement of the method. Practical applications of the method for damage assessment are demonstrated for three different sewage plants.
Laser-induced breakdown spectroscopy has been employed for the investigation of the sulfur and chlorine content of building materials. Both, chloride and sulfate ions are major damaging species affecting the stability and lifetime of a structure. Chlorine and sulfur are mostly detected in the VUV and the NIR. In case of building materials the main elements like calcium or iron have many strong spectral lines over the whole spectral range, so that trace elements can only be detected in spectral windows unaffected from these lines. With regard to a preferably simply, robust against dust and vibrations and portable setup only the NIR spectral features are used for civil engineering applications.
Most detectors, mainly CCD cameras have rapidly decreasing quantum efficiency in the NIR. Also the quantum efficiency of the photocathode of CCD-Detectors with image intensifier is decreasing in the NIR. Different CCD-detectors were tested with respect to high quantum efficiency and high dynamic range, which is necessary for simultaneous detection of weak spectral lines from trace elements and intense spectral lines from main elements.
The measurements are made on reference samples consisting of cement, hydrated cement, cement mortar and concrete with well-defined amounts of the trace elements. Experimental conditions are chosen for an optimum intensity of the trace element spectral lines. The detector systems are compared by limit of detections and the signal to noise ratio.
Laser-induced breakdown spectroscopy has been used for quantitative measurement of trace elements, e.g. sulfur and chlorine, in concrete. Chloride and sulfate ions have a large effect on the durability of concrete structures, and quantitative measurement is important for condition assessment and quality assurance. Concrete is a highly heterogeneous material in composition and grain-size distribution, i.e. the spatial distribution of elements. Calibration plots were determined by use of laboratory-made reference samples consisting of pressings of cement powder, hydrated cement, cement mortar, and concrete, in which the heterogeneity of the material is increasing because of the aggregates. Coarse aggregate and cement paste are distinguishable by the intensity of the Ca spectral lines. More advanced evaluation is necessary to account for the effect of the fine aggregate. The three series of reference samples enable systematic study of the effects of heterogeneity on spectral intensity, signal fluctuation, uncertainty, and limits of detection. Spatially resolved measurements and many spectra enable statistical evaluation of the data. The heterogeneity has an effect on measurement of the sulfur and chlorine content, because both occur mainly in the cement matrix. Critical chloride concentrations are approximately 0.04% (m/m). The chlorine spectral line at 837.6 nm is evaluated. The natural sulfur content of concrete is approximately 0.1% (m/m). The spectral line at 921.3 nm is evaluated. One future application may be simultaneous determination of the amount of damaging trace elements and the cement content of the concrete.
The applicability of pulse phase thermography (PPT) for the investigation of structures is studied systematically on concrete test specimens and on a plastered sandstone column. In the test specimens, voids and delaminations are implemented in different depths and with different sizes, modelling real voids, honeycombing and debonding. Delaminations of plaster in concrete and masonry and behind tiles on concrete are investigated. PPT is based on the frequency analysis of the cooling down process of actively heated surfaces. Therefore, it is contactless and thus completely non-destructive (if overheating of the surface is prevented), fast and allows the inspection of large surface areas. The interpretation of amplitude and phase images gives semi-quantitative information about the observed defects. The phase images provide a deeper probing up to 1015 cm in relation to the interpretation of the thermograms and to the amplitude images. In addition, the influence of surface inhomogeneities and non-uniform heating is reduced.