Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (178)
- Vortrag (39)
- Beitrag zu einem Tagungsband (16)
- Posterpräsentation (13)
- Beitrag zu einem Sammelband (9)
- Buchkapitel (2)
Schlagworte
- MALDI-TOF MS (62)
- Polylactide (44)
- Cyclization (26)
- MALDI (21)
- Ring-opening polymerization (17)
- Polycondensation (15)
- MALDI TOF MS (10)
- Mass spectrometry (9)
- Pollen (8)
- Polymerization (8)
- Transesterification (8)
- Polymers (7)
- Ring-expansion polymerization (7)
- Catalyst (6)
- Crystalinity (6)
- Crystallization (6)
- Ionization (6)
- Polymere (6)
- Catalysts (5)
- Isosorbide (5)
- Lactide (5)
- Polyester (5)
- MALDI Massenspektrometrie (4)
- MALDI-TOF mass spectrometry (4)
- Polyesters (4)
- Polylactides (4)
- Biobased polymers (3)
- Bismuth (3)
- Cyclic (3)
- ICP-MS (3)
- Imaging (3)
- Liquid chromatography (3)
- Multivariate statistics (3)
- Polyglycolide (3)
- Polymer (3)
- Polymerisation (3)
- Polyurethane (3)
- ROPPOC (3)
- Ring opening polymerization (3)
- SEC (3)
- Silver nanoparticles (3)
- Small-angle X-ray scattering (3)
- Adsorption (2)
- Amphiphiles (2)
- Biodegradable (2)
- Blends (2)
- Block copolymers (2)
- Catechol (2)
- Chromatographie (2)
- Chromatography (2)
- Conductive carbon tape (2)
- Coupling methods (2)
- Crosslinking (2)
- Crystals (2)
- Cyclopolymerization (2)
- Dispersity (2)
- ESI (2)
- Electrospray ionization (2)
- Epsilon-caprolactone (2)
- FTIR (2)
- Field-flow fractionation (2)
- Isotope dilution analysis (2)
- Kopplung (2)
- Liquid adsorption chromatography (2)
- MALDI mass spectrometry (2)
- MALDI-TOF-MS (2)
- MS/MS (2)
- Macrocycles (2)
- Massenspektrometrie (2)
- Matrix-assisted laser desorption/ionization (2)
- Plasma modification (2)
- Polystyrene (2)
- Polyurethanes (2)
- Principal component analysis (2)
- Reversible addition fragmentation chain transfer (RAFT) (2)
- Ring-opening Polymerization (2)
- SAXS (2)
- Sample preparation (2)
- Sample pretreatment (2)
- Synthesis (2)
- TPU (2)
- Thermal degradation (2)
- Tin acetates (2)
- Tin catalysts (2)
- 2-oxazoline (1)
- A4F (1)
- AET (1)
- AFM (1)
- Abbauverhalten (1)
- Adhesion promoting interlayers (1)
- Adhesion promotion (1)
- Alternating co-poly(ether pyridine)s (1)
- Amphiphilic polymers (1)
- Annealing (1)
- Application (1)
- Aromatic organic compounds, (1)
- Aromatic pollutants (1)
- Artificial weathering (1)
- Aryl iodides (1)
- Asymmetric flow filed-flow fractionation (1)
- Asymmetrical flow field flow fractionation (AF4) (1)
- Attenuated total reflectance-Fourier transorm infrared spectroscopy (1)
- Bewitterung (1)
- Bioabbaubare Polymere (1)
- Biobased (1)
- Biodegradability (1)
- Biodegradable polyesters (1)
- Biopolymers (1)
- Biosourced isosorbide (1)
- Blockcopolymer (1)
- CRM (1)
- Caco-2 cells (1)
- Caesium (1)
- Capillary electrophoresis (1)
- Capillary electrophoresis (CE) (1)
- Carbon capture (1)
- Carbon fiberepoxy resin laminates (1)
- Carboxyl group (1)
- Catalytic ability (1)
- Cationic ring opening polymerization (1)
- Cationization (1)
- Chain scission (1)
- Chemical conversion of functional groups (1)
- Chemical reduction of functional groups (1)
- Classification (1)
- Click chemistry (1)
- Climate change (1)
- Conjugated oligomers (1)
- Controlled radical polymerization (1)
- Conversion (1)
- Copolyester (1)
- Copolymer composition (1)
- Copolymer sequence (1)
- Copolymeranalytik (1)
- Copolymerization (1)
- Copolymers (1)
- Cotton effect (1)
- Coupling (1)
- Coupling techniques (1)
- Crystallinity (1)
- Cyclics (1)
- Cyclisation (1)
- Cycloaddition (1)
- Cycloparaphenylenes (1)
- DCTB (1)
- Degradation (1)
- Dendrimers (1)
- Dendrons (1)
- Depollution (1)
- Desorption (1)
- Dried droplet (1)
- Droplet (1)
- Dynamic light scattering (1)
- ESI-Massenspektrometrie (1)
- ESI-TOF MS (1)
- Electron paramagnetic resonance study (1)
- Electrospray (1)
- Electrospray ionization (ESI) (1)
- Epsilon-Caprolactone (1)
- Epsilon-caprolactone (e-CL) (1)
- Equilibration (1)
- Europium (1)
- Feuchte (1)
- Field flow fractionation (1)
- Foldamers (1)
- Fractionation of polymers (1)
- Fragmentierung (1)
- Friction (1)
- Ft-IR (1)
- Functionalized graphene nanoribbons (1)
- Fundamentals (1)
- Glycodendrimers (1)
- Glycolide (1)
- Gradient chromatography (1)
- Gradient elution (1)
- Gradient elution liquid chromatography (GELC) (1)
- Graphene monomers (1)
- Graphene nanoribbons (1)
- Graphene wires (1)
- Green chemistry (1)
- HPLC (1)
- Hafnium (1)
- Heavy metals (1)
- Hexabenzocoronene (1)
- Hierarchical cluster analysis (1)
- Hierarchical self-assembly (1)
- High performance liquid chromatography (1)
- Host–guest systems (1)
- Humidity (1)
- Hybrid nanoparticles (1)
- Hydrolytic degradation (1)
- Hyperbranched polyesters (1)
- Hyphenated techniques (1)
- Imaging MS (1)
- Imaging techniques (1)
- In situ EXAFS (1)
- In situ SAXS/WAXS (1)
- In vitro digestion (1)
- Inductively coupled plasma-mass spectrometry (1)
- Inlet ionization (1)
- Intrinsic viscosity (1)
- Ion mobility (1)
- Ionization mass spectrometry (1)
- Iron oxide nanoparticles (1)
- Irreversible polycondensation (1)
- Isophthalic acid (1)
- Jacobsen-Stockmayer theory (1)
- Klassifizierung (1)
- Kopplungsmethoden (1)
- L-lactide (1)
- LC-MS coupling (1)
- Lactides (1)
- Lacunary Keggin ion (1)
- Lanthanide ions (1)
- Laser-induced redox reactions (1)
- Layer topography (1)
- Lead ions (1)
- Light scattering (LS) (1)
- Linear (1)
- Liquid adsorption chromatography at critical conditions (1)
- Liquid chromatography at critical conditions (1)
- Liquid chromatography under critical conditions (LCCC) (1)
- Lubricant (1)
- MALDI Imaging (1)
- MALDI Imaging MS (1)
- MALDI TOF Massenspektrometrie (1)
- MALDI TOF mass spectrometry (1)
- MALDI-TOF (1)
- MALDI-TOF MS/MS (1)
- MALDI-TOF Mass Spectrometry (1)
- MALDI-TOF Massenspektrometrie (1)
- MALDI-ToF MS (1)
- MOF (1)
- Mass Spectrometry (1)
- Mass spectrometry imaging (1)
- Materials Chemistry (1)
- Matrices (1)
- Matrix segregation (1)
- Matrix-assisted ionization ion mobility spectrometry mass spectrometry (1)
- Matrix-assisted laser desorption (1)
- Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS) (1)
- Matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometry (1)
- Mechanism (1)
- Mechanism of polymerization (1)
- Mega-dalton (1)
- Metal ion complexation (1)
- Metal ion-intradendrimer complexes (1)
- Metal triflates (1)
- Metal-polymer interactions (1)
- Metal-polymer systems (1)
- Micro manufacturing (1)
- Microwave (1)
- Moisture (1)
- Molar mass determination (1)
- Molar mass distribution (1)
- Molecular masses (1)
- Molecular recognition (1)
- Morphology (1)
- Multicyclic polymers (1)
- Multiphysics simulations (1)
- Multivariate Analyse (1)
- Multivariate Statistics (1)
- Multivariate analyses (1)
- N-vinyl pyrrolidone (1)
- Nanolithography (1)
- Nanoparticle (1)
- Nanoparticles (1)
- Nanoparticles separation asymetrical flow field flow fractionation (1)
- Nanoparticles with same nominal diameter (1)
- Networks (1)
- Nässe (1)
- Oligoazobenzene (1)
- Oligospiroketals (1)
- On-surface polymerization (1)
- Organic Chemistry (1)
- Oxygen low-pressure plasma treatment of polymers (1)
- PCA (1)
- PET (1)
- Partial least square discriminant analysis (PLS-DA) (1)
- Peel strength (1)
- Pentafluoropyridine (1)
- Phenolic acid (1)
- Phenolic compounds (1)
- Phenyleneethynylenes (1)
- Phosphonate esters (1)
- Photoligation (1)
- Photooxidation (1)
- Photoswitchable (1)
- Plasma (1)
- Plasma polymers with functional groups (1)
- Pollen grains (1)
- Pollenkörner (1)
- Poly(ether-phosphoramide)s sulfides (1)
- Poly(ethylene glycol) (1)
- Poly(ethylene terephthalate) (1)
- Poly(lactide) (1)
- Polyaddition (1)
- Polycaprolactone (1)
- Polycarbonate-co-dimethylsiloxane copolymer (1)
- Polycondensations (1)
- Polyelectrolytes (1)
- Polyethylene (1)
- Polyethylene oxide (1)
- Polyforamidine (1)
- Polykondensation (1)
- Polylaktid (1)
- Polylaktide (1)
- Polymer MALDI (1)
- Polymer blends (1)
- Polymer chromatography (1)
- Polymer film (1)
- Polymer mass spectrometry (1)
- Polymer reference materials (1)
- Polymerization mechanisms (1)
- Polymers and Plastics (1)
- Polyoxometalates (1)
- Polypropylene (1)
- Polysarcosine (1)
- Polyurethan (1)
- Principal component analysis (PCA) (1)
- Quantification (1)
- ROMP (1)
- Raman (1)
- Renewable resources (1)
- Reversible addition/fragmentation chain transfer (RAFT) (1)
- Ring opening polymerization (ROP) (1)
- Ring-opening Polymerisation (1)
- Ring-opening polymerizations (1)
- Salicylate (1)
- Sample loss (1)
- Self-assembly (1)
- Semi-interpenetrating networks (1)
- Silica gel modification (1)
- Size exclusion chromatography (1)
- Size exclusion chromatography (SEC) (1)
- Size-exclusion chromatography (1)
- Sn catalysts (1)
- Soft ionization mass spectrometry (ESI, MALDI) (1)
- Software (1)
- Solvent-free (1)
- Sonoga (1)
- Sorption isotherm (1)
- Sorption mechanism (1)
- Spacers (1)
- Speciation (1)
- Spirocyclic (1)
- Stereocomplex (1)
- Succinic acid (1)
- Sulfobetaines (1)
- Supramolecular chemistry (1)
- Surface analysis (1)
- Surface coating (1)
- Tandem MS (1)
- Target plate material (1)
- Telechelic polyesters (1)
- Thermo-desorption (1)
- Thermochemistry (1)
- Thin polymer layers (1)
- Time of flight (1)
- Tin(II)octanoate (1)
- Toxicity (1)
- Toxicology (1)
- Triazenes (1)
- Two-dimensional off-line coupling (1)
- Two-dimensional-liquid chromatography (2D-LC) (1)
- UPLC (1)
- UV (1)
- UV degradation (1)
- UV radiation (1)
- Ultraschallfalle (1)
- Universal calibration (1)
- Vacuum ionization (1)
- WMRIF (1)
- Water-soluble polymers (1)
- X-ray photoelectron spectroscopy (1)
- Zinc catalyst (1)
- Zyklen (1)
- a2 + b3 polycondensation (1)
- cyclization (1)
- dispersity (1)
- mass spectra (1)
- mass spectrometry (1)
- polycondensation (1)
- polyesters (1)
- polyionic liquids (1)
- r.f. pulsed plasma (1)
- reversible addition fragmentation chain transfer (RAFT) polymerization (1)
- ring-expansion polymerization (1)
- surface modification (1)
Organisationseinheit der BAM
- 6 Materialchemie (86)
- 6.3 Strukturanalytik (86)
- 1 Analytische Chemie; Referenzmaterialien (5)
- 1.2 Biophotonik (2)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
- 6.6 Physik und chemische Analytik der Polymere (2)
- 7 Bauwerkssicherheit (2)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (2)
- 1.0 Abteilungsleitung und andere (1)
- 1.3 Instrumentelle Analytik (1)
Eingeladener Vortrag
- nein (39)
The structure and composition of polycarbonate polydimethylsiloxane copolymer (PC-co-PDMS) was investigated by applying various analytical approaches including chromatographic separation methods, spectrometric, and spectroscopic detection techniques. In particular, size exclusion chromatography (SEC) and liquid adsorption chromatography operating at different conditions (e.g. using gradient solvent systems) were used to achieve separations according to molar mass and functionality distribution. The coupling of both techniques resulted in fingerprint two-dimensional plots, which could be used to easily compare different copolymer batches. Matrix-assisted laser desorption/ionization-time-of-flight (MALDI-TOF) mass spectrometry was applied for structural investigations. The different ionization behavior of both comonomers, however, strongly limited the applicability of this technique. In contrast to that, Fourier-transform Infrared (FTIR) spectroscopy could be used to quantify the amount of PDMS in the copolymer at different points in the chromatogram. The resulting methodology was capable of distinguishing PC-co-PDMS copolymer from PC homopolymer chains present in the material.
L-lactide was polymerized in bulk at 120, 140, 160 and 180°C with neat tin(II) 2-ethylhexanoate (SnOct2) as catalyst. At 180°C the Lac/Cat ratio was varied from 25/1 up to 8 000/1 and at 160°C from 25/1 up to 6 000/1. The vast majority of the resulting polylactides consist of cycles in combination with a small fraction of linear chains having one octanoate and one COOH end group. The linear chains almost vanished at high Lac/Cat ratios, as evidenced by MALDI-TOF mass spectrometry and measurements of intrinsic viscosities and dn/dc values. At Lac/Cat ratios <1000/1 the number average molar masses (Mn) are far higher than expected for stoichiometic initiation, and above 400/1 the molar masses vary relatively little with the Lac/Cat ratio. At 180° slight discoloration even at short times and degradation of the molar masses were observed, but at 160°C or below colorless products with weight average molar masses (Mw) up to 310 000 g mol-1 were obtained. The formation of high molar mass cyclic polylactides is explained by a ROPPOC (Ring-Opening Polymerizatiom with simultaneous Polycondensation) mechanism with intermediate formation of linear chains having one Sn-O-CH end group and one mixed anhydride end group. Additional experiments with tin(II)acetate as catalyst confirm this interpretation. These findings together with the detection of several transesterification mechanisms confirm previous critique of the Jacobson-Stockmayer theory.
A new concept called “Ring-Opening Polymerization (ROP) combined with simultaneous POlyCondensation” (ROPPOC) is presented and discussed. This synthetic strategy is based on the intermediate formation of chains having two end groups that can react with each other. The ROPPOC syntheses are subdivided into three groups according to the nature of the chain ends: two ionic end groups, one ionic and one covalent chain end and a combination of two reactive covalent end groups may be involved, depending on the catalyst. The usefulness for the preparation of cyclic polymers is discussed with a review of numerous previously published examples. These examples concern to following classes of cyclic polymers: polypeptides, polyamides, polyesters, including polycarbonates, and cyclic polysiloxanes. It is demonstrated, that the results of certain ROPPOC syntheses are in contradiction to the Jacobson-Stockmayer theory. Finally, the usefulness of ROPPOCs for the detection of polydisperse catenanes is discussed.
In addition to molar mass distribution (MMD) synthetic polymers often exhibit an additional chemical heterogeneity distribution, expressed by different end groups and other structural variations (e.g. tacticity, copolymer composition etc.). Ionization in MALDI MS is always strongly affected by such chemical properties. For example, the abundance of cyclics in MALDI TOF mass spectra is frequently reported to greatly exceed that of linears. Thus, the MALDI ionization behavior of various neat end-capped linear poly(L-lactide)s and one cyclic poly(L-lactide) was investigated and compared with that of blends of both structures. Moreover, the influence of the cationizing salt was investigated too.
Neat compounds and various blends of cyclic and linear species were prepared and studied using two MALDI TOF mass spectrometers under identical conditions with regard to sample preparation and instrumental conditions, except for the laser power and the salt used for cationization. Polymer samples were additionally characterized by NMR and SEC.
The steady increase of the laser intensity caused an exponential increase of the peak intensities of both linear and cyclic polylactides.The response of linear polylactides (in the investigated molecular mass range), whether as neat polymer or in blends with other linear polylactides was almost similar. This clearly supports our assumption that ionization in MALDI is probably unaffected by the end group structure.The variation of the laser power shows only little effect on the intensity ratio of linear-to linear and cyclic-to-linear polylactides in blends. Whereas neat linear polylactides at all laser intensities have a significantly higher abundance than neat cyclics, in mixtures of both an overestimation of cyclic species in MALDI TOF mass spectra of polylactides was found. However, this is far less distinct than frequently reported for other polymers.Concluding, peak suppression of linear polymers in mixtures of both architectures can be excluded, which also means, that polylactides showing only peaks of cyclic compounds in their MALDI - TOF mass spectra do not contain a significant fraction of linear analogues.
Our study is the first systematic comparison of the MALDI ionization of neat and blended cyclic and linear polylactides.
The preparation and characterization of poly(ionic liquid)s (PILs) bearing a polystyrene backbone via reversible addition fragmentation chain transfer (RAFT) polymerization and their photolithographic patterning on silicon wafers is reported. The controlled radical polymerization of the styrenic ionic liquid (IL) monomers ([BVBIM]X, X = Cl− or Tf2N−) by RAFT polymerization is investigated in detail. We provide a general synthetic tool to access this class of PILs with controlled molecular weight and relatively narrow molecular weight distribution (2000 g mol−1 ≤ Mn ≤ 10 000 g mol−1 with dispersities between 1.4 and 1.3 for p([BVBIM]Cl); 2100 g mol−1 ≤ MP ≤ 14 000 g mol−1 for p([BVBIM]Tf2N)). More importantly, we provide an in-depth characterization of the PILs and demonstrate a detailed mass spectrometric analysis via matrix-assisted laser desorption ionization (MALDI) as well as – for the first time for PILs – electrospray ionization mass spectrometry (ESI-MS). Importantly, p([BVBIM]Cl) and p([DMVBIM]Tf2N) were photochemically patterned on silicon wafers. Therefore, a RAFT agent carrying a photoactive group based on ortho-quinodimethane chemistry – more precisely photoenol chemistry – was photochemically linked for subsequent controlled radical polymerization of [BVBIM]Cl and [DMVBIM]Tf2N. The successful spatially-resolved photografting is evidenced by surface-sensitive characterization methods such as X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The presented method allows for the functionalization of diverse surfaces with poly(ionic liquid)s.
Trimesoyl chloride is polycondensed with various alpha,omega'-alkanediols in dichloromethane at different concentrations using equifunctional feed ratios. As evidenced by MALDI-TOF (matrix assisted laser desorption/ionization-time of flight) mass spectrometry the soluble reaction products mainly consist of perfect multicyclic oligomers and polymers. The solphase extracted from the gels also consists of perfect multicycles. SEC (size exclusion chromatography) measurements show that both soluble reaction products and extracted solphases also contain a high molar mass fraction of perfect and nonperfect multicycles extending up to masses beyond 10 5 g mol-1. When the polycondensation is stopped after a few minutes perfect multicycles are already detectable in the reaction mixture along with functional (multi)cyclic oligomers. These results prove that at initial monomer concentrations < 0.2 mol L-1 networks and large multicyclic polymers are synthesized from functional cyclic oligomers formed in early stages of the polycondensation and not from hyperbranched polymers. This interpretation is presented as 'egg-first theory' and compared with the 'hen-first theory' of Stockmayer and Flory.
The analytical utility of a new and simple to use ionization method, matrix-assisted ionization (MAI), coupled with ion mobility spectrometry (IMS) and mass spectrometry (MS) is used to characterize a 2-armed europium(III)-containing poly(ethylene glycol) (Eu-PEG) complex directly from a crude sample. MAI was used with the matrix 1,2-dicyanobenzene, which affords low chemical background relative to matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI). MAI provides high ion abundance of desired products in comparison to ESI and MALDI. Inductively coupled plasma-MS measurements were used to estimate a maximum of 10% of the crude sample by mass was the 2-arm Eu-PEG complex, supporting evidence of selective ionization of Eu-PEG complexes using the new MAI matrix, 1,2-dicyanobenzene. Multiply charged ions formed in MAI enhance the IMS gas-phase separation, especially relative to the singly charged ions observed with MALDI. Individual components are cleanly separated and readily identified, allowing characterization of the 2-arm Eu-PEG conjugate from a mixture of the 1-arm Eu-PEG complex and unreacted starting materials. Size-exclusion chromatography, liquid chromatography at critical conditions, MALDI-MS, ESI-MS, and ESI-IMS-MS had difficulties with this analysis, or failed.
Polysarcosine (M-n = 3650-20 000 g mol(-1), D similar to 1.1) was synthesized from the air and moisture stable N-phenoxycarbonyl-N-methylglycine. Polymerization was achieved by in situ transformation of the urethane precursor into the corresponding N-methylglycine-N-carboxyanhydride, when in the presence of a non-nucleophilic tertiary amine base and a primary amine initiator.
Numerous new tin catalysts that enable the synthesis of cyclic polylactides with broad variation in their molecular mass were recently developed. The abundance of cyclics in matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectra is, however, frequently reported to greatly exceed that of linears. Thus, the MALDI ionization behavior of various end-capped linear poly(L-lactide)s and one cyclic poly(L-lactide) was investigated and compared.
Neat compounds and various blends of cyclic and linear species were prepared and studied under identical conditions with regard to sample preparation and instrumental condition, except for the laser power. For this purpose, two different MALDI-TOF mass spectrometers were applied.
Our results reveal that cyclics indeed show a slightly better ionization in MALDI, although their ionization as a neat compound seems to be less effective than that of linear polylactides. The ionization of most linear polylactides investigated does not depend on the end group structure. However, linear polylactides containing 12-bromododecyl end groups reveal an unexpected saturation effect that is not caused by fragmentation of the polymer or the end group, or by electronic saturation of the detector digitizer. Furthermore, polylactides with a 2-bromoethyl end group did not show such a saturation effect.
An overestimation of cyclic species in MALDI-TOF mass spectra of poly(L-lactide)s must be considered, but the commonly assumed peak suppression of linear polymers in mixtures of both structures can be excluded.
Cyclic poly(L-lactide)s were prepared by ring-opening polymerization combined with simultaneous polycondensation (ROPPOC) in bulk at 160 ° with dibutyltin bis(4-cyanophenoxide) as catalyst. It is demonstrated by MALDI TOF mass spectrometry and 1H NMR end group analyses that cycles are formed by endto-end cyclization in addition to “back-biting” transesterification. Formation of high molar mass cyclic poly L-lactide)s by means of several more reactive ROPPOC catalysts presented previously and in new experiments is discussed. These experimental results, together with theoretical arguments, prove that part of the Jacobson–Stockmayer theory is wrong. The critical monomer concentration, above which end-toend cyclization is seemingly impossible, does not exist and reversible like irreversible polycondensations can theoretically proceed up to 100% conversion, so that finally all reaction products will necessarily adopt a cyclic architecture.
Ring–Ring Equilibration in Solid, Even-Numbered Cyclic Poly(l-lactide)s and their Stereocomplexes
(2020)
Even-numbered cyclic poly(d-lactide) and poly(l-lactide) are prepared by ringexpansion polymerization. The cyclic pol(l-lactide) is annealed either at 120 or at 160 °C for several days. The progress of transesterification in the solid state is monitored by the formation of odd-numbered cycles via matrix-assisted laser desorption/ionization-time of flight mass spectrometry. The changes of the crystallinity are monitored by differential scanning calorimetry, wideand small-angle x-ray scattering (WAXS and SAXS) measurements. Despite total even-odd equilibration at 160 °C, the crystallinity of poly(l-lactide) is not reduced. Furthermore, the crystallinity of the stereocomplexes of both cyclic polylactides do not decrease or vanish, as expected, when a blocky or random stereosequence is formed by transesterification. This conclusion is confirmed by 13C NMR spectroscopy. These measurements demonstrate that transesterification is a ring–ring equilibration involving the loops on the surfaces of the lamellar crystallites thereby improving crystallinity and 3D packing of crystallites without significant broadening of the molecular weight distribution.
Matrix‐assisted ionization (MAI) mass spectrometry does not require voltages, a laser beam, or added heat to initiate ionization, but it is strongly dependent on the choice of matrix and the vacuum conditions. High charge state distributions of nonvolatile analyte ions produced by MAI suggest that the ionization mechanism may be similar to that of electrospray ionization (ESI), but different from matrix‐assisted laser desorption/ionization (MALDI). While significant information is available for MAI using mass spectrometers operating at atmospheric and intermediate pressure, little is known about the mechanism at high vacuum.
Eleven MAI matrices were studied on a high‐vacuum time‐of‐flight (TOF) mass spectrometer using a 266 nm pulsed laser beam under otherwise typical MALDI conditions. Detailed comparisons with the commonly used MALDI matrices and theoretical prediction were made for 3‐nitrobenzonitrile (3‐NBN), which is the only MAI matrix that works well in high vacuum when irradiated with a laser.
Screening of MAI matrices with good absorption at 266 nm but with various degrees of volatility and laser energies suggests that volatility and absorption at the laser wavelength may be necessary, but not sufficient, criteria to explain the formation of multiply charged analyte ions. 3‐NBN produces intact, highly charged ions of nonvolatile analytes in high‐vacuum TOF with the use of a laser, demonstrating that ESI‐like ions can be produced in high vacuum. Theoretical calculations and mass spectra suggest that thermally induced proton transfer, which is the major ionization mechanism in MALDI, is not important with the 3‐NBN matrix at 266 nm laser wavelength. 3‐NBN:analyte crystal morphology is, however, important in ion generation in high vacuum.
The 3‐NBN MAI matrix produces intact, highly charged ions of nonvolatile compounds in high‐vacuum TOF mass spectrometers with the aid of ablation and/or heating by laser irradiation, and shows a different ionization mechanism from that of typical MALDI matrices.
SnOct 2-Catalyzed Syntheses of Cyclic Poly (l-lactide) s with Catechol as Low-Toxic Co-catalyst
(2019)
Polymerizations of l-lactide in bulk at 160 or 180 °C were performed with 1/1 mixtures of catechol (CA) or 4-tert-butylcatechol (BuCA) and tin(II)-2-ethylhexanoate (SnOct2) as catalysts and a variation of the Lac/Cat ratio. Weight average molar masses (Mw) up to 170,000 g mol−1 were obtained with CA and up to 120,000 g mol−1 with BuCA. The cyclic structure of the resulting poly(l-lactide)s was proven by MALDI-TOF mass spectrometry and by comparison of their hydrodynamic volumes with those of commercial linear poly(l-lactide)s. The predominance of even-numbered cycles increased with lower temperatures and shorter polymerization times. This fnding indicates that the cyclic architecture is the results of a ring-expansion polymerization mechanism. Addition of silylated BuCA as co-catalyst was less favorable than addition of free BuCA.
L-Lactide was polymerized in bulk with tin(II)2-ethylhexanoate SnOct2) as catalyst and salicylic acid as cocatalyst. The Lac/Cat ratio, Cocat/Cat ratio, temperature and time were varied. Increasing Cocat/Cat ratios reduced both,polymerization rate and molecular weight. However,under optimized conditions high molar mass (Mw up to 178,000), colorless, cyclic polylactides were formed in a short time. A few polymerizations performed at 160 and 180°C with the combination of SnOct2 and silylated salicylic acid gave similar results. Neat tin II) salicylate was prepared from SnOct2 and used for REPs of L-lactide in bulk, but the results were not better than those obtained from combinations of SnOct2 and salicylic acid. Furthermore, dibutyltin salicylate was synthesized and used as catalyst for polymerizations of L-lactide in bulk at temperatures varying from 102 to 160°C. Cyclic polylactides with Mw’s up to 40,000 were the main reaction products. At 100–102°C a predominance of odd-numbered cycles was found proving a REP mechanism.
The analysis of pollen chemical composition is important to many fields, including agriculture, plant physiology, ecology, allergology, and climate studies. Here, the potential of a combination of different spectroscopic and spectrometric methods regarding the characterization of small biochemical differences between pollen samples was evaluated using multivariate statistical approaches. Pollen samples, collected from three populations of the grass Poa alpina, were analyzed using Fourier-transform infrared (FTIR) spectroscopy, Raman spectroscopy, surface enhanced Raman scattering (SERS), and matrix assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS). The variation in the sample set can be described in a hierarchical framework comprising three populations of the same grass species and four different growth conditions of the parent plants for each of the populations. Therefore, the data set can work here as a model system to evaluate the classification and characterization ability of the different spectroscopic and spectrometric methods. ANOVA Simultaneous Component Analysis (ASCA) was applied to achieve a separation of different sources of variance in the complex sample set. Since the chosen methods and sample preparations probe different parts and/or molecular constituents of the pollen grains, complementary information about the chemical composition of the pollen can be obtained. By using consensus principal component analysis (CPCA), data from the different methods are linked together. This enables an investigation of the underlying global information, since complementary chemical data are combined. The molecular information from four spectroscopies was combined with phenotypical information gathered from the parent plants, thereby helping to potentially link pollen chemistry to other biotic and abiotic parameters.
Since its introduction mass spectrometric techniques like Matrix-assisted Laser Desorption/ionization (MALDI) and Electrospray Ionization (ESI) have become indispensable for synthetic polymer analyses. Ideally, various polymer properties (monomer structure, masses, mass distribution, end groups) can be determined simultaneously. However, in real life these experiments are always affected by important structural parameters and instrumental limitations.
A short introduction focussing on latest findings with respect to ionisation principles and mechanisms will be given. Recent results from our group will be presented and efforts to avoid common drawbacks of polymer mass spectrometry will be discussed. In this regard, MALDI - Imaging mass spectrometry and the 2D hyphenation of MS with different chromatographic separation techniques were especially useful, since they can provide additional information and reduce the complexity of polymer analyses.
A new kind of high melting (HTm) pol(L-lactide) was discovered when cyclic poly(L-lactide)s were prepared by ring-expansion polymerization with cyclic tin catalysts at 130–160 °C in bulk. By DSC measurements with 10 K min−1 melting temperatures (Tm) in the range of 190–196 °C were found. The WAXS and SAXS measurements evidenced that not a new crystal lattice but a well-ordered morphology and a higher perfection of the crystallites are responsible for the high Tm values and high crystallinities. Under identical reaction conditions SnOct2-catalyzed and alcohol-initiated ROPs do not yield these crystallites.
Furthermore, it was found that the standard crystallites are kinetically favored upon rapid crystallization, whereas the high melting form of poly(L-lactide) is thermodynamically more stable.
Synthesis of cyclic poly(l-lactide) catalyzed by Bismuth salicylates-A combination of two drugs
(2019)
l‐lactide was polymerized in bulk at 160 or 180°C with mixtures of bismuth subsalicylate (BiSub) and salicylic (SA) as catalysts. The SA/Bi ratio and the monomer/Bi ratio were varied. The highest molecular weights (weight average, Mw) were achieved at a SA/Bi ratio of 1/1 (Mw up to 92 000 g mol−1). l‐Lactide was also polymerized with combinations of BiSub and silylated SA, and Mw values up to 120 000 g mol−1 were achieved at 180°C. MALDI‐TOF mass spectrometry and Mark‐Houwink‐Sakurada measurements proved that under optimized reaction conditions the resulting polylactides consist of cycles.
Polyether and -ester urethanes (PU) were exposed to artificial weathering at 40 °C and artificial UV radiation in a weathering chamber. In 3 parallel exposures, humidity was varied between dry, humid, and wet conditions. Material alteration was investigated by various analytical techniques like size exclusion chromatography
(SEC), liquid chromatography-infrared spectroscopy (LC-FTIR), thermal-desorption gas chromatography-mass spectrometry (TD-GC-MS), fluorescence mapping and dynamic mechanical analysis (DMA). Our results show that depending on the weathering conditions, different degradation effects can be observed. By means of SEC an initial strong decrease of the molar masses and a broadening of the mass distributions was found. After a material dependent time span this was followed by a plateau where molar mass changes were less significant. A minor moisture-dependent degradation effect was only found for polyester PU. Fluorescence measurements on two materials revealed an increase in the luminescence intensity upon weathering process reaching a saturation level after about 500 h. The changes in the optical properties observed after different exposure conditions and times were very similar. The TD-GC-MS data showed the fate of the stabilizers and antioxidant in the course of weathering. LC-FTIR measurements revealed a change in peak intensities and the ratio of urethane and carbonyl bands.
Exceptional ion mobility spectrometry mass spectrometry (IMS-MS) developments by von Helden, Jarrold, and Clemmer provided technology that gives a view of chemical/biological compositions previously not achievable. The ionization method of choice used with IMS-MS has been electrospray ionization (ESI). In this Special issue contribution, we focus on fundamentals of heretofore unprecedented means for transferring volatile and nonvolatile compounds into gas-phase ions singly and multiply charged. These newer ionization processes frequently lead to different selectivity relative to ESI and, together with IMS-MS, may provide a more comprehensive view of chemical compositions directly from their original Environment such as surfaces, e.g., tissue. Similarities of results using solvent- and matrix-assisted ionization are highlighted, as are differences between ESI and the inlet ionization methods, especially with mixtures such as bacterial extracts. Selectivity using different matrices is discussed, as are results which add to our fundamental knowledge of inlet ionization as well as pose additional avenues for inquiry. IMS-MS provides an opportunity for comparison studies relative to ESI and will prove valuable using the new ionization technologies for direct analyses. Our hypothesis is that some ESI-IMS-MS applications will be replaced by the new ionization processes and by understanding mechanistic aspects to aid enhanced source and method developments this will be hastened.