Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (72)
Sprache
- Englisch (70)
- Deutsch (1)
- Mehrsprachig (1)
Referierte Publikation
- ja (72) (entfernen)
Schlagworte
- ELISA (12)
- Mass spectrometry (7)
- Affinity chromatography (6)
- Lab-on-a-chip (6)
- Nitrotyrosine (6)
- Antibody (5)
- Fluorescence (5)
- Immunoassay (5)
- LC-MS/MS (5)
- Tyrosine (5)
- Air pollution (4)
- HPLC (4)
- Metrology (4)
- Nitration (4)
- Reference material (4)
- Allergy (3)
- Amino acid analysis (3)
- Biosensor (3)
- Biosensors (3)
- Caffeine (3)
- Immunoassays (3)
- Monoclonal antibody (3)
- Nitrogen oxides (3)
- PCR (3)
- Peptides (3)
- Phenylalanine (3)
- Quality control (3)
- Reproducibility (3)
- Screening (3)
- Terrorism (3)
- Traceability (3)
- AAA (2)
- Affinity extraction (2)
- Albumin (2)
- Animal species differentiation (2)
- Aromatic amino acid analysis (2)
- BSA (2)
- Biochip (2)
- Biophotonics (2)
- Carbamazepine (2)
- Carrier protein (2)
- Chromatography (2)
- Combinatorial chemistry (2)
- Copper (2)
- Degradation (2)
- Diagnostics (2)
- Dimer (2)
- Dityrosine (2)
- Documentation (2)
- Explosives detection (2)
- Fish species (2)
- Fluoreszenz (2)
- HTS (2)
- Hapten (2)
- Hybridoma (2)
- Hydrolysis (2)
- IgG (2)
- Immunogen (2)
- LAMP (2)
- MALDI (2)
- Magnetic resonance imaging (2)
- Microarray (2)
- Microfluidics (2)
- Miniaturization (2)
- Mobile phase (2)
- Monolithic column (2)
- Multiplexing (2)
- Nickel (2)
- Open Science (2)
- Optical sensors (2)
- Oxidation (2)
- Ozone (2)
- Peptide (2)
- Peptide library (2)
- Permethrin (2)
- Photonic sensors (2)
- Protein (2)
- Protein nitration (2)
- Quality Control (2)
- Quantitative protein analysis (2)
- Reference materials (2)
- Ring resonator (2)
- SBA-15 (2)
- SPR (2)
- Sapphire (2)
- Security (2)
- Sequence coverage (2)
- Sequencing (2)
- Silanization (2)
- Silicon photonics (2)
- Synthetic peptides (2)
- TATP (2)
- Tryptophan (2)
- Validation (2)
- immunoassay (2)
- 150th anniversary (1)
- 150th anniversary of BAM (1)
- 2,5-dihydroxyacetophenone (1)
- 280 nm (1)
- 3R concept (1)
- 6xHis (1)
- AAAA (1)
- ABC (1)
- ABID (1)
- ADC (1)
- ATCUN (1)
- Aautomatisation (1)
- Absorption (1)
- Acute myocardial infarction (1)
- Additive Manufacturing (1)
- Adhesion (1)
- Adhesives (1)
- Adjuvantien (1)
- Adsorption (1)
- Aeroallergens (1)
- Affinity (1)
- Affinity Chromatography (1)
- Affinity Extraction (1)
- Affinity Separation (1)
- Affinity immobilization (1)
- Aflatoxin (1)
- Air filter samples (1)
- Air particulate matter (1)
- Air-segmented flow (1)
- Airport (1)
- Alanine scan (1)
- Algal toxins (1)
- Allergene (1)
- Allergie (1)
- Aluminum oxide (1)
- Ambient ionization (1)
- Amplification (1)
- Analysis (1)
- Analytical sciences (1)
- Anatoxin-a (1)
- Anatoxin-a(s) (1)
- Animal welfare (1)
- Anthropocene (1)
- Anthropogenic markers (1)
- Antibodies (1)
- Antibody Purification (1)
- Antibody antigen complex (1)
- Antibody drug conjugate (1)
- Antibody identification (1)
- Antibody quality (1)
- Antibody-gated indicator delivery (1)
- Antibody-gated indicator delivery systems (1)
- Antigen (1)
- Array (1)
- Atmospheric aerosol (1)
- Augenbohne (1)
- Automated Purification (1)
- Aviation (1)
- BAM (1)
- BCA test (1)
- BODIPY-Farbstoffe (1)
- Back-side integration (1)
- Bacterial lysates (1)
- Basic solvent (1)
- Benchmarking study (1)
- Benzene-1,3,5-tricarboxylic acid (1)
- Bet v 1 (1)
- Betula pendula (1)
- Binder (1)
- Binding molecule (1)
- Binding strength (1)
- Bio-interaction (1)
- Bioanalysis (1)
- Biochemistry (1)
- Bioconjugate (1)
- Bioinformatics (1)
- Bioluminescence (1)
- Biomarker (1)
- Biosensing (1)
- Biosensor development (1)
- Bioseparation (1)
- Biotechnology (1)
- Biotoxins (1)
- Birch pollen allergen (1)
- Block copolymer (1)
- Blue-green algae (1)
- Bombs (1)
- Borosilicate Glass (1)
- Bovine serum albumin (1)
- Bovine serum albumin (BSA) (1)
- Bradford (1)
- Bundesanstalt für Materialforschung und -prüfung (1)
- Byproducts (1)
- COVID-19 (1)
- Calibration (1)
- Carbamazepin (1)
- Cardiac troponin (1)
- Cardiovascular (1)
- Carrier (1)
- Carrier load (1)
- Certified reference materials (1)
- Cetirizin (1)
- Cetirizine (1)
- Chelate (1)
- Chemical evolution (1)
- Chemical protein modification (1)
- Chemiluminescence (1)
- Chemosensor (1)
- Chicken antibodies (1)
- Chip (1)
- Chirality (1)
- Chronic kidney disease (1)
- Citation (1)
- Citizen Science (1)
- Cleavage (1)
- Click chemistry (1)
- Click reaction (1)
- Clone M2 (1)
- Collection (1)
- Column holder (1)
- Combinatorial peptide library (1)
- Combinatorial polymer libraries (1)
- Combustion (1)
- Commercialization (1)
- Compartmentalization (1)
- Competitive immunoassay (1)
- Compound-independent calibration (1)
- Concentration step (1)
- Conformation (1)
- Conjugates (1)
- Conjugation density (1)
- Conjugation ratio (1)
- Construction (1)
- Continuous Sensor (1)
- Contrast agent (1)
- Coproantibodies (1)
- Corona virus (1)
- Corundum (1)
- Cross-linking (1)
- Cyanotoxins (1)
- Cylindrospermopsin (1)
- Cytochrome P450 CYP1A2 (1)
- Cytoplasm (1)
- DAMP (1)
- DAR (1)
- DHAP (1)
- DNA chip (1)
- DNA-Chip (1)
- Damage-associated molecular patterns (DAMPs) (1)
- De novo peptide sequencing (1)
- Deep learning-based tools (1)
- Dendrimer (1)
- Derivatization (1)
- Diagnosis (1)
- Diagnostic Antibodies (1)
- Diesel (1)
- Diesel exhaust (1)
- Digital PCR (1)
- Digital immunoassay (1)
- Digitale PCR (1)
- Dimerization (1)
- Dissociation constant (1)
- Dityrosine crosslinking (1)
- Docking (1)
- Down Stream Processing (1)
- Downstream processing (1)
- Drug (1)
- Drug discovery (1)
- Drug transporters (1)
- Drug-to-antibody ratio (1)
- EDTAD (1)
- ELISA methods (1)
- ESI MS (1)
- Editorial (1)
- Elastin-specific contrast agent ESMA (1)
- Element Specific Bioimaging Using Laser Ablation (1)
- Emergency (1)
- Enantiomeric excess ee (1)
- Encapsulation (1)
- Enhancement (1)
- Environment (1)
- Environmental analysis (1)
- Environmental monitoring (1)
- Environmental pollutants (1)
- Enzyme-linked immunosorbent assay (1)
- Epoxy (1)
- Equilibrium constant (1)
- Error correction (1)
- Escherichia coli (1)
- Ethylenediaminetetraacetic acid (1)
- Etofenprox (1)
- Exhaust (1)
- Experiment (1)
- Explosive (1)
- FLAG peptide (1)
- FPLC (1)
- Farbstoffe (1)
- Feces (1)
- Fischarten (1)
- Flow injection immunoassay (1)
- Fluorescence label (1)
- Folding chirality (1)
- Formulation additives (1)
- Fragmentation (1)
- Functionalization (1)
- Gadofosveset (1)
- Gadolinium-based contrast agent (1)
- Gadovist (1)
- Gated hybrid material (1)
- Gated materials (1)
- Github (1)
- Glass Support (1)
- Glue (1)
- Glutaraldehyde (1)
- Glycidylethers (1)
- Grass pollen (1)
- HPLC-DAD (1)
- Hapten immunoassay (1)
- Harmful algal blooms (1)
- Hay fever (1)
- Heart attack (1)
- Heavy chains (1)
- Heterologous hapten (1)
- HexaHis-Tag (1)
- High pH (1)
- High-Speed (1)
- High-Speed Separations (1)
- High-throughput (1)
- His6 (1)
- His8 (1)
- Histidine (1)
- Human Plasma (1)
- Hybridisierung (1)
- Hydrochloric acid (1)
- Hydroxyl radicals (1)
- IC50 (1)
- IMAC purification (1)
- Identity (1)
- IgE (1)
- IgG determination (1)
- IgY (1)
- Iinductively coupled plasma mass spectrometry (1)
- Immunization monitoring (1)
- Immunoaffinity extraction (1)
- Immunocapture (1)
- Immunochemical response optimization (1)
- Immunoglobulin E (1)
- Immunoglobulins (1)
- Immunometric assay (1)
- Immunometric biosensor (1)
- Immunosensor (1)
- Impact (1)
- Impurites (1)
- Inductively Coupled Mass Spectroscopy (1)
- Inflammation (1)
- Inhibition (1)
- Insecticide (1)
- Interlaboratory studies (1)
- Internal standard (1)
- Iron disorders (1)
- Isotope dilution (1)
- Jahrestag (1)
- Kjeldahl (1)
- Klimaveränderung (1)
- Kreuzreaktivität (1)
- LC-MS (1)
- LC-UV absorbance (1)
- LCMSMS (1)
- LIF (1)
- Lab-on-a-Chip (1)
- Lab-on-chip (1)
- Label (1)
- Laborvergleichuntersuchungen (1)
- Ladder sequencing (1)
- Ladungstransfer (1)
- Lanthanide DOTA (1)
- Lanthaniden (1)
- Laser (1)
- Laser-induced fluorescence (1)
- Laser-induced plasma (1)
- Lateral flow assay (1)
- Lateral flow test (1)
- Lead identification (1)
- Library (1)
- Life sciences (1)
- Light chain (1)
- Light chains (1)
- Limit of detection (1)
- Linker (1)
- Liquid chromatography (1)
- Liver function tests (1)
- Low-cost (1)
- Luftverschmutzung (1)
- Luminol (1)
- MALDI-TOF (1)
- MALDI-TOF MS (1)
- MR Angiography (1)
- MST (1)
- Macroporous polymers (1)
- Mass Spectrometry (1)
- Massenspektrometrie (1)
- Material sciences (1)
- Material-binding Peptides (1)
- Mechanism (1)
- Mesoporous particles (1)
- Mesoporöse Materialien (1)
- Metal labeling (1)
- Metall-Markierung (1)
- Metalloprotein (1)
- Method (1)
- Microarrays (1)
- Microcystins (1)
- Microfluidic mixing (1)
- Microfluidic system (1)
- Micrometeorites (1)
- Microresonator (1)
- Microwave (1)
- Milch (1)
- Miller and Urey (1)
- Missing fragmentation sites (1)
- Molecular-MRI (1)
- Molekularbiologie (1)
- Monoclonal Antibodies (1)
- Monoclonal Antibody (1)
- Monoclonal antibodies (1)
- Monolith (1)
- Multiplex (1)
- Multiplex methods (1)
- Murchison meteorite (1)
- Mycotoxin (1)
- NHS (1)
- NHS-Ester (1)
- NIR-Farbstoffe (1)
- NIST (1)
- NIST-mAb 8671 (1)
- Nanocarrier (1)
- Nanoparticle (1)
- Nanoparticles (1)
- Nanophotonics (1)
- Nanoscience (1)
- Natural products (1)
- Neoallergen (1)
- Neoepitopes (1)
- Nickel chelate (1)
- Nitrogen dioxide (1)
- Nodularins (1)
- Nonspecific binding (NSB) (1)
- Nucleocapsid (1)
- OBOC library (1)
- Oligomer (1)
- Oligomerization (1)
- On-chip screening (1)
- One-bead-one-compound library (1)
- Online biosensor (1)
- Online detection (1)
- Open science (1)
- Optical detection (1)
- Optoelectronic (1)
- Orbitrap (1)
- Organic peroxides (1)
- Oriented immobilization (1)
- Ortho-Phthalaldehyde (1)
- Ovalbumin (1)
- Ozon (1)
- PALM (1)
- PEG (1)
- PIC technology (1)
- Partikel (1)
- Pattern recognition receptor (1)
- Peer review (1)
- Peptide Library (1)
- Peptide analysis (1)
- Peptide aptamers (1)
- Peptide binder (1)
- Peptide folding (1)
- Peptide library screening (1)
- Peptide losses (1)
- Peptide mass fingerprinting (1)
- Peroxidase (1)
- Pesticide (1)
- Pflanzenvirus (1)
- Pharmaceutical (1)
- Pharmaceuticals (1)
- Phenothrin (1)
- Phenylketonuria (1)
- Phl p 5 (1)
- Phleum pratense (1)
- Photonic biosensor (1)
- Plant virus (1)
- Plastics (1)
- Point of inflection (1)
- Polishing (1)
- Pollen (1)
- Pollen extract (1)
- Pollutant (1)
- Polyclonal Antibodies (1)
- Polyethers (1)
- Polyethylene glycol (1)
- Polyglycerol (1)
- Polymer-binding Peptides (1)
- Polymers (1)
- Polypropylene (1)
- Porous rock (1)
- Prebiotic chemistry (1)
- Precision polymer sequencing (1)
- Preprocessing (1)
- Primer (1)
- Primordial soup (1)
- Protein A (1)
- Protein Purification (1)
- Protein analysis (1)
- Protein conjugation (1)
- Protein content (1)
- Protein degradation (1)
- Protein folding (1)
- Protein hydrolysis (1)
- Protein nitration degree (1)
- Protein oligomer analysis (1)
- Protein oligomerization (1)
- Protein oligomers (1)
- Protein quantification (1)
- Protein test (1)
- Protein-Quantifizierung (1)
- Proteinoid (1)
- Proteins (1)
- Proteomics (1)
- Pseudo peptides (1)
- Purification (1)
- Purity (1)
- Pyrethroid (1)
- QC (1)
- Quality assurance (1)
- Qualitätskontrolle (1)
- Quantitative proteomics (1)
- RBD (1)
- Racemate (1)
- Reagenzien (1)
- Real-time measurement (1)
- Recombinant Antibody (1)
- Recombinant antibody (1)
- Recombinant protein (1)
- Recovery (1)
- References (1)
- Referenzmaterialien (1)
- Regeneration (1)
- Reinheitsbestimmung (1)
- Replication (1)
- Replication crisis (1)
- Reproducibility crisis (1)
- Resonance wavelength shift (1)
- Ring resonators (1)
- Robustness (1)
- Round robin exercise (1)
- SBA-16 (1)
- SI traceability (1)
- Saliva (1)
- Saxitoxins (1)
- Schlangenbohne (1)
- Schnellmethoden (1)
- Scientific publication (1)
- Segregation (1)
- Self-assembled monolayers (SAM) (1)
- Self-assembly (1)
- Semtex (1)
- Sensor (1)
- Sequence-defined oligomer (1)
- Sequencing algorithm (1)
- Signal amplification (1)
- Single molecule (1)
- Sintered Material (1)
- Size exclusion chromatography (1)
- Smartphone readout device (1)
- Software (1)
- Solid-binding Peptides (1)
- Solid-phase extraction (SPE) (1)
- Solubilizer (1)
- Special issue (1)
- Spike protein (1)
- Sprengstoffe (1)
- Stable isotope labeling (1)
- Standardisation (1)
- Standardisierung (1)
- Standardverfahren (1)
- Stickoxide (1)
- Structure (1)
- Sulfo-NHS (1)
- Sulfur (1)
- Surface Activation (1)
- Surface chemistry (1)
- Surface plasmon resonance (1)
- Surface water (1)
- Surface-plasmon resonance (1)
- Surrogate citations (1)
- TLR4 activation (1)
- Target (1)
- Terephthalic acid (1)
- Test midpoint (1)
- Test strip analysis (1)
- Tetranitromethane (1)
- Therapeutic Antibodies (1)
- Tholins (1)
- Toll-like receptor 4 (1)
- Topical collection: Analytical Methods and Applications in the Materials and Life Sciences (1)
- Toxicity (1)
- Toxicity test (1)
- Triacetone triperoxide (1)
- Trimer (1)
- Tripeptides (1)
- Trust (1)
- Tryptic digest (1)
- Type-I pyrethroids (1)
- Ultrasensitive (1)
- Upscaling (1)
- Vibrio fischeri (1)
- Vigna unguiculata (1)
- Visualization (1)
- Wastewater marker (1)
- Water (1)
- Waveguide (1)
- Wipe test (1)
- Zenodo (1)
- antibody (1)
- bioisosteric replacement (1)
- cross-reactivity (1)
- explosives (1)
- hapten (1)
- irreproducibility (1)
- ligand binding assay (1)
- monoclonal antibody (1)
- non-specific binding (1)
- pH-Abhängigkeit (1)
- paper retraction (1)
- peer reviewimmunochemistry (1)
- quality control (1)
- replication (1)
- reproducibility crisis (1)
- security (1)
- selectivity (1)
- self-replication (1)
- terrorism (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (41)
- 1.5 Proteinanalytik (41)
- 1.1 Anorganische Spurenanalytik (6)
- 1.9 Chemische und optische Sensorik (6)
- 6 Materialchemie (6)
- 6.3 Strukturanalytik (5)
- 1.8 Umweltanalytik (4)
- 1.4 Prozessanalytik (2)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
- VP Vizepräsident (2)
The employment of type-I pyrethroids for airplane disinfection in recent years underlines the necessity to develop sensing schemes for the rapid detection of these pesticides directly at the point-of-use. Antibody-gated indicator-releasing materials were thus developed and implemented with test strips for lateral-flow assay-based analysis employing a smartphone for readout. Besides a proper matching of pore sizes and gating macromolecules, the functionalization of both the material's outer surface as well as the strips with PEG chains enhanced system performance. This simple assay allowed for the detection of permethrin as a target molecule at concentrations down to the lower ppb level in less than 5 minutes.
In this work, a cost-effective optofluidic system is proposed and preliminary experimental results are presented. A microfluidic channel monolithically integrated into a photonic integrated circuit technology is used in conjunction with a cyclic olefin copolymer (COC) substrate to provide fluidic in- and output ports. We report on initial experimental results as well as on the simple and cost-effective fabrication of this optofluidic system by means of micro-milling.
Set them free: Brightly fluorescent indicators that are loaded into mesoporous silica nanoparticle carriers, capped with bulky antibodies, are released into the lateral flow of a test strip upon analyte arrival. Integration of the system into a rapid, simple flow test with fluorescence readout is applied for the selective and sensitive determination of the presence of triacetone triperoxide (TATP) as a prototype small-molecule analyte (see figure).
Silicon photonic micro-ring resonators (MRR) developed on the silicon-on-insulator (SOI) platform, owing to their high sensitivity and small footprint, show great potential for many chemical and biological sensing applications such as label-free detection in environmental monitoring, biomedical engineering, and food analysis. In this tutorial,we provide the theoretical background and give design guidelines for SOI-based MRR as well as examples of surface functionalization procedures for label-free detection of molecules. After introducing the advantages and perspectives of MRR, fundamentals of MRR are described in detail, followed by an introduction to the fabrication methods, which are based on a complementary metal-oxide semiconductor (CMOS) technology. Optimization of MRR for chemical and biological sensing is provided, with special emphasis on the optimization of waveguide geometry. At this point, the difference between chemical bulk sensing and label-free surface sensing is explained, and definitions like waveguide sensitivity, ring sensitivity, overall sensitivity as well as the limit of detection (LoD) of MRR are introduced. Further, we show and explain chemical bulk sensing of sodium chloride (NaCl) in water and provide a recipe for label-free surface sensing.
MALDI-TOF-MS-Based Identification of Monoclonal Murine Anti-SARS-CoV-2 Antibodies within One Hour
(2022)
During the SARS-CoV-2 pandemic, many virus-binding monoclonal antibodies have been developed for clinical and diagnostic purposes. This underlines the importance of antibodies as universal bioanalytical reagents. However, little attention is given to the reproducibility crisis that scientific studies are still facing to date. In a recent study, not even half of all research antibodies mentioned in publications could be identified at all. This should spark more efforts in the search for practical solutions for the traceability of antibodies. For this purpose, we used 35 monoclonal antibodies against SARS-CoV-2 to demonstrate how sequence-independent antibody identification can be achieved by simple means applied to the protein. First, we examined the intact and light chain masses of the antibodies relative to the reference material NIST-mAb 8671. Already half of the antibodies could be identified based solely on these two parameters. In addition, we developed two complementary peptide mass fingerprinting methods with MALDI-TOF-MS that can be performed in 60 min and had a combined sequence coverage of over 80%. One method is based on the partial acidic hydrolysis of the protein by 5 mM of sulfuric acid at 99 degrees C. Furthermore, we established a fast way for a tryptic digest without an alkylation step. We were able to show that the distinction of clones is possible simply by a brief visual comparison of the mass spectra. In this work, two clones originating from the same immunization gave the same fingerprints. Later, a hybridoma sequencing confirmed the sequence identity of these sister clones. In order to automate the spectral comparison for larger libraries of antibodies, we developed the online software ABID 2.0. This open-source software determines the number of matching peptides in the fingerprint spectra. We propose that publications and other documents critically relying on monoclonal antibodies with unknown amino acid sequences should include at least one antibody fingerprint. By fingerprinting an antibody in question, its identity can be confirmed by comparison with a library spectrum at any time and context.
The allergenic and inflammatory potential of proteins can be enhanced by chemical modification upon exposure to atmospheric or physiological oxidants. The molecular mechanisms and kinetics of such modifications, however, have not yet been fully resolved. We investigated the oligomerization and nitration of the grass pollen allergen Phl p 5 by ozone (O3), nitrogen dioxide (NO2), and peroxynitrite (ONOO–). Within several hours of exposure to atmospherically relevant concentration levels of O3 and NO2, up to 50% of Phl p 5 were converted into protein oligomers, likely by formation of dityrosine cross-links. Assuming that tyrosine residues are the preferential site of nitration, up to 10% of the 12 tyrosine residues per protein monomer were nitrated. For the reaction with peroxynitrite, the largest oligomer mass fractions (up to 50%) were found for equimolar concentrations of peroxynitrite over tyrosine residues. With excess peroxynitrite, the nitration degrees increased up to 40% whereas the oligomer mass fractions decreased to 20%. Our results suggest that protein oligomerization and nitration are competing processes, which is consistent with a two-step mechanism involving a reactive oxygen intermediate (ROI), as observed for other proteins. The modified proteins can promote pro-inflammatory cellular signaling that may contribute to chronic inflammation and allergies in response to air pollution.
Chemical modification by peroxynitrite enhances TLR4 activation of the grass pollen allergen Phl p 5
(2023)
The chemical modification of aeroallergens by reactive oxygen and nitrogen species (ROS/RNS) may contribute to the growing prevalence of respiratory allergies in industrialized countries. Post-translational modifications can alter the immunological properties of proteins, but the underlying mechanisms and effects are not well understood. In this study, we investigate the Toll-like receptor 4 (TLR4) activation of the major birch and grass pollen allergens Bet v 1 and Phl p 5, and how the physiological oxidant peroxynitrite (ONOO–) changes the TLR4 activation through protein nitration and the formation of protein dimers and higher oligomers. Of the two allergens, Bet v 1 exhibited no TLR4 activation, but we found TLR4 activation of Phl p 5, which increased after modification with ONOO– and may play a role in the sensitization against this grass pollen allergen. We attribute the TLR4 activation mainly to the two-domain structure of Phl p 5 which may promote TLR4 dimerization and activation. The enhanced TLR4 signaling of the modified allergen indicates that the ONOO–-induced modifications affect relevant protein-receptor interactions. This may lead to increased sensitization to the grass pollen allergen and thus contribute to the increasing prevalence of allergies in the Anthropocene, the present era of globally pervasive anthropogenic influence on the environment.
Rapid testing methods for the use directly at apointof need are expected to unfold their true potential especiallywhen offering adequate capabilities for the simultaneousmeasurement of multiple analytes of interest. Considering theunique modularity,high sensitivity,and selectivity of antibody-gated indicator delivery (gAID) systems,amultiplexed assayfor three small-molecule explosives (TATP, TNT,PETN) wasthus developed, allowing to detect the analytes simultaneouslywith asingle test strip at lower ppb concentrations in the liquidphase in < 5min using afluorescence reader or asmartphonefor readout. While the TNT and PETN systems were newlydeveloped here,all the three systems also tolerated harshermatrices than buffered aqueous model solutions.Besidesasingle-track strip,the outstanding modularity of the hybridbiosensor materials in combination with strip-patterningtechnologies allowed us to obtain amultichannel strip inastraightforwardmanner,offering comparable analyticalperformance while allowing to be tailored even more to theusersneed.
The Protocol Gap
(2021)
Although peer review is considered one of the main pillars of modern science, experimental methods and protocols seem to be not a rigorous subject of this process in many papers. Commercial equipment, test kits, labeling kits, previously published concepts, and standard protocols are often considered to be not worth a detailed description or validation. Even more disturbing is the extremely biased citation behavior in this context, which sometimes leads to surrogate citations to avoid low-impact journals, preprints, or to indicate traditional practices. This article describes some of these surprising habits and suggests some measures to avoid the most unpleasant effects, which in the long term may undermine the credibility of science as a whole.
An improved antibody against the explosive pentaerythritol tetranitrate (PETN) was developed. The immunogen was designed by the concept of bioisosteric replacement, which led to an excellent polyclonal antibody with extreme selectivity and immunoassays of very good sensitivity. Compounds such as nitroglycerine, 2,4,6-trinitrotoluene, 1,3,5-trinitrobenzene, hexogen (RDX), 2,4,6-trinitroaniline, 1,3-dinitrobenzene, octogen (HMX), triacetone triperoxide (TATP), ammonium nitrate, 2,4,6-trinitrophenol and nitrobenzene were tested for potential cross-reactivity. The detection limit of a competitive enzyme-linked immunosorbent assay (ELISA) was determined to be around 0.5 µg/L. The dynamic range of the assay was found to be between 1 µg/L and 1000 µg/L, covering a concentration range of three decades. This work shows the successful application of the bioisosteric concept in immunochemistry by exchange of a nitroester to a carbonate diester. The antiserum might be used for the development of quick tests, biosensors, microtitration plate immunoassays, microarrays and other analytical methods for the highly sensitive detection of PETN, an explosive frequently used by terrorists, exploiting the extreme difficulty of its detection.
Environmental pollutants like fine particulate matter can cause adverse health effects through oxidative stress and inflammation. Reactive oxygen and nitrogen species (ROS/RNS) such as peroxynitrite can chemically modify proteins, but the effects of such modifications on the immune system and human health are not well understood. In the course of inflammatory processes, the Toll-like receptor 4 (TLR4) can sense damage-associated molecular patterns (DAMPs). Here, we investigate how the TLR4 response and pro-inflammatory potential of the proteinous DAMPs α-Synuclein (α-Syn), heat shock protein 60 (HSP60), and high-mobility-group box 1 protein (HMGB1), which are relevant in neurodegenerative and cardiovascular diseases, changes upon chemical modification with peroxynitrite.
For the peroxynitrite-modified proteins, we found a strongly enhanced activation of TLR4 and the pro-inflammatory transcription factor NF-κB in stable reporter cell lines as well as increased mRNA expression and secretion of the pro-inflammatory cytokines TNF-α, IL-1β, and IL-8 in human monocytes (THP-1). This enhanced activation of innate immunity via TLR4 is mediated by covalent chemical modifications of the studied DAMPs.
Our results show that proteinous DAMPs modified by peroxynitrite more potently amplify inflammation via TLR4 activation than the native DAMPs, and provide first evidence that such modifications can directly enhance innate immune responses via a defined receptor. These findings suggest that environmental pollutants and related ROS/RNS may play a role in promoting acute and chronic inflammatory disorders by structurally modifying the body's own DAMPs. This may have important consequences for chronic neurodegenerative, cardiovascular or gastrointestinal diseases that are prevalent in modern societies, and calls for action, to improve air quality and climate in the Anthropocene.
Quantitative proteomics is a growing research area and one of the most important tools in the life sciences. Well-characterized and quantified protein standards are needed to achieve accurate and reliable results. However, only a limited number of sufficiently characterized protein standards are currently available. To fill this gap, a method for traceable protein quantification using sulfur isotope dilution inductively coupled plasma mass spectrometry (ICP-MS) was developed in this study.
Gel filtration and membrane filtration were tested for the separation of non-protein-bound sulfur in the protein solution.
Membrane filtration demonstrated a better performance due to the lower workload and the very low sulfur blanks of 11 ng, making it well suited for high-purity proteins such as NIST SRM 927, a bovine serum albumin (BSA). The method development was accomplished with NIST SRM 927e and a commercial avidin. The quantified mass fraction of NIST SRM 927e agreed very well with the certified value and showed similar uncertainties (3.6%) as established methods while requiring less sample preparation and no species-specific standards. Finally, the developed procedure was applied to the tau protein, which is a biomarker for a group of neurodegenerative diseases denoted “tauopathies” including, e.g., Alzheimer’s disease and frontotemporal dementia. For the absolute quantification of tau in the brain of transgenic mice overexpressing human tau, a well-defined calibration standard was needed. Therefore, a pure tau solution was quantified, yielding a protein mass fraction of (0.328 ± 0.036) g/kg, which was confirmed by amino acid analysis.
Fast and accurate determination of the protein content of a sample is an important and non-trivial task of many biochemical, biomedical, food chemical, pharmaceutical, and environmental research activities. Different methods of total protein determination are used for a wide range of proteins with highly variable properties in complex matrices. These methods usually work reasonably well for proteins under controlled conditions, but the results for non-standard and complex samples are often questionable. Here, we compare new and well-established methods, including traditional amino acid analysis (AAA), aromatic amino acid analysis (AAAA) based on the amino acids phenylalanine and tyrosine, reversed-phase liquid chromatography of intact proteins with UV absorbance measurements at 220 and 280 nm (LC-220, LC-280), and colorimetric assays like Coomassie Blue G-250 dye-binding assay (Bradford) and bicinchoninic acid (BCA) assay. We investigated different samples, including proteins with challenging properties, chemical modifications, mixtures, and complex matrices like air particulate matter and pollen extracts. All methods yielded accurate and precise results for the protein and matrix used for calibration. AAA, AAAA with fluorescence detection, and the LC-220 method yielded robust results even under more challenging conditions (variable analytes and matrices). These methods turned out to be well-suited for reliable determination of the protein content in a wide range of samples, such as air particulate matter and pollen.
Comprehensive evaluation of peptide de novo sequencing tools for monoclonal antibody assembly
(2023)
Monoclonal antibodies are biotechnologically produced proteins with various applications in research, therapeutics and diagnostics. Their ability to recognize and bind to specific molecule structures makes them essential research tools and therapeutic agents. Sequence information of antibodies is helpful for understanding antibody–antigen interactions and ensuring their affinity and specificity. De novo protein sequencing based on mass spectrometry is a valuable method to obtain the amino acid sequence of peptides and proteins without a priori knowledge. In this study, we evaluated six recently developed de novo peptide sequencing algorithms (Novor, pNovo 3, DeepNovo, SMSNet, PointNovo and Casanovo), which were not specifically designed for antibody data. We validated their ability to identify and assemble antibody sequences on three multi-enzymatic data sets. The deep learning-based tools Casanovo and PointNovo showed an increased peptide recall across different enzymes and data sets compared with spectrum-graph-based approaches. We evaluated different error types of de novo peptide sequencing tools and their performance for different numbers of missing cleavage sites, noisy spectra and peptides of various lengths. We achieved a sequence coverage of 97.69–99.53% on the light chains of three different antibody data sets using the de Bruijn assembler ALPS and the predictions from Casanovo. However, low sequence coverage and accuracy on the heavy chains demonstrate that complete de novo protein sequencing remains a challenging issue in proteomics that requires improved de novo error correction, alternative digestion strategies and hybrid approaches such as homology search to achieve high accuracy on long protein sequences.
A 2-dimensional high-throughput screening method is presented to select peptide sequences from large peptide libraries for precision formulation additives, having a high capacity to specifically host a drug of interest and provide tailored drug release properties. The identified sequences are conjugated with poly(ethylene glycol) (PEG) to obtain peptide-PEG conjugates that proved to be valuable as solubilizers for small organic molecule drugs to overcome limitations of poor water-solubility and low bio-availability. The 2D-screening method selects peptide sequences on both (i) high loading capacities and (ii) preferred drug-release capabilities as demonstrated on an experimental Tau-protein aggregation inhibitor/Tau- deaggregator with potentials for an anti-Alzheimer disease drug (BB17). To enable 2D-screening, a one-bead one-compound (OBOC) peptide library was immobilized on a glass slide, allocating individual beads to permanent positions. While the first screening step involved incubation of the supported OBOC library with BB17 to identify beads with high drug binding capacities by fluorescence scanner readouts, the second step reveals release properties of the high capacity binders by incubation with blood plasma protein model solutions. Efficiently peptides with high BB17 capacities and either keeper or medium or fast releaser properties can be identified by direct sequence readouts from the glass slide supported resin beads via matrix-assisted laser desorption/ionization time-of-flight tandem mass spectrometry. Four peptides are synthesized as peptide-PEG solubilizers representing strong, medium, weak releasers and non-binders. Loading capacities reached up to 1:3.4 (mol drug per mol carrier) and release kinetics (fast/medium/slow) are in agreement with the selection process as investigated by fluorescence anisotropy and fluorescence correlation spectroscopy. The ability of BB17/conjugate complexes to inhibit the aggregation of Tau4RDΔK (four repeat Tau ((M)Q244-E372 with deletion of K280), 129 residues) in N2a cells is studied by a Tau-pelleting assay showing the modulation of cellular Tau aggregation. Promising effects such as the reduction of 55% of total Tau load are observed for the strong releaser additive. Studies of in vitro Thioflavin S Tau-aggregation assays show half-maximal inhibitory activities (IC50 values) of BB17/conjugates in the low micro-molar range.
A new class of boron-dipyrromethene (BDP or BODIPY) dyes was obtained by phenanthrene fusion to the β-pyrrole positions, absorbing in the wavelength range of important laser sources. Despite a 'propeller-like' distorted structure in the crystalline state, the chromophore absorbs (log ε ≥ 5) and fluoresces (Φf ≥ 0.8) strongly and can be easily turned into a fluorescence light-up probe. Incorporation into latex beads produces bright and photostable single-dye and Förster Resonance Energy Transfer (FRET) particles for microscopy applications.
Mass spectrometry-based methods play a crucial role in the quantification of the main iron metabolism regulator hepcidin by singling out the bioactive 25-residue peptide from the other naturally occurring N-truncated isoforms (hepcidin-20, -22, -24), which seem to be inactive in iron homeostasis. However, several difficulties arise in the MS analysis of hepcidin due to the sticky character of the peptide and the lack of suitable standards. Here, we propose the use of amino- and fluoro-silanized autosampler vials to reduce hepcidin interaction to laboratory glassware surfaces after testing several types of vials for the preparation of stock solutions and serum samples for isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Furthermore, we have investigated two sample preparation strategies and two chromatographic separation conditions with the aim of developing an LC-MS/MS method for the sensitive and reliable quantification of hepcidin-25 in serum samples. A chromatographic separation based on usual acidic mobile phases was compared with a novel approach involving the separation of hepcidin-25 with solvents at high pH containing 0.1% of ammonia. Both methods were applied to clinical samples in an intra-laboratory comparison of two LC-MS/MS methods using the same hepcidin-25 calibrators with good correlation of the results. Finally, we recommend an LC-MS/MS-based quantification method with a dynamic range of 0.5–40 μg/L for the assessment of hepcidin-25 in human serum that uses TFA-based mobile phases and silanized glass vials.
An airborne high repetition rate laser-induced plasma was applied as a versatile ambient ionization source for mass-spectrometric determinations of polar and nonpolar analytes in solution. The laser plasma was sustained between a home-built pneumatic nebulizer and the inlet capillary of an Orbitrap mass spectrometer. To maintain stable conditions in the droplet-rich spray environment, the plasma was directly fed by the fundamental output (λ = 1064 nm) of a current state-of-the-art diode-pumped solid-state laser. Ionization by the laser-driven plasma resulted in signals of intact analyte ions of several chemical categories. The analyte ions were found to be fully desolvated since no further increase in ion signal was observed upon heating of the inlet capillary. Due to the electroneutrality of the plasma, both positive and negative analyte ions could be formed simultaneously without altering the operational parameters of the ion source. While, typically, polar analytes with pronounced gas phase basicities worked best, nonpolar and amphoteric compounds were also detected. The latter were detected with lower ion signals and were prone to a certain degree of fragmentation induced during the ionization process. All the described attests the laser-induced microplasma by a good performance in terms of stability, robustness, sensitivity, and general applicability as a self-contained ion source for the liquid sample introduction.
Nonporous corundum powder, known as an abrasive material in the industry, was functionalized covalently with protein binders to isolate and enrich specific proteins from complex matrices. The materials based on corundum were characterized by TEM, ESEM, BET, DLS, EDS, and zeta potential measurements. The strong Al-O-P bonds between the corundum surface and amino phosphonic acids were used to introduce functional groups for further conjugations. The common crosslinker glutaraldehyde was compared with a hyperbranched polyglycerol (PG) of around 10 kDa. The latter was oxidized with periodate to generate aldehyde groups that can covalently react with the amines of the surface and the amino groups from the protein via a reductive amination process. The amount of bound protein was quantified via aromatic amino acid analysis (AAAA). This work shows that oxidized polyglycerol can be used as an alternative to glutaraldehyde. With polyglycerol, more of the model protein bovine serum albumin (BSA) could be attached to the surface under the same conditions, and lower non-specific binding (NSB) was observed. As a proof of concept, IgG was extracted with protein A from crude human plasma. The purity of the product was examined by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). A binding capacity of 1.8 mg IgG per gram of corundum powder was achieved. The advantages of corundum include the very low price, extremely high physical and chemical stability, pressure resistance, favorable binding kinetics, convenient handling, and flexible application.
Quantitative 1H nuclear magnetic resonance (qNMR) of aromatic amino acids for protein quantification
(2023)
Hydrolysis of protein samples into amino acids facilitates the use of NMR spectroscopy for protein and peptide quantification. Different conditions have been tested for quantifying aromatic amino acids and proteins. The pH-dependent signal shifts in the aromatic region of amino acid samples were examined. A pH of 12 was found to minimize signal overlap of the four aromatic amino acids. Several aromatic compounds, such as terephthalic acid, sulfoisophthalic acid, and benzene tricarboxylic acid, were applied as internal standards. The quantification of amino acids from an amino acid standard was performed. Using the first two suggested internal standards, recovery was ~97% for histidine, phenylalanine, and tyrosine at a concentration of approximately 1 mM in solution. Acidic hydrolysis of a certified reference material (CRM) of bovine serum albumin (BSA) and subsequent quantification of Phe and Tyr yielded recoveries of 98% ± 2% and 88% ± 4%, respectively, at a protein concentration of 16 g/L or 250 µM.