Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (177) (entfernen)
Schlagworte
- MALDI-TOF MS (57)
- Polylactide (42)
- Cyclization (26)
- MALDI (17)
- Ring-opening polymerization (17)
- Polycondensation (15)
- MALDI TOF MS (8)
- Polymerization (8)
- Transesterification (8)
- Pollen (7)
- Ring-expansion polymerization (7)
- Catalyst (6)
- Crystallization (6)
- Mass spectrometry (6)
- Crystalinity (5)
- Isosorbide (5)
- Lactide (5)
- Polyester (5)
- Polymere (5)
- Polymers (5)
- Catalysts (4)
- Ionization (4)
- MALDI Massenspektrometrie (4)
- MALDI-TOF mass spectrometry (4)
- Polyesters (4)
- Polylactides (4)
- Bismuth (3)
- ICP-MS (3)
- Imaging (3)
- Liquid chromatography (3)
- Polyglycolide (3)
- ROPPOC (3)
- Ring opening polymerization (3)
- SEC (3)
- Silver nanoparticles (3)
- Small-angle X-ray scattering (3)
- Adsorption (2)
- Amphiphiles (2)
- Biobased polymers (2)
- Biodegradable (2)
- Blends (2)
- Block copolymers (2)
- Catechol (2)
- Chromatographie (2)
- Conductive carbon tape (2)
- Coupling methods (2)
- Crosslinking (2)
- Crystals (2)
- Cyclic (2)
- Cyclopolymerization (2)
- Dispersity (2)
- Epsilon-caprolactone (2)
- FTIR (2)
- Field-flow fractionation (2)
- Isotope dilution analysis (2)
- Kopplung (2)
- MALDI mass spectrometry (2)
- MALDI-TOF-MS (2)
- MS/MS (2)
- Macrocycles (2)
- Massenspektrometrie (2)
- Multivariate statistics (2)
- Polymer (2)
- Polymerisation (2)
- Polystyrene (2)
- Polyurethane (2)
- Polyurethanes (2)
- Principal component analysis (2)
- Reversible addition fragmentation chain transfer (RAFT) (2)
- Ring-opening Polymerization (2)
- SAXS (2)
- Sample preparation (2)
- Sample pretreatment (2)
- Synthesis (2)
- Thermal degradation (2)
- Tin acetates (2)
- Tin catalysts (2)
- 2-oxazoline (1)
- A4F (1)
- AET (1)
- AFM (1)
- Adhesion promotion (1)
- Alternating co-poly(ether pyridine)s (1)
- Amphiphilic polymers (1)
- Annealing (1)
- Application (1)
- Aromatic organic compounds, (1)
- Aromatic pollutants (1)
- Artificial weathering (1)
- Aryl iodides (1)
- Asymmetric flow filed-flow fractionation (1)
- Asymmetrical flow field flow fractionation (AF4) (1)
- Attenuated total reflectance-Fourier transorm infrared spectroscopy (1)
- Biobased (1)
- Biodegradability (1)
- Biodegradable polyesters (1)
- Biopolymers (1)
- Biosourced isosorbide (1)
- Blockcopolymer (1)
- CRM (1)
- Caco-2 cells (1)
- Caesium (1)
- Capillary electrophoresis (1)
- Capillary electrophoresis (CE) (1)
- Carbon fiberepoxy resin laminates (1)
- Carboxyl group (1)
- Catalytic ability (1)
- Cationic ring opening polymerization (1)
- Cationization (1)
- Chain scission (1)
- Chemical reduction of functional groups (1)
- Chromatography (1)
- Classification (1)
- Click chemistry (1)
- Conjugated oligomers (1)
- Controlled radical polymerization (1)
- Conversion (1)
- Copolyester (1)
- Copolymer composition (1)
- Copolymer sequence (1)
- Copolymeranalytik (1)
- Copolymerization (1)
- Cotton effect (1)
- Coupling (1)
- Cyclics (1)
- Cyclisation (1)
- Cycloaddition (1)
- Cycloparaphenylenes (1)
- DCTB (1)
- Degradation (1)
- Dendrimers (1)
- Dendrons (1)
- Dried droplet (1)
- Droplet (1)
- Dynamic light scattering (1)
- ESI (1)
- ESI-Massenspektrometrie (1)
- Electron paramagnetic resonance study (1)
- Electrospray (1)
- Electrospray ionization (1)
- Electrospray ionization (ESI) (1)
- Epsilon-Caprolactone (1)
- Epsilon-caprolactone (e-CL) (1)
- Equilibration (1)
- Europium (1)
- Field flow fractionation (1)
- Foldamers (1)
- Fractionation of polymers (1)
- Fragmentierung (1)
- Friction (1)
- Ft-IR (1)
- Functionalized graphene nanoribbons (1)
- Fundamentals (1)
- Glycodendrimers (1)
- Glycolide (1)
- Gradient chromatography (1)
- Gradient elution (1)
- Gradient elution liquid chromatography (GELC) (1)
- Graphene monomers (1)
- Graphene nanoribbons (1)
- Graphene wires (1)
- Green chemistry (1)
- HPLC (1)
- Hafnium (1)
- Heavy metals (1)
- Hexabenzocoronene (1)
- Hierarchical cluster analysis (1)
- Hierarchical self-assembly (1)
- High performance liquid chromatography (1)
- Host–guest systems (1)
- Humidity (1)
- Hybrid nanoparticles (1)
- Hydrolytic degradation (1)
- Hyphenated techniques (1)
- Imaging MS (1)
- In situ EXAFS (1)
- In situ SAXS/WAXS (1)
- In vitro digestion (1)
- Inductively coupled plasma-mass spectrometry (1)
- Inlet ionization (1)
- Intrinsic viscosity (1)
- Ion mobility (1)
- Ionization mass spectrometry (1)
- Iron oxide nanoparticles (1)
- Irreversible polycondensation (1)
- Isophthalic acid (1)
- Jacobsen-Stockmayer theory (1)
- Kopplungsmethoden (1)
- L-lactide (1)
- LC-MS coupling (1)
- Lactides (1)
- Lacunary Keggin ion (1)
- Lanthanide ions (1)
- Laser-induced redox reactions (1)
- Layer topography (1)
- Lead ions (1)
- Light scattering (LS) (1)
- Liquid adsorption chromatography (1)
- Liquid adsorption chromatography at critical conditions (1)
- Liquid chromatography at critical conditions (1)
- Liquid chromatography under critical conditions (LCCC) (1)
- MALDI Imaging MS (1)
- MALDI TOF Massenspektrometrie (1)
- MALDI TOF mass spectrometry (1)
- MALDI-TOF (1)
- MALDI-TOF MS/MS (1)
- MOF (1)
- Mass Spectrometry (1)
- Mass spectrometry imaging (1)
- Materials Chemistry (1)
- Matrices (1)
- Matrix segregation (1)
- Matrix-assisted ionization ion mobility spectrometry mass spectrometry (1)
- Matrix-assisted laser desorption (1)
- Matrix-assisted laser desorption/ionization (1)
- Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS) (1)
- Matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometry (1)
- Mechanism (1)
- Mechanism of polymerization (1)
- Mega-dalton (1)
- Metal ion complexation (1)
- Metal ion-intradendrimer complexes (1)
- Metal triflates (1)
- Microwave (1)
- Moisture (1)
- Molar mass determination (1)
- Molar mass distribution (1)
- Molecular masses (1)
- Molecular recognition (1)
- Morphology (1)
- Multicyclic polymers (1)
- Multivariate Statistics (1)
- Multivariate analyses (1)
- N-vinyl pyrrolidone (1)
- Nanolithography (1)
- Nanoparticle (1)
- Nanoparticles (1)
- Nanoparticles separation asymetrical flow field flow fractionation (1)
- Nanoparticles with same nominal diameter (1)
- Networks (1)
- Oligoazobenzene (1)
- Oligospiroketals (1)
- On-surface polymerization (1)
- Organic Chemistry (1)
- PCA (1)
- PET (1)
- Partial least square discriminant analysis (PLS-DA) (1)
- Pentafluoropyridine (1)
- Phenolic acid (1)
- Phenolic compounds (1)
- Phenyleneethynylenes (1)
- Phosphonate esters (1)
- Photoligation (1)
- Photooxidation (1)
- Photoswitchable (1)
- Plasma (1)
- Plasma modification (1)
- Pollen grains (1)
- Poly(ether-phosphoramide)s sulfides (1)
- Poly(ethylene glycol) (1)
- Poly(ethylene terephthalate) (1)
- Polyaddition (1)
- Polycaprolactone (1)
- Polycarbonate-co-dimethylsiloxane copolymer (1)
- Polycondensations (1)
- Polyelectrolytes (1)
- Polyethylene oxide (1)
- Polyforamidine (1)
- Polykondensation (1)
- Polymer MALDI (1)
- Polymer blends (1)
- Polymer film (1)
- Polymer reference materials (1)
- Polymerization mechanisms (1)
- Polymers and Plastics (1)
- Polyoxometalates (1)
- Polysarcosine (1)
- Principal component analysis (PCA) (1)
- Quantification (1)
- ROMP (1)
- Raman (1)
- Renewable resources (1)
- Reversible addition/fragmentation chain transfer (RAFT) (1)
- Ring opening polymerization (ROP) (1)
- Ring-opening Polymerisation (1)
- Ring-opening polymerizations (1)
- Salicylate (1)
- Sample loss (1)
- Self-assembly (1)
- Semi-interpenetrating networks (1)
- Silica gel modification (1)
- Size exclusion chromatography (1)
- Size exclusion chromatography (SEC) (1)
- Size-exclusion chromatography (1)
- Sn catalysts (1)
- Soft ionization mass spectrometry (ESI, MALDI) (1)
- Software (1)
- Solvent-free (1)
- Sonoga (1)
- Sorption isotherm (1)
- Sorption mechanism (1)
- Speciation (1)
- Spirocyclic (1)
- Stereocomplex (1)
- Succinic acid (1)
- Sulfobetaines (1)
- Supramolecular chemistry (1)
- Surface coating (1)
- TPU (1)
- Target plate material (1)
- Telechelic polyesters (1)
- Thermo-desorption (1)
- Thermochemistry (1)
- Thin polymer layers (1)
- Tin(II)octanoate (1)
- Toxicity (1)
- Toxicology (1)
- Triazenes (1)
- Two-dimensional off-line coupling (1)
- Two-dimensional-liquid chromatography (2D-LC) (1)
- UPLC (1)
- UV degradation (1)
- UV radiation (1)
- Ultraschallfalle (1)
- Universal calibration (1)
- Vacuum ionization (1)
- Water-soluble polymers (1)
- X-ray photoelectron spectroscopy (1)
- Zinc catalyst (1)
- a2 + b3 polycondensation (1)
- cyclization (1)
- dispersity (1)
- mass spectra (1)
- mass spectrometry (1)
- polycondensation (1)
- polyesters (1)
- polyionic liquids (1)
- reversible addition fragmentation chain transfer (RAFT) polymerization (1)
- ring-expansion polymerization (1)
- surface modification (1)
Organisationseinheit der BAM
- 6 Materialchemie (76)
- 6.3 Strukturanalytik (76)
- 1 Analytische Chemie; Referenzmaterialien (5)
- 1.2 Biophotonik (2)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
- 6.6 Physik und chemische Analytik der Polymere (2)
- 7 Bauwerkssicherheit (2)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (2)
- 1.0 Abteilungsleitung und andere (1)
- 1.3 Instrumentelle Analytik (1)
Modelling plasma-induced reactions on polymer surfaces using aliphatic self-assembling and LB layers
(1998)
The hydrolytic degradation of technical poly(ethylene terephthalate) (PET) was investigated by means of different methods such as size-exclusion chromatography (SEC), viscometry, light-scattering, thin-layer chromatography, end-group titration, and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The long-term degradation was simulated by exposing PET filament yarns to aqueous neutral conditions at 90°C for up to 18 weeks. By means of MALDI-MS and thin-layer chromatography, the formation of different oligomers was obtained during polymer degradation. As expected, an ester scission process was found generating acid terminated oligomers (H-[GT]m-OH) and T-[GT]m-OH and ethylene glycol terminated oligomers (H-[GT]m-G), where G is an ethylene glycol unit and T is a terephthalic acid unit. Additionally, the scission of the ester bonds during the chemical treatment led to a strong decrease in the number of cyclic oligomers ([GT]m). The occurrence of di-acid terminated species demonstrated a high degree of degradation.
Technical waxes and paraffins were investigated using supercritical fluid chromatography (SFC), matrix-assisted laser-desorption/ionization mass spectrometry (MALDI-MS) and size-exclusion chromatography (SEC). SEC enables the simultaneous determination of molecular masses up to high values and molecular mass distributions. The resolution of homologous species, however, is poor. In this respect the use of SFC is advantageous. Proper resolution of homologues may be provided up to Mr~1200 without great difficulty. To compare these chromatographic results MALDI-MS was applied for the determination of molecular masses and mass distributions in technical waxes for the first time. Using reflectron mode excellent MALDI mass spectra could be achieved in the molecular mass range up to 1000 Da. The mean values of the molecular masses calculated by MALDI-MS were in sufficient agreement with those of SFC. In the linear mode of MALDI-MS molecular masses could be determined to nearly 3000 Da. Beyond this mass range SEC still remains the method of choice. Advantages and difficulties of the used methods are discussed in this paper.
This article reports round-robin tests dealing with static light scattering (LS), size exclusion chromatography (SEC), and viscometry measurements of 10 reference materials of various polymer classes: poly(styrene)s (PS), poly(methyl methacrylate)s (PMMA), poly(ethylene oxide)s (PEO), and poly(lactide)s (PLA).
In the certificates, molar masses and intrinsic viscosities as well as their uncertainties are specified. Additional values from nuclear magnetic resonance (NMR), infrared spectroscopy (IR), differential scanning calorimetry (DSC), melt flow index (MFR), and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS), which were determined exclusively in BAM laboratories are given, as well.
These results represent the base for the BAM certification work of creating polymer reference materials according to the BAM Guidelines for the Production and Certification of BAM Reference Materials, a version of the European guidelines (BCR/01/97). These samples are available for third-party user.
The detection limits of matrix-assisted laser desorption/ionisation mass spectrometry (MALDI-MS) by semi-online coupling with chromatography were investigated using various mixtures of polyethylene oxides (PEOs) with different end groups. In contrast to the common dried-droplet sample preparation technique, which results in an inhomogeneous sample-to-matrix ratio within the MALDI spot, the used coupling technique offers a very high reproducibility combined with surpassing sensitivity of a few femtograms over a broad range of sample-to-matrix ratios. These results are in correlation with the results of the recently established solvent-free MALDI-TOFMS method utilising the grinding approach and are also of assistance towards the more theoretical aspect of MALDI that suggests that there is no necessity for an analyte incorporation into a matrix crystal for excellent matrix-assistance.
Polybutadienes (PB) and polyisoprenes (PI) with various molecular weights and polydispersities were epoxidized applying two different synthetic routes. The degree of epoxidation was determined by means of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS). It has been found that the degree of functionalization of polybutadiene is generally lower than that for polyisoprenes. Additionally, PB shows lower degrees of epoxidation at higher masses, whereas the level of functionalization of PI was unaffected by the molar mass. Coupling of gel permeation chromatography (GPC) with MALDI-TOF mass spectrometry was successfully used for the investigation of epoxidized polymers with higher masses. Using mass spectra of single fractions, the degree of epoxidation could be determined and applied for a calibration of GPC.
Various copolyesters of lactide, isosorbide, and terephthalic acid are prepared by a two-step process performed in a 'one-pot' procedure, beginning with an isosorbide-initiated oligomerization of L-lactide followed by polycondensation with terephthaloyl chloride using SnCl2 as a catalyst for both steps. The SEC data show the formation of random copolyesters with high polydispersities as a consequence of the relatively high fraction of cyclics proved by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS). The glass-transition temperatures (89–180 °C) obey an almost linear trend with the molar composition. The thermostability decreases with increasing lactide content. The successful incorporation of phenyl phosphate results in copolyesters of lower inflammability.
RATIONALE
A fast and reliable online identification of pollen is not yet available. The identification of pollen is based mainly on the evaluation of morphological data obtained by microscopic methods.
METHODS
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS) was applied to the analysis of extracts and milled pollen samples. The obtained MALDI data were explored for characteristic peak patterns which could be subjected to a multivariate statistical analysis.
RESULTS
Two sample preparation methods are presented, which require only minimal or no chemical extraction of the pollen. MALDI pollen spectra could be recorded showing various peak patterns. A multivariate statistics approach allowed the classification of pollen into clusters indicating similarities and differences between various species.
CONCLUSIONS
These results demonstrate the potential and the reliability of MALDI-TOF MS for the identification and, in combination with multivariate statistics, also for the classification of pollen.
Synthesis of terpene-poly(ethylene oxide)s by t-BuP4-promoted anionic ring-opening polymerization
(2012)
Terpene alcohols (menthol, retinol, cholesterol, and betulin) together with the phosphazene base t-BuP4 were used as initiating systems for anionic ring-opening polymerization of ethylene oxide. The polymerizations were conducted in a controlled manner with the initial molar ratio of t-BuP4 to hydroxyl groups of 0.01–0.2, yielding a series of biohybrid polymers comprising terpene entities and poly(ethylene oxide) (PEO) chains with low polydispersities and tunable compositions (57–87 wt% of PEO). Samples were characterized by NMR and UV/visible spectroscopy, MALDI-TOF mass spectrometry, and size exclusion chromatography; thermal properties were studied by differential scanning calorimetry. The concept of this study opens a new toolbox of terpene-based biohybrid polymers with variable properties and functions.
RATIONALE
The fast and univocal identification of different species in mixtures of pollen grains is still a challenge. Apart from microscopic evaluation and Raman spectroscopy, no other techniques are available.
METHODS
Matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry was applied to the analysis of extracts of single pollen grains and pollen mixtures. Pollen grains were fixed, treated and covered with matrix directly on the MALDI target.
RESULTS
Clearly resolved MALDI ion intensity images could be obtained enabling the identification of single pollen grains in a mixture.
CONCLUSIONS
Our results demonstrate the potential and the suitability of MALDI imaging mass spectrometry as an additional method for the identification of pollen mixtures.
The development of a facile covalent strategy for the fabrication of organic conducting polymers (OCPs)/carbon nanotubes (CNTs) based molecular hybrid materials remains a challenge and is expected to address the detrimental intrinsic bundling issue of CNTs. In view of the pristine CNTs' ability to undergo Diels–Alder reactions with dienes, we report the synthesis of a novel poly(3-hexylthiophene) (P3HT) based organic conducting polymer (OCP) with terminal cyclopentadienyl (Cp) groups. The synthetic strategy employed is based on a combination of in situ end group functionalization via Grignard metathesis (GRIM) polymerization and a subsequent end group switching via reaction with nickelocene. Characterization data from Matrix-assisted laser desorption-ionization time-of-flight mass spectrometry (MALDITOF MS) fully support the successful synthesis of monofunctional Cp-capped P3HT, which was found to be highly reactive toward dienophile end-capped polystyrene (PS). The Cp-capped P3HT was subsequently ligated to the surface of pristine single walled CNTs (SWCNTs). The resulting P3HT/SWCNTs molecular hybrid material was characterized using thermogravimetric analysis (TGA), elemental analysis (EA), X-ray photoelectron spectroscopy (XPS), and high resolution transmission electron microscopy (HRTEM). The data from TGA, EA, and XPS were used to quantitatively deduce the grafting density. P3HT/SWCNTs prepared with Cp capped P3HT was found to contain 2 times more P3HT than the reference sample, featuring a grafting density of 0.0510 chains·nm–2 and a periodicity of 1 P3HT chain per 748 carbon atoms of the SWCNTs. HRTEM revealed individual SWCNTs wrapped with P3HT whereas in the reference sample P3HT was adsorbed on the bundles of the SWCNTs. The results presented here provide a new avenue for designing novel materials based on CNTs and OCPs.
Isosorbide, succinyl chloride and isophthaloyl chloride are polycondensed under various reaction conditions. The heating in bulk with or without catalysts as well in an aromatic solvent without catalyst, and polycondensation with the addition of pyridine only yield low molar mass copolyesters. However, heating in chlorobenzene with addition of SnCl2 or ZnCl2 produces satisfactory molar masses. The number average molecular weights (Mn) of most copolyesters fall into the range of 7000–15,000 Da with polydispersities (PD) in the range of 3–9. The MALDI-TOF mass spectra almost exclusively displayed peaks of cyclics indicating that the chain growth was mainly limited by cyclization and not by side reactions, stoichiometric imbalance or incomplete conversion. The glass-transition temperatures increased with the content of isophthalic acid from 75 to 180 °C and the thermo-stabilities also followed this trend.
Matrix-assisted laser desorption/ionization-timeof-flight (MALDI-TOF) imaging of polystyrenes with various molecular masses was applied to study spatial molecular mass distribution of polymers in sample spots prepared by the 'dried droplet' method. When different solvents and target surfaces were examined, a segregation of single homologous polymers was observed depending upon the evaporation rate of the solvent. For the observed Patterns left by the evaporating droplet, a hypothesis is offered taking into account different hydrodynamic interactions and diffusion.
The results illustrate that spot preparation using the conventionally 'dried droplet' method is prone to artifacts and should be avoided for reliable and reproducible MALDI mass spectrometry experiments with regards to the Determination of molecular masses and mass distributions.
Efficient Cu-catalyzed 1,3-dipolar cycloaddition reactions have been used to prepare two series of three regioisomers of G-1 and G-2 poly(triazole-pyridine) dendrons. The G-1 and G-2 dendrons consist of branched yet conformationally pre-organized 2,6-bis(phenyl/pyridyl-1,2,3-triazol-4-yl)pyridine (BPTP) monomeric and trimeric cores, respectively, carrying one focal and either two or four peripheral alkyl side chains. In the solid state, the conformation and supramolecular organization were studied by means of a single crystal X-ray structure analysis of one derivative. At the liquidsolid interface, the self-assembly behavior was investigated by scanning tunneling microscopy (STM) on graphite surfaces. Based on the observed supramolecular organization, it appears that the subtle balance between conformational preferences inherent in the dendritic backbone on the one side and the adsorption and packing of the alkyl side chains on the graphite substrate on the other side dictate the overall structure formation in 2D.
A new approach that utilizes MALDI-TOF imaging mass spectrometry as a new detector for polymer chromatography is presented. For the first time, the individual retention behavior of single structural units of polyethylene oxide (PEO)/polypropylene oxide (PPO) copolymers and changes of the copolymer composition could be monitored. Composition specific calibration curves could be easily obtained by displaying the copolymer ion intensity data. This approach provides completely new insights in the chromatographic principle of copolymer separation and could be used to easily modify and adapt conditions for separation. In combination with electrospray deposition, homogeneous sample/matrix traces of surprisingly high spatial resolution could be obtained.
Ring-opening polymerization of N-substituted glycine N-carboxyanhydrides (NCAs) was applied to prepare a series of well-defined poly(N-C3 glycine)s (C3 = n-propyl, allyl, propargyl, and isopropyl), polypeptoids, with molecular weights in the range of 1.8–6.6 kg mol–1. Poly(N-isopropyl glycine), a previously unreported polypeptoid, could be obtained by bulk polymerization of the corresponding NCA in the melt. The samples were characterized by spectroscopy (NMR and FT-IR), size exclusion chromatography (SEC), and matrix-assisted laser desorption/ionization time-of-flight mass spectroscopy (MALDI–ToF MS). The polymers could be dispersed in water up to 20–40 g L–1; the poly(N-propargyl glycine) was not soluble in water. Turbidity measurements of the three water-soluble polypeptoids illustrated cloud point temperatures dependent on structural and electronic properties of the side chain. The cloud point temperatures were found to increase in the order C3 = n-propyl (15–25 °C) < allyl (27–54 °C) < isopropyl (47–58 °C). Long-term annealing of the aqueous solution of poly(N-{n-propyl} glycine) and poly(N-allyl glycine) above the cloud point temperature resulted in the formation of crystalline microparticles with melting points of 188–198 and 157–165 °C (differential scanning calorimetry, DSC), respectively, and rose bud type morphology (scanning electron microscopy, SEM).
Numerous water-initiated polymerizations of εCL are conducted in bulk with variation of catalyst, reaction time, and temperature. The conversions are determined by 1H NMR and the molar masses by SEC measurements. For polymerizations at 100 °C, Bi triflate and Hf triflate are used as catalysts, whereas at 140 °C, Al triflate, Sn(II) triflate, SnCl2, HfCl4, BiCl3, and LaCl3 are used. In addition to a closed reaction vessel, experiments are also performed with stirring in a vacuum. Under these conditions, the best catalyst (SnCl2) yields 2–3 times higher molar masses and mass spectra indicate a significant higher fraction of cyclic polymers. The results prove that a modification of the procedure may stimulate a polycondesation process without change of catalyst, time, and temperature.
A solvent-free homogenization/transfer matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) method is described for the preparation and precise transfer of up to 100 samples simultaneously on a single MALDI plate. This method is demonstrated using a poly(ethylene oxide) (PEO) mixture consisting of different molecular weights (500-6000) and end groups (PEO, dimethoxy-PEO, monomethoxy monomethacrylate-PEO, and dimethacrylate-PEO) that was fractionated using liquid adsorption chromatography at critical conditions. Off-line fractionation is performed prior to the on-target homogenization/transfer solvent-free sample preparation and MALDI mass analysis. The miniaturization of the solvent-free MALDI approach allowed analysis of less than 2 g per PEO component per fraction corresponding to ~200 pmol for PEO 6000. The amounts of polymer sample used for LC separation and the quality of the MS results are equivalent to the "dry spray" method; however, three times more fractions were collected and analyzed with the newly developed hyphenated approach. The off-line method eliminates optimization of, for example, spray conditions or spreading of organic solvents on the MALDI plate that occurs with droplet deposition methods. The widespread applications of MALDI make this solvent-free, multisample method particularly important as it expands the capabilities for obtaining mass measurements with great efficiencies in areas with increased sample numbers. In addition, the solvent-free method is well suited for automated MALDI analysis as it virtually eliminates the "dead-spot" phenomenon.