Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (168) (entfernen)
Referierte Publikation
- ja (168) (entfernen)
Schlagworte
- MALDI-TOF MS (55)
- Polylactide (40)
- Cyclization (26)
- MALDI (16)
- Polycondensation (15)
- Ring-opening polymerization (15)
- Polymerization (8)
- MALDI TOF MS (7)
- Crystallization (6)
- Pollen (6)
- Ring-expansion polymerization (6)
- Transesterification (6)
- Catalyst (5)
- Crystalinity (5)
- Isosorbide (5)
- Lactide (5)
- Mass spectrometry (5)
- Polyester (5)
- Polymere (5)
- Polymers (5)
- Catalysts (4)
- Ionization (4)
- MALDI Massenspektrometrie (4)
- MALDI-TOF mass spectrometry (4)
- Polyesters (4)
- Bismuth (3)
- Imaging (3)
- Liquid chromatography (3)
- Polylactides (3)
- ROPPOC (3)
- Ring opening polymerization (3)
- SEC (3)
- Small-angle X-ray scattering (3)
- Adsorption (2)
- Amphiphiles (2)
- Biobased polymers (2)
- Biodegradable (2)
- Blends (2)
- Block copolymers (2)
- Catechol (2)
- Chromatographie (2)
- Coupling methods (2)
- Crosslinking (2)
- Crystals (2)
- Cyclic (2)
- Cyclopolymerization (2)
- Dispersity (2)
- Epsilon-caprolactone (2)
- FTIR (2)
- Field-flow fractionation (2)
- ICP-MS (2)
- Kopplung (2)
- MALDI mass spectrometry (2)
- MALDI-TOF-MS (2)
- MS/MS (2)
- Macrocycles (2)
- Massenspektrometrie (2)
- Multivariate statistics (2)
- Polyglycolide (2)
- Polymer (2)
- Polymerisation (2)
- Polystyrene (2)
- Polyurethane (2)
- Polyurethanes (2)
- Reversible addition fragmentation chain transfer (RAFT) (2)
- Ring-opening Polymerization (2)
- SAXS (2)
- Sample preparation (2)
- Silver nanoparticles (2)
- Synthesis (2)
- Thermal degradation (2)
- Tin catalysts (2)
- 2-oxazoline (1)
- A4F (1)
- AET (1)
- AFM (1)
- Adhesion promotion (1)
- Alternating co-poly(ether pyridine)s (1)
- Amphiphilic polymers (1)
- Annealing (1)
- Application (1)
- Aromatic organic compounds, (1)
- Aromatic pollutants (1)
- Artificial weathering (1)
- Aryl iodides (1)
- Asymmetric flow filed-flow fractionation (1)
- Asymmetrical flow field flow fractionation (AF4) (1)
- Attenuated total reflectance-Fourier transorm infrared spectroscopy (1)
- Biodegradability (1)
- Biodegradable polyesters (1)
- Biopolymers (1)
- Biosourced isosorbide (1)
- Blockcopolymer (1)
- CRM (1)
- Caco-2 cells (1)
- Caesium (1)
- Capillary electrophoresis (1)
- Capillary electrophoresis (CE) (1)
- Carbon fiberepoxy resin laminates (1)
- Carboxyl group (1)
- Catalytic ability (1)
- Cationic ring opening polymerization (1)
- Cationization (1)
- Chain scission (1)
- Chemical reduction of functional groups (1)
- Chromatography (1)
- Classification (1)
- Click chemistry (1)
- Conductive carbon tape (1)
- Conjugated oligomers (1)
- Controlled radical polymerization (1)
- Conversion (1)
- Copolyester (1)
- Copolymer composition (1)
- Copolymer sequence (1)
- Copolymeranalytik (1)
- Copolymerization (1)
- Cotton effect (1)
- Coupling (1)
- Cyclics (1)
- Cyclisation (1)
- Cycloaddition (1)
- Cycloparaphenylenes (1)
- DCTB (1)
- Degradation (1)
- Dendrimers (1)
- Dendrons (1)
- Dried droplet (1)
- Droplet (1)
- Dynamic light scattering (1)
- ESI (1)
- ESI-Massenspektrometrie (1)
- Electron paramagnetic resonance study (1)
- Electrospray (1)
- Electrospray ionization (1)
- Electrospray ionization (ESI) (1)
- Epsilon-Caprolactone (1)
- Epsilon-caprolactone (e-CL) (1)
- Europium (1)
- Foldamers (1)
- Fractionation of polymers (1)
- Fragmentierung (1)
- Friction (1)
- Ft-IR (1)
- Functionalized graphene nanoribbons (1)
- Fundamentals (1)
- Glycodendrimers (1)
- Glycolide (1)
- Gradient chromatography (1)
- Gradient elution (1)
- Gradient elution liquid chromatography (GELC) (1)
- Graphene monomers (1)
- Graphene nanoribbons (1)
- Graphene wires (1)
- Green chemistry (1)
- Hafnium (1)
- Heavy metals (1)
- Hexabenzocoronene (1)
- Hierarchical cluster analysis (1)
- Hierarchical self-assembly (1)
- High performance liquid chromatography (1)
- Host–guest systems (1)
- Humidity (1)
- Hybrid nanoparticles (1)
- Hydrolytic degradation (1)
- Hyphenated techniques (1)
- Imaging MS (1)
- In situ EXAFS (1)
- In situ SAXS/WAXS (1)
- In vitro digestion (1)
- Inductively coupled plasma-mass spectrometry (1)
- Inlet ionization (1)
- Intrinsic viscosity (1)
- Ion mobility (1)
- Ionization mass spectrometry (1)
- Iron oxide nanoparticles (1)
- Irreversible polycondensation (1)
- Isophthalic acid (1)
- Isotope dilution analysis (1)
- Jacobsen-Stockmayer theory (1)
- Kopplungsmethoden (1)
- L-lactide (1)
- LC-MS coupling (1)
- Lactides (1)
- Lacunary Keggin ion (1)
- Lanthanide ions (1)
- Laser-induced redox reactions (1)
- Layer topography (1)
- Lead ions (1)
- Light scattering (LS) (1)
- Liquid adsorption chromatography (1)
- Liquid adsorption chromatography at critical conditions (1)
- Liquid chromatography at critical conditions (1)
- Liquid chromatography under critical conditions (LCCC) (1)
- MALDI Imaging MS (1)
- MALDI TOF Massenspektrometrie (1)
- MALDI TOF mass spectrometry (1)
- MALDI-TOF (1)
- MALDI-TOF MS/MS (1)
- MOF (1)
- Mass Spectrometry (1)
- Mass spectrometry imaging (1)
- Materials Chemistry (1)
- Matrices (1)
- Matrix segregation (1)
- Matrix-assisted ionization ion mobility spectrometry mass spectrometry (1)
- Matrix-assisted laser desorption (1)
- Matrix-assisted laser desorption/ionization (1)
- Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS) (1)
- Matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometry (1)
- Mechanism (1)
- Mechanism of polymerization (1)
- Mega-dalton (1)
- Metal ion complexation (1)
- Metal ion-intradendrimer complexes (1)
- Metal triflates (1)
- Microwave (1)
- Moisture (1)
- Molar mass determination (1)
- Molar mass distribution (1)
- Molecular masses (1)
- Molecular recognition (1)
- Morphology (1)
- Multicyclic polymers (1)
- Multivariate Statistics (1)
- Multivariate analyses (1)
- N-vinyl pyrrolidone (1)
- Nanolithography (1)
- Nanoparticle (1)
- Nanoparticles (1)
- Nanoparticles with same nominal diameter (1)
- Networks (1)
- Oligoazobenzene (1)
- Oligospiroketals (1)
- On-surface polymerization (1)
- Organic Chemistry (1)
- PCA (1)
- PET (1)
- Partial least square discriminant analysis (PLS-DA) (1)
- Pentafluoropyridine (1)
- Phenolic acid (1)
- Phenolic compounds (1)
- Phenyleneethynylenes (1)
- Phosphonate esters (1)
- Photoligation (1)
- Photooxidation (1)
- Photoswitchable (1)
- Plasma (1)
- Plasma modification (1)
- Pollen grains (1)
- Poly(ether-phosphoramide)s sulfides (1)
- Poly(ethylene glycol) (1)
- Poly(ethylene terephthalate) (1)
- Polyaddition (1)
- Polycaprolactone (1)
- Polycarbonate-co-dimethylsiloxane copolymer (1)
- Polycondensations (1)
- Polyelectrolytes (1)
- Polyethylene oxide (1)
- Polyforamidine (1)
- Polykondensation (1)
- Polymer MALDI (1)
- Polymer blends (1)
- Polymer film (1)
- Polymer reference materials (1)
- Polymerization mechanisms (1)
- Polymers and Plastics (1)
- Polyoxometalates (1)
- Polysarcosine (1)
- Principal component analysis (1)
- Principal component analysis (PCA) (1)
- Quantification (1)
- ROMP (1)
- Raman (1)
- Renewable resources (1)
- Reversible addition/fragmentation chain transfer (RAFT) (1)
- Ring opening polymerization (ROP) (1)
- Ring-opening Polymerisation (1)
- Ring-opening polymerizations (1)
- Salicylate (1)
- Sample loss (1)
- Sample pretreatment (1)
- Self-assembly (1)
- Semi-interpenetrating networks (1)
- Silica gel modification (1)
- Size exclusion chromatography (1)
- Size exclusion chromatography (SEC) (1)
- Size-exclusion chromatography (1)
- Sn catalysts (1)
- Soft ionization mass spectrometry (ESI, MALDI) (1)
- Software (1)
- Solvent-free (1)
- Sonoga (1)
- Sorption isotherm (1)
- Sorption mechanism (1)
- Speciation (1)
- Spirocyclic (1)
- Stereocomplex (1)
- Succinic acid (1)
- Sulfobetaines (1)
- Supramolecular chemistry (1)
- Surface coating (1)
- TPU (1)
- Target plate material (1)
- Telechelic polyesters (1)
- Thermo-desorption (1)
- Thermochemistry (1)
- Thin polymer layers (1)
- Tin acetates (1)
- Tin(II)octanoate (1)
- Toxicity (1)
- Triazenes (1)
- Two-dimensional off-line coupling (1)
- Two-dimensional-liquid chromatography (2D-LC) (1)
- UPLC (1)
- UV degradation (1)
- UV radiation (1)
- Ultraschallfalle (1)
- Universal calibration (1)
- Vacuum ionization (1)
- Water-soluble polymers (1)
- X-ray photoelectron spectroscopy (1)
- Zinc catalyst (1)
- a2 + b3 polycondensation (1)
- cyclization (1)
- dispersity (1)
- mass spectra (1)
- mass spectrometry (1)
- polycondensation (1)
- polyesters (1)
- polyionic liquids (1)
- reversible addition fragmentation chain transfer (RAFT) polymerization (1)
- ring-expansion polymerization (1)
- surface modification (1)
Organisationseinheit der BAM
- 6 Materialchemie (73)
- 6.3 Strukturanalytik (73)
- 1 Analytische Chemie; Referenzmaterialien (5)
- 1.2 Biophotonik (2)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
- 6.6 Physik und chemische Analytik der Polymere (2)
- 7 Bauwerkssicherheit (2)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (2)
- 1.0 Abteilungsleitung und andere (1)
- 1.3 Instrumentelle Analytik (1)
Size-exclusion chromatography (SEC) was used to monitor changes of the molecular masses of thermoplastic polyether – and polyester urethane (TPU) exposed to thermal, hydrolytic, and photo-oxidative (UV) Degradation conditions for several days. The thermal treatment was performed at elevated temperatures (100–200 °C) under oxidative (air) as well as non-oxidative (nitrogen) conditions to evaluate the specific influence of oxygen on the degradation. At higher temperatures (≥175 °C) a fast decrease of the molecular masses of both PU accompanied by a high degree of crosslinking was found. At lower temperatures (≤150 °C) the polymers remained widely unaffected by thermal degradation within the investigated degradation interval of up to two weeks. Surprisingly, the influence of oxygen (air) was found to be less distinct. In contrast to that, UV treatment at 25 °C at less than 10% rel. humidity (RH) resulted in a fast crosslinking, whereas the molecular masses of both PU decreased slower than for thermal treatments. The depth of penetration of the UV radiation was estimated using 3D printed PU samples with different thicknesses. Hydrolysis based degradation effects were less significant. Only slight molecular mass changes were detected at temperatures ≤80 °C within a time span of 14 days, while no crosslinking could be measured. Considering the degradation results at the investigated exposure parameters, it could be shown that esterbased PU in general exhibits a significant higher stability compared to ether-based materials.
RATIONALE
A fast and reliable online identification of pollen is not yet available. The identification of pollen is based mainly on the evaluation of morphological data obtained by microscopic methods.
METHODS
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS) was applied to the analysis of extracts and milled pollen samples. The obtained MALDI data were explored for characteristic peak patterns which could be subjected to a multivariate statistical analysis.
RESULTS
Two sample preparation methods are presented, which require only minimal or no chemical extraction of the pollen. MALDI pollen spectra could be recorded showing various peak patterns. A multivariate statistics approach allowed the classification of pollen into clusters indicating similarities and differences between various species.
CONCLUSIONS
These results demonstrate the potential and the reliability of MALDI-TOF MS for the identification and, in combination with multivariate statistics, also for the classification of pollen.
Rationale
The ionization of polystyrenes in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is typically achieved by the use of silver salts. Since silver salts can cause severe problems, such as cluster formation, fragmentation of polymer chains and end group cleavage, their substitution by alkali salts is highly desirable.
Methods
The influence of various cations (Ag+, Cs+ and Rb+) on the MALDI process of polystyrene (PS) mixtures and high mass polystyrenes was examined. The sample preparation was kept as straightforward as possible. Consequently, no recrystallization or other cleaning procedures were applied.
Results
The investigation of a polystyrene mixture showed that higher molecular polystyrenes could be more easily ionized using caesium, rather than rubidium or silver salts. In combination with the use of DCTB as matrix a high-mass polymer analysis could be achieved, which was demonstrated by the detection of a 1.1 MDa PS.
Conclusions
A fast, simple and robust MALDI sample preparation method for the analysis of ultra-high molecular weight polystyrenes based on the use of DCTB and caesium salts has been presented. The suitability of the presented method has been validated by using different mass spectrometers and detectors.
The adhesion of poly(methyl methacrylate) (PMMA) and polystyrene (PS) films, whose surface has been previously structured by dynamic plowing lithography (DPL), has been measured by means of forcedisplacement curves. The different adhesion of modified and unmodified PS leads to the assumption that polymer chains are broken during DPL. After measuring the energy dissipated by the tip during DPL, in order to check that the transferred energy is sufficient to break covalent bonds, the polymer chain scission caused by the lithographic process has been definitely confirmed by size exclusion chromatography measurements of the lithographed films.
A reversed phase high performance liquid chromatography coupled to an inductively coupled Plasma mass spectrometer (HPLC–ICP-MS) approach in combination with isotope dilution analysis (IDA) for the separation and parallel quantification of nanostructured and ionic silver (Ag) is presented. The main Focus of this work was the determination of the ionic Ag concentration. For a sufficient stabilization of the Ions without dissolving the nanoparticles (NPs), the eluent had to be initially optimized. The determined Ag ion concentration was in a good agreement with results obtained using ultrafiltration. Further, the mechanism of the NP separation in the HPLC column was investigated. Typical size exclusion effects were found by comparing results from columns with different pore sizes. Since the recovery rates decreased with increasing Ag NP size and large Ag NPs did not elute from the column, additional interactions of the particles with the stationary phase were assumed. Our results reveal that the presented method is not only applicable to Ag NPs, but also to gold and polystyrene NPs. Finally, IDA-HPLC-ICP-MS experiments in single particle mode were performed to determine the particle cut-off size. The comparison with conventional spICP-MS experiments resulted in a similar diameter and particle size distribution.
In this work, sample losses of silver nanoparticles (Ag NPs) in asymmetrical flow field-flow fractionation (AF4) have been systematically investigated with the main focus on instrumental conditions like focusing and cross-flow parameters as well as sample concentration and buffer composition. Special attention was drawn to the AF4 membrane. For monitoring possible silver depositions on the membrane, imaging laser ablation coupled to inductively coupled plasma mass spectrometry (LA-ICP-MS) was used. Our results show that the sample residue on the membrane was below 0.6% of the total injected amount and therefore could be almost completely avoided at low sample concentrations and optimized conditions. By investigation of the AF4 flows using inductively coupled plasma mass spectrometry (ICP-MS), we found the recovery rate in the detector flow under optimized conditions to be nearly 90%, while the cross-flow, slot-outlet flow and purge flow showed negligible amounts of under 0.5%. The analysis of an aqueous ionic Ag standard solution resulted in recovery rates of over 6% and the ionic Ag content in the sample was found to be nearly 8%. Therefore, we were able to indicate the ionic Ag content as the most important source of sample loss in this study.
Matrix-assisted laser desorption/ionization-timeof-flight (MALDI-TOF) imaging of polystyrenes with various molecular masses was applied to study spatial molecular mass distribution of polymers in sample spots prepared by the 'dried droplet' method. When different solvents and target surfaces were examined, a segregation of single homologous polymers was observed depending upon the evaporation rate of the solvent. For the observed Patterns left by the evaporating droplet, a hypothesis is offered taking into account different hydrodynamic interactions and diffusion.
The results illustrate that spot preparation using the conventionally 'dried droplet' method is prone to artifacts and should be avoided for reliable and reproducible MALDI mass spectrometry experiments with regards to the Determination of molecular masses and mass distributions.
Molecular masses and end groups of polystyrene (PS) formed in a novel container-less polymerization strategy, based on levitated droplets in an acoustic trap, were determined by Gel Permeation Chromatography (GPC) and Matrix-assisted Laser Desorption/Ionization Time of Flight Mass spectrometry (MALDI-TOF MS).