Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (89)
- Beitrag zu einem Tagungsband (50)
- Zeitschriftenartikel (30)
- Posterpräsentation (8)
- Beitrag zu einem Sammelband (5)
- Forschungsbericht (5)
- Buchkapitel (1)
- Dissertation (1)
- Sonstiges (1)
Schlagworte
- Tensile properties (15)
- BAM-Liste (14)
- Dangerous goods (14)
- Sealing materials (12)
- Biodiesel (11)
- Biofuels (11)
- Compatibility (11)
- BAM-List (9)
- Polyethylene grades (9)
- Shore hardness (9)
Organisationseinheit der BAM
- 3 Gefahrgutumschließungen; Energiespeicher (27)
- 3.2 Gefahrguttanks und Unfallmechanik (27)
- 7 Bauwerkssicherheit (9)
- 7.6 Korrosion und Korrosionsschutz (9)
- 1 Analytische Chemie; Referenzmaterialien (3)
- 1.4 Prozessanalytik (3)
- 2 Prozess- und Anlagensicherheit (3)
- 2.1 Sicherheit von Energieträgern (3)
- 8 Zerstörungsfreie Prüfung (3)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (3)
Eingeladener Vortrag
- nein (89)
Comparison of the Corrosion Resistance to Dangerous Goods of Austenitic CrNiMo and Duplex Steels
(2014)
Biofuels represent an important renewable fuel alternative to petroleum-derived transport fuels. Materials compatibility is a major concern whenever the fuel composition is changed. The aim of this work is to study the interaction of the elastomers: FKM, EPDM, CR, CSM, NBR, IIR, VMQ and FVMQ and biofuels such as biodiesel (FAME), E85 (fuel with 85% ethanol) and B10 (heating oil with 10% biodiesel). Exposure tests were performed with test specimens at 40°C (104°F) and 70°C (158°F) for 84 days to document the changes in mass, volume and tensile properties according to ISO 1817. The exposure tests in E85 showed that the weight gain caused by swelling was in the range up to 12%. The lowest decrease in the tensile properties was determined for FKM, VMQ and IIR. The weight gain of the elastomers in biodiesel varied between 10% (FKM) and 126% (CSM) and the loss of tensile strength between 16% (FKM) and 100% (CSM) at 70°C (158°F). FKM and FVMQ absorbed much less B10 and swelled less. NBR, EPDM, CR, CSM, IIR and VMQ were not resistant to B10 at all as the decrease in the tensile properties was significantly over 50%. Among all of the elastomers FKM showed high compatibility with these biofuels up to 70°C (158°F).
Comparison of the corrosion resistance to dangerous goods of austenitic CrNiMo and duplex steels
(2014)
The “BAM-List - Requirements for Tanks for the Transport of Dangerous Goods” is the basis in Germany for substance-related prototype approvals for tank Containers in Germany. Compatibility evaluations of selected metallic materials and polymeric materials under the influence of approximately 7200 dangerous goods have been published in the BAM-List since 1989. The austenitic CrNi- and CrNiMo-steels - UNS S30403, UNS S31600, UNSS31603 and UNS S31635 - are the materials mostly used worldwide for transport tanks. The duplex Steel UNS S31803 has been put on the BAMList due to the great interest of tank producers and transport Companies. Using UNS S31803 instead of 316L, the weight of the tanks can be reduced, and the list of transportable goods can be extended. The objective of these investigations was to compare the corrosion resistance of duplex Steel UNS S31803 and austenitic Steel UNS S31603. Therefore, test specimens of both steels were exposed to selected corrosive substances, such as formic acid, acetic acid, phosphoric acid, sulfuric acid, nitrating acid, monochloroacetic acid and trichloroacetone at 55 °C (30 °C, 70 °C). The test results have shown that the duplex Steel UNSS31803 is a good alternative to austenitic CrNiMo-steel UNS S31603 for tanks carrying corrosive dangerous goods.
Für Bauteile (Komponenten) von Versorgungsanlagen für flüssige Brenn- und Kraftstoffe muss die Beständigkeit der metallenen Werkstoffe und Polymere nachgewiesen werden. Im Anwendungsfall von Heizöl mit 20 % biogenen Anteilen in Form von Rapsölfettsäuremethylester (FAME, Biodiesel) ist es für eine konservative Beurteilung des Korrosionssystems Werkstoff/Medium/Umgebung wichtig, die Alterungseffekte des Mediums einzubeziehen.
Entwicklung eines Prüfverfahrens für die Untersuchung der Beständigkeit von metallenen Werkstoffen und Polymeren in Heizöl und Heizöl-FAME-Blends, das für eine Vorauswahl der Werkstoffe und zum Nachweis der Beständigkeit im Hinblick auf die bauaufsichtlichen Zulassungsverfahren geeignet ist. Ein Schwerpunkt wird bei den metallenen Werkstoffen auf der Erprobung von Messmethoden liegen, mit denen sich in kurzer Versuchszeit ein Korrosionsangriff detektieren lässt.
Die untersuchten Werkstoffe Aluminium, Stahl 1.0037, 1.4301, Kupfer, Messing (CuZn40Pb) und Zink (ZP0410) sind in B0, B20, B100 und in 6 Jahre altem B100 beständig.
Auch in einem Jahr alten B20 und in einem Jahr alten B100 sind die Werkstoffe beständig.
Bei Kupfer blieb die Korrosionsrate in der Flüssigphase sowohl in B20 (0 μ m/ a) als auch in B100 (4 μ m/ a) nach einem Jahr unverändert. Für das 6 Jahre alte B100 stieg die Korrosionsrate des Kupfers an (16 μ m/a). Im Gegensatz dazu sank bei Messing die Korrosionsrate in der Flüssigphase mit dem Alter des Brennstoffs, nach einem Jahr für B20 von 4 μ m/ a auf 1 μ m/a und für B100 von 36 μ m/ a auf 6 μ m/ a, im 6 Jahre alten B100 lag die Korrosionsrate des Messings bei 0 μ m/ a.
In 8 Jahre altem B10 trat bei Zink in der Flüssigphase Flächenkorrosion auf, es ist in dem Medium demnach nicht beständig. Messing zeigte örtliche Korrosion in der Gasphase, es ist folglich unbeständig und für den Einsatz in stark gealterten B10 nicht geeignet.
Aluminium, 1.0037, 1.4301 und Kupfer sind in dem 8 Jahre alten B10 beständig.
Die Änderung der Zugfestigkeit und der Reißdehnung von ACM, HNBR und FKM in Heizöl, B20 und gealterten B10 beträgt < 15 %. Diese Werkstoffe sind in Heizöl, B20 und in gealterten B10 unter Berücksichtigung des von der BAM zur Beurteilung der Beständigkeit festgelegten Grenzwertes von 15 % bei 40 °C als beständig zu bewerten.
PUR ist bei 40 °C nicht beständig in B20 und in gealtertem B10. Bei 70 °C ist HNBR nicht in B20 beständig aufgrund der Verringerung der Zugfestigkeit (40 %) und der Reißdehnung (50 %). FKM ist bei 70 °C in Heizöl und in B20 beständig.
In der Bundesrepublik Deutschland werden über 400 Mio.t Gefahrgüter jährlich in Tankfahrzeugen, Aufsetztanks, Batteriefahrzeugen, Eisenbahnkesselwagen und Tankcontainern befördert, davon etwa 150 Millionen Tonnen im Straßengüterverkehr. Zu den Hauptschadensursachen zählt die Korrosion, wobei die gleichmäßige und ungleichmäßige Flächenkorrosion die Korrosionsart ist, die beim Chemikalientransport in Tanks am häufigsten auftritt. Viele Schäden durch Lochkorrosion entstehen beim Transport von chloridhaltigen Medien bei Anwesenheit von Feuchtigkeit.
Die BAM-Liste - Anforderungen an Tanks für die Beförderung gefährlicher Güter - ist Grundlage für die stoffbezogenen Baumusterzulassungen für Tankcontainer und ortsbewegliche Tanks zur Beförderung gefährlicher Güter durch die BAM seit der Herausgabe der 1. Auflage 1989. In die BAM-Liste wurden vorrangig solche gefährlichen Güter aufgenommen, die potenziell in Tanks befördert werden können. Die Beständigkeitsbewertungen gebräuchlicher metallischer Tankwerkstoffe und polymerer Dichtungs-, Beschichtungs- und Auskleidungswerkstoffe werden auch bei der Zulassung von Kesselwagen und Tankfahrzeugen als Erkenntnisquelle verwendet. Diese Daten sind aber unter sorgfältiger Überprüfung der Übertragbarkeit auch für andere praktische Anwendungen und unter Berücksichtigung der jeweiligen Praxisbedingungen auch als Ratgeber für Verpackungen, IBC, Lagerbehälter, Rohrleitungen usw. aus metallischen Werkstoffen anwendbar.
In den internationalen Gefahrgutverordnungen ADR, RID und IMDG-Code wird nach einer vorgegebenen Prüffrist eine innere Besichtigung der Tanks gefordert. Bei Tankcontainern beträgt diese Prüffrist im ADR/RID, Kap. 6.8 , fünf Jahre (bei der Beförderung von ortsbeweglichen Tanks nach ADR/RID, Kap. 6.7, und nach dem IMDG-Code 2½ Jahre) und bei Tankfahrzeugen sechs Jahre. Im RID wird für Eisenbahnkesselwagen eine Prüffrist von acht Jahren für die Innenbesichtigung vorgeschrieben. Für die Dauer der Prüfintervalle muss die Werkstoffbeständigkeit der Tankwerkstoffe gewährleistet sein.
Biodiesel is subject to degradation processes like oil and grease. The oxidative degradation products of vegetable oil esters in biodiesel particularly lead to enhanced sedimentation in blended fuels.
The polarity of biodiesel increases its solvency and facilitates permeation and extraction. Solvation, swelling and/or extraction lead to changes in the physical properties and chemical changes of polymeric materials. It also accelerates the degradation (hydrolysis and oxidation) of these materials with the loss of additives and stabilizers.
The objective of this research was to determine the resistance of frequently used polymeric materials such as ACM, EPDM, FKM, FVMQ, CR, CSM, IIR, HNBR, NBR, PA, PE; POM, PUR, PVC and VMQ in biodiesel and heating oil with 10 %/20 % biodiesel (B10/B20) at 40°C and 70°C.
Mass, tensile strength and breaking elongation of the test specimens were determined before and after the exposure for 84 days in the biodiesel heating oil blends. The visual examination of some elastomer test specimens clearly showed the great volume increase until break or partial dissolution. Shore hardness A and D were determined before and after exposure of the test specimens in the biofuels for 42 days.
The elastomers CR, CSM, EPDM, IIR, NBR and VMQ were generally not resistant to biodiesel and B10 at 40°C and 70°C. FKM, ACM, HNBR, PA, PE, POM, and PVC showed high compatibility in B10/B20 at 40°C. A lower compatibility was determined for ACM in biodiesel. ACM and HNBR were not resistant in B20 at 70°C.
Für Bauteile (Komponenten) von Versorgungsanlagen für flüssige Brenn- und Kraftstoffe muss die Beständigkeit der metallenen Werkstoffe und Polymere nachgewiesen werden. Im Anwendungsfall von Heizöl mit 20 % biogenen Anteilen in Form von Rapsölfettsäuremethylester (FAME, Biodiesel) ist es für eine konservative Beurteilung des Korrosionssystems Werkstoff/Medium/Umgebung wichtig, die Alterungseffekte des Mediums einzubeziehen.
Entwicklung eines Prüfverfahrens für die Untersuchung der Beständigkeit von metallenen Werkstoffen und Polymeren in Heizöl und Heizöl-Biodiesel-Blends, das für eine Vorauswahl der Werkstoffe und zum Nachweis der Beständigkeit im Hinblick auf die bauaufsichtlichen Zulassungsverfahren geeignet ist. Ein Schwerpunkt wird bei den metallenen Werkstoffen auf der Erprobung von Messmethoden liegen, mit denen sich in kurzer Versuchszeit ein Korrosionsangriff detektieren lässt.
Heating oil storage tanks made of polyethylene grades have been on the market in Germany since the early 1970s. To ensure safety, their replacement is recommended by tank manufacturers after a period of 30 years. Polyethylene is subject to ageing by alteration of the properties during its life cycle. The degree of degradation and the nature of the process mainly depend on the chemical alteration of the polyethylene, the wall thickness of the tank and the environmental conditions. There are no data available on the long-term behaviour of the polyethylene grades, especially after a service life of more than 30 years.
The aim of this investigation was to find a suitable test method to determine the factual degree of damage in comparison to the uncontaminated polyethylene grades. Material data of the used polyethylene grades are available because the BAM was the competent authority for the tests and expert reports for the approval of these tanks until the middle of the 1990s. Therefore, tank sections from the bottom, the shell and the roof of 22 individual storage tanks produced of polyethylene grades A and B have been examined by Melt Flow Rate (MFR) and Attenuated Total Reflectance (ATR). Their service life was in the range between 20 and 41 years.
The MFR measurements of the tank sections showed differences in the values depending on the weight which was used (5 kg or 21.6 kg). An increase of the MFR was determined for the samples of polyethylene grade A, whereas a reduction of the MFR values was measured for most samples of polyethylene grade B. This grade is mainly subject to the internal ageing by cross-linkages, increased degree of branched molecules and loss of the plasticizer.
ATR analysis exhibits an absorption band at 909 cm‒1 predominantly in samples of polyethylene grade A indicating chain scission and concomitantly formed terminal vinyl groups. This absorption band can be used for the characterization of the ageing of the polyethylene grades.
Biodiesel is viewed as a major source of energy. In areas such as the European Union, where 80 % of the oil-based fuel is imported, there is also the desire to reduce dependence on external oil supplies.
Materials compatibility is a major concern whenever the fuel composition is changed. The question arises of whether polymeric materials are resistant to heating oil with 20 % biodiesel (B20) in comparison to pure heating oil.
The polarity of biodiesel increases its solvency and facilitates permeation and extraction. Solvation, swelling and/or extraction lead to changes in the physical properties. Extraction alters the fuel chemistry. These chemical changes could also accelerate the degradation (hydrolysis and oxidation) of the polymeric material with the loss of additives and stabilizers.
The objective of this research was to determine the resistance of frequently used materials for components in middle distillate facilities such as ACM, FKM, HNBR, PA, PE, POM, PUR and PVC in heating oil and heating oil blend B20 for 84 days at 40 °C, and FKM, HNBR, PA, POM, PUR and PVC at 70 °C.
Mass, tensile strength, breaking elongation and Shore hardness A (D) of the test specimens were determined before and after exposure for 84 (42) days in the test fuels under static conditions.
For the investigations under compressed conditions, the mass and the compression set of FKM test specimens were determined before and after exposure for 3, 7, 14, 28, 56 and 90 days in B20 at 40 °C and 70 °C according to ISO 815-1 “Rubber, vul-canized or thermoplastic - determination of compression set – Part 1: At ambient or elevated temperatures”.
There is not determined a threshold for the reduction in tensile properties and Shore hardness in the international standards. Therefore, a threshold of 15 % was determined for the evaluation of the compatibility.
The change of tensile strength and breaking elongation of test specimens made of ACM, FKM, HNBR, PA, PE, POM, PUR and PVC exposed to heating oil and the blend B20 was less than 15 % at 40 °C. A maximum reduction in Shore hardness A of 14 % was determined for ACM at 40 °C and for HNBR of 15 % at 70 °C.
It can be concluded that ACM, FKM, HNBR, PA, PE, POM, PVC and PUR were resistant in B20 at 40°C. FKM, PA, POM and PVC were evaluated as resistant in heat-ing oil and B20 at 70 °C, HNBR and PUR were not resistant in these fuels at 70°C.
Based on the mass increase and compression set values of FKM test specimens it can be stated that FKM is resistant in B20 under compressed conditions at 40 °C and 70 °C.
Die im In- und Ausland vorliegenden Forschungsarbeiten zur Kostenabschätzung der immissionsbedingten Materialschäden beruhen auf zwei ökonomischen Bewertungsverfahren. Bewertungsgrundlage des einen Verfahrens sind die in Labor- und Freibewitterungsversuchen ermittelten physikalisch-chemischen Dosis-Wirkungs-Beziehungen zwischen dem Schadstoffgehalt der Luft und den schadensanfälligen Materialien. Die andere Methode geht von den Unterschieden im Instandsetzungverhalten in Abhängigkeit vom Standort (Industrie-, Stadt- und Landatmosphäre) der Sachgüter aus.
Die ökonomische Bewertung der immissionsbedingten Materialschäden der Sachgütergruppen Freileitungsmaste, Brücken der Bundesautobahnen, Eisenbahnbrücken und -fahrleitungsmaste, fernmeldetechnische Einrichtungen der Deutschen Bundespost, Industrieanlagen, Wohngebäude und Denkmäler basiert auf sogenannten „Stock-at-risk“-Informationen, Dosis-Wirkungs-Funktionen der der Atmosphäre ausgesetzten Werkstoffe und auf in der Praxis vorliegenden Erfahrungswerten über Zeitintervalle der Erneuerung der Korrosionsschutzsysteme und Bauteile. In jenen Fällen, in denen der immissionsbedingte Anteil am Gesamtschaden noch nicht eindeutig nachgewiesen werden konnte, werden die Forschungslücken aufgezeigt bzw. Modellrechnungen durchgeführt.
In Order to be able to assess the damage caused to materials by acid deposition the first question to be considered is: Which materials are affected?
A wide ränge of materials are exposed to the extemal environment. These materials have different susceptibility to attack by acid rain and different stock at risk in the Federal Republic of Germany.
Biodiesel (FAME) from rapeseed is an environmentally friendly alternative to common fossil fuels. It is also suitable to serve as blending component to fuels like heating oil. If the fuel composition is changed, materials compatibility must be guaranteed. Adding polar biodiesel to nonpolar heating oil, changes the blend’s solvency and might cause swelling, extraction and solvation of polymers. The objective of this research was to investigate the compatibility of polymeric materials, which are commonly used for components in middle distillate facilities, along with blends of heating oil and 20 % biodiesel (B20). For this propose, ACM, HNBR, FKM, PE, PA 6, POM, PUR and PVC were exposed to heating oil and B20 for 42 and 84 days at 40 °C. In addition, the polymers HNBR, FKM, PA, POM and PVC were also exposed at 70 °C. Furthermore, the resistance of polymers in eight-year aged B10 at 40 °C was evaluated. Ageing of biodiesel increases acidity which might propagate polymer corrosion. The materials were evaluated as resistant, if the loss in tensile properties (tensile strength and elongation at break) and Shore hardness remained under 15 % compared to the initial unexposed material values. For investigations under compressed conditions, the compression set was determined for specimens of ACM, FKM and HNBR after exposure in heating oil B0 and B20 for 3,7,14, 28, 56 and 90 days at 40 °C according to ISO 815-1. It was found that the resistance in B20 at 40 °C was given for all tested polymers except PUR. In the 8 years aged B10, PUR and POM were not compatible and ACM just conditionally compatible. At 70 °C, FKM and PVC were resistant in B20, whereas HNBR and PA 6 were not compatible. Swelling occurred for the elastomers ACM, HNBR and PUR.
Rohrleitungssysteme sind aufgrund ihrer Funktion und Ausdehnung für den Betrieb, die Verfügbarkeit und die Sicherheit von Industrieanlagen von besonderer Bedeutung. Die bisher in definierten Intervallen durchgeführten, wiederkehrenden Prüfungen zur Sicherstellung leckagefreier Rohrleitungen sind kostenintensiv und mit einem erhöhten Aufwand verbunden.
Mit dem interdisziplinären Forschungsprojekt AGIFAMOR (Ageing Infrastructures – Akustisches Monitoring von Rohrleitungen) arbeitet die BAM an der Entwicklung und Erprobung einer örtlich und zeitlich kontinuierlichen Zustandsüberwachung von Rohrleitungen basierend auf einem faseroptischen akustischen Messsystem, welches einen vergleichsweise geringen Installationsaufwand der Sensoren erfordert. Mit diesem Verfahren sollen vor allem betriebsbedingte Schädigungen infolge von Korrosion sowie daraus entstehende Pittings oder Risse erkannt und damit Leckagen verhindert werden.
Im Rahmen einer Machbarkeitsstudie zum Teilaspekt „Detektion von Risswachstum“ wurde ein 2,5 m langes, definiert vorgekerbtes Stahlrohr mit der faseroptischen Sensorik (FOS) ausgestattet und quasistatisch unter 4-Punkt-Biegung belastet. Mit fortschreitender Belastung wächst, ausgehend vom vorhandenen Außenumfangskerb, ein Riss im Stahlrohr bis zum Erreichen der Leckage – in der Praxis ein gefährliches Schadensszenario.
Parallel zur FOS erfolgten Messungen mit Schallemissionssensoren, Beschleunigungssensoren und Potentialsonden, deren Ergebnisse die Interpretation der FOS-Messergebnisse unterstützen sollen.
In der Prozessindustrie werden häufig gefährliche Stoffe eingesetzt, so dass auch kleinste Leckagen der medienführenden Anlagenteile zu Gefährdungen der Arbeitnehmer sowie zur Belastung der Umwelt führen können. Für die Gewährleistung einer dauerhaften Verfügbarkeit der Infrastruktur ist die frühzeitige Erkennung und Ortung von potentiell gefährlichen Veränderungen an den Wandungen von Rohrleitungen und Behältern (in Form von Rissen, Pittings und Ablagerungen) erforderlich. Am Beispiel von Rohrleitungen, sollen im Rahmen des Projekts AGIFAMOR an der Bundesanstalt für Materialforschung und -prüfung (BAM), im Sinne einer Machbarkeitsstudie die Verfahren der verteilten akustischen und faseroptischen Sensorik zur kontinuierlichen Überwachung und Detektion potentiell gefährlicher Veränderungen in Industrieanlagen erprobt und qualifiziert werden. Dabei sollen die Applikation der optischen Sensorfasern hinsichtlich der Signalübertragung auf den Sensor optimiert und die Erkennung der für dieses Anwendungsgebiet relevanten Schallsignaturen entwickelt werden. Mithilfe eines solchen Messsystems können mit geringem Aufwand ausgedehnte Strukturen, auch unter erschwerten Bedingungen (z.B. hohe Temperatur, Einfluss von Chemikalien) kontinuierlich überwacht werden.
Pipelines and industrial piping systems are particularly relevant regarding technical safety, availability and maintenance. Large flow rates of hazardous substances imply that even smallest leakages can lead to high environmental impacts. Therefore, and to ensure the availability of infrastructure, an early detection and localization of potentially hazardous degradations to the walls (e.g. cracks, pittings, sedimentation, etc.) of the containments is necessary. However, in many cases it is not feasible to equip pipelines with a large number of point sensors at reasonable expense.
The principle of distributed fibre optic sensing relies on one single optical fibre, which simultaneously acts as a spatially continuous sensor as well as the signal transducer. Therefore, extensive structures can be provided with this type of sensor with comparatively low efforts.
As a consequence, monitoring oil and gas pipelines using distributed fibre optic sensors is on the upswing. Besides the established methods to measure temperature and strain, distributed acoustic sensing (DAS) has lately received considerable attention as a means to detect and localize third party threats to pipelines (approach of vehicles, digging, mechanical manipulation).
The so far not utilized potential of DAS as a means for continuous condition monitoring of pipes by detecting and localizing acoustic signals that point to certain damage scenarios, is currently under investigation in an interdisciplinary research project at BAM (AGIFAMOR, Ageing Infrastructures – Fibre Optic Monitoring of Pipes).
In order to qualify distributed acoustic fibre optic sensors for this application area, we especially focus on detecting and identifying the relevant acoustic emissions of interesting degradations as well as on the optimal way of application of the optical fibres to the specimen to achieve an optimal signal transmission of acoustic signals.
Zum Vergleich der Polyethylenformstoffe für eine Bauart von Gefahrgutverpackungen und IBC wurden die Materialkennwerte: Schmelze-Massefließrate MFR, Dichte D, Kerbschlag-zähigkeit acN bei -30 °C, Spannungsrissbeständigkeit (bestimmt mit dem Full Notch Creep Test) und Beständigkeit gegen oxidativen Abbau Ox (bestimmt durch den prozentualen Anstieg des MFR in Salpetersäure) in der DIN EN 15507 – Verpackung – Verpackungen zur Beförderung gefährlicher Güter – Vergleichende Werkstoffprüfung von Polyethylensorten ausgewählt.
Das Ziel der Untersuchungen war die Auswahl eines Kennwertes für die Bestimmung des mechanischen Leistungsniveaus von Polyethylenformstoffen, da unter Druck Verpackungen beulen oder knicken. Zur Auswahl standen drei Prüfverfahren:
a) Bestimmung der Biegesteifigkeit S nach DIN 53 350 (Prinzip von Ohlsen).
b) Bestimmung der Biegefestigkeit σfM und Biegedehnung ɛfM nach DIN EN ISO 178
c) Bestimmung der Druckkraft Fmax und Verformung dL bei Fmax nach DIN EN ISO 604.
Die Prüfmethode zur Bestimmung der Biegesteifigkeit nach DIN 53 350 eignet sich zum Vergleich des mechanischen Leistungsniveaus der Formstoffe. Zur Verbesserung der Reproduzierbarkeit der Ergebnisse sollte der Skalierungsbereich der Prüfapparatur erweitert wer-den, um genauere Messergebnisse zu erzielen.
Der Dreipunktbiegeversuch nach DIN EN ISO 178 eignet sich bei verformungsfähigen Kunststoffen, wie dem Polyethylen, zur Bestimmung der Biegefestigkeit σfM. Dieser Ver-such besitzt den Nachteil, dass am Ort des maximalen Biegemoments in der Randschicht, wo auch die maximale Biegespannung erzeugt wird, zusätzlich der Biegestempel angreift.
Die Messergebnisse haben gezeigt, dass die Druckprüfung nach DIN EN ISO 604 sich sehr gut zur Bewertung des mechanischen Verhaltens der Polyethylenformstoffe unter Druckbelastung (Stapeldruckprüfung der Verpackungen) eignet.
Polyethylene terephthalate (PET) is used as material for packagings for the transport of dangerous goods due to its high strength and stiffness. For this reason, the wall thickness and weight of the packagings can be reduced.
According to the European dangerous goods regulations RID and ADR, samples of PET design types of packagings for dangerous goods must be pre-stored with the original filling good for six months at 23 °C, before the design type tests can be carried out. For packagings made of polyethylene (PE) tests to prove the stress cracking resistance by using laboratory methods are possible to reduce time and costs. Therefore, standard liquids, simulating the different types of damaging effects on PE are defined in RID and ADR. However, there is no information and research available about the damaging mechanisms on PET, especially regarding to stress cracking resistance and test methods.
One laboratory test method is the Full Notch Creep Test (FNCT), which was developed for polyethylene (PE) and is described in the standards EN ISO 13274 and EN 15507. It was investigated whether testing specimens made of PET with a full coplanar notch around the middle of the specimens show weakening after the impact of a tensile force in the standard liquid (5 % wetting solution) at 50 °C. The tests showed that this method couldn’t be used for PET because the specimens broke during notching due to the high brittleness of PET. Another disadvantage is the very time-consuming temper process for twelve hours after molding of the sheets.
Another test method is described in BAM’s Dangerous Goods Rule BAM-GGR 015. This test was carried out with 1l PET bottles, which were filled with a 5% wetting solution and mounted with a clamping tool for 28 days at 40°C. Tensile test specimens were cut out afterwards from the middle of the bottles in the deformed areas. The tensile properties of the PET specimens couldn’t be determined due to the hardness of the material.
The only test method to provide information about the stress cracking resistance of PET was to perform stacking tests with PET design types of packagings. 1l bottles made of PET were filled with the standard liquid (5 % wetting solution) and stored with a stacking load for 28 days at 40°C according to EN ISO 16495. The test bottles of PET passed the stacking tests.
In conclusion, samples of PET design types of packagings for dangerous goods must be pre-stored with the original filling good for six months at 23 °C, before the design type tests can be carried out.