Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (73)
- Beitrag zu einem Tagungsband (46)
- Zeitschriftenartikel (40)
- Beitrag zu einem Sammelband (35)
- Posterpräsentation (11)
- Forschungsbericht (7)
- Buchkapitel (2)
- Sonstiges (2)
Schlagworte
- Radar (21)
- Zerstörungsfreie Prüfung (17)
- Alkali-Kieselsäure-Reaktion (16)
- Beton (16)
- Betonfahrbahndecke (13)
- Radiografie (12)
- AKR (11)
- Acoustic emission (9)
- Strukturaufklärung (9)
- Concrete (8)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (73)
The recommendation is based on the co-authors’ work organized by the RILEM TC 256-SPF “Spalling of concrete due to fire: testing and modelling”. It aims to provide useful information, guidance and best practices in fire spalling assessment to laboratories that perform large-scale tests based on fire resistance test standards. It provides guidance on the spalling observation techniques during testing, as well as post-test spalling quantification/assessment methods. This document is intended to be used in conjunction with the fire resistance test standards, e.g. EN 1363-1 and ISO 834-1.
An den vor allem vor 2006 errichteten Betonfahrbahndecken sind in den letzten Jahren vermehrt AKR-Schäden aufgetreten. Vor diesem Hintergrund wurde durch das BMVBS das ARS 04/2013 erlassen. Dieses wiederum sieht verbindlich im Vorfeld des Neubaus und der Erneuerung von Fahrbahndecken aus Beton im deutschen Bundesautobahnnetz einen Eignungsnachweis für die Gesteinskörnungen vor. Das hatte in den Folgejahren eine drastische Reduzierung der einsatzbaren Gesteinskörnungen zur Folge. Vor diesem Hintergrund wird in dem Beitrag die Leistungsfähigkeit der Innenhydrophobierung als neuartige AKR-Vermeidungsstrategie zur Nutzbarmachung grenzwertig alkaliempfindlicher Gesteinskörnungen aufgezeigt. Dabei wird ein Einblick in die Ergebnisse zweier aufeinander aufbauender BASt-Forschungsvorhaben gegeben. Den Schwerpunkt bildet hierbei die Bewertung des Einflusses der Dosierung des Hydrophobierungsmittels auf die Frisch- und Festbetoneigenschaften im Rahmen von Basisuntersuchungen im Labor. Aufbauend darauf wird das Prüfprogramm eines großmaßstäblichen Technikumsversuchs und der aktuelle Stand der Umsetzung aufgezeigt.
Concrete pavement surface textures are divided by means of their dimension into four categories: microtexture, macrotexture, megatexture and roughness. They influence the most important performance characteristics of road surfaces, such as friction (also referred to as “skid resistance”), tire/pavement noise, evenness and surface drainage. These properties are relevant for driving safety, comfort and environmental aspects. Up to now, research in Germany has focused on monitoring these characteristics by tire/pavement noise and skid resistance measurements. However, the topography of surface textures has not been sufficiently investigated and evaluated until now. The development and availability of high-performance, hand-held 3D scanning systems during the last years enable measurements of the microtexture and macrotexture of concrete pavement surfaces at short measuring times and high resolution.
This paper shows the ability of modern laser-based technology to record three-dimensional data of different concrete pavement surface textures in situ. For this purpose, a special measuring frame has been developed. The presented results were primarily obtained within the framework of a research project commissioned by the German Federal Highway Research Institute (BASt) and processed by the Federal Institute for Materials Research and Testing. Various concrete pavement surface textures by means of diamond grinding and hybrid of diamond grinding and grooving were investigated in situ. In addition, exposed aggregate concretes (EAC), which were introduced as a standard type of concrete for motorway pavements in Germany in 2006, have been analyzed. Based on the gathered 3D data, evaluation routines for qualitative and quantitative analysis have been developed and applied. The aim was to derive the statistical parameters such as the relative and cumulative frequency distribution of the profile depth as well as the roughness coefficient for diamond ground pavements and EAC. Also, the “mean profile depth” (MPD) as a common texture-related parameter was determined.
Bewertung der Innenhydrophobierung als neuartige AKR-Vermeidungsstrategie bei Betonfahrbahndecken
(2023)
Zur Vermeidung von AKR-Schäden an Betonfahrbahndecken im deutschen Autobahnnetz wurden mit dem ARS 04/2013 verbindliche Eignungsprüfungen zum Ausschluss alkaliempfindlicher Gesteinskörnungen bei Neubau- und Erhaltungsmaßnahmen eingeführt. Das hatte eine signifikante Reduzierung geeigneter Gesteinskörnungen zur Folge. Deshalb wird geprüft, ob durch die Zugabe eines Hydrophobierungsmittels während der Betonherstellung grenzwertig alkaliempfindliche Gesteinskörnungen nutzbar gemacht werden können. In diesem Beitrag wird der Einfluss der Dosierung eines Compounds mit Hydrophobierungsmittel (HM) auf die Frisch- und Festbetoneigenschaften eines Waschbetons mit einer reaktiven Grauwacke dargestellt. Es zeigt sich, dass aufgrund des Antagonismus die zunehmende Dosierung des HM-Compounds eine signifikante Erhöhung der Zugabe des Luftporenbildners auf Wurzelharzbasis erfordert. Der AKR-Schädigungsprozess wird ab einer Dosierung des HM-Compounds von 0,75 M.-%, bezogen auf den Zementgehalt, hinreichend vermindert. Die mechanischen Eigenschaften des hydrophobierten Waschbetons verschlechtern sich im betrachteten Dosierungsbereich des HM-Compounds nur geringfügig. Auch der Frost-Tausalz-Widerstand vermindert sich, ohne den normativen Grenzwert für die Abwitterung zu überschreiten.
Bewertung der Innenhydrophobierung als neuartige AKR-Vermeidungsstrategie bei Betonfahrbahndecken
(2023)
Zur Vermeidung von AKR-Schäden an Betonfahrbahndecken im deutschen Autobahnnetz wurden mit dem ARS 04/2013 verbindliche Eignungsprüfungen zum Ausschluss alkaliempfindlicher Gesteinskörnungen bei Neubau- und Erhaltungsmaßnahmen eingeführt. Das hatte eine signifikante Reduzierung geeigneter Gesteinskörnungen zur Folge. Deshalb wird geprüft, ob durch die Zugabe eines Hydrophobierungsmittels während der Betonherstellung grenzwertig alkaliempfindliche Gesteinskörnungen nutzbar gemacht werden können. In diesem Beitrag wird der Einfluss der Dosierung eines Compounds mit Hydrophobierungsmittel (HM) auf die Frisch- und Festbetoneigenschaften eines Waschbetons mit einer reaktiven Grauwacke dargestellt. Es zeigt sich, dass aufgrund des Antagonismus die zunehmende Dosierung des HM-Compounds eine signifikante Erhöhung der Zugabe des Luftporenbildners auf Wurzelharzbasis erfordert. Der AKR-Schädigungsprozess wird ab einer Dosierung des HM-Compounds von 0,75 M.-%, bezogen auf den Zementgehalt, hinreichend vermindert. Die mechanischen Eigenschaften des hydrophobierten Waschbetons verschlechtern sich im betrachteten Dosierungsbereich des HMCompounds nur geringfügig. Auch der Frost-Tausalz-Widerstand vermindert sich, ohne den normativen Grenzwert für die Abwitterung zu überschreiten.
Alkali-silica reaction (ASR) is a chemical reaction within concrete which can lead over time to cracking and spalling. Due to the complexity of the problem, it still causes damage to concrete constructions worldwide.
The publication aims to illustrate the interdisciplinary research of the German Federal Institute for Materials Research and Testing (BAM) within the last 20 years, considering all aspects of ASR topics from the macro to the micro level. First, methods for characterization and assessment of ASR risks and reaction products used at BAM are explained and classified in the international context. Subsequently the added value of the research approach by combining different, preferably nondestructive, methods across all scales is explained using specific examples from a variety of research projects. Aspects covered range from the development of new test-setups to assess aggregate reactivity, to analysis of microstructure and reaction products using microscopical, spectroscopical and X-ray methods, to the development of a testing methodology for existing concrete pavements including in-depth analysis of the visual damage indicator and the de-icing salt input using innovative testing techniques. Finally, research regarding a novel avoidance strategy that makes use of internal hydrophobization of the concrete mix is presented.
Für die rechnerische Dimensionierung der Betondecken im Oberbau von Verkehrsflächen für den Neubau sowie die Erneuerung nach RDO-Beton 09 ist die statische Spaltzugfestigkeit an der unteren und oberen Bohrkernscheibe entsprechend der Vorgaben der AL Sp-Beton zu bestimmen. Aufgrund der unzureichenden Kenntnis der Präzision dieses Prüfverfahrens wurden, basierend auf dem Entwurf des FGSV-Merkblatts zur statistischen Auswertung von Prüfergebnissen, mit einem breit aufgestellten Ringversuch die statistischen Kennwerte an Labor- und Bestandsbetonen unter Vergleich- und Wiederholbedingungen ermittelt. Zur möglichst guten statistischen Absicherung nahmen an dem Ringversuch dreizehn erfahrene Prüfstellen teil, die vorab einem Audit unterzogen wurden. Zur Abdeckung des vielschichtigen Einsatzes des Prüfverfahrens erfolgte der Ringversuch an acht Prüflosen, die sowohl die Erst-/ Eignungsprüfung und Übereinstimmungskontrolle bei Neubaumaßnahmen, als auch die Restsubstanzbewertung von Betonfahrbahnplatten berücksichtigen. Zur Bewertung des Materialeinflusses wurde zusätzlich ein Prüflos mit Labormörtel untersucht.
Die Probenvorbereitung erfolgte zentral an der BAM. Zur Sicherstellung einheitlicher Prüfbedingungen bei den Prüfstellen wurde zusätzlich eine detaillierte Standardarbeitsanweisung erarbeitet, die partiell bereits Eingang in das Normenwerk gefunden hat. Bei der Plausibilitätsprüfung aller prüflosspezifischen Einzelwerte der Spaltzug- und Druckfestigkeit wurden vereinzelt sowohl Ausführungsfehler als auch Übertragungs- und Tippfehler festgestellt. Der sich anschließende Lilliefors-Test zeigt, dass die ermittelten Einzelwerte bis auf wenige Aus-nahmen normalverteilt sind und damit die Voraussetzungen für die statistische Auswertung gegeben sind.
Mittels grafischer Darstellung der Mandel’s h- und k-Werte wurden die Auffälligkeiten hinsichtlich der Mittelwerte und Varianzen prüflosspezifisch für die einzelnen Prüfstellen visualisiert und anschließend einige von ihnen mittels Grubbs- und Cochran-Test als Ausreißer identifiziert. Nach Ausreißerelimination wurde mit dem klassischen Verfahren bei der Spaltzugfestigkeit der geringste Variationskoeffizient unter Vergleich- und Wiederholbedingungen bei der Erst-/Eignungsprüfung mit 6,2 und 6,4 Prozent ermittelt. Bei einer Verminderung des Materialeinflusses durch die Verwendung eines Labormörtels verbessern sich die statistischen Kennwerte auf 4,5 und 5,3 Prozent. Mit 8,2 und 9,5 Prozent beziehungsweise 8,6 und 9,5 Prozent werden bei der Restsubstanzbewertung von Wasch- und Unterbetonen die höchsten Werte bestimmt.
Das robuste Auswerteverfahren (ohne Eliminierung der Ausreißer) nach dem Entwurf des FGSV-Merkblatts zur statistischen Auswertung von Prüfergebnissen erwies sich in der Form als ungeeignet und bedurfte einer Überarbeitung. Bezüglich der vergleichend mit klassischen und robusten Verfahren gewonnenen Kennwerte ist festzustellen, dass bei sehr homogenen Messergebnissen eines Prüfloses beide Verfahren nahezu die gleichen statistischen Kennwerte liefern. Bei der Eliminierung von Ausreißern sind die Ergebnisse des robusten Verfahrens in der Regel etwas größer als die des klassischen Verfahrens.
Die begleitenden vertiefenden Untersuchungen bei der Spaltzugprüfung mit innovativen Prüftechniken lieferten wertvolle Erkenntnisse zur Bewertung der Prüfeinflüsse.
Bewertung der Innenhydrophobierung von Fahrbahndeckenbetonen als neuartige AKR-Vermeidungsstrategie
(2022)
Zur Nutzbarmachung grenzwertig alkaliempfindlicher Gesteinskörnungen für Betonfahrbahndecken wurde basierend auf einer Literaturrecherche die Eignung von je einem Innenhydrophobierungsmittel auf der Basis eines Kalziumstearats (HM-A), eines Silan-Siloxan-Gemisches (HM-B) sowie eines der Vertraulichkeit unterliegenden Wirkstoffs (HM-C) für die neuartige AKR-Vermeidungsstrategie untersucht. Die Basis für die Eignungsuntersuchungen bildeten die Rezepturen im ARS 04/2013 für den OB (D>8)/UB sowie für den OB 0/8. Zur Herausarbeitung des Einflusses des Hydrophobierungsmittels auf die schädigende AKR fand in der groben Kornfraktionen ein alkaliempfindlicher Grauwackesplitt Anwendung. Aufgrund der unterschiedlichen Wechselwirkung zwischen dem LP-Bildner und dem Hydrophobierungsmittel wurde seine Dosierung beim HM-A reduziert sowie beim HM-B geringfügig und beim HM-C um ein Vielfaches erhöht.
Ausgehend von den ausgewählten Rezepturen mit den unterschiedlichen Hydrophobierungsmitteln wurden bei den Untersuchungen u.a. folgende Erkenntnisse gewonnen:
• Nachweis der Funktionalität aller drei Hydrophobierungsmittel im Festbeton durch signifikant reduzierte kapillare Aufnahme der Prüflösung.
• Verschlechterung der mechanischen Eigenschaften und des Frost-Tausalzwiderstands des OB (D>8)/UB bei Zugabe aller Hydrophobierungsmittel.
• Verzicht auf den Einsatz des HM-A im OB (D>8)/UB aufgrund drastischer Verschlechterung der Verarbeitbarkeit des Frischbetons und hohem Festigkeitsverlust.
• Verzicht auf den Einsatz des HM-B im OB (D>8)/UB aufgrund der Überschreitung des Dehnungsgrenzwerts nach dem 9. bzw. 10. Zyklus (mit bzw. ohne zyklischer Vorschädigung) und der einhergehenden starken Abwitterung bei der KWL mit NaCl-Lösung.
• Nachweis nachhaltiger Verminderung schädigender AKR in beiden Betonarten mit HM-C in Klimawechsellagerung und 60°C-Betonversuch mit externer Alkalizufuhr, allerdings zu Lasten der mechanischen Eigenschaften und des Frost-Tausalz-Widerstands.
Fazit: Bei geeigneter Wirkstoffauswahl hat die Innenhydrophobierung das Potenzial für die Nutzbarmachung grenzwertiger Gesteinskörnung. Ihre Überführung in die Praxis erfordert jedoch eine weitere ganzheitliche Optimierung der Baustoffperformance. Das schließt auch die Verifizierung gezielter betontechnologischer Maßnahmen zur Verminderung der Verschlechterung der mechanischen Eigenschaften und des Frost-Tausalz-Widerstandes ein.
Ausgehend von den verstärkt auftretenden AKR-Schäden an den vor 2005 hergestellten BAB-Abschnitten verfolgte das Forschungsvorhaben zwei Ziele. So sollte einerseits die Ursache für die mit der AKR-Schadensentwicklung einhergehende Dunkelfärbung der Oberfläche der Betonfahrbahndecke im Fugenbereich ermittelt werden. Andererseits galt es, ausgehend von der Zustands- und Schadenserfassung das AKR-Restschädigungspotenzial der Prüfkörper aus je drei ein- und zweischichtig ausgeführten, unterschiedlich stark AKR-geschädigten BAB-Abschnitten vergleichend zu bewerten. Folgende Ergebnisse wurden u. a. erzielt:
1. Dunkelfärbung Experimenteller Nachweis mit kombinierter insitu-
Feuchtemessung mit Radar (integral) und NMR (tiefenaufgelöst), dass Dunkelfärbung der Oberfläche der Betonfahrbahndecke im Fugenbereich auf eine erhöhte Durchfeuchtung der Betonrandzone zurückzuführen ist; erfolgreiche Validierung der ZfP-Ergebnisse mit Darr-Wäge-Versuch.
2. Zustand beprobter BAB-Abschnitte und schadenskategoriespezifische
Bewertung der AKR-Prüfverfahren:
• Auffinden von Horizontalrissen im Bereich der Querscheinfuge bei allen AKR-geschädigten BAB-Abschnitten,
• Ermittlung mittlerer Eindringtiefen bei Natrium von maximal 20 bis 45 mm und bei Chlorid von maximal 15 bis 60 mm im Entnahmezustand;
keine Korrelation mit der AKR-Schadenskategorie des jeweiligen BAB-Abschnitts,
• Nachweis gleichzeitig auftretender SEB bei allen AKR-geschädigten BAB-Abschnitten im Entnahmezustand,
• keine signifikante Verminderung der Spaltzugfestigkeit durch die verstärkte AKR am Plattenrand,
• Ermittlung eines erhöhten AKR-Restschädigungspotenzials bei vier der sechs beprobten BAB-Abschnitte primär mittels AKR-erformanceprüfungen,
• Ermittlung höherer Dehnungen bei Performanceprüfungen aus Ober- und Unterbeton bestehenden Halbschalen, als an separat aus Ober- und Unterbeton gewonnenen Prismen,
• Unauffälliges Verhalten nahezu aller bei der Performanceprüfung auffälligen Bestandsbetone im 40°C- und 60°C-Betonversuch; vermutete Ursache: mit LIBS nachgewiesene hohe und tiefreichende Auslaugung der Alkalien.
Analyse des gefügeabhängigen Löslichkeitsverhaltens potenziell AKR-empfindlicher Gesteinskörnungen
(2021)
Das gefügeabhängige Löslichkeitsverhalten wurde an folgenden vier Gesteinskörnungen unterschiedlicher Alkaliempfindlichkeitsklassen
untersucht:
• GK1 (EIII-S): quarzreicher Kies
• GK2 (EIII-S): Grauwacke (Splitt)
• GK3 (EI-S): Quarz-Feldspat-Porphyr (Splitt)
• GK4 (EI-S): sandsteinreicher Kies
DiePorenstrukturanalyse erfolgte sowohl an Einzelkörnern mittels vergleichender 3D-CT und BET- Untersuchungen als auch an Korngemengen der einzelnen Kornfraktionen (außer Fraktion 16/22 mm) über die Wasseraufnahme und mit BET. Für die Visualisierung und Quantifizierung der von außen zugänglichen Oberflächenanteile der Einzelkörner wurde ein Softwaretool entwickelt, erprobt und erfolgreich angewandt. Es gelang so u.a. den Nachweis zu erbringen, dass die gebrochenen Einzelkörner der Grauwacke und des Rhyoliths einen deutlich geringeren von außen zugänglichen Oberflächenanteil als die gleichartigen Gesteinskörner aus dem Kies besitzen. Aufgrund der limitierten Ortsauflösung der 3D-CT von 11 bis 16,5 μm wurde mit BET eine um drei Zehnerpotenzen höhere spezifische Oberfläche ermittelt.
Zu den Porositätsuntersuchungen an den Korngemengen sei angemerkt, dass zum Teil gegenläufige Trends zwischen offener Porosität und spezifischer Oberfläche festgestellt wurden. Dieses ist beim Bezug des bei den Löseversuchen in 0,1 M KOH mit definierter NaCl-Zugabe aus der Gesteinskörnung gelösten SiO2 und Al2O3 von zentraler Bedeutung. Bei den Löseversuchen an den fraktionsspezifischen Korngemengen selbst zeigte sich, dass die stufenweise Erhöhung des NaCl-Gehalts von 0 auf 10 M.-% im Eluat eine erhöhte SiO2-Löslichkeit und eine verminderte Auslaugung von Al2O3 zur Folge hat. Auffallend war hierbei, dass die Al2O3-Löslichkeit bei GK4 ohne und mit geringer NaCl-Zugabe die mit Abstand höchsten Werte annimmt. Bei den zusätzlich durchgeführten Löseversuchen an den tomografierten Einzelkörnern in 1 M KOH-Lösung mit Zugabe von 1 M.-% NaCl zeigte sich, dass nur vereinzelt bei den untersuchten Gesteinsarten eine Korrelation zwischen dem SiO2- bzw. Al2O3-Gehalt im Eluat und der absoluten BET-Oberfläche nachweisbar ist. Dies ist vermutlich darauf zurückzuführen, dass neben der Oberfläche weitere Parameter (z.B. die mineralogische Zusammensetzung der Einzelkörner) das Löseverhalten maßgebend beeinflussen. Bei den parallel zu den Löseversuchen durchgeführten Betonversuchen nach dem ARS 04/2013 zeigte sich, dass die Alkaliempfindlichkeit der GK4 bei beiden Betonversuchen mit Alkalizufuhr unterschiedlich zu bewerten ist. So ist unabhängig von der vorgegebenen pessimalen Betonrezeptur des Fahrbahndeckenbetons ausschließlich bei der Klimawechsellagerung die GK4 als alkaliempfindlich einzustufen. Allerdings konnte der Befund der stark ausgeprägten AKR bei der GK4 mit der Dünnschliffmikroskopie nicht bestätigt werden. Analoges gilt für die Bewertung der Alkaliempfindlichkeit von GK2 mit den Betonversuchen nach der Alkalirichtlichtlinie des DAfStb. So ist auch hier die GK2 nicht im 60 °C-Betonversuch sondern ausschließlich im 40 °C-Betonversuch als alkaliempfindlich einzustufen.
Dienach den verschiedenartigen Betonversuchen durchgeführten LIBS-Analysen am Vertikalschnitt der Prüfkörper zeigen, dass im Kernbereich nach dem 60 °C-Betonversuch mit 10 %iger NaCl-Lösung und nach der Klimawechsellagerung mit NaCl-Beaufschlagung annähernd gleich hohe Natrium- und Chloridgehalte vorgefunden werden. Wider Erwarten treten an den beaufschlagten Prüfflächen Abreicherungen von Natrium und Anreicherungen von Chlorid auf. Im 40°C- und 60 °C-Betonversuch wurde das Natrium bis in eine maximale Tiefe von ca. 30 mm bzw. 20 mm ausgelaugt. Die aufbauenden korrelativen Betrachtungen zwischen den Ergebnissen des 60°C Betonversuchs mit Alkalizufuhr und der Löseversuche an den fraktionsspezifischen Korngemengen in 1 M KOH-Lösung mit definierter NaCl-Zugabe sind durchaus vielversprechend. So zeigt sich beispielsweise beim Waschbeton, dass der fraktionsspezifisch gewichtete SiO2-Überschuss im Eluat nach 56 Tagen mit Zugabe von 0,5 M.-% NaCl ohne Bezug auf die BET-Oberfläche zur gleichen Einstufung der vier betrachteten Gesteinskörnungen wie bei den Dehnungen im 60 °C-Betonversuch mit 3 %-iger NaCl-Lösung führt. Außerdem korrelieren die im 60 °C-Betonversuch mit 10 %-iger NaCl-Lösung ermittelten Dehnungen mit dem gewichteten SiO2-Überschuss im Eluat bei Zugabe von 2 M.-% NaCl ohne Bezug auf die BET-Oberfläche.
Ausschließlich bei den Betonversuchen nach der Alkali-Richtlinie erwies sich der Bezug des im Eluat ermittelten SiO2-Überschusses auf die BET-Oberfläche als zielführend. Aufgrund des Potenzials der Löseversuche mit NaCl-Zugabe für die Bewertung der Alkaliempfindlichkeit der Gesteinskörnung im Fahrbahndeckenbeton wird empfohlen, die vergleichenden Untersuchungen zwischen den Löseversuchen an Korngemischen der einzelnen Fraktionen und den Betonversuchen nach dem ARS 04/2013 mit einer möglichst hohen Anzahl an Gesteinskörnungen und einem präzisierten Untersuchungsumfang fortzuführen.
To prevent future alkali-aggregate reaction (AAR) damage, which has occurred frequently in the Germanhighway network in recent years, a new regulation has been drafted. This regulation severely limits the use of alkali-sensitive aggregates by requiring that their suitability be verified by certified inspectors using newly developed AAR concrete tests that involve the external supply of alkali. This has led to a significant limitation in the number of aggregates usable for concrete pavements. A novel AAR avoidance strategy is now being pursued, which aims to enable the use of borderline alkali-sensitive aggregates through the application of an internal water-repellent treatment. The addition of water repellents during concrete production should significantly reduce the ingress of water and external de-icing salts into the concrete pavement, thus reducing the potential for AAR damage.
This paper presents the results of laboratory tests to assess the suitability of this new AAR prevention strategy. Representative, highly AAR-susceptible road paving concrete made with an alkali- sensitive greywacke and various water repellents were used as the basis for these experiments. The tests for concrete suitability included determining the conventional fresh and hardened concrete properties as well as concrete prism tests with external alkaline supply. Building on these results, laser-induced breakdown spectroscopy (LIBS) analyses of de-icing-salt intrusion as well as microscopic examinations for verification of the AAR characteristics were carried out.
The results of the AAR concrete tests with external alkaline supply support the conclusion that, when hydrophobic agents containing a suitable active ingredient are used, the AAR damage process in road paving concrete can be sufficiently prevented.
The durability of concrete structures due to alkali-silica-reaction (ASR) is usually been assessed by ASR concrete prism tests (CPT). Therefore, the expansion of concrete specimens indicates an alkalisensitivity.
In Germany these tests are performed at 40°C or accelerated 60°C. Nevertheless, ASR prism tests are expensive, power and time-consuming. For these reasons, an alternative chemical test (“mod. BTU-test”) was developed in the past. The “mod. BTU-test” was correlated with German standard CPT.
In this test, the solubility of silica and alumina in the liquid phase is measured by ICP-OES.
For special requirements in concrete road construction, stricter test procedures are necessary. The specimens are repeatedly subjected to cyclic alternating storage in NaCl. On the one hand, the presence of NaCl increases the ASR expansion, on the other hand NaCl also changes the dissolution behaviour of silica and alumina.
For now is not possible to correlate the solubilities of “mod. BTU-test” and ASR expansions influenced by NaCl. Therefore, four aggregates with different ASR sensitivities were chosen and ASR concrete prism tests (in addition with NaCl) have been performed. According to the “mod. BTU-test” the solubilities of silica and alumina in presence of different NaCl concentrations were measured.
This paper is about the regression analysis of silica and alumina dissolution and ASR expansion tests in presence of NaCl. The regression analysis shows the influence of a quasi-continuous and an interrupted cyclic alternating storage. Additionally the effects of temperature and NaCl concentration are investigated. In the end, a suitable NaCl concentration of the “mod. BTU-test” for dissolution experiments is recommended. The “mod. BTU-Test” with NaCl might be a serious and reliable test method for ASR classification for concrete road construction.
Um die zunehmenden AKR-Schäden an Betonfahrbahnen im deutschen Autobahnnetz zukünftig zu vermeiden, wurden mit dem ARS 04/2013 verbindliche Eignungsprüfungen zum Ausschluss alkaliempfindlicher Gesteinskörnungen bei Neubau- und Erhaltungsmaßnahmen eingeführt. Dies führte zu einer deutlichen Reduzierung der geeigneten Gesteinskörnungen. Vor diesem Hintergrund soll durch die Zugabe eines Innenhydrophobierungsmittels während der Betonherstellung grenzwertig alkaliempfindliche Gesteinskörnung nutzbar gemacht werden.
Die AKR-Vermeidungsstrategie basiert dabei auf der signifikanten Reduzierung des Eindringens von Wasser und Tausalzlösung in den Fahrbahndeckenbeton. In einem im Aufträge der BASt an der BAM durchgeführten Forschungsvorhaben wurde die Leistungsfähigkeit verschiedener Hydrophobierungsmittel für diesen Einsatzzweck
grundhaft untersucht. In dem Beitrag wird exemplarisch die Leistungsfähigkeit eines geeigneten Hydrophobierungsmittels in einem Waschbeton mit einer sehr alkaliempfindlichen Grauwacke aufgezeigt. Das Spektrum der Laboruntersuchungen reicht dabei von AKR-Betonversuchen mit Alkalizufuhr sowie den aufbauend durchgeführten mikroskopischen Untersuchungen zur Bewertung des AKR-Schädigungspotenzials über die Analyse des Feuchte- und Tausalzeintrags bis zur Ermittlung der mechanischen Eigenschaften und des Frost-Tausalz-Widerstands.
Abschließend wird der noch vorhandene Forschungsbedarf zur Überführung dieser neuen AKR-Vermeidungsstrategie in die Praxis aufgezeigt.
Am Ende des 19. und zu Beginn des 20. Jahrhunderts wurden auch in Berlin vermehrt Fassadenverblendung aus Eifeler Tuffsteinen errichtet. Die Eifeler Tuffsteine zeichnen sich aufgrund ihrer hohen Porosität einerseits durch eine gute Verarbeitbarkeit aus. Andererseits sind sie nur schwach gebunden und besitzen deshalb eine geringe Verwitterungsbeständigkeit.
Vielleicht nannten es die Berliner „Puppen putzen“, wenn in den 1880er Jahren die Marmorstatuen auf der Schlossbrücke vor dem Berliner Stadtschloss mit Bürste, Wasser und Seife von Staub, Ruß und Taubendreck befreit wurden. Soviel Pflege wurde diesen Göttinnen aus der griechischen Mythologie nicht immer zuteil. So haben Klima, Luftverschmutzung und der 2. Weltkrieg, wie bei anderen Kunstwerken auch, tiefe Spuren hinterlassen. Der Erhalt dieser zwischen 1847 und 1857 aufgestellten Skulpturen und vieler vergleichbarer Objekte im Stadtbild ist durch die auch heute weiter fortschreitende Schädigung des Marmors gefährdet. In den Jahren 2006 bis 2010 förderte die Deutsche Bundesstiftung Umwelt (DBU) ein Projekt zur „Entwicklung und Überprüfung von Einhausungssystemen zur Reduzierung umweltbedingter Schädigungen von außenexponierten Marmorobjekten mit dem Ziel des langfristigen Erhalts in situ an einem national bedeutenden Objektkomplex, den Schlossbrückenfiguren unter den Linden, Berlin“. Geleitet und restauratorisch betreut wurde das Projekt durch das Landesdenkmalamt (LDA) Berlin. Durch die Abteilung Strukturgeologie und Geodynamik (GZG) der Georg-August Universität Göttinnen wurden die Verwitterungsmechanismen des Marmors untersucht und auf dieser Basis Anforderungen an das Schutzsystem formuliert. Anhand von numerischen Simulationen des Instituts für Bauklimatik der Technischen Universität Dresden (TUD) wurde das bauphysikalische Konzept des Einhausungssystems optimiert. Die konstruktive Gestaltung eines Prototyps und des finalen Entwurfs erfolgte durch das Fachgebiet Konstruktives Entwerfen und Tragwerkslehre der Universität der Künste Berlin. Durch den Fachbereich Baustoffe der BAM erfolgten die Realisierung des Prototyps der Einhausung sowie ein umfangreiches Klimamonitoring an den Skulpturen. Anhand dieses interdisziplinären Projektes und ergänzt durch weitere Messungen wird gezeigt, mit welchen Methoden die für die Degradation von Marmor relevanten Mechanismen untersucht werden können. Die Erkenntnisse aus dem Projekt sind die Grundlage für die Entwicklung nachhaltiger Pflege- und Schutzkonzepte für die kulturhistorisch wertvollen Skulpturen. Nur mit solchen modernen konservatorischen Programmen können die Originalskulpturen im Berliner Stadtraum erlebbar bleiben.
Das Pergamonmuseum ist eines der am meisten besuchten Museen Berlins. Es wird seit etwa 20 Jahren im Rahmen des 1999 von der Stiftung Preußischer Kulturbesitz beschlossenen Masterplans Museumsinsel schrittweise grundhaft instandgesetzt und um einen weiteren Flügel ergänzt, der 2025 fertig gestellt sein soll. In diesem Kontext wurde auch kurz nach dem Beschluss des Masterplans eine Bauzustandsanalyse an den in Originalgröße in der Antikensammlung ausgestellten Baudenk¬ mälern durchgeführt. Allerdings stellte man dabei fest, dass herkömmliche Erkundungsverfahren wie die Bauaufnahme, die baugeschichtliche Untersu¬ chung, das Quellenstudium sowie die äußerliche Begutachtung nicht ausreichen, um die innere Struktur der antiken Baudenkmäler hinreichend zu charakterisieren. Deshalb wurde die BAM im Jahr 2003 von der ARGE Pfanner Pergamonmuseum
beauftragt, in enger Zusammenarbeit mit zwei Ingenieurbüros, dem Ingenieurbüro Patitz (IGP) und der Gesellschaft für geophysikalische Unter¬ suchungen mbH (GGU) unter Hinzuziehung einer Restauratorin, die innere Struktur ausgewählter an¬ tiker Baudenkmäler zerstörungsfrei zu untersuchen. Das Ziel der zerstörungsfreien Strukturaufklärung zum inneren Aufbau der Bauteile war es, einerseits sicherheitsrelevante Informationen für die statische Nachweisführung bereitzustellen, sowie andererseits eine Planungsgrundlage für die eventuell erforder¬ liche Ertüchtigung der Baudenkmäler zu schaffen. Im Fokus der Untersuchungen standen dabei das Markttor von Milet und das Säulenjoch der Heiligen Halle am Markt von Priene1 • Im nachstehenden Beitrag werden exemplarisch die am Markttor von Milet durchgeführten Untersuchungen vorgestellt.
Das Pergamonmuseum ist eines der am meisten besuchten Museen Berlins. Es wird seit etwa 20 Jahren im Rahmen des 1999 von der Stiftung Preußischer Kulturbesitz beschlossenen Masterplans Museumsinsel schrittweise grundhaft instandgesetzt und um einen weiteren Flügel ergänzt, der 2025 fertig gestellt sein soll. In diesem Kontext wurde auch kurz nach dem Beschluss des Masterplans eine Bauzustandsanalyse an den in Originalgröße in der Antikensammlung ausgestellten Baudenk¬ mälern durchgeführt. Allerdings stellte man dabei fest, dass herkömmliche Erkundungsverfahren wie die Bauaufnahme, die baugeschichtliche Untersu¬ chung, das Quellenstudium sowie die äußerliche Begutachtung nicht ausreichen, um die innere Struktur der antiken Baudenkmäler hinreichend zu charakterisieren. Deshalb wurde die BAM im Jahr 2003 von der ARGE Pfanner Pergamonmuseum beauftragt, in enger Zusammenarbeit mit zwei Ingenieurbüros, dem Ingenieurbüro Patitz (IGP) und der Gesellschaft für geophysikalische Unter¬ suchungen mbH (GGU) unter Hinzuziehung einer Restauratorin, die innere Struktur ausgewählter an¬ tiker Baudenkmäler zerstörungsfrei zu untersuchen. Das Ziel der zerstörungsfreien Strukturaufklärung zum inneren Aufbau der Bauteile war es, einerseits sicherheitsrelevante Informationen für die statische Nachweisführung bereitzustellen, sowie andererseits eine Planungsgrundlage für die eventuell erforder¬ liche Ertüchtigung der Baudenkmäler zu schaffen. Im Fokus der Untersuchungen standen dabei das Markttor von Milet und das Säulenjoch der Heiligen Halle am Markt von Priene1 • Im nachstehenden Beitrag werden exemplarisch die am Markttor von Milet durchgeführten Untersuchungen vorgestellt.
Am Ende des 19. und zu Beginn des 20. Jahrhunderts wurden auch in Berlin vermehrt Bauwerke mit einer Fassadenverblendung aus Eifeler Tuffsteinen errichtet. Die Eifeler Tuffsteine zeichnen sich aufgrund ihrer hohen Porosität einerseits durch eine gute Verarbeitbarkeit aus. Andererseits sind sie nur schwach gebunden und besitzen deshalb eine geringe Verwitterungsbeständigkeit.
Die Kenntnis von Materialeigenschaften spielt bei der Entwicklung oder Optimierung von Betonen und Bauweisen für den Straßenbau sowie der Qualitätssicherung eine bedeutende Rolle. Gleichermaßen bilden physikalische Materialkennwerte die Grundlage für die rechnerische Dimensionierung und die Restsubstanzbewertung von Betonfahrbahndecken. Eine relevante Kenngröße bei der Untersuchung thermisch induzierter Spannungs- und Verformungszustände stellt der thermische Ausdehnungskoeffizient dar. Im Zuge der systematischen Weiterentwicklung der rechnerischen Dimensionierung, aber auch im Zusammenhang mit der gezielten Verbesserung der Gebrauchseigenschaften von Betonfahrbahndecken gilt es zu hinterfragen, ob lastunabhängige Formänderungseigenschaften der verwendeten Betone aktuell ausreichend Beachtung finden, ob allgemeine Literaturwerte für die heutigen Fahrbandeckenbetone stets Gültigkeit besitzen und ob deren Implementierung in numerische Modelle zu realitätsnahen Vorhersagen führt. Für eine empirische Herangehensweise ist die Verfügbarkeit adäquater Prüfverfahren von entscheidender Bedeutung. In Deutschland existiert aktuell jedoch kein standardisiertes oder genormtes Verfahren für die prüftechnische Bestimmung des thermischen Ausdehnungskoeffizienten von Beton. Daher wurden unter Beachtung straßenbauspezifischer Gesichtspunkte zwei Prüfansätze entwickelt, die in diesem Beitrag vorgestellt sowie hinsichtlich möglicher Messunsicherheiten und Messungenauigkeiten diskutiert werden. Außerdem werden ausgewählte Ergebnisse aus Analysen an Bestandsbetonen aus dem BAB-Netz dargestellt. Im Ergebnis sollen die Untersuchungen einen Beitrag zur Schaffung der prüftechnischen Voraussetzungen für eine abgesicherte Quantifzierung der thermischen Dehnung von Fahrbahndeckenbetonen leisten.
In this work, which is part of a larger research program, a framework called “virtual data fusion“ was developed to provide an automated and consistent crack detection method that allows for the cross-comparison of results from large quantities of X-ray Computed Tomography (CT) data. A partial implementation of this method in a custom program was developed for use in research focused on crack quantification in Alkali-Silica Reaction (ASR)-sensitive concrete aggregates. During the CT image processing, a series of image analyses tailored for detecting specific, individual crack-like characteristics were completed. The results of these analyses were then “fused” in order to identify crack-like objects within the images with much higher accuracy than that yielded by any individual image analysis procedure. The results of this strategy demonstrated the success of the program in effectively identifying crack-like structures and quantifying characteristics, such as surface area and volume. The results demonstrated that the source of aggregate has a very significant impact on the amount of internal cracking, even when the mineralogical characteristics remain very similar. River gravels, for instance, were found to contain significantly higher levels of internal cracking than quarried stone aggregates of the same mineralogical type.
Die Oberflächentexturierung der Betonfahrbahndecken mittels Grinding- und Grooving steht seit einigen Jahren im Mittelpunkt der Forschung und Entwicklung des Betonstraßenbaus in Deutschland. In den vergangenen Jahren wurden die vorteilhaften Oberflächenperformances derartiger Texturen wie z.B. Griffigkeit, Ebenheit, Lärmminderung in zahlreichen Forschungsprojekten umfassend untersucht und daraus die Technologie „Texturgrinding“ entwickelt.
Im Kontext des gegenwärtig verfolgten ganzheitlichen performanceorientierten Ansatzes liegt der Fokus nun verstärkt auf der Analyse und Charakterisierung der Oberflächentopografie von Grinding- bzw. Groovingtexturen. Insbesondere gilt ein Hauptaugenmerk hierbei der zeitlichen Entwicklung der Oberflächentexturen in Abhängigkeit von äußeren Einwirkungen durch Klima und Verkehr.
Dieser Beitrag zeigt, dass durch den Einsatz eines auf Streifenlichtprojektion basierenden Messsystems, eine hochaufgelöste dreidimensionale Erfassung der Oberflächentopografie verschiedenartiger Grinding- und Groovingtexturen möglich ist. Darauf aufbauend wurden messtechnische Voraussetzungen zur Gewährleistung reproduzierbarer Messungen geschaffen, die eine Dokumentation der zeitlichen Texturveränderungen infolge klimatischer Beanspruchung ermöglichen. Anschließend wurden Auswerteroutinen zur quantitativen und statistischen Charakterisierung der Oberflächentextur entwickelt und angewandt, um exemplarisch die Veränderungen der Oberflächentopografie infolge klimatischer Beanspruchung quantitativ abzubilden.
The long-term exposure of marble objects leads to a successive deterioration of the rock fabric and may cause severe damage on cultural heritage objects. The magnitude of disintegration depends on the rock fabric as well as on the climatic conditions. Some types of marble show no considerable damage even if they have been exposed in northern Europe for several decades or centuries. In contrast, other marble varieties are showing severe damage after a few years of weathering. The present study shows that marble decay, along with the initial thermal degradation, is mainly influenced by the hygric and thermo-hygric load, respectively.
The influence of the rock fabric on the resistivity against weathering is also documented. The factors causing marble decay were compared to extensive climate data, which were collected during a scientific project that was started with the aim to develop a covering system for marble sculptures in Berlin. Based on the hygrothermal material properties of the marble and on the climatic conditions, the heat and moisture Transport inside the material and hence the hygrothermal load changes were calculated with a high spatial resolution. The calculations showed that the temperature and moisture fluctuations inside the material are mainly controlled by the dimensions and orientation of the sculptural elements.
The current state of preservation was investigated by two-dimensional ultrasonic tomography. The results show a good correlation to the calculated distribution of the hygrothermal load. Based on this finding, requirements on a protective winter shelter system for the sculptures were defined.
The project results show that in addition to protective covers, regular inspection and maintenance combined with regular cleaning ensures an effective and sustainable protection of marble objects in northern Europe.
Einfluss einer druckschwellinduzierten Degradation von Fahrbahndeckenbeton auf die schädigende AKR
(2020)
In den letzten Jahren sind im deutschen Bundesautobahnnetz verstärkt Schäden an vor 2005 errichteten Betonfahrbahndecken aufgetreten, die mit einer Alkali-Kieselsäure-Reaktion (AKR) in Verbindung gebracht werden. Neben dem AKR-fördernden Einfluss von alkalihaltigen Taumitteln werden Fahrbahndecken zyklischen mechanischen Belastungen infolge des Verkehrs und Zwangsspannungen durch klimatische Einwirkungen ausgesetzt. Solche mechanischen Belastungen werden bisher in keinem AKR-Prüfverfahren berücksichtigt. Die zyklischen Belastungen können zu einer Degradation des Betongefüges führen, die ggf. einen AKR-fördernden Einfluss hat. Dieser Beitrag stellt Untersuchungen vor, die zur Beantwortung der Frage nach dem Einfluss einer zyklischen mechanischen Belastung auf den AKR-Schadensprozess beitragen. Dabei wird der Hypothese nachgegangen, dass die ermüdungsinduzierte Degradation zu einer Erhöhung des Stofftransports führt.
Dieser hat einen Einfluss auf die AKR-Schadensentwicklung, da die Reaktionspartner zunächst zum Reaktionsort transportiert werden müssen. Daher wird angenommen, dass sich mit dem Stofftransport auch die AKR-Schädigung verstärkt. Es werden Betonproben aus typischen Fahrbahndeckenbetonen einer vorgeschalteten zyklischen Druckschwellbelastung ausgesetzt.
Die Degradation infolge der Vorbelastung wird simultan mittels ZfP-Verfahren charakterisiert. Anschließend werden die Auswirkungen der zyklischen Vorschädigung auf den Stofftransport sowie auf die AKR vergleichend an Prüfkörpern ohne und mit Vorschädigung untersucht. Die Ergebnisse lassen den Schluss zu, dass die zyklische Vorschädigung sowohl den Stofftransport als auch die AKR fördert.
Although concrete itself is not a combustible material, concrete mixtures with high density, such has high-performance concretes (HPCs), are susceptible to significant damage during fires due to explosive spalling. Past research has shown that the inclusion ofpolymer fibres in high density concrete can significantly mitigate this fire damage. The exact mechanisms causing this increased spalling resistance are not yet fully understood, but it is thought that the fibres facilitate moisture transport during fire exposure, which in turn contributes to relief of internal stresses in the spalling-susceptible region. In this study, X-ray Computed Tomography (CT) was applied to observe the interaction between polymer fibres and cracking during thermal exposure. For this purpose, two concrete samples containing different polymer fibre types were subjected to incremental application of a defined thermal exposure. CT images were acquired before and after each thermal exposure and powerful image processing tools were used to segment the various material components. This enabled a detailed analysis of crack formation and propagation as well as the visualization and quantification of polymer fibre characteristics within the concrete. The results demonstrated that the orientation of both fibres and cracks in polymerfibre reinforced concrete tend to be anisotropic. The results also indicated that crack geometry characteristics may be correlated with fibre orientation, with cracks tending to run parallel to fibre beds. Clear quantitative relationships were also observed between heating and increasing cracking levels, expressed in terms of both crack surface area and crack volume.
AKR an Betonfahrbahndecken - ausgewählte Einflussgrößen und neuartige AKR-Vermeidungsstrategie
(2019)
In den letzten Jahren sind im deutschen Bundesautobahnnetz vermehrt Schäden an vor 2005 hergestellten Betonfahrbahndecken aufgetreten, die mit einer Alkali-Kieselsäure-Reaktion(AKR) in Verbindung gebracht werden. Vor diesem Hintergrund werden in diesem Beitrag zunächst die Voraussetzungen und ausgewählte Einflussgrößen für eine schädigende AKR aufgezeigt.
Besondere Aufmerksamkeit wird dabei der Rolle des Tausalzeintrags durch den Winterdienst bei Betonfahrbahndecken geschenkt. So wird mit Löseversuchen in 1 M KOH-Lösung zweier Gesteinskörnungen bei 80 °C gezeigt, dass mit zunehmender NaCI-Zugabe die Löslichkeit von SiÖ2 zunimmt und die von AI2O3 eine Verminderung erfährt. Basierend auf dem so exemplarisch erbrachten Nachweis für die Verstärkung der schädigenden AKR durch das Tausalz wird die Notwendigkeit und Richtigkeit der Durchführung von AKR-Betonversuchen mit Alkalizufuhr im ARS 04/2013 zur zukünftigen Vermeidung von AKR-Schäden an Betonfahrbahndecken im Rahmen von Neubau- und Erneuerungsmaßnahmen im Bundesfernstraßennetz belegt. Zusätzlich durchgeführte WS-Grundprüfungen nach dem ARS 04/2013 mit den beiden Gesteinskörnungen der Löse versuche veranschaulichen, dass die nach der Alkali-Richtlinie des DAfStb als unbedenklich eingestuften Gesteinskörnungen bei den Betonversuchen mit Alkalizufuhr durchaus als alkaliempfindlich bewertet werden können. Dies wiederum führt zu einer Verminderung der für den Betonstraßenbau verfügbaren Gesteinskörnungen.
Vor diesem Hintergrund wird nach neuartigen AKR-Vermeidungsstrategien gesucht, die auch eine Verwendung der als grenzwertig alkaliempfindlich eingestuften Gesteinskörnungen erlaubt.
Einen möglichen Lösungsansatz stellt in diesem Kontext die Innenhydrophobierung des Fahrbahndeckenbetons dar. Es soll so durch die Behinderung des Feuchte- und Tausalzeintrags in den Beton der AKR-Schädigungsprozess signifikant vermindert werden. Für die Bewertung der Leistungsfähigkeit der Innenhydrophobierung zur Vermeidung bzw. Verminderung einer schädigenden AKR in Betonfahrbahndecken wird zurzeit im Aufträge der BASt an der BAM ein Forschungsvorhaben bearbeitet. Im Rahmen dieses Beitrags werden erste Ergebnisse dieses Projekts vorgestellt. So wird exemplarisch an einem Oberbeton (D > 8)/Unterbeton und einem Oberbeton 0/8 mit einer alkaliempfindlichen Gesteinskörnung der Einfluss zweier Hydrophobierungsmittel auf die Frisch- und Festbetoneigenschaften ganzheitlich aufgezeigt und bewertet. Bei Letzteren stehen zunächst die mechanischen und hygrischen Parameter sowie der Frost-Tausalzwiderstand im Vordergrund. In einem weiteren Schritt wird der Einfluss beider Hydrophobierungsmittel auf die schädigende AKR mittels AKR-Betonversuchen mit Alkalizufuhr beleuchtet. Dabei gelangen ergänzend zur Beurteilung des Tausalzeintrags die Laser-Induced Breakdown Spectroscopy (LIBS) und zur Bewertung der Ausprägung der AKR und sekundären Ettringitbildung (SEB) die Dünnschliffmikroskopie zum Einsatz.
Explosive spalling is caused by, among others, the thermohydraulic spalling mechanism. During this process, vaporization, dehydration, moisture-transport and condensation processes interact. As a result, a drying and dehydration zone as well as a saturated zone, known as a moisture clog, are observed inside the unilaterally-heated concrete. The presented research is focused on the experimental investigation of the underlying thermohydraulic processes.
To investigate these, a test methodology based on X-ray computed tomography (CT) and nuclear magnetic resonance (NMR) was developed. Thereby, the X-ray CT scans are carried out simultaneously during the application of a defined unilateral-heating regime on a specially-constructed specimen. This miniaturized specimen, equipped with a double-layer casing, reproduces the condition within a planar, unilaterally-heated building component.
A preliminary test methodology and the first experimental results were presented at the 5th International Workshop on Concrete Spalling in Borås, Sweden (2017). The contribution for the upcoming workshop presents an improved version of this test methodology and new results for a high-performance concrete (HPC) mixture exposed to temperatures up to 500 °C. Regarding the CT measurements, a higher time-resolution of 15 min was achieved and a quantification of the moisture changes was implemented. Due to an increase in signal quality of the NMR measurements, a pore-size specific moisture distribution can now be resolved. This allows to conclude about the moisture reconfiguration between small gel pores and larger interhydrate pores. Additionally, the NMR measurement are no longer limited to first 2.5 cm below the heated surface but a one-dimensional moisture distribution can now be estimated over the whole 10 cm long specimen.
The presented results demonstrate that the combination of X-ray CT and NMR measurements enables to image and quantify the thermally-induced moisture transport and reconfiguration from small gel pores up to macro pores. This provides important insights into the thermohydraulic damage mechanism and leads to a better understanding of spalling avoidance strategies, like the addition of polypropylene fibres.
Alkali-Kieselsäure-Reaktion in Betonfahrbahndecken unter Berücksichtigung von Verkehr und Taumitteln
(2019)
In Betonfahrbahndecken treten häufig Schäden auf, welche mit einer Alkali-Kieselsäure-Reaktion (AKR) in Verbindung gebracht werden. Obwohl die Hintergründe einer solchen AKR intensiv untersucht wurden, gibt es bei Betonfahrbahndecken besondere Randbedingungen, welche die Schadreaktion signifikant erhöhen können. Diese sind vor allem die Überlagerung der mikrostrukturellen Degradation durch Verkehrsbeanspruchung mit externer Alkali-Zufuhr durch Taumittel. Bisherige Untersuchungen der AKR beschränkten sich auf die Ausgangsstoffe (Gesteinskörnung, Zement, Bewertung des Betons), wobei die besonderen Randbedingungen außer Acht gelassen wurden. Betonfahrbahndecken sind zyklischen Belastungen aus Verkehr und Witterungsbedingungen ausgesetzt.
In einem gemeinschaftlichen Forschungsprojekt wurden die verschiedenen, gegenseitig voneinander abhängigen, Einflussfaktoren auf eine schädigende AKR in Betonfahrbahndecken sowohl experimentell untersucht als auch numerisch modelliert. Auf Mikro-Ebene wurden die AKR-bezogenen Transportprozesse innerhalb der Gesteinskörnung, sowie die Gelbildung und der Ionen-Transport, untersucht. Auf Meso-Ebene fokussierte das Projekt auf die Charakterisierung der durch zyklische Belastung induzierten Schädigung im Mikrogefüge des Betons. Des Weiteren wurde das Transportverhalten in ein derart geschädigtes Betongefüge mit und ohne Berücksichtigung des zusätzlichen Einflusses überrollender Reifen beschrieben und dessen Auswirkung auf eine AKR analysiert. Schließlich wurde auf Makro-Ebene das Risiko eines AKR-bedingten Schadens bewertet. Einige ausgewählte Ergebnisse werden in diesem Beitrag dargestellt.
AKR an Betonfahrbahndecken - ausgewählte Einflussgrößen und neuartige AKR-Vermeidungsstrategie
(2019)
In den letzten Jahren sind im deutschen Bundesautobahnnetz vermehrt Schäden an vor 2005 hergestellten Betonfahrbahndecken aufgetreten, die mit einer Alkali-Kieselsäure-Reaktion (AKR) in Verbindung gebracht werden. Vor diesem Hintergrund werden in diesem Beitrag zunächst die Voraussetzungen und ausgewählte Einflussgrößen für eine schädigende AKR aufgezeigt.
Besondere Aufmerksamkeit wird dabei der Rolle des Tausalzeintrags durch den Winterdienst bei Betonfahrbahndecken geschenkt. So wird mit Löseversuchen in 1 M KOH-Lösung zweier Gesteinskörnungen bei 80 °C gezeigt, dass mit zunehmender NaCI-Zugabe die Löslichkeit von SiÖ2 zunimmt und die von AI2O3 eine Verminderung erfährt. Basierend auf dem so exemplarisch erbrachten Nachweis für die Verstärkung der schädigenden AKR durch das Tausalz wird die Notwendigkeit und Richtigkeit der Durchführung von AKR-Betonversuchen mit Alkalizufuhr im ARS 04/2013 zur zukünftigen Vermeidung von AKR-Schäden an Betonfahrbahndecken im Rahmen von Neubau- und Erneuerungsmaßnahmen im Bundesfernstraßennetz belegt. Zusätzlich durchgeführte WS-Grundprüfungen nach dem ARS 04/2013 mit den beiden Gesteinskörnungen der Löse versuche veranschaulichen, dass die nach der Alkali-
Richtlinie des DAfStb als unbedenklich eingestuften Gesteinskörnungen bei den Betonversuchen mit Alkalizufuhr durchaus als alkaliempfindlich bewertet werden können. Dies wiederum führt zu einer Verminderung der für den Betonstraßenbau verfügbaren Gesteinskörnungen.
Vor diesem Hintergrund wird nach neuartigen AKR-Vermeidungsstrategien gesucht, die auch eine Verwendung der als grenzwertig alkaliempfindlich eingestuften Gesteinskörnungen erlaubt.
Einen möglichen Lösungsansatz stellt in diesem Kontext die Innenhydrophobierung des Fahrbahndeckenbetons dar. Es soll so durch die Behinderung des Feuchte- und Tausalzeintrags in den Beton der AKR-Schädigungsprozess signifikant vermindert werden. Für die Bewertung der Leistungsfähigkeit der Innenhydrophobierung zur Vermeidung bzw. Verminderung einer schädigenden AKR in Betonfahrbahndecken wird zurzeit im Aufträge der BASt an der BAM ein Forschungsvorhaben bearbeitet. Im Rahmen dieses Beitrags werden erste Ergebnisse dieses Projekts vorgestellt. So wird exemplarisch an einem Oberbeton (D > 8)/Unterbeton und einem Oberbeton 0/8 mit einer alkaliempfindlichen Gesteinskörnung der Einfluss zweier Hydrophobierungsmittel auf die Frisch- und Festbetoneigenschaften ganzheitlich aufgezeigt und bewertet. Bei Letzteren stehen zunächst die mechanischen und hygrischen Parameter sowie der Frost-Tausalzwiderstand im Vordergrund. In einem weiteren Schritt wird der Einfluss beider Hydrophobierungsmittel auf die schädigende AKR mittels AKR-Betonversuchen mit Alkalizufuhr beleuchtet. Dabei gelangen ergänzend zur Beurteilung des Tausalzeintrags die Laser-Induced Breakdown Spectroscopy (LIBS) und zur Bewertung der Ausprägung der AKR und sekundären Ettringitbildung (SEB) die Dünnschliffmikroskopie zum Einsatz.
Thermally-induced moisture transport in high-performance concrete studied by X-ray-CT and 1H-NMR
(2019)
The thermohydraulic damage mechanism is one of the primary causes for explosive spalling of highperformance concrete. This paper presents the spatially- and temporally-resolved analysis of the thermally-induced moisture transport and reconfiguration processes by means of X-ray-CT and 1HNMR.
Thermal testing results for a high-performance concrete, which is sensitive to explosive spalling and which was prepared with and without added polypropylene fibres, are presented in this paper. These results indicate that the addition of fibres leads to a faster and deeper migration of the drying front and, thus, to a lower likelihood of vapour-pressure induced explosive spalling.
AKR an Betonfahrbahndecken – ausgewählte Einflussgrößen und neuartige AKR-Vermeidungsstrategie
(2019)
In den letzten Jahren sind im deutschen Bundesautobahnnetz vermehrt Schäden an vor 2005 hergestellten Betonfahrbahndecken aufgetreten, die mit einer Alkali-Kieselsäure-Reaktion (AKR) in Verbindung gebracht werden. Vor diesem Hintergrund werden in diesem Beitrag zunächst die Voraussetzungen und ausgewählte Einflussgrößen für eine schädigende AKR aufgezeigt. Besondere Aufmerksamkeit wird dabei der Rolle des Tausalzeintrags durch den Winterdienst bei Betonfahrbahndecken geschenkt. So wird mit Löseversuchen in 1 M KOH-Lösung zweier Gesteinskörnungen bei 80 °C gezeigt, dass mit zunehmender NaCl-Zugabe die Löslichkeit von SiO2 zunimmt und die von Al2O3 eine Verminderung erfährt. Basierend auf dem so exemplarisch erbrachten Nachweis für die Verstärkung der schädigenden AKR durch das Tausalz wird die Notwendigkeit und Richtigkeit der Durchführung von AKR-Betonversuchen mit Alkalizufuhr im ARS 04/2013 zur zukünftigen Vermeidung von AKR-Schäden an Betonfahrbahndecken im Rahmen von Neubau- und Erneuerungsmaßnahmen im Bundesfernstraßennetz belegt. Zusätzlich durchgeführte WS-Grundprüfungen nach dem ARS 04/2013 mit den beiden Gesteinskörnungen der Löseversuche veranschaulichen, dass die nach der Alkali-Richtlinie des DAfStb als unbedenklich eingestuften Gesteinskörnungen bei den Betonversuchen mit Alkalizufuhr durchaus als alkaliempfindlich bewertet werden können. Dies wiederum führt zu einer Verminderung der für den Betonstraßenbau verfügba-ren Gesteinskörnungen. Vor diesem Hintergrund wird nach neuartigen AKR-Vermeidungsstrategien gesucht, die auch eine Verwendung der als grenzwertig alkaliemp-findlich eingestuften Gesteinskörnungen erlaubt. Einen möglichen Lösungsansatz stellt in diesem Kontext die Innenhydrophobierung des Fahrbahndeckenbetons dar. Es soll so durch die Behinderung des Feuchte- und Tausalzeintrags in den Beton der AKR-Schädigungsprozess signifikant vermindert werden. Für die Bewertung der Leistungsfähigkeit der Innenhydrophobierung zur Vermeidung bzw. Verminderung einer schädigenden AKR in Betonfahrbahndecken wird zurzeit im Auftrage der BASt an der BAM ein Forschungsvorha-ben bearbeitet. Im Rahmen dieses Beitrags werden erste Ergebnisse dieses Projekts vorge-stellt. So wird exemplarisch an einem Oberbeton (D > 8)/Unterbeton und einem Oberbeton 0/8 mit einer alkaliempfindlichen Gesteinskörnung der Einfluss zweier Hydrophobierungsmit-tel auf die Frisch- und Festbetoneigenschaften ganzheitlich aufgezeigt und bewertet. Bei Letz-teren stehen zunächst die mechanischen und hygrischen Parameter sowie der Frost-Tausalzwiderstand im Vordergrund. In einem weiteren Schritt wird der Einfluss beider Hydro-phobierungsmittel auf die schädigende AKR mittels AKR-Betonversuchen mit Alkalizufuhr beleuchtet. Dabei gelangen ergänzend zur Beurteilung des Tausalzeintrags die Laser-Induced Breakdown Spectroscopy (LIBS) und zur Bewertung der Ausprägung der AKR und sekundä-ren Ettringitbildung (SEB) die Dünnschliffmikroskopie zum Einsatz.
Verstärkt auftretende Schäden in Betonfahrbahndecken des Bundesfernstraßennetzes, die mit einer Alkali-Kieselsäure-Reaktion (AKR) in Verbindung gebracht werden, haben zu einer massiven Verschärfung der Prüfvorschriften zur Bewertung der Alkaliempfindlichkeit von Ge-steinskörnungen geführt. Die damit verbundene Einschränkung potenziell für den Straßenbau einsetzbarer Gesteinskörnungen ruft eine verstärkte Ressourcenknappheit und ein erhöhtes Transport- und damit einhergehendes Kostenaufkommen hervor. Vor diesem Hintergrund wird nach neuartigen AKR-Vermeidungsstrategien gesucht, die auch eine Verwendung grenzwertig alkaliempfindlich eingestufter Gesteinskörnungen erlaubt. Einen möglichen Lösungsansatz stellt in diesem Kontext die Innenhydrophobierung des Fahrbahndeckenbetons dar. Es soll so durch die Behinderung des Feuchte- und Tausalzeintrags in den Beton der AKR-Schädigungs-prozess signifikant vermindert werden. Für die Bewertung der Leistungsfähigkeit der Innen-hydrophobierung zur Vermeidung einer schädigenden AKR in Betonfahrbahndecken wird zur-zeit im Auftrage der BASt an der BAM ein Forschungsvorhaben bearbeitet. Im Rahmen dieses Beitrags werden erste ausgewählte Ergebnisse dieses Forschungsvorhabens vorgestellt. So wird exemplarisch an einem Oberbeton (0/8) mit einer alkaliempfindlichen Gesteinskörnung der Einfluss eines Hydrophobierungsmittels auf die Frisch- und Festbetoneigenschaften ganz-heitlich aufgezeigt und bewertet. Bei Letzteren stehen zunächst die mechanischen und hygri-schen Parameter sowie der Frost-Tausalzwiderstand im Vordergrund. In einem weiteren Schritt wird der Einfluss der Innenhydrophobierung auf die schädigende AKR mittels verschie-denartiger AKR-Performanceprüfungen beleuchtet.
Verstärkt auftretende Schäden in Betonfahrbahndecken des Bundesfernstraßennetzes, die mit einer Alkali-Kieselsäure-Reaktion (AKR) in Verbindung gebracht werden, haben zu einer massiven Verschärfung der Prüfvorschriften zur Bewertung der Alkaliempfindlichkeit von Ge-steinskörnungen geführt. Die damit verbundene Einschränkung potenziell für den Straßenbau einsetzbarer Gesteinskörnungen ruft eine verstärkte Ressourcenknappheit und ein erhöhtes Transport- und damit einhergehendes Kostenaufkommen hervor. Vor diesem Hintergrund wird nach neuartigen AKR-Vermeidungsstrategien gesucht, die auch eine Verwendung grenzwertig alkaliempfindlich eingestufter Gesteinskörnungen erlaubt. Einen möglichen Lösungsansatz stellt in diesem Kontext die Innenhydrophobierung des Fahrbahndeckenbetons dar. Es soll so durch die Behinderung des Feuchte- und Tausalzeintrags in den Beton der AKR-Schädigungs-prozess signifikant vermindert werden. Für die Bewertung der Leistungsfähigkeit der Innen-hydrophobierung zur Vermeidung einer schädigenden AKR in Betonfahrbahndecken wird zur-zeit im Auftrage der BASt an der BAM ein Forschungsvorhaben bearbeitet. Im Rahmen dieses Beitrags werden erste ausgewählte Ergebnisse dieses Forschungsvorhabens vorgestellt. So wird exemplarisch an einem Oberbeton (0/8) mit einer alkaliempfindlichen Gesteinskörnung der Einfluss eines Hydrophobierungsmittels auf die Frisch- und Festbetoneigenschaften ganzheitlich aufgezeigt und bewertet. Bei Letzteren stehen zunächst die mechanischen und hygrischen Parameter sowie der Frost-Tausalzwiderstand im Vordergrund. In einem weiteren Schritt wird der Einfluss der Innenhydrophobierung auf die schädigende AKR mittels verschiedenartiger AKR-Performanceprüfungen beleuchtet.
Water migration in one-side heated concrete: 4D in-situ CT monitoring of the moisture-clog-effect
(2019)
Explosive spalling due to fire exposure in concrete structures can lead severe damage and, in the worst case, to premature component failure. For this reason, an in situ investigation of water Migration in concrete due to surface heating was undertaken.
During these experiments, a miniaturized concrete specimen within a confining and insulating double-hull was subjected to surface heating during simultaneous X-ray computed tomography (CT) scanning. Through the use of subtraction-based Image analysis techniques, it was possible to observe and quantify not only drying within areas of the concrete matrix close to the heated surface, but also the migration of moisture to both pore and matrix regions deeper within the specimen. It was also discovered that the correction of CT images for specimen deformation using DVC and variable detector performance using calibrated image filters significantly improved the quality of the results. This clearly demonstrates the potential of X-ray CT for evaluation of other rapid-density-change phenomena in concrete and other building materials.
Although concrete itself is not a combustible material, concrete mixtures with high density, such has high-performance concretes (HPCs), are susceptible to significant damage during fires due to explosive spalling. Past research has shown that the inclusion of polymer fibres in high density concrete can significantly mitigate this fire damage. The exact mechanisms causing this increased spalling resistance are not yet fully under-stood, but it is thought that the fibres facilitate moisture transport during fire exposure, which in turn contributes to relief of internal stresses in the spalling-susceptible region. In this study, X-ray Computed Tomography (CT) was applied to observe the interaction between polymer fibres and cracking during thermal exposure. For this purpose, two concrete samples containing different polymer fibre types were subjected to incremental application of a defined thermal exposure. CT images were acquired before and after each thermal exposure and powerful image processing tools were used to segment the various material components. This enabled a detailed analysis of crack formation and propagation as well as the visualization and quantification of polymer fibre characteristics within the concrete. The results demonstrated that the orientation of both fibres and cracks in polymer-fibre reinforced concrete tend to be anisotropic. The results also indicated that crack geometry characteristics may be correlated with fibre orientation, with cracks tending to run parallel to fibre beds. Clear quantitative relationships were also observed between heating and increasing cracking levels, expressed in terms of both crack surface area and crack volume.
This paper describes a novel methodology for quantitative in-situ moisture measurement without tracking agents using X-ray computed tomography (XCT). The high levels of grey-scale precision required for the measurement of moisture without tracking agents resulted in the need for an additional image calibration procedure to correct for water-related X-ray scattering and for equipment-variability related artefacts arising during in-situ testing. This calibration procedure was developed on the basis of existing principles of XCT image cor-rection. Resulting images of moisture distribution exhibit a high level of agreement with expected material behaviour. This research demonstrated that XCT can be successfully used to measure both moisture-front movement over time and changes in 3D moisture distribution within samples. This approach to moisture measurement lays the groundwork for the planned future investigation of the interaction between cracking induced by varying chemical and mechanical processes and water transport in concrete.
Analyse des Tausalzeintrages in Fahrbahndeckenbetone im Kontext der Alkali-Kieselsäure-Reaktion
(2018)
In den letzten Jahren sind im deutschen Bundesautobahnnetz (BAB-Netz) vermehrt AKR-Schäden an Betonfahrbahndecken aufgetreten, die zum Teil zu einer Halbierung ihrer geplanten Nutzungsdauer von 30 Jahren führte. Ursächlich hierfür ist die Verwendung alkaliempfindlicher Gesteinskörnung, die bei gleichzeitiger Anwesenheit von Wasser infolge der Exposition der Fahrbahndecke und dem alkalischen Milieu durch den Einsatz alkalireicher Portlandzemente bei der Betonherstellung zu einer Alkali-Kieselsäure-Reaktion (AKR) führt. Zusätzlich wird der AKR-Schädigungsprozess in Betonfahrbahndecken durch den externen Tausalzeintrag (primär NaCl) im Winter begünstigt. Vor diesem Hintergrund kommt der Ermittlung des Tausalzeintrags in den Fahrbahndeckenbeton eine große Bedeutung zu. Die Analyse des Tausalzeintrags erfolgte bisher ausschließlich nasschemisch an gemahlenen Bohrkernsegmenten. Nachteilig ist hierbei die fehlende differenzierte Betrachtung des Natriumgehaltes im Zementstein und in der Gesteinskörnung. Der alternative Einsatz von LIBS (Laser-induced breakdown spectroscopy) eröffnet in diesem Kontext neue Möglichkeiten. So wird in diesem Beitrag an Hand von Bohrkernen aus einem AKR-geschädigten BAB-Abschnitt exemplarisch die Vorgehensweise bei der LIBS-Analyse zur Ermittlung der Na- und interagierenden Cl-Verteilung an vertikalen Schnittflächen des Bohrkerns aufgezeigt. Da der Tausalzeintrag primär über den Zementstein erfolgt, wurde der verfälschende Na-Grundgehalt der Gesteinskörnung mittels Zementsteinkriteriums (Nutzung unterschiedlichen Ca-Gehalts in Zementstein und Gesteinskörnung) eliminiert. Vergleichend durchgeführte Cl-Mappings mit Mikroröntgenfluoreszenzanalyse (MRFA) belegen die Güte der durchgeführten LIBS-Messungen.
Aber auch bei der Verifizierung der Übertragbarkeit der Ergebnisse der zum Ausschluss reaktiver Gesteinskörnung bei Neubau und Erneuerung im BAB-Netz eingesetzten Performanceprüfungen mit externem Alkalieintrag auf Praxisverhältnisse hat sich das LIBSVerfahren bewährt. So wurde festgestellt, dass die mit NaCl-Lösung beaufschlagten Laborprüfkörper aus einem repräsentativen Fahrbahndeckenbeton bei der Klimawechsellagerung (KWL) über ihre gesamte Höhe von 10 cm einen Eintrag von Na und Cl erfahren. Weiterhin konnte im Gegensatz zu bisherigen Annahmen erstmals mit LIBS und Nasschemie gezeigt werden, dass die Frost-Tauwechsel-Phase bei der KWL zu keinem erhöhten Tausalzeintrag führt.
In concrete pavements, damages occurred which are related to an Alkali-Silica-Reaction (ASR). Although the background for such an ASR has been studied extensively, special conditions in pavements increase this reaction significantly. These are especially the superposition of microstructural degradation caused by cyclic loading with an external alkali supply. Previous investigations of ASR focused mainly on the material itself (aggregates, cements, assessment of the concrete) while these special circumstances have not been considered. Concrete pavements are subjected to cyclic loadings by traffic and climate changes.
Within cooperative research projects the different interdependent influencing factors for a damaging ASR in concrete pavements are studied by experiments as well as by numeric modelling. On the micro-level the ASR-related processes within the aggregate, such as gel-formation or ion-transport, are investigated. On the meso-level, the project focuses on the characterization of degradation effects in the concrete microstructure due to cyclic loading. Further, special attention is paid to the transport behavior of fluids in such pre-damaged concrete structures with and without the effect of overrunning tires as well as the impact on the ASR itself. Finally, on the macro-level the risk of an ASR-damage is assessed.
In den letzten Jahren sind im deutschen Bundesautobahnnetz vermehrt AKR-Schäden an Betonfahrbahndecken aufgetreten. Ursächlich hierfür ist die Verwendung alkaliempfindlicher Gesteinskörnung. Dies führt bei gleichzeitiger Anwesenheit von Wasser infolge der Exposition der Fahrbahndecke und des alkalischen Milieus durch den Einsatz alkalireicher Portlandzemente bei der Betonherstellung zu einer Alkali-Kieselsäure-Reaktion (AKR). Zusätzlich wird der AKR-Schädigungsprozess in Betonfahrbahndecken durch den externen Tausalzeintrag (primär NaCl) im Winter begünstigt. Vor diesem Hintergrund kommt der Ermittlung des Tausalzeintrags in den Fahrbahndeckenbeton eine große Bedeutung zu.
Die Analyse des Tausalzeintrags erfolgte bisher ausschließlich nasschemisch an gemahlenen Bohrkernsegmenten. Nachteilig sind hierbei der relativ hohe prüftechnische Aufwand und die eingeschränkte Ortsauflösung. Der alternative Einsatz von LIBS (Laser-induced breakdown spectroscopy) eröffnet in diesem Kontext neue Möglichkeiten. So wird in diesem Beitrag anhand von Bohrkernen aus einem repräsentativen AKR-geschädigten BAB-Abschnitt exemplarisch die Vorgehensweise bei der LIBS-Analyse zur Ermittlung der Na- und Cl-Verteilung an vertikalen Schnittflächen von Bohrkernen aufgezeigt. Da der Tausalzeintrag primär über den Zementstein erfolgt, wurde der verfälschende Na-Grundgehalt der Gesteinskörnung mittels eines Ausschlusskriteriums (Ca-Gehalt) eliminiert. Vergleichend durchgeführte Cl-Mappings mit Mikroröntgenfluoreszenzanalyse sowie nasschemische Analysen belegen die Güte der durchgeführten LIBS-Messungen. Allerdings bedarf es bei der quantitativen Ermittlung des Natriumgehaltes in der Betonfahrbahndecke noch weitergehender Untersuchungen.
Dunkelfärbung der Betonfahrbahndecke im AKR-Kontext - Ursachenanalyse mit innovativer Prüftechnik
(2018)
Die AKR-Schadensevolution von Betonfahrbahndecken ist in der Anfangsphase durch eine Dunkelfärbung der Oberfläche im Fugenbereich gekennzeichnet. Es wird vermutet, dass eine erhöhte Durchfeuchtung der Betonrandzone ursächlich für diese Erscheinung ist. Vor diesem Hintergrund wurde exemplarisch eine Fahrbahnplatte eines repräsentativen Bundesautobahnabschnitts systematisch mit verschiedenartiger zerstörungsfreier Prüftechnik vor Ort untersucht. Die Ergebnisse der zunächst erfolgten großflächigen Durchmusterung mit Radar zeigen, dass in den Bereichen mit einer Dunkelfärbung der Betonfahrbahndecke erhöhte Laufzeiten der Radarimpulse zwischen der
Oberfläche und der Rückseite der Betonfahrbahndecke auftreten, was auf eine erhöhte integrale Durchfeuchtung der Betonfahrbahndecke schließen lässt. Vertiefend durchgeführte NMR-Feuchtemessungen in der Betonrandzone zeigen eine gute Korrelation zwischen erhöhtem Feuchtegehalt und der dunkel gefärbten Fahrbahnoberfläche. Die Ergebnisse beider zerstörungsfreien Prüfmethoden lassen den Schluss zu, dass die Betonfahrbahndecke in der Nähe des Fugenkreuzes eine höhere Durchfeuchtung als im Bereich der Querscheinfuge aufweist. Die geringste Durchfeuchtung besitzt die Betonfahrbahndecke in der Plattenmitte. Die mit den zerstörungsfreien Prüfverfahren ermittelten Befunde stimmen prinzipiell gut mit den punktuell mittels Darr-Wäge-Verfahren an Bohrmehlproben gewonnenen Ergebnissen überein.
Die vorstehend dargestellten Untersuchungen lassen sich wie folgt zusammenfassen:
• Mit dem für die mechanische Vorschädigung entwickelten Versuchsstand und gewählten Prüfregime können die für die ermüdungsinduzierte Schadensevolution typische stabilisierende und stabile Phase in der auf Zug beanspruchten Betonrandzone gut abgebildet werden. So wurde dort zum Beispiel, ausgehend von dem hier gewählten praxisnahen Belastungsregime, mit Ultraschall in der Ruhephase durch das Trockenschwingen ein maximaler Abfall des relativen dynamischen E-Moduls von ca. 8 - 10 % ermittelt.
• Mit aufbauenden kapillaren Aufsaugversuchen wurde gezeigt, dass die erzeugte Betondegradation zu einer moderaten Erhöhung der Aufnahme des Prüfmediums führt.
• Zur Bewertung der Auswirkungen einer alleinigen Vorschädigung (Trockenschwingen) auf die schädigende AKR mittels Performance-Prüfung ist die Klimawechsellagerung aufgrund der einseitigen Tausalzbeaufschlagung am besten geeignet. Die hier ermittelten Dehnungsverläufe lassen auf einen moderaten Einfluss der mechanischen Vorschädigung auf die AKR schließen.
• Die zusätzlich im Kontext der Nasschwingversuche durchgeführten 60°C Betonversuche zeigen, dass die zyklische Beanspruchung vor und nach dem Aufbringen der Tausalzlösung die schädigende AKR gleichfalls moderat erhöht.
In derzeit laufenden ergänzenden Untersuchungen wird der separate Einfluss der ermüdungsinduzierten Rissbildung auf die schädigende AKR an homogen, stärker geschädigten Prüfkörpern mit einem hohen inneren AKR-Schädigungspotenzial im 60°C Betonversuch grundhaft analysiert. Zusätzlich wird gegenwärtig der Einfluss der degradierten Betonrandzone auf die Dehnungsverteilung an großformatigen Prüfkörpern
über die Höhe im 40°C Betonversuch vertiefend für die makroskopische Modellierung untersucht.
Fatigue induced degradation in pavement concrete and its effect on the alkali-silica reaction
(2018)
In recent years the German motorway network has seen an increase in the occurrence of damage to concrete road surfaces that can be attributed to the alkali-silica reaction (ASR). In view of the often drastically reduced service life of road surfaces due to ASR, research activity in this field has notably increased. Alongside preventative measures in concrete technology i.e. the usage of low-alkali cements, the main research focus up to now has been on the development of performance-oriented testing procedures for ASR prevention. The effects of mechanicallyinduced damage resulting from cyclic traffic and climatic loading have previously not been taken into consideration.
The assessment of the myriad degradation and transport processes necessary for an understanding of these effects requires close interaction between experiments and corresponding multi-scale models. This contribution is focused on the experiments utilizing innovative testing techniques. The research is founded on a series of fatigue tests performed on large-scale beams with simultaneous tracking of the degradation process using non-destructive evaluation methods. Subsequently, smaller test specimens were extracted from the predamaged beams for further experiments. These experiments included investigation of the influence of fatigue-induced cracks on moisture and alkali transport. Subsequent storage of the small-scale test specimens, with and without cyclic pre-damage, in an ASR-conducive environment then provided initial findings on the influence of fatigue-induced degradation on the ASR.
The results show that the degradation process can be well observed with the test Setup developed for the fatigue experiments. Further, a small but noticeable increase of mass Transport due to fatigue-induced degradation was measured, which correspondingly indicated an increased ASR damage potential.
Die vorstehend dargestellten Untersuchungen lassen sich wie folgt zusammenfassen:
• Mit dem für die mechanische Vorschädigung entwickelten Versuchsstand und
gewählten Prüfregime können die für die ermüdungsinduzierte Schadensevolution
typische stabilisierende und stabile Phase in der auf Zug beanspruchten
Betonrandzone gut abgebildet werden. So wurde dort zum Beispiel, ausgehend
von dem hier gewählten praxisnahen Belastungsregime, mit Ultraschall in der
Ruhephase durch das Trockenschwingen ein maximaler Abfall des relativen
dynamischen E-Moduls von ca. 8 - 10 % ermittelt.
• Mit aufbauenden kapillaren Aufsaugversuchen wurde gezeigt, dass die erzeugte
Betondegradation zu einer moderaten Erhöhung der Aufnahme des Prüfmediums
führt.
• Zur Bewertung der Auswirkungen einer alleinigen Vorschädigung (Trockenschwingen)
auf die schädigende AKR mittels Performance-Prüfung ist die Klimawechsellagerung
aufgrund der einseitigen Tausalzbeaufschlagung am besten
geeignet. Die hier ermittelten Dehnungsverläufe lassen auf einen moderaten
Einfluss der mechanischen Vorschädigung auf die AKR schließen.
• Die zusätzlich im Kontext der Nasschwingversuche durchgeführten 60°C Betonversuche
zeigen, dass die zyklische Beanspruchung vor und nach dem Aufbringen
der Tausalzlösung die schädigende AKR gleichfalls moderat erhöht.
In derzeit laufenden ergänzenden Untersuchungen wird der separate Einfluss der ermüdungsinduzierten
Rissbildung auf die schädigende AKR an homogen, stärker geschädigten
Prüfkörpern mit einem hohen inneren AKR-Schädigungspotenzial im 60°C
Betonversuch grundhaft analysiert. Zusätzlich wird gegenwärtig der Einfluss der degradierten
Betonrandzone auf die Dehnungsverteilung an großformatigen Prüfkörpern
über die Höhe im 40°C Betonversuch vertiefend für die makroskopische Modellierung
untersucht.
Im deutschen Bundesautobahnnetz treten vor allem an den vor 2005 errichteten Betonfahrbahndecken vermehrt Schäden auf, die mit einer AKR in Verbindung gebracht werden. Sie äußern sich zunächst in einer Dunkelfärbung in den Fugenbereichen der Betonfahrbahndecke. Oft wird diese Erscheinung von einer von der Fuge ausgehenden horizontalen Rissbildung parallel zur Fahrbahnoberfläche begleitet. Durch den Einsatz der NMR-Technik konnte erstmals zerstörungsfrei der erhöhte Feuchtegehalt in der Betonrandzone als Ursache für diese Erscheinung nachgewiesen werden. Zusätzlich durchgeführte Radaruntersuchungen und Darr-Wäge-Versuche zeigten, dass die erhöhte Durchfeuchtung in der Betonrandzone in der Regel den gesamten Fahrbahnquerschnitt erfasst. Weiterhin wurde aufgezeigt, dass vor allem die akustischen Verfahren eine zerstörungsfreie Detektion der von der Fuge ausgehenden lateralen Ausdehnung der oberen Rissebene in die Fahrbahnplatte ermöglichen. Im Gegensatz zum Impakt-Echo-Verfahren erlaubt das Ultraschall-Echo-Verfahren zusätzlich die Ermittlung der Tiefenlage der oberen Rissebene. Es wird eine weitere Ertüchtigung der akustischen Verfahren für die Strukturaufklärung in Betonfahrbahndecken angeregt.
Ermüdungsbedingte Degradation und ihre Auswirkungen auf den Stofftransport in Fahrbahndeckenbeton
(2017)
Im Rahmen des Beitrags soll aufgezeigt werden, welchen Einfluss eine mechanisch induzierte Vorschädigung (Ermüdungsbeanspruchung) auf den Ablauf und die Intensität des AKR-Schädigungsprozesses hat. Dies erfordert eine ausführliche Beschreibung der vielfältigen interagierenden Schädigungs- und Transportprozesse und aufbauend eine enge Verknüpfung von Experimenten mit einer mehrskaligen Modellierung.
Die experimentelle Basis bildete die mechanische Vorschädigung (Ermüdungsbeansprochung) großformatiger Balken aus einem Fahrbahndeckenbeton bei Einsatz alkaliempfindlicher Gesteinskörnungen. Aus diesen großformatigen Balken wurden nach erfolgter Ermüdungsbeanspruchung kleinformatige Probekörper gewonnen. An diesen wurde detailliert untersucht wie sich die mechanische Vorschädigung auf das Betongefüge und die daraus resultierenden Transport- und Schädigungsprozesse auswirkt. Von der mechanisch induzierten Vorschädigung bis zum AKR Schädigungsprozess sollten in diesem Kontext die Rissbildungsprozesse und der interagierende Eintrag bzw. die Auslaugung der Alkalien ganzheitlich betrachtet werden. Der Beitrag fokussiert auf die Charakterisierung der infolge der mechanischen Vorschädigung induzierten Rissbildungsprozesse. Ferner wird detailliert auf die Auswirkungen der mechanischen Rissbildung auf den Stofftransport eingegangen.
It is known that the spalling risk of dense, high-strength concretes (HSC) can be reduced by the addition of polypropylene (PP) fibres and, in particular, PP-fibres that have been pre-treated using electron irradiation. It is presumed that the enhanced reduction in spalling resulting from electron irradiation pre-treatment of the fibres can be attributed to enhanced penetration of the molten fibre material into the micro-cracks around the fibres, due to their significantly decreased viscosity. So far there has been no experimental evidence for this. Against this background, this paper gives a com-parative analysis of the mode of action of PP-fibres with and without pre-treatment using multi-scale test methodology.
Initially, fire tests on small-scale building components with accompanying damage monitoring veri-fied that the amount of PP-fibres can be halved by using pre-treated PP-fibres without reducing the fire performance of HSC. Detailed investigations of PP-fibres carried out in a completed research project funded by DFG (the German Research Foundation) using digital scanning calorimetry and thermogravimetry measurements (DSC/TG) as well as viscometer measurements showed that the pre-treatment has no significant influence on the melting temperature of the PP-fibres. However, a drastic reduction of the melt viscosity due to the electron irradiation was detectable. Additional dila-tation tests showed that the expansion behaviour of both fibre types and their melts do not differ significantly [1]. Rather, both fibre types generate high pressures when their thermal expansion is hindered. Further detailed investigations by means of continuous heating tests with a low heating rate were carried out on separately produced concrete cylinders. These tests showed that the pre-treatment of the PP-fibres causes earlier dehydration in conjunction with stagnation of thermal expansion of the concrete cylinders (temperature reduction from 180 °C to 170 °C). This is accompanied by in-creased acoustic emission activity during the thermal expansion tests. This leads to the assumption that the pre-treatment of PP-fibres results in earlier micro-crack development. However, it was not possible to confirm this assumption by microscopic examination of drilling cores with a diameter of 30 mm exposed to defined temperatures in the range between 150°C and 300°C. Microscopic obser-vations and additional X-ray 3D computed tomography (3D-CT) scans on miniaturised drilling cores exposed to temperature cycles showed a similar networking of fibre beds by means of micro-cracks in HSC for both fibre types. However, energy dispersive X-ray spectroscopy and wavelength disper-sive X-ray spectroscopy revealed fundamental differences in the penetration capacity of the fibre melts of the two fibre types. The increased penetration of the pre-treated PP-fibre melt revealed in these tests, confirms the initial working hypothesis.
Unilateral thermal exposure of concrete building components induces moisture transport processes that have a significant influence on the spalling behaviour of dense high-strength concrete (HSC). These transport processes are based on evaporation and condensation mechanisms of liquid and gaseous water in the pores as well as the chemically bound water within the concrete. The low permeability of HSC and the formation of a saturated zone within building components (also known as a moisture clog) leads to high water-vapour pressures, which contributes to explosive spalling. The formation of these pressures has already been verified by means of pore-pressure measurement techniques. In addition, the redistribution of the moisture within concrete specimens subject to unilateral thermal exposure has been demonstrated on fractured surfaces. Investigations by means of the nuclear magnetic resonance (NMR) relaxometry technique and neutron radiography have shown one-dimensional changes in moisture distribution during thermal exposure.
However, none of these methods has been able to depict the moisture distribution in three dimensions (3D), so the link between pore size, concrete micro-structure and moisture content is missing. The research project presented in this paper aims to fill this gap by developing a new multi-level test methodology to characterise non-destructively the temporal course of spatial moisture distribution during unilateral thermal exposure. The procedure used during this programme included the collection of X-ray 3D-computed tomography (CT) measurements using a miniaturised specimen subjected to in-situ thermal exposure and the comparison of those CT results with the results of one-dimensional NMR-relaxometry before and after the heating process.
In the first step, a mobile heating device was developed, built and tested. To simulate a unilaterally-heated construction component, a cylindrical specimen made of HSC (Ø = 40 mm, L = 100 mm) was cast into an impermeable glass ceramic shell. The ceramic shell ensured a one-dimensional moisture flux and limited the thermal expansion of the concrete. An additional high-temperature wool (HTW) insulating shell ensured a one-dimensional heat flux. The heating device, which operated using infrared radiation (IR), allowed the unilateral heating of the specimens up to 300 °C using variable heating regimes.
In the second step, the mobile heating device was integrated into the CT-scanner, which enabled the collection of measurements before, during and after heating. By subtraction of successive 3D-CT images, X-ray attenuation differences could be resolved three-dimensionally in the specimen and interpreted as changes in the moisture content.
Initial results show that this test methodology can monitor the 3D changes of moisture content inside the specimen during thermal exposure. It enables the researcher to visualise areas with moisture accumulation as well as dehydrated areas inside the specimen. Comparative one-dimensional NMR-relaxometry measurements confirm the results of the CT image analysis.
It is known that the spalling risk of dense, high-strength concretes (HSC) can be reduced by the addition of polypropylene (PP) fibres and, in particular, PP-fibres that have been pre-treated using electron irradiation. It is presumed that the enhanced reduction in spalling resulting from electron irradiation pre-treatment of the fibres can be attributed to enhanced penetration of the molten fibre material into the micro-cracks around the fibres, due to their significantly decreased viscosity. So far there has been no experimental evidence for this. Against this background, this paper gives a com-parative analysis of the mode of action of PP-fibres with and without pre-treatment using multi-scale test methodology.
Initially, fire tests on small-scale building components with accompanying damage monitoring veri-fied that the amount of PP-fibres can be halved by using pre-treated PP-fibres without reducing the fire performance of HSC. Detailed investigations of PP-fibres carried out in a completed research project funded by DFG (the German Research Foundation) using digital scanning calorimetry and thermogravimetry measurements (DSC/TG) as well as viscometer measurements showed that the pre-treatment has no significant influence on the melting temperature of the PP-fibres. However, a drastic reduction of the melt viscosity due to the electron irradiation was detectable. Additional dila-tation tests showed that the expansion behaviour of both fibre types and their melts do not differ significantly [1]. Rather, both fibre types generate high pressures when their thermal expansion is hindered. Further detailed investigations by means of continuous heating tests with a low heating rate were carried out on separately produced concrete cylinders. These tests showed that the pre-treatment of the PP-fibres causes earlier dehydration in conjunction with stagnation of thermal expansion of the concrete cylinders (temperature reduction from 180 °C to 170 °C). This is accompanied by in-creased acoustic emission activity during the thermal expansion tests. This leads to the assumption that the pre-treatment of PP-fibres results in earlier micro-crack development. However, it was not possible to confirm this assumption by microscopic examination of drilling cores with a diameter of 30 mm exposed to defined temperatures in the range between 150°C and 300°C. Microscopic obser-vations and additional X-ray 3D computed tomography (3D-CT) scans on miniaturised drilling cores exposed to temperature cycles showed a similar networking of fibre beds by means of micro-cracks in HSC for both fibre types. However, energy dispersive X-ray spectroscopy and wavelength disper-sive X-ray spectroscopy revealed fundamental differences in the penetration capacity of the fibre melts of the two fibre types. The increased penetration of the pre-treated PP-fibre melt revealed in these tests, confirms the initial working hypothesis.
Aufbauende Untersuchungen an Laborbetonen: Parameterstudie zu ausgewählten AKR-Einflussgrößen
(2017)
Gegenstand des Vortrags ist die Vorstellung der Ergebnisse der aufbauenden Untersuchungen an Laborbetonen im Forschungsvorhaben FUTURUM. Im konkreten Fall werden die Ergebnisse der Parameterstudie zu nachstehenden ausgewählten Einflussgrößen auf die schädigende AKR präsentiert:
- zyklische Beanspruchung durch Klima und Verkehr
- Einbautemperatur und Nachbehandlung
- Art der Oberflächentextur
- ausgewählte Prüfbedingungen bei der Klimawechsellagerung (KWL)
Die Basis für diese Untersuchungen bildeten großformatige Balken sowie Platten mit behinderter Schwindverformung, die aus den im ARS 04/2013 vorgegebenen Fahrbahndeckenbetonrezepturen unter Verwendung einer alkaliempfindlichen Gesteinskörnung hergestellt wurden. Folgende Ergebnisse wurden erzielt:
- moderate Förderung schädigender AKR durch zyklische Beanspruchung aus Klima und Verkehr
- unterschiedliche Förderung des AKR-Schädigungsprozesses bei verschiedenen Fahrbahn-deckenbetonen bei Erhöhung der Einbautemperatur von 15 auf 30 °C und sonst gleichbleibender Nachbehandlung (Folie)
(Oberbeton >8 / Unterbeton: moderat, Oberbeton 0/8: stärker ausgeprägt)
- verminderte KWL-Dehnung bei AKR-provozierender Lagerung beider Betonarten bei 30 °C durch Verschlechterung der Nachbehandlung (Windkanal, 5 m/s)
- Zunahme schädigender AKR in Abhängigkeit von der Art der Oberflächentextur (Besenstrich, Grinding/Grooving, Waschbeton)
- nichtlineare Zunahme der KWL-Dehnung mit Erhöhung der NaCl-Konzentration der Prüflösung (Bestätigung der Richtigkeit gewählter normativer NaCl-Konzentration)
- Verminderung der KWL-Dehnung durch Substitution der Frost-Tauwechselphase trotz vermindertem Tausalzeintrag
The accelerated concrete prism test (ACPT-60 °C) facilitates testing of alkali-silica reactivity of aggregates within five months. Manual measurement is usually conducted to determine expansion of test specimen every 28 days. This conventional procedure gives only limited insight to expansion behaviour of ASR-affected prisms. Due to the large time intervals, expansion exceeding the critical value of 0.3 mm/m is likely to be noticed late. Continuous recording resolves this problem and delivers beneficial information on the shape of the expansion curve.
Displacement transducers integrated into a special testing equipment developed at BAM put continuous measurement into practice. Additionally, ultrasonic velocity and acoustic emissions are measured in-situ and provide deeper insights into hydration and crack formation processes during the test.
Aiming for an automated testing method close to the German guideline, the following technical and methodical challenges arise. Changing of the vertical orientation of the prisms with every manual measurement as standardised cannot be implemented. Furthermore, preliminary results already proved true that cooling and heating cycles, as necessarily associated with each manual measurement, can evoke additional expansion. Therefore, interrupted and continuously measured expansions reveal systematic differences, indicating the necessity to adjust the threshold expansion value for automated testing.
Results presented in the paper: Different types of reactive aggregate have been tested applying continuous and manual expansion measurement to the concrete specimens. Development of continuously measured ultrasonic velocity and acoustic emissions of the aggregates tested diverge significantly while the expansion curves vary in shape and maximum strain. Prisms produced from a slowly reacting aggregate do not exhibit noticeable crack formation. It shows that comprehensive measuring helps describing and distinguishing ASR-damage mechanisms.
Models of ASR-induced expansion, available in the open literature, so far are validated with discontinuous data hardly tracing the modelled curve. Continuous measurement improves validation and further model development.
The primary aim of this paper is to analyze the impact of mechanical pre-damage and alkali–silica reaction (ASR) on the fracture mechanical properties of pavement concrete. For this purpose, a four point bending test was applied to large format beams to produce a defined level of cyclic pre-damage. The fatigue-induced concrete degradation process was simultaneously recorded using a testing procedure specifically developed for the purpose. In addition, fatigue-induced cracks on extracted drilling cores were spatially visualized and quantified using micro X-ray 3D-computed tomography (3D-CT). The storage of the small-format test specimens, with and without cyclic pre-damage, in an ASR-conducive environment showed that pre-damage leads to an increase in ASR damage processes. Subsequent structural mechanical investigations on small format specimens with and without pre-damage show that fatigue loading and ASR significantly influence fracture mechanical parameters of the concrete.