Filtern
Dokumenttyp
- Beitrag zu einem Sammelband (16)
- Zeitschriftenartikel (11)
- Beitrag zu einem Tagungsband (8)
- Vortrag (4)
- Posterpräsentation (4)
Schlagworte
- LIBS (12)
- Beton (8)
- Concrete (8)
- Zerstörungsfreie Prüfung im Bauwesen (5)
- Chloride (4)
- Laser-induced breakdown spectroscopy (3)
- Sulphate (3)
- Voids (3)
- Alkali-Kieselsäure Reaktion (2)
- Building materials (2)
Sulfate attack constitutes a major risk of chemical aggression for concrete and other building materials. Mainly structures exposed to sewage waters and sulfate rich soils are affected. The measurement of sulfate ingress is important for damage assessment previous to repair works and for quality assurance of the effectiveness of protecting coatings or during concrete removal.
Laser induced breakdown spectroscopy is introduced for the quantitative measurement of sulfur contents in building materials, providing detailed depth profiles and imaging element distributions with 1 mm spatial resolution. Detailed statistical evaluation is possible due to the spatial resolution and the fast measurement of the method. Practical applications of the method for damage assessment are demonstrated for three different sewage plants.
Abstract
In the recent years the application of infrared thermography and especially its active approaches lock-in thermography, impulse themography and pulse phase thermography (PPT) has gained more importance for non-destructive testing (NDT). In this paper it is demonstrated that PPT is very well suited for NDT in civil engineering. The method is based on pulse heating of the investigated specimen and on the observation of the cooling down process on its surface with an infrared camera. The transient behaviour is afterwards analysed with Fast Fourier Transformation, enabling the creation of phase and amplitude images with enhanced visualisation of the defects. Results of European and National (i.e. DFG) funded projects are presented, for example the detection of voids and inhomogeneities close to the surface and the localisation of delaminations on plastered concrete and masonry specimen.
ZUSAMMENFASSUNG
Im Rahmen eines von der Deutschen Forschungsgemeinschaft geförderten Vorhabens zur zerstörungsfreien Prüfung im Bauwesen wird in der Bundesanstalt für Materialforschung und -prüfung (BAM) in Zusammenarbeit mit der Technischen Universität Berlin (TUB) die Puls-Phasen-Thermografie (PPT) weiterentwickelt, bewertet und eingesetzt. Die durch die Impuls-Thermografie (IT) aufgenommenen Daten werden mittels Fast Fourier Transformation (FFT) bearbeitet. Die durch die FFT gewonnenen Phasenbilder reduzieren die Störeinflüsse von Oberflächeninhomogenitäten und ungleichmäßiger Erwärmung.
Die dargestellten Ergebnisse zeigen deutlich, dass sich die PPT sehr gut zur zerstörungsfreien Prüfung im Bauwesen eignet. Insbesondere Inhomogenitäten im oberflächennahen Bereich, wie Ablösungen und Hohlstellen hinter Beschichtungen (Putz, CFK-Laminate etc.), aber auch Defekte in größeren Tiefen können zuverlässig geortet und bildgebend dargestellt werden.