Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (39)
- Beitrag zu einem Tagungsband (16)
- Posterpräsentation (13)
- Zeitschriftenartikel (9)
- Beitrag zu einem Sammelband (9)
- Buchkapitel (2)
Referierte Publikation
- nein (88) (entfernen)
Schlagworte
- MALDI-TOF MS (7)
- MALDI (5)
- Mass spectrometry (4)
- Polylactide (4)
- Ionization (2)
- MALDI TOF MS (2)
- Pollen (2)
- Polymers (2)
- Ring-opening polymerization (2)
- Transesterification (2)
- Abbauverhalten (1)
- Adhesion promoting interlayers (1)
- Bewitterung (1)
- Bioabbaubare Polymere (1)
- Biobased (1)
- Biobased polymers (1)
- Carbon capture (1)
- Catalyst (1)
- Catalysts (1)
- Chemical conversion of functional groups (1)
- Chromatography (1)
- Climate change (1)
- Conductive carbon tape (1)
- Copolymers (1)
- Coupling techniques (1)
- Crystallinity (1)
- Cyclic (1)
- Depollution (1)
- Desorption (1)
- ESI (1)
- ESI-TOF MS (1)
- Electrospray ionization (1)
- Equilibration (1)
- Feuchte (1)
- Field flow fractionation (1)
- HPLC (1)
- Hyperbranched polyesters (1)
- ICP-MS (1)
- Imaging techniques (1)
- Isotope dilution analysis (1)
- Klassifizierung (1)
- Linear (1)
- Liquid adsorption chromatography (1)
- Lubricant (1)
- MALDI Imaging (1)
- MALDI-TOF Mass Spectrometry (1)
- MALDI-TOF Massenspektrometrie (1)
- MALDI-ToF MS (1)
- Matrix-assisted laser desorption/ionization (1)
- Metal-polymer interactions (1)
- Metal-polymer systems (1)
- Micro manufacturing (1)
- Multiphysics simulations (1)
- Multivariate Analyse (1)
- Multivariate statistics (1)
- Nanoparticles separation asymetrical flow field flow fractionation (1)
- Nässe (1)
- Oxygen low-pressure plasma treatment of polymers (1)
- Peel strength (1)
- Plasma modification (1)
- Plasma polymers with functional groups (1)
- Pollenkörner (1)
- Poly(lactide) (1)
- Polyethylene (1)
- Polylactides (1)
- Polylaktid (1)
- Polylaktide (1)
- Polymer (1)
- Polymer chromatography (1)
- Polymer mass spectrometry (1)
- Polymere (1)
- Polymerisation (1)
- Polypropylene (1)
- Polyurethan (1)
- Polyurethane (1)
- Principal component analysis (1)
- Ring-expansion polymerization (1)
- Sample pretreatment (1)
- Silver nanoparticles (1)
- Spacers (1)
- Surface analysis (1)
- TPU (1)
- Tandem MS (1)
- Time of flight (1)
- Tin acetates (1)
- Toxicology (1)
- UV (1)
- WMRIF (1)
- Zyklen (1)
- r.f. pulsed plasma (1)
Organisationseinheit der BAM
- 6 Materialchemie (12)
- 6.3 Strukturanalytik (12)
Eingeladener Vortrag
- nein (39)
^Mass spectrometry of synthetic polymers applications and limitations of the MALDI-TOF technique
(2011)
Ring-expansion polymerizations (REPs) catalyzed by two cyclic tin catalysts (2-stanna-1.3-dioxa-4,5,6,7-dibenzazepine [SnBiph] and
2,2-dibutyl-2-stanna-1,3-dithiolane [DSTL]) are performed at 140 °C in bulk.
Small amounts (4 vol%) of chlorobenzene or other solvents are added to
facilitate transesterification reactions (ring–ring equilibration) in the solid poly(l-lactide)s. In the mass range up to m/z 13 000 crystalline PLAs displaying a so-called saw-tooth pattern in the MALDI-TOF mass spectra are obtained indicating the formation of extended-ring crystals. The characteristics of extended-ring crystallites and folded-ring crystallites are discussed. Furthermore, extremely high melting temperatures (Tm’s up to 201.2 °C) and melting enthalpies (𝚫Hm’s up to 106 J g−1)) are found confirming that 𝚫Hm max, the 𝚫Hm of a perfect crystal, is around or above 115 J g−1 in contrast to literature data.
Characterization of randomly branched polymers utilizing liquid chromatography and mass spectrometry
(2014)
Branching in polymers is an important way to modify the materials properties, however the characterization of random branching in polymeric materials is a challenge in polymer analysis. In this work, liquid adsorption chromatography methods are developed for a commercially available hyperbranched polyester (Boltorn™). This Chromatographie techniques was then coupled to offline MALDI-TOF MS analysis, a first in the analysis of randomly branched polymers. The coupling of these two techniques provides superior MALDI-TOF spectra, enabling the easy identification of structural subdistributons based on theoretical molecular weight. Detailed analysis of the MALDI-TOF spectra shows that these Chromatographie conditions separate cyclic Boltorn polymers (with no core molecule) from non-cyclic polymers (with core molecule), and these are the only two architectures observed. MALDI MS also confirms that the Chromatographie Separation mode is adsorption, but further analysis is needed to determine if there is a Separation by degree of branching.
The performance of a miniaturized channel for the separation of polymer and metal nanoparticles (NP) using Asymmetrical Flow Field-Flow Fractionation (AF4) was investigated and compared with a conventional AF4 system. To develop standard separation methods, experimental parameters like cross flow, gradient profile and injection time were varied and optimized.
Corresponding chromatographic parameters were calculated and compared. Our results indicate that the chromatographic resolution in the miniaturized channel is lower, whereas significantly shorter analyses time and less solvent consumption were obtained. Moreover, the limit of detection (LOD) and limit of quantification (LOQ) obtained from hyphenation with a UV-detector are obviously lower than in a conventional channel, which makes the miniaturized channel interesting for trace analysis.
We will report on a new kind of ring-expansion polymerization (REP) of cyclic esters based of three classes of catalysts.
In contrast to REP described previously these new polymerizations are characterized by a self-extrusion of the catalysts resulting in cyclic homopolyesters as the only reaction product. These REP of L-lactide were performed in bulk at temperatures between 100 and 180°C without racemization. A simplified scheme of a REP catalyzed by BuCa or SnBi is presented below. With meso-lactide temperatures down to 60°C were realized. Depending on catalyst, time and temperature with equal quantities of even and odd-numbered cycles a strong predominance of either even or odd-numbered cycles was found.
In addition to molar mass distribution (MMD) synthetic polymers often exhibit an additional chemical heterogeneity distribution, expressed by different end groups and other structural variations (e.g. tacticity, copolymer composition etc.). Ionization in MALDI MS is always strongly affected by such chemical properties. For example, the abundance of cyclics in MALDI TOF mass spectra is frequently reported to greatly exceed that of linears. Thus, the MALDI ionization behavior of various neat end-capped linear poly(L-lactide)s and one cyclic poly(L-lactide) was investigated and compared with that of blends of both structures. Moreover, the influence of the cationizing salt was investigated too.
Neat compounds and various blends of cyclic and linear species were prepared and studied using two MALDI TOF mass spectrometers under identical conditions with regard to sample preparation and instrumental conditions, except for the laser power and the salt used for cationization. Polymer samples were additionally characterized by NMR and SEC.
The steady increase of the laser intensity caused an exponential increase of the peak intensities of both linear and cyclic polylactides.The response of linear polylactides (in the investigated molecular mass range), whether as neat polymer or in blends with other linear polylactides was almost similar. This clearly supports our assumption that ionization in MALDI is probably unaffected by the end group structure.The variation of the laser power shows only little effect on the intensity ratio of linear-to linear and cyclic-to-linear polylactides in blends. Whereas neat linear polylactides at all laser intensities have a significantly higher abundance than neat cyclics, in mixtures of both an overestimation of cyclic species in MALDI TOF mass spectra of polylactides was found. However, this is far less distinct than frequently reported for other polymers.Concluding, peak suppression of linear polymers in mixtures of both architectures can be excluded, which also means, that polylactides showing only peaks of cyclic compounds in their MALDI - TOF mass spectra do not contain a significant fraction of linear analogues.
Our study is the first systematic comparison of the MALDI ionization of neat and blended cyclic and linear polylactides.
Einfluss von Feuchte und Nässe auf die Witterungs-induzierte Alterung am Beispiel eines Polyurethans
(2017)
In diesem Beitrag soll der relative Einfluss des Wassers als Feuchte und Nässe unter den Beanspruchungsfaktoren untersucht werden. Die Unterscheidung von Luftfeuchte und Nässe bezüglich ihrer Wirkung ist dabei notwendig, weil die stehende Nässe zusätzliche Extraktionswirkung besitzt und auch die verfügbare Sauerstoffmenge beeinflusst.
Dazu wurde ein Polymer, das im Rahmen des BAM-internen Projektes PolyComp untersucht wird, künstlich bewittert. Hierzu wurde ein Fluoreszenzlampengerät mit UV-A 340 nm Leuchtstoffröhren verwendet, in dessen Probenraum durch zusätzliche Kammern die gleichzeitige Bewitterung unter drei unterschiedlichen Feuchte-Varianten realisiert wurde (bei konstanter Temperatur):
- UV und trocken
- UV und hohe Luftfeuchte
- UV und stehende Nässe
Das gleichzeitige Einwirken der einzelnen Einflussfaktoren kann dabei konkurrierende oder aufeinander folgende chemische Reaktionen und physikalische Prozesse und somit ein anderes Ergebnis bewirken, als wenn sie isoliert nacheinander auf eine Probe eingewirkt hätten.
Über die erwähnten Varianten hinaus kann auch noch der spezifische Einfluss der UV-Strahlung mit untersucht werden, weil die Proben im Bereich ihrer Befestigung verdeckt sind.
Die Methodik und erste Ergebnisse dieser Untersuchung werden präsentiert.
Hyphenated techniques
(2012)
MALDI TOF Massenspektrometrie wurde verwendet, um Kristallisationsprozesse in Polyestern (Polylactide, Polyglycolide) zu untersuchen. Dabei konnte gezeigt werden, dass Zyklen und Linearen simultan, aber in unterschiedlichen Kristalliten, kristallisieren. Die dabei ablaufenden Umesterungen (Transesterifizierungen) konnten mit der MALDI TOF Massenspektrometrie nachgewiesen werden. Damit wurde ein völlig neues Anwendungsgebiet dieser MS Methode demonstriert.
MALDI-ToF mass spectrometry for the characterization of biobased polymers suitable for depollution
(2022)
In this work, bio-based polymers were synthesized and designed as polymers phases for adsorption of a variety of pollutants from aqueous solutions. The obtained adsorption results showed that the integration of bio-sourced synthons generate attractive hydrophilicity, and wettability of the resulting adsorbent phase. Such polymers phases enable stronger interactions with the organic and inorganic pollutants in water.
A wide variety of different bio-based polymers structures (e. g. poly(ethersulfones, poly(etherphosphines or poly(etherpyridines) with different functional groups were successfully designed in order to adapt chemical structure to different pollutants type and matrice nature.
In order to characterize and to determine the correlation between polymer structures and nature of interaction with pollutants, different analytical technics (NMR, GPC, ATG, DSC, Mass spectrometry) were successfully used. Amongst them, MALDI TOF mass spectrometry plays a superior role since this technique enables the simultaneous determination of the polymer structure, polymer end groups and molecular weight.
This work focusses on the characterization of synthesized polymers. The chemical structure of the repeating unit, the nature of the end groups, as well as the molecular weight, which are all important for the specific interactions of the polymer with the pollutants were clearly determined and suggestions to improve these interactions by changing the synthetic pathway could be given.
Die MALDI-TOF Massenspektrometrie stellt eine wichtige Methode zur simultanen Bestimmung von Molmassen, Molmassenverteilungen und Endgruppen von synthetischen Polymeren dar. In dem Vortrag wird gezeigt, welche zusätzlichen Informationen über die Art der Polymerisation, der Nebenreaktionen und der Topologie der gebildeten hochmolekularen Polylaktid-Homo- und Copolymere im Verlauf ihrer Synthese erhalten werden können.
Eine neue Art einer Ring-Expansion Polymerization (REP) von zyklischen Polylaktiden mittels neuer Katalysatoren wird präsentiert.
MALDI-TOF Massenspektrometrie und andere analytische Techniken wurden zur Aufklärung des Mechanismus eingesetzt. Dabei zeigte sich, dass im Gegensatz zu anderen REP, ausschließlich zyklische Polymere gebildet wurden. Diese stellen neue Kandidatenmaterialien für zukünftige neue CRM dar.