Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (12)
- Zeitschriftenartikel (10)
- Beitrag zu einem Sammelband (9)
- Beitrag zu einem Tagungsband (8)
- Posterpräsentation (7)
- Buchkapitel (2)
Sprache
- Englisch (48) (entfernen)
Referierte Publikation
- nein (48) (entfernen)
Schlagworte
- MALDI-TOF MS (6)
- MALDI (4)
- Mass spectrometry (4)
- Polylactide (4)
- MALDI TOF MS (3)
- Ionization (2)
- Pollen (2)
- Polyglycolide (2)
- Polymers (2)
- Ring-opening polymerization (2)
Organisationseinheit der BAM
- 6 Materialchemie (10)
- 6.3 Strukturanalytik (10)
Eingeladener Vortrag
- nein (12)
Glycolide was polymerized in bulk by means of four different ROPPOC catalysts: tin(II) 2-ethylhexanoate (SnOct2), dibutyltin bis(pentafluoro-phenoxide) (BuSnOPF),zinc biscaproate (ZnCap), and zinc bis(pentafluoro-phenyl sulfide) (ZnSPF). The temperature was varied between 110 and 180°C and the time between 3 h and 7 days. For the few polyglycolides (PGAs) that were soluble extremely high molecular masses were obtained. The MALDI TOF mass spectra had all a low signal-to-noise ration and displayed the peaks of cyclic PGAs with a“saw-tooth pattern ”indicating formation of extended-ring crystallites in the mass range below m/z 2500. The shape of DSC curves varied considerably with catalyst and reaction conditions, whereas the long-distance values measured by SAXS were small and varied little with the polymeriza-tion conditions.
We will report on a new kind of ring-expansion polymerization (REP) of cyclic esters based of three classes of catalysts.
In contrast to REP described previously these new polymerizations are characterized by a self-extrusion of the catalysts resulting in cyclic homopolyesters as the only reaction product. These REP of L-lactide were performed in bulk at temperatures between 100 and 180°C without racemization. A simplified scheme of a REP catalyzed by BuCa or SnBi is presented below. With meso-lactide temperatures down to 60°C were realized. Depending on catalyst, time and temperature with equal quantities of even and odd-numbered cycles a strong predominance of either even or odd-numbered cycles was found.
In addition to molar mass distribution (MMD) synthetic polymers often exhibit an additional chemical heterogeneity distribution, expressed by different end groups and other structural variations (e.g. tacticity, copolymer composition etc.). Ionization in MALDI MS is always strongly affected by such chemical properties. For example, the abundance of cyclics in MALDI TOF mass spectra is frequently reported to greatly exceed that of linears. Thus, the MALDI ionization behavior of various neat end-capped linear poly(L-lactide)s and one cyclic poly(L-lactide) was investigated and compared with that of blends of both structures. Moreover, the influence of the cationizing salt was investigated too.
Neat compounds and various blends of cyclic and linear species were prepared and studied using two MALDI TOF mass spectrometers under identical conditions with regard to sample preparation and instrumental conditions, except for the laser power and the salt used for cationization. Polymer samples were additionally characterized by NMR and SEC.
The steady increase of the laser intensity caused an exponential increase of the peak intensities of both linear and cyclic polylactides.The response of linear polylactides (in the investigated molecular mass range), whether as neat polymer or in blends with other linear polylactides was almost similar. This clearly supports our assumption that ionization in MALDI is probably unaffected by the end group structure.The variation of the laser power shows only little effect on the intensity ratio of linear-to linear and cyclic-to-linear polylactides in blends. Whereas neat linear polylactides at all laser intensities have a significantly higher abundance than neat cyclics, in mixtures of both an overestimation of cyclic species in MALDI TOF mass spectra of polylactides was found. However, this is far less distinct than frequently reported for other polymers.Concluding, peak suppression of linear polymers in mixtures of both architectures can be excluded, which also means, that polylactides showing only peaks of cyclic compounds in their MALDI - TOF mass spectra do not contain a significant fraction of linear analogues.
Our study is the first systematic comparison of the MALDI ionization of neat and blended cyclic and linear polylactides.
Pollen represent one major cause for human allergic diseases. Currently the characterization and identification of pollen is time-consuming since it mainly relies on the microscopic determination of the genus-specific pollen morphology. A variety of new analytical approaches, like Raman - and fluorescence spectroscopy have been proposed in order to develop fast and reliable pollen identification. Recently matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was initially applied for the rapid investigation of such complex biological samples. Taxonomic differences and relations of single pollen grains could be identified.
Both commercially available lyophilized pollen and fresh pollen acquired from biological samples collected in parks and in the Botanical Garden Berlin in the years 2013-2015 were investigated. The samples were prepared by formic acid extraction in the gas phase and spotted with HCCA matrix. A variety of new approaches, like a newly developed MALDI target with micrometer sample spots sizes, were tested for their suitability. The obtained mass spectral data were investigated by principal component analysis (PCA).
The applicability of MALDI-TOF mass spectrometry for the classification of pollen according to their taxonomic relationships was proven. Specifically, chemical differences in the mass spectra at the levels of plant order, genus and in many cases even of species could be identified. Based on these results, further investigations have been undertaken to optimize the sample preparation for the classification of single pollen grains in mixtures of pollens. A novel MALDI-target design was developed to enhance the phenotypic information of pollens in their mass spectra. The combination of mass spectral patterns and multivariate statistics provide a powerful tool for the investigation of structural correlations within mixtures. The results can be used to improve the reconstruction of taxonomic relations of single species in various mixtures and might be useful for the development of a fast routine method to identify pollen based on mass spectrometry.
Poly(l-lactide)s are synthesized and annealed at 120 °C and changes of the molecular weight distribution (MWD) are monitored by matrix-assited laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. For example, benzyl alcohol+SnOct2 causes equilibration of odd- and even-numbered chains and the final goal of the transesterification is the most probable distribution. The underlying intermolecular transesterification is even observed at 100 and 80 °C in the solid state. However, cyclic tin mercaptide catalysts transform the initial most probable distribution into a MWD with maxima, which display a conspicuous fine structure due to a preferential crystallization of certain ring sizes. The optimum ring sizes for the crystallization are provided by ring-ring equilibration. The gradual formation of a special morphology shifts the melting temperature to values up to 187 °C. Annealing of commercial poly(l-lactide) with a cyclic tin catalyst also yields a distribution of mass peaks with a maximum showing the characteristic fine structure.
Matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS) is a well-implemented analytical technique for the investigation of complex biological samples. In MS, the sample preparation strategy is decisive for the success of the measurements. Here, sample preparation processes and target materials for the investigation of different pollen grains are compared. A reduced and optimized sample preparation process prior to MALDI-TOF measurement is presented using conductive carbon tape as target. The application of conductive tape yields in enhanced absolute signal intensities and mass spectral pattern information, which leads to a clear separation in subsequent pattern analysis. The results will be used to improve the taxonomic differentiation and identification, and might be useful for the development of a simple routine method to identify pollen based on mass spectrometry.