Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (72)
Sprache
- Englisch (70)
- Deutsch (1)
- Mehrsprachig (1)
Referierte Publikation
- ja (72) (entfernen)
Schlagworte
- ELISA (12)
- Mass spectrometry (7)
- Affinity chromatography (6)
- Lab-on-a-chip (6)
- Nitrotyrosine (6)
- Antibody (5)
- Fluorescence (5)
- Immunoassay (5)
- LC-MS/MS (5)
- Tyrosine (5)
- Air pollution (4)
- HPLC (4)
- Metrology (4)
- Nitration (4)
- Reference material (4)
- Allergy (3)
- Amino acid analysis (3)
- Biosensor (3)
- Biosensors (3)
- Caffeine (3)
- Immunoassays (3)
- Monoclonal antibody (3)
- Nitrogen oxides (3)
- PCR (3)
- Peptides (3)
- Phenylalanine (3)
- Quality control (3)
- Reproducibility (3)
- Screening (3)
- Terrorism (3)
- Traceability (3)
- AAA (2)
- Affinity extraction (2)
- Albumin (2)
- Animal species differentiation (2)
- Aromatic amino acid analysis (2)
- BSA (2)
- Biochip (2)
- Biophotonics (2)
- Carbamazepine (2)
- Carrier protein (2)
- Chromatography (2)
- Combinatorial chemistry (2)
- Copper (2)
- Degradation (2)
- Diagnostics (2)
- Dimer (2)
- Dityrosine (2)
- Documentation (2)
- Explosives detection (2)
- Fish species (2)
- Fluoreszenz (2)
- HTS (2)
- Hapten (2)
- Hybridoma (2)
- Hydrolysis (2)
- IgG (2)
- Immunogen (2)
- LAMP (2)
- MALDI (2)
- Magnetic resonance imaging (2)
- Microarray (2)
- Microfluidics (2)
- Miniaturization (2)
- Mobile phase (2)
- Monolithic column (2)
- Multiplexing (2)
- Nickel (2)
- Open Science (2)
- Optical sensors (2)
- Oxidation (2)
- Ozone (2)
- Peptide (2)
- Peptide library (2)
- Permethrin (2)
- Photonic sensors (2)
- Protein (2)
- Protein nitration (2)
- Quality Control (2)
- Quantitative protein analysis (2)
- Reference materials (2)
- Ring resonator (2)
- SBA-15 (2)
- SPR (2)
- Sapphire (2)
- Security (2)
- Sequence coverage (2)
- Sequencing (2)
- Silanization (2)
- Silicon photonics (2)
- Synthetic peptides (2)
- TATP (2)
- Tryptophan (2)
- Validation (2)
- immunoassay (2)
- 150th anniversary (1)
- 150th anniversary of BAM (1)
- 2,5-dihydroxyacetophenone (1)
- 280 nm (1)
- 3R concept (1)
- 6xHis (1)
- AAAA (1)
- ABC (1)
- ABID (1)
- ADC (1)
- ATCUN (1)
- Aautomatisation (1)
- Absorption (1)
- Acute myocardial infarction (1)
- Additive Manufacturing (1)
- Adhesion (1)
- Adhesives (1)
- Adjuvantien (1)
- Adsorption (1)
- Aeroallergens (1)
- Affinity (1)
- Affinity Chromatography (1)
- Affinity Extraction (1)
- Affinity Separation (1)
- Affinity immobilization (1)
- Aflatoxin (1)
- Air filter samples (1)
- Air particulate matter (1)
- Air-segmented flow (1)
- Airport (1)
- Alanine scan (1)
- Algal toxins (1)
- Allergene (1)
- Allergie (1)
- Aluminum oxide (1)
- Ambient ionization (1)
- Amplification (1)
- Analysis (1)
- Analytical sciences (1)
- Anatoxin-a (1)
- Anatoxin-a(s) (1)
- Animal welfare (1)
- Anthropocene (1)
- Anthropogenic markers (1)
- Antibodies (1)
- Antibody Purification (1)
- Antibody antigen complex (1)
- Antibody drug conjugate (1)
- Antibody identification (1)
- Antibody quality (1)
- Antibody-gated indicator delivery (1)
- Antibody-gated indicator delivery systems (1)
- Antigen (1)
- Array (1)
- Atmospheric aerosol (1)
- Augenbohne (1)
- Automated Purification (1)
- Aviation (1)
- BAM (1)
- BCA test (1)
- BODIPY-Farbstoffe (1)
- Back-side integration (1)
- Bacterial lysates (1)
- Basic solvent (1)
- Benchmarking study (1)
- Benzene-1,3,5-tricarboxylic acid (1)
- Bet v 1 (1)
- Betula pendula (1)
- Binder (1)
- Binding molecule (1)
- Binding strength (1)
- Bio-interaction (1)
- Bioanalysis (1)
- Biochemistry (1)
- Bioconjugate (1)
- Bioinformatics (1)
- Bioluminescence (1)
- Biomarker (1)
- Biosensing (1)
- Biosensor development (1)
- Bioseparation (1)
- Biotechnology (1)
- Biotoxins (1)
- Birch pollen allergen (1)
- Block copolymer (1)
- Blue-green algae (1)
- Bombs (1)
- Borosilicate Glass (1)
- Bovine serum albumin (1)
- Bovine serum albumin (BSA) (1)
- Bradford (1)
- Bundesanstalt für Materialforschung und -prüfung (1)
- Byproducts (1)
- COVID-19 (1)
- Calibration (1)
- Carbamazepin (1)
- Cardiac troponin (1)
- Cardiovascular (1)
- Carrier (1)
- Carrier load (1)
- Certified reference materials (1)
- Cetirizin (1)
- Cetirizine (1)
- Chelate (1)
- Chemical evolution (1)
- Chemical protein modification (1)
- Chemiluminescence (1)
- Chemosensor (1)
- Chicken antibodies (1)
- Chip (1)
- Chirality (1)
- Chronic kidney disease (1)
- Citation (1)
- Citizen Science (1)
- Cleavage (1)
- Click chemistry (1)
- Click reaction (1)
- Clone M2 (1)
- Collection (1)
- Column holder (1)
- Combinatorial peptide library (1)
- Combinatorial polymer libraries (1)
- Combustion (1)
- Commercialization (1)
- Compartmentalization (1)
- Competitive immunoassay (1)
- Compound-independent calibration (1)
- Concentration step (1)
- Conformation (1)
- Conjugates (1)
- Conjugation density (1)
- Conjugation ratio (1)
- Construction (1)
- Continuous Sensor (1)
- Contrast agent (1)
- Coproantibodies (1)
- Corona virus (1)
- Corundum (1)
- Cross-linking (1)
- Cyanotoxins (1)
- Cylindrospermopsin (1)
- Cytochrome P450 CYP1A2 (1)
- Cytoplasm (1)
- DAMP (1)
- DAR (1)
- DHAP (1)
- DNA chip (1)
- DNA-Chip (1)
- Damage-associated molecular patterns (DAMPs) (1)
- De novo peptide sequencing (1)
- Deep learning-based tools (1)
- Dendrimer (1)
- Derivatization (1)
- Diagnosis (1)
- Diagnostic Antibodies (1)
- Diesel (1)
- Diesel exhaust (1)
- Digital PCR (1)
- Digital immunoassay (1)
- Digitale PCR (1)
- Dimerization (1)
- Dissociation constant (1)
- Dityrosine crosslinking (1)
- Docking (1)
- Down Stream Processing (1)
- Downstream processing (1)
- Drug (1)
- Drug discovery (1)
- Drug transporters (1)
- Drug-to-antibody ratio (1)
- EDTAD (1)
- ELISA methods (1)
- ESI MS (1)
- Editorial (1)
- Elastin-specific contrast agent ESMA (1)
- Element Specific Bioimaging Using Laser Ablation (1)
- Emergency (1)
- Enantiomeric excess ee (1)
- Encapsulation (1)
- Enhancement (1)
- Environment (1)
- Environmental analysis (1)
- Environmental monitoring (1)
- Environmental pollutants (1)
- Enzyme-linked immunosorbent assay (1)
- Epoxy (1)
- Equilibrium constant (1)
- Error correction (1)
- Escherichia coli (1)
- Ethylenediaminetetraacetic acid (1)
- Etofenprox (1)
- Exhaust (1)
- Experiment (1)
- Explosive (1)
- FLAG peptide (1)
- FPLC (1)
- Farbstoffe (1)
- Feces (1)
- Fischarten (1)
- Flow injection immunoassay (1)
- Fluorescence label (1)
- Folding chirality (1)
- Formulation additives (1)
- Fragmentation (1)
- Functionalization (1)
- Gadofosveset (1)
- Gadolinium-based contrast agent (1)
- Gadovist (1)
- Gated hybrid material (1)
- Gated materials (1)
- Github (1)
- Glass Support (1)
- Glue (1)
- Glutaraldehyde (1)
- Glycidylethers (1)
- Grass pollen (1)
- HPLC-DAD (1)
- Hapten immunoassay (1)
- Harmful algal blooms (1)
- Hay fever (1)
- Heart attack (1)
- Heavy chains (1)
- Heterologous hapten (1)
- HexaHis-Tag (1)
- High pH (1)
- High-Speed (1)
- High-Speed Separations (1)
- High-throughput (1)
- His6 (1)
- His8 (1)
- Histidine (1)
- Human Plasma (1)
- Hybridisierung (1)
- Hydrochloric acid (1)
- Hydroxyl radicals (1)
- IC50 (1)
- IMAC purification (1)
- Identity (1)
- IgE (1)
- IgG determination (1)
- IgY (1)
- Iinductively coupled plasma mass spectrometry (1)
- Immunization monitoring (1)
- Immunoaffinity extraction (1)
- Immunocapture (1)
- Immunochemical response optimization (1)
- Immunoglobulin E (1)
- Immunoglobulins (1)
- Immunometric assay (1)
- Immunometric biosensor (1)
- Immunosensor (1)
- Impact (1)
- Impurites (1)
- Inductively Coupled Mass Spectroscopy (1)
- Inflammation (1)
- Inhibition (1)
- Insecticide (1)
- Interlaboratory studies (1)
- Internal standard (1)
- Iron disorders (1)
- Isotope dilution (1)
- Jahrestag (1)
- Kjeldahl (1)
- Klimaveränderung (1)
- Kreuzreaktivität (1)
- LC-MS (1)
- LC-UV absorbance (1)
- LCMSMS (1)
- LIF (1)
- Lab-on-a-Chip (1)
- Lab-on-chip (1)
- Label (1)
- Laborvergleichuntersuchungen (1)
- Ladder sequencing (1)
- Ladungstransfer (1)
- Lanthanide DOTA (1)
- Lanthaniden (1)
- Laser (1)
- Laser-induced fluorescence (1)
- Laser-induced plasma (1)
- Lateral flow assay (1)
- Lateral flow test (1)
- Lead identification (1)
- Library (1)
- Life sciences (1)
- Light chain (1)
- Light chains (1)
- Limit of detection (1)
- Linker (1)
- Liquid chromatography (1)
- Liver function tests (1)
- Low-cost (1)
- Luftverschmutzung (1)
- Luminol (1)
- MALDI-TOF (1)
- MALDI-TOF MS (1)
- MR Angiography (1)
- MST (1)
- Macroporous polymers (1)
- Mass Spectrometry (1)
- Massenspektrometrie (1)
- Material sciences (1)
- Material-binding Peptides (1)
- Mechanism (1)
- Mesoporous particles (1)
- Mesoporöse Materialien (1)
- Metal labeling (1)
- Metall-Markierung (1)
- Metalloprotein (1)
- Method (1)
- Microarrays (1)
- Microcystins (1)
- Microfluidic mixing (1)
- Microfluidic system (1)
- Micrometeorites (1)
- Microresonator (1)
- Microwave (1)
- Milch (1)
- Miller and Urey (1)
- Missing fragmentation sites (1)
- Molecular-MRI (1)
- Molekularbiologie (1)
- Monoclonal Antibodies (1)
- Monoclonal Antibody (1)
- Monoclonal antibodies (1)
- Monolith (1)
- Multiplex (1)
- Multiplex methods (1)
- Murchison meteorite (1)
- Mycotoxin (1)
- NHS (1)
- NHS-Ester (1)
- NIR-Farbstoffe (1)
- NIST (1)
- NIST-mAb 8671 (1)
- Nanocarrier (1)
- Nanoparticle (1)
- Nanoparticles (1)
- Nanophotonics (1)
- Nanoscience (1)
- Natural products (1)
- Neoallergen (1)
- Neoepitopes (1)
- Nickel chelate (1)
- Nitrogen dioxide (1)
- Nodularins (1)
- Nonspecific binding (NSB) (1)
- Nucleocapsid (1)
- OBOC library (1)
- Oligomer (1)
- Oligomerization (1)
- On-chip screening (1)
- One-bead-one-compound library (1)
- Online biosensor (1)
- Online detection (1)
- Open science (1)
- Optical detection (1)
- Optoelectronic (1)
- Orbitrap (1)
- Organic peroxides (1)
- Oriented immobilization (1)
- Ortho-Phthalaldehyde (1)
- Ovalbumin (1)
- Ozon (1)
- PALM (1)
- PEG (1)
- PIC technology (1)
- Partikel (1)
- Pattern recognition receptor (1)
- Peer review (1)
- Peptide Library (1)
- Peptide analysis (1)
- Peptide aptamers (1)
- Peptide binder (1)
- Peptide folding (1)
- Peptide library screening (1)
- Peptide losses (1)
- Peptide mass fingerprinting (1)
- Peroxidase (1)
- Pesticide (1)
- Pflanzenvirus (1)
- Pharmaceutical (1)
- Pharmaceuticals (1)
- Phenothrin (1)
- Phenylketonuria (1)
- Phl p 5 (1)
- Phleum pratense (1)
- Photonic biosensor (1)
- Plant virus (1)
- Plastics (1)
- Point of inflection (1)
- Polishing (1)
- Pollen (1)
- Pollen extract (1)
- Pollutant (1)
- Polyclonal Antibodies (1)
- Polyethers (1)
- Polyethylene glycol (1)
- Polyglycerol (1)
- Polymer-binding Peptides (1)
- Polymers (1)
- Polypropylene (1)
- Porous rock (1)
- Prebiotic chemistry (1)
- Precision polymer sequencing (1)
- Preprocessing (1)
- Primer (1)
- Primordial soup (1)
- Protein A (1)
- Protein Purification (1)
- Protein analysis (1)
- Protein conjugation (1)
- Protein content (1)
- Protein degradation (1)
- Protein folding (1)
- Protein hydrolysis (1)
- Protein nitration degree (1)
- Protein oligomer analysis (1)
- Protein oligomerization (1)
- Protein oligomers (1)
- Protein quantification (1)
- Protein test (1)
- Protein-Quantifizierung (1)
- Proteinoid (1)
- Proteins (1)
- Proteomics (1)
- Pseudo peptides (1)
- Purification (1)
- Purity (1)
- Pyrethroid (1)
- QC (1)
- Quality assurance (1)
- Qualitätskontrolle (1)
- Quantitative proteomics (1)
- RBD (1)
- Racemate (1)
- Reagenzien (1)
- Real-time measurement (1)
- Recombinant Antibody (1)
- Recombinant antibody (1)
- Recombinant protein (1)
- Recovery (1)
- References (1)
- Referenzmaterialien (1)
- Regeneration (1)
- Reinheitsbestimmung (1)
- Replication (1)
- Replication crisis (1)
- Reproducibility crisis (1)
- Resonance wavelength shift (1)
- Ring resonators (1)
- Robustness (1)
- Round robin exercise (1)
- SBA-16 (1)
- SI traceability (1)
- Saliva (1)
- Saxitoxins (1)
- Schlangenbohne (1)
- Schnellmethoden (1)
- Scientific publication (1)
- Segregation (1)
- Self-assembled monolayers (SAM) (1)
- Self-assembly (1)
- Semtex (1)
- Sensor (1)
- Sequence-defined oligomer (1)
- Sequencing algorithm (1)
- Signal amplification (1)
- Single molecule (1)
- Sintered Material (1)
- Size exclusion chromatography (1)
- Smartphone readout device (1)
- Software (1)
- Solid-binding Peptides (1)
- Solid-phase extraction (SPE) (1)
- Solubilizer (1)
- Special issue (1)
- Spike protein (1)
- Sprengstoffe (1)
- Stable isotope labeling (1)
- Standardisation (1)
- Standardisierung (1)
- Standardverfahren (1)
- Stickoxide (1)
- Structure (1)
- Sulfo-NHS (1)
- Sulfur (1)
- Surface Activation (1)
- Surface chemistry (1)
- Surface plasmon resonance (1)
- Surface water (1)
- Surface-plasmon resonance (1)
- Surrogate citations (1)
- TLR4 activation (1)
- Target (1)
- Terephthalic acid (1)
- Test midpoint (1)
- Test strip analysis (1)
- Tetranitromethane (1)
- Therapeutic Antibodies (1)
- Tholins (1)
- Toll-like receptor 4 (1)
- Topical collection: Analytical Methods and Applications in the Materials and Life Sciences (1)
- Toxicity (1)
- Toxicity test (1)
- Triacetone triperoxide (1)
- Trimer (1)
- Tripeptides (1)
- Trust (1)
- Tryptic digest (1)
- Type-I pyrethroids (1)
- Ultrasensitive (1)
- Upscaling (1)
- Vibrio fischeri (1)
- Vigna unguiculata (1)
- Visualization (1)
- Wastewater marker (1)
- Water (1)
- Waveguide (1)
- Wipe test (1)
- Zenodo (1)
- antibody (1)
- bioisosteric replacement (1)
- cross-reactivity (1)
- explosives (1)
- hapten (1)
- irreproducibility (1)
- ligand binding assay (1)
- monoclonal antibody (1)
- non-specific binding (1)
- pH-Abhängigkeit (1)
- paper retraction (1)
- peer reviewimmunochemistry (1)
- quality control (1)
- replication (1)
- reproducibility crisis (1)
- security (1)
- selectivity (1)
- self-replication (1)
- terrorism (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (41)
- 1.5 Proteinanalytik (41)
- 1.1 Anorganische Spurenanalytik (6)
- 1.9 Chemische und optische Sensorik (6)
- 6 Materialchemie (6)
- 6.3 Strukturanalytik (5)
- 1.8 Umweltanalytik (4)
- 1.4 Prozessanalytik (2)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
- VP Vizepräsident (2)
Triacetone triperoxide (TATP), an improvised explosive, is a potential security threat because of its cost-efficient synthesis and the difficulty in detecting it. A highly selective antibody could provide the necessary specificity to the detection process. To obtain antibodies, a hapten made from acetone, hydrogen peroxide, and 7-oxooctanoic acid has been designed, synthesized, and confirmed by NMR that displays the utmost similarity to the analyte. The single-crystal X-ray structures of the solvated species TATP·methanol (1:1) and the TATP derivate were determined. In both compounds, the molecules exhibit D3 symmetry and adopt a twisted boat-chair conformation. The hapten was coupled to bovine serum albumin, and mice were immunized. An immune response against TATP was elicited, and selective antibodies were detected in the mouse serum, which should be very useful for the development of a TATP biosensor system. An ELISA with a limit of detection for TATP of 65 µg L-1 is shown.
An immunoassay was developed for ochratoxin A (OTA) detection in wine and two completely different detection methods were compared: ICP-MS and photometry. For labelling, we applied secondary antibodies conjugated with gold nanoparticles for ICP-MS and with horseradish peroxidase for photometric detection, respectively. Detection limits of the assay were determined as 0.003 µg L-1 for both detection methods. OTA in wine was determined below the EU limit value of 2 µg kg-1. The measurement range was between 0.01 and 1 µg L-1 for ICP-MS and photometric detection. Assay precision detected by ICP-MS and photometry were similar showing that precision of the detection method has only a minor effect on total assay precision. By using BSA as a buffer additive to minimize nonspecific binding, we could also confirm that OTA strongly binds to BSA. In a comparison study of several additives, casein was found to be preferable.
A non-invasive method to monitor the humoral immune response in mice after immunization is described. From fecal pellets of an individual mouse, a sufficient amount of active immunoglobulins or their fragments can be extracted to perform a regular examination of the status of the immune response by immunoassay. Hapten-specific antibodies from the feces of mice from three immunization trials showed very similar characteristics to those obtained from serum at a given date. Therefore, it can be suspected that some serum IgG enters the intestinal lumen and ends up in the feces, where they appear to be considerably stable. Hapten-specific IgAs were not found in the feces. Being able to analyze antibody titers in feces could be an interesting animal welfare refinement to standard practice that does not entail repeated blood sampling.
Monitoring carbamazepine in surface and wastewaters by an immunoassay based on a monoclonal antibody
(2009)
The pharmaceutical compound carbamazepine (CBZ) is an emerging pollutant in the aquatic environment and may potentially be used as a wastewater marker. In this work, an enzyme-linked immunosorbent assay (ELISA) for the detection of carbamazepine in surface and sewage waters has been developed. The heterogeneous immunoassay is based on a commercially available monoclonal antibody and a novel enzyme conjugate (tracer) that links the hapten via a hydrophilic peptide (triglycine) spacer to horseradish peroxidase. The assay achieves a limit of detection of 24 ng/L and a quantitation range of 0.05-50 µg/L. The analytical performance and figure of merits were compared to liquid chromatography-tandem mass spectrometry after solid-phase extraction. For nine Berlin surface water samples and one wastewater sample, a close correlation of results was observed. A constant overestimation relative to the CBZ concentration of approximately 30% by ELISA is probably caused by the presence of 10,11-epoxy-CBZ and 2-hydroxy-CBZ in the samples. The ELISA displayed cross-reactivities for these compounds of 83% and 14%, respectively. In a first screening of 27 surface water samples, CBZ was detected in every sample with concentrations between 0.05 and 3.2 µg/L. Since no sample cleanup is required, the assay allowed for the determination of carbamazepine with high sensitivity at low costs and with much higher throughput than with conventional methods.
Caffeine is a useful indicator to quickly assess liver function. High-throughput tests are needed for single-point caffeine measurements, with low cross-reactivity toward its major metabolite, paraxanthine. A newly developed ELISA was compared with an LC-MS/MS reference method, using 60 saliva samples from 10 individuals, before and after caffeine intake. Bland-Altman plot, Student t-test and F-test were used to compare the two methods. Proteins were precipitated using organic solvent and the caffeine recoveries compared with those obtained using sample microfiltration. The antibody, with a low cross-reactivity toward paraxanthine (0.08%), allows quantification of caffeine in saliva samples from 2.5 µg/L to 125 µg/L with high precision and the ELISA shows comparable results to those obtained by LC-MS/MS. A one-step protein precipitation using an organic solvent provides comparable results to a more costly and time-consuming microfiltration pre-treatment of samples. The new ELISA is a fit-for-purpose method to accurately and precisely determine caffeine in saliva samples.
Carbamazepine (CBZ), caffeine and cetirizine were monitored by enzyme-linked immunosorbent assays (ELISAs) in surface and wastewaters from Berlin, Germany. This fast and cost-efficient method enabled to assess the spatial and temporal variation of these anthropogenic markers in a high-throughput screening. CBZ and cetirizine were detected by the same antibody, which selectively discriminates between both compounds depending on the pH value used in the incubation step. To our best knowledge, this is the first dual-analyte immunoassay working with a single antibody.
The frequent sampling with 487 samples being processed allowed for the repeated detection of unusually high concentrations of CBZ and caffeine. ELISA results correlate well with the ones obtained by liquid chromatography tandem mass spectrometry (LC-MS/MS). Caffeine concentrations found in surface waters were elevated by combined sewer overflows after stormwater events. During the hay fever season, the concentrations of the antihistamine drug cetirizine increased in both surface and wastewaters.
Caffeine was almost completely removed during wastewater treatment, while CBZ and cetirizine were found to be more persistent. The maximum concentrations of caffeine, CBZ and cetirizine found in influent wastewater by LCMS/MS were 470, 5.0 and 0.49 µg L-1, while in effluent wastewater the concentrations were 0.22, 4.5 and 0.51 µg L-1, respectively. For surface waters, concentrations up to 3.3, 4.5 and 0.72 µg L-1 were found, respectively.
Triacetone triperoxide (TATP) is a primary explosive, which was used in various terrorist attacks in the past. For the development of biosensors, immunochemical µ-TAS, electronic noses, immunological test kits, or test strips, the availability of antibodies of high quality is crucial. Recently, we presented the successful immunization of mice, based on the design, synthesis, and conjugation of a novel TATP derivative. Here, the long-term immunization of rabbits is shown, which resulted in antibodies of extreme selectivity and more than 1,000 times better affinity in relation to the antibodies from mice. Detection limits below 10 ng L-1 (water) were achieved. The working range covers more than four decades, calculated from a precision profile. The cross-reactivity tests revealed an extraordinary selectivity of the antibodies—not a single compound could be identified as a relevant cross-reactant. The presented immunoreagent might be a major step for the development of highly sensitive and selective TATP detectors particularly for security applications.
Peptide pools consist of short amino acid sequences and have proven to be versatile tools in various research areas in immunology and clinical applications. They are commercially available in many different compositions and variants. However, unlike other reagents that consist of only one or a few compounds, peptide pools are highly complex products which makes their quality control a major challenge. Quantitative peptide analysis usually requires sophisticated methods, in most cases isotope-labeled standards and reference materials. Usually, this would be prohibitively laborious and expensive. Therefore, an approach is needed to provide a practical and feasible method for quality control of peptide pools. With insufficient quality control, the use of such products could lead to incorrect experimental results, worsening the well-known reproducibility crisis in the biomedical sciences. Here we propose the use of ultra-high performance liquid chromatography (UHPLC) with two detectors, a standard UV detector at 214 nm for quantitative analysis and a high-resolution mass spectrometer (HRMS) for identity confirmation. To be cost-efficient and fast, quantification and identification are performed in one chromatographic run. An optimized protocol is shown, and different peak integration methods are compared and discussed. This work was performed using a peptide pool known as CEF advanced, which consists of 32 peptides derived from cytomegalovirus (CMV), Epstein–Barr virus (EBV) and influenza virus, ranging from 8 to 12 amino acids in length.
The affinity constant, also known as the equilibrium constant, binding constant, equilibrium association constant, or the reciprocal value, the equilibrium dissociation constant (Kd), can be considered as one of the most important characteristics for any antibody–antigen pair. Many methods based on different technologies have been proposed and used to determine this value. However, since a very large number of publications and commercial datasheets do not include this information, significant obstacles in performing such measurements seem to exist. In other cases where such data are reported, the results have often proved to be unreliable. This situation may indicate that most of the technologies available today require a high level of expertise and effort that does not seem to be available in many laboratories. In this paper, we present a simple approach based on standard immunoassay technology that is easy and quick to perform. It relies on the effect that the molar IC50 approaches the Kd value in the case of infinitely small concentrations of the reagents. A two-dimensional dilution of the reagents leads to an asymptotic convergence to Kd. The approach has some similarity to the well-known checkerboard titration used for the optimization of immunoassays. A well-known antibody against the FLAG peptide, clone M2, was used as a model system and the results were compared with other methods. This approach could be used in any case where a competitive assay is available or can be developed. The determination of an affinity constant should belong to the crucial parameters in any quality control of antibody-related products and assays and should be mandatory in papers using immunochemical protocols.
Thousands of antibodies for diagnostic and other analytical purposes are on the market. However, it is often difficult to identify duplicates, reagent changes, and to assign the correct original publications to an antibody. This slows down scientific progress and might even be a cause of irreproducible research and a waste of resources. Recently, activities were started to suggest the sole use of recombinant antibodies in combination with the open communication of their sequence. In this case, such uncertainties should be eliminated. Unfortunately, this approach seems to be rather a long-term vision since the development and manufacturing of recombinant antibodies remain quite expensive in the foreseeable future. Nearly all commercial antibody suppliers also may be reluctant to publish the sequence of their antibodies, since they fear counterfeiting. De novo sequencing of antibodies is also not feasible today for a reagent user without access to the hybridoma clone. Nevertheless, it seems to be crucial for any scientist to have the opportunity to identify an antibody undoubtedly to guarantee the traceability of any research activity using antibodies from a third party as a tool. For this purpose, we developed a method for the identification of antibodies based on a MALDI-TOF MS fingerprint. To circumvent lengthy denaturation, reduction, alkylation, and enzymatic digestion steps, the fragmentation was performed with a simple formic acid hydrolysis step. Eighty-nine unknown monoclonal antibodies were used for this study to examine the feasibility of this approach. Although the molecular assignment of peaks was rarely possible, antibodies could be easily recognized in a blinded test, simply from their mass-spectral fingerprint. A general protocol is given, which could be used without any optimization to generate fingerprints for a database. We want to propose that, in most scientific projects relying critically on antibody reagents, such a fingerprint should be established to prove and document the identity of the used antibodies, as well as to assign a specific reagent to a datasheet of a commercial supplier, public database record, or antibody ID.
Antibody-gated indicator delivery (gAID) systems based on mesoporous silica nano- and microparticle scaffolds are a promising class of materials for the sensitive chemical detection of small-molecule analytes in simple test formats such as lateral flow assays (LFAs) or microfluidic chips. Their architecture is reminiscent of drug delivery systems, only that reporter molecules instead of drugs are stored in the voids of a porous host particle. In addition, the pores are closed with macromolecular “caps” through a tailored “gatekeeping” recognition chemistry so that the caps are opened when an analyte has reacted with a “gatekeeper”. The subsequent uncapping leads to a release of a large number of indicator molecules, endowing the system with signal amplification features. Particular benefits of such systems are their modularity and adaptability. With the example of the immunochemical detection of type-I pyrethroids by fluorescent dye-releasing gAID systems, the influence of several tuning modes on the optimisation of such hybrid sensory materials is introduced here. In particular, different mesoporous silica supports (from nano- and microparticles to platelets and short fibres), different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in the absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material's pore opening, the better the closing/opening mechanism can be controlled. Because such materials are well-suited for LFAs, performance assessment included a test-strip format besides conventional assays in suspension. In combination with dyes as indicators and smartphones for read-out, simple analytical tests for use by untrained personnel directly at a point-of-need such as an aeroplane cabin can be devised, allowing for sensitivities down to the μg kg−1 range in <5 min with case-required selectivities.