Filtern
Dokumenttyp
- Zeitschriftenartikel (6)
- Forschungsdatensatz (2)
- Beitrag zu einem Tagungsband (1)
- Preprint (1)
Sprache
- Englisch (10)
Schlagworte
- Multi photon lithography (2)
- 3D printing (1)
- AFM force distance curves (1)
- AFM friction analysis (1)
- AFM plastic deformation (1)
- Additive manufacturing (1)
- Calibration structure (1)
- Cantilever (1)
- Catheters (1)
- Cement hydration (1)
Organisationseinheit der BAM
In this work, reactive magnetron-sputtered Pb(Zr,Ti)O3 thin films were used to fabricate well-ordered nanodot arrays by means of nanosphere lithography (NSL). NSL is based on a two-step etch process by means of, firstly adjusting the diameter of polystyrene spheres in the self-assembled polymeric nanosphere mask using reactive ion etching, and secondly transferring the mask to the substrate by ion milling with adjusted heights. Hence, structures with different aspect ratios can be fabricated.
Piezoresponse force microscopy was used as the inspection tool on both non-patterned and patterned films. Both the topography and polarization out of plane and in plane was deduced in this mode. Grains of nanodots with low aspect ratio form domain structures comparable to domains in non-patterned films. In contrast to that, nanodots with a higher aspect ratio form particular structures. The in-plane amplitude images show mostly a bisectioned domain assembly, while the out-of-plane amplitude images show in some cases more complex structures like 'c'-shaped domains or multi-domains around a center domain.
The patterning of the ferroelectric material was shown to affect the formation of ferroelectric domains. The initial polycrystalline, randomly-ordered films are re-oriented and show domain structures depending on nanodisc diameter and aspect ratio. This may enable tailoring of ferroelectric materials in their piezoelectric and pyroelectric properties by patterning.
A specially designed scanning force microscope (SFM, atomic force microscope – AFM) was incorporated into the chamber of a commercial scanning electron microscope (SEM) to investigate vibrating SFM cantilevers at their resonance. Inherently, the spatial resolution of electron microscopy is higher than that of optical methods. In this paper we present vibration modes (eigenmodes) of two different SFM cantilevers. Their nonlinear behavior is also explored in order to depict their 2nd harmonics (twice the fundamental frequency). Imaging of the local vibration is performed by measuring the frequency- and phase-selective responses of the SE signal at different X and Y positions of the scanned electron beam.
In this work, Pb(Zr,Ti)O3 thin films were used to fabricate well-ordered nanodot arrays by means of nanosphere lithography. This technique is based on a two-step etch process that enables excellent control of the fabrication of ordered nanodisc arrays of defined height, diameter, and pitch. Piezoresponse force microscopy was used to investigate both non-patterned and patterned films. The topography and both the out-of-plane and the in-plane polarization were deduced in this mode. Grains of nanodots with a low aspect ratio form domain structures comparable to domains in non-patterned two-dimensional films. In contrast, nanodots with a higher aspect ratio form particular structures like bi-sectioned domain assemblies, c-shaped domains or multi-domains surrounding a center domain. The patterning of the ferroelectric material was shown to affect the formation of ferroelectric domains. The initial polycrystalline films with random polarization orientation re-orient upon patterning and then show domain structures dependent on the nanodisc diameter and aspect ratio.
Chemical admixtures like superplasticisers or stabilising agents are of ever increasing importance for modern concrete technology. They liberate the workability of concrete from its dependency on water content, and thus, open the gate towards innovative and future oriented concrete technologies such as self-compacting concrete.
Today, admixture addition has become common practice in concrete technology, but the understanding of their highly complex mode of operation is extremely difficult and demands for understanding of processes within the range between nanometres and centimetres.
Due to its complex time-dependent, multi-phase and multi-scale behaviour, flowable concrete systems are highly complicated and cannot be described comprehensively by simple models. It is therefore extremely challenging to identify the relevant parameters that predominantly control flow phenomena on different size scales, since these may occur on any scale between the nano scale (e.g. superplasticizer adsorption) and macro scale (e.g. grading of the aggregates). The present study discusses fundamental mechanisms at the interface between particle or hydrate surfaces and the fluid phase at a very early stage of concrete formation, and links these effects to macroscopic flow phenomena. Methods are discussed that appear promising interdisciplinary tools for enhancement of the understanding of the relevant interactions that are responsible for the macroscopic flow of flowable concrete.
Central venous port devices made of two different polymeric materials, thermoplastic polyurethane (TPU)and silicone rubber (SiR), were compared due their material properties. Both naïve catheters as well as catheters after removal from patients were investigated. In lab experiments the influence of various chemo-therapeutic solutions on material properties was investigated, where as the samples after removal were compared according to the implanted time inpatient. The macroscopic,mechanical performance was assessed with dynamic, specially adapted tests for elasticity. The degradation status of the materials was determined with common tools of polymer characterisation, such as infrared spectroscopy, molecular weight measurements and various methods of thermal analysis. The surface morphology was an alysed using scanning electron microscopy. A correlation between material properties and clinical performance was proposed. The surface morphology and chemical composition of the polyurethane catheter materials can potentially result in increased susceptibility of the catheter to bloodstream infections and thrombotic complications. The higher mechanic failure,especially with increasing implantation time of the silicone catheters is related to the lower mechanical performance compared to the polyurethane material as well as loss of barium sulphate filler particles near the surface of the catheter. This results in preformed microscopic notches, which act as predetermined sites of fracture.
With Direct Laser Writing (DLW) maturing in all aspects as a manufacturing technology a toolset for quality assurance must be developed. In this work we want to introduce a first of its kind test artifact. Test artifacts are standardized 3D models with specific geometric feature to evaluate the performance of writing parameters. Test artifacts are already common in other 3D additive manufacturing technologies e.g. Selective Laser Melting. The test artifact introduced in this work was developed in particular to accommodate 1) the high geometrical resolution of DLW structures and 2) the limited possibilities to examine the resulting structure. Geometric accuracy, surface adhesion as well as confocal raman spectroscopy results were considered when evaluating the design of the test artifact. We will explain the individual features and design considerations of our DLW test artifact. The difference between two slicers, Cura and 3DPoli, and the implications on measured feature sizes and the general shape is quantified. The measured geometries are used to derive a general design guide for a specific combination of photoresist, laser power and scanning speed and to analyse the geometric accuracy of a structure produced using these guidelines.
2PP-TestArtifact
(2023)
This repository contains a test artifact (TA), also called test structure, designed for two-photon polymerization (also known as Direct Laser Writing (DLW) or Two/Multi-photon lithography (2PA/MPA)). Test artifacts can be used to compare structures, to check options used by the slicer, check the state of the 2PP machine itself or to get a construction guidelines for a certain combination of power, velocity and settings.
The associated paper can be found here: https://dx.doi.org/10.1088/1361-6501/acc47a
General ideas behind the test artifact:
1. optimized for 2PP-DLW
2. should be fast and easy to analyse with optical microscopy or 3. scanning electron microscopy without tilt.
3. short time to fabricate
4. include a reasonable amount of different features
5. bulk and small structures on the substrate
With femtosecond-laser direct writing (fs-LDW) maturing in all aspects as a manufacturing technology, a toolset for quality assurance must be developed. In this work we introduce a first of its kind test artifact. Test artifacts are standardized 3D models with specific geometric features to evaluate the performance of writing parameters. Test artifacts are already common in other 3D additive manufacturing technologies e.g. selective laser melting. The test artifact introduced in this work was developed in particular to accommodate the high geometrical resolution of fs-LDW structures and the limited possibilities to examine the resulting structure. Geometric accuracy, surface adhesion as well as confocal Raman spectroscopy results were considered when evaluating the design of the test artifact. We will explain the individual features and design considerations of our fs-LDW test artifact. The difference between two slicers, Cura and 3DPoli, and the implications on measured feature sizes and the general shape is quantified. The measured geometries are used to derive a general design guide for a specific combination of photoresists, laser power and scanning speed and to analyze the geometric accuracy of a structure produced using these guidelines. The shown test artifact is publicly available as STL file on GitHub (https://github.com/BAMresearch/2PP-TestArtifact) and in the supplement.
Test artifact for fs-LDW
(2023)