Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (39)
- Beitrag zu einem Tagungsband (16)
- Posterpräsentation (13)
- Zeitschriftenartikel (9)
- Beitrag zu einem Sammelband (9)
- Buchkapitel (2)
Referierte Publikation
- nein (88) (entfernen)
Schlagworte
- MALDI-TOF MS (7)
- MALDI (5)
- Mass spectrometry (4)
- Polylactide (4)
- Ionization (2)
- MALDI TOF MS (2)
- Pollen (2)
- Polymers (2)
- Ring-opening polymerization (2)
- Transesterification (2)
- Abbauverhalten (1)
- Adhesion promoting interlayers (1)
- Bewitterung (1)
- Bioabbaubare Polymere (1)
- Biobased (1)
- Biobased polymers (1)
- Carbon capture (1)
- Catalyst (1)
- Catalysts (1)
- Chemical conversion of functional groups (1)
- Chromatography (1)
- Climate change (1)
- Conductive carbon tape (1)
- Copolymers (1)
- Coupling techniques (1)
- Crystallinity (1)
- Cyclic (1)
- Depollution (1)
- Desorption (1)
- ESI (1)
- ESI-TOF MS (1)
- Electrospray ionization (1)
- Equilibration (1)
- Feuchte (1)
- Field flow fractionation (1)
- HPLC (1)
- Hyperbranched polyesters (1)
- ICP-MS (1)
- Imaging techniques (1)
- Isotope dilution analysis (1)
- Klassifizierung (1)
- Linear (1)
- Liquid adsorption chromatography (1)
- Lubricant (1)
- MALDI Imaging (1)
- MALDI-TOF Mass Spectrometry (1)
- MALDI-TOF Massenspektrometrie (1)
- MALDI-ToF MS (1)
- Matrix-assisted laser desorption/ionization (1)
- Metal-polymer interactions (1)
- Metal-polymer systems (1)
- Micro manufacturing (1)
- Multiphysics simulations (1)
- Multivariate Analyse (1)
- Multivariate statistics (1)
- Nanoparticles separation asymetrical flow field flow fractionation (1)
- Nässe (1)
- Oxygen low-pressure plasma treatment of polymers (1)
- Peel strength (1)
- Plasma modification (1)
- Plasma polymers with functional groups (1)
- Pollenkörner (1)
- Poly(lactide) (1)
- Polyethylene (1)
- Polylactides (1)
- Polylaktid (1)
- Polylaktide (1)
- Polymer (1)
- Polymer chromatography (1)
- Polymer mass spectrometry (1)
- Polymere (1)
- Polymerisation (1)
- Polypropylene (1)
- Polyurethan (1)
- Polyurethane (1)
- Principal component analysis (1)
- Ring-expansion polymerization (1)
- Sample pretreatment (1)
- Silver nanoparticles (1)
- Spacers (1)
- Surface analysis (1)
- TPU (1)
- Tandem MS (1)
- Time of flight (1)
- Tin acetates (1)
- Toxicology (1)
- UV (1)
- WMRIF (1)
- Zyklen (1)
- r.f. pulsed plasma (1)
Organisationseinheit der BAM
- 6 Materialchemie (12)
- 6.3 Strukturanalytik (12)
Eingeladener Vortrag
- nein (39)
Hyphenated techniques
(2012)
Polymeroberflächenfunktionalisierungen im gepulsten Plasma mit nachfolgender chemischer Behandlung
(2000)
Characterization of randomly branched polymers utilizing liquid chromatography and mass spectrometry
(2014)
Branching in polymers is an important way to modify the materials properties, however the characterization of random branching in polymeric materials is a challenge in polymer analysis. In this work, liquid adsorption chromatography methods are developed for a commercially available hyperbranched polyester (Boltorn™). This Chromatographie techniques was then coupled to offline MALDI-TOF MS analysis, a first in the analysis of randomly branched polymers. The coupling of these two techniques provides superior MALDI-TOF spectra, enabling the easy identification of structural subdistributons based on theoretical molecular weight. Detailed analysis of the MALDI-TOF spectra shows that these Chromatographie conditions separate cyclic Boltorn polymers (with no core molecule) from non-cyclic polymers (with core molecule), and these are the only two architectures observed. MALDI MS also confirms that the Chromatographie Separation mode is adsorption, but further analysis is needed to determine if there is a Separation by degree of branching.
The catalytic potential of tin(II)acetate, tin(IV)acetate, dibutyltin-bis-acetate and dioctyl tin-bis-acetate was compared based on polymerizations of L-lactide conducted in bulk at 160 or 130°C. With SnAc2 low-Lac/Cat ratios (15/1–50/1) were studied and linear chains having one acetate and one carboxyl end group almost free of cyclics were obtained. Higher monomer/catalyst ratios and lower temperatures favored formation of cycles that reached weight average molecular weights (Mw's) between 100,000 and 2,500,000. SnAc4 yielded mixtures of cycles and linear species under all reaction conditions. Dibutyltin- and dioctyl tin bis-acetate yielded cyclic polylactides under most reaction conditions with Mw's in the range of 20,000–80,000. Ring-opening polymerizations performed with ε-caprolactone showed similar trends, but the formation of COOH-terminated linear chains was significantly more favored compared to analogous experiments with lactide. The reactivity of the acetate catalysts decreased in the following order: SnAc2> SnAc4>Bu2SnAc2~Oct2SnAc2
Twice recrystallized L-lactide was polymerized with a dozen of different tin or bismuth catalysts in bulk at 160°C for 24 h and was annealed at 150°C afterwards. In two cases Tm values above 197.0°C were obtained. The parameters causing a scattering of the DSC data were studied and discussed. The samples prepared with SnCl2, 2,2-dibutyl-2-stanna-1,3-ditholane (DSTL) or cyclic tin(II) bisphenyldioxide (SnBiph) were subject to annealing programs with variation of time and temperatures, revealing that the Tm´s did not increase. However, an increase of Hm was achieved with maximum values in the range of 93-96 J g-1 corresponding to crystallinities off around 90%. Further studies were performed with once recrystallized L-lactide. Again, those samples directly crystallized from the polymerization process showed the highest Tm values. These data were compared with the equilibrium Tm0 and Hm0 data calculated by several research groups for perfect crystallites. A Tm0 of 213+/-2°C and a Hm0 of 106 J g-1 show the best agreement with the experimental data. The consequences of annealing for the thickness growth of crystallites are discussed on the basis of SAXS measurements. Finally, a comparison of cyclic and linear poly L-lactide)s is discussed.
Ring-expansion polymerizations (REPs) catalyzed by two cyclic tin catalysts (2-stanna-1.3-dioxa-4,5,6,7-dibenzazepine [SnBiph] and
2,2-dibutyl-2-stanna-1,3-dithiolane [DSTL]) are performed at 140 °C in bulk.
Small amounts (4 vol%) of chlorobenzene or other solvents are added to
facilitate transesterification reactions (ring–ring equilibration) in the solid poly(l-lactide)s. In the mass range up to m/z 13 000 crystalline PLAs displaying a so-called saw-tooth pattern in the MALDI-TOF mass spectra are obtained indicating the formation of extended-ring crystals. The characteristics of extended-ring crystallites and folded-ring crystallites are discussed. Furthermore, extremely high melting temperatures (Tm’s up to 201.2 °C) and melting enthalpies (𝚫Hm’s up to 106 J g−1)) are found confirming that 𝚫Hm max, the 𝚫Hm of a perfect crystal, is around or above 115 J g−1 in contrast to literature data.
Matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS) is a well-implemented analytical technique for the investigation of complex biological samples. In MS, the sample preparation strategy is decisive for the success of the measurements. Here, sample preparation processes and target materials for the investigation of different pollen grains are compared. A reduced and optimized sample preparation process prior to MALDI-TOF measurement is presented using conductive carbon tape as target. The application of conductive tape yields in enhanced absolute signal intensities and mass spectral pattern information, which leads to a clear separation in subsequent pattern analysis. The results will be used to improve the taxonomic differentiation and identification, and might be useful for the development of a simple routine method to identify pollen based on mass spectrometry.
A reversed phase high performance liquid chromatography coupled to an inductively coupled plasma mass spectrometer (HPLC-ICP-MS) approach in combination with isotope dilution analysis (IDA) for the separation and parallel quantification of nanostructured and ionic silver (Ag) is presented. The main focus of this work was the determination of the ionic Ag concentration. For a sufficient stabilization of the ions without dissolving the nanoparticles (NPs), the eluent had to be initially optimized. The determined Ag ion concentration was in a good agreement with results obtained using ultrafiltration. Further, the mechanism of the NP separation in the HPLC column was investigated. Typical size exclusion effects were found by comparing results from columns with different pore sizes. Since the recovery rates decreased with increasing Ag NP size and large Ag NPs did not elute from the column, additional interactions of the particles with the stationary phase were assumed. Our results reveal that the presented method is not only applicable to Ag NPs, but also to gold and polystyrene NPs. Finally, IDA-HPLC-ICP-MS experiments in single particle mode were performed to determine the particle cut-off size. The comparison with conventional spICP-MS experiments resulted in a similar diameter and particle size distribution.
Einfluss von Feuchte und Nässe auf die Witterungs-induzierte Alterung am Beispiel eines Polyurethans
(2017)
In diesem Beitrag soll der relative Einfluss des Wassers als Feuchte und Nässe unter den Beanspruchungsfaktoren untersucht werden. Die Unterscheidung von Luftfeuchte und Nässe bezüglich ihrer Wirkung ist dabei notwendig, weil die stehende Nässe zusätzliche Extraktionswirkung besitzt und auch die verfügbare Sauerstoffmenge beeinflusst.
Dazu wurde ein Polymer, das im Rahmen des BAM-internen Projektes PolyComp untersucht wird, künstlich bewittert. Hierzu wurde ein Fluoreszenzlampengerät mit UV-A 340 nm Leuchtstoffröhren verwendet, in dessen Probenraum durch zusätzliche Kammern die gleichzeitige Bewitterung unter drei unterschiedlichen Feuchte-Varianten realisiert wurde (bei konstanter Temperatur):
- UV und trocken
- UV und hohe Luftfeuchte
- UV und stehende Nässe
Das gleichzeitige Einwirken der einzelnen Einflussfaktoren kann dabei konkurrierende oder aufeinander folgende chemische Reaktionen und physikalische Prozesse und somit ein anderes Ergebnis bewirken, als wenn sie isoliert nacheinander auf eine Probe eingewirkt hätten.
Über die erwähnten Varianten hinaus kann auch noch der spezifische Einfluss der UV-Strahlung mit untersucht werden, weil die Proben im Bereich ihrer Befestigung verdeckt sind.
Die Methodik und erste Ergebnisse dieser Untersuchung werden präsentiert.