Final report of research activities at BAM concerning large scale fireballs of organic peroxides (OP). New models for OP fireball diameter, duration, height and Surface Emmissive Power (SEP) are proposed and discussed based on a large number of large-scale and small-scale experiments using Di-tert-butylperoxide (DTBP) as a liquid OP and heptane as a liquid hydrocarbon fuel. Finally, CFD simulations are used to predict the fireball parameters: diameter, duration, height and SEP. Also the impact on the German storage regulations for organic peroxides are discussed.
Amuay accident 2012 is one of similar accidents happened in Buncefield (2005), Jaipur and Puerto Rico (2009), respectively. Since experimental reproduction of such accidents is not always possible numerical simulations help a lot to understand the scenarios on qualitative basis. In this work the accident is reproduced with a CFD model which takes into account the heaviness of the gas (LPG), wind and gravity driven spread. The leak was reported to be located near a number of spherical tanks. The ignition source was presumably the running vehicles on a nearby street. A part of the refinery containing the locations of leakage and ignition was considered as computational domain. The road is located at the eastern boarder. The area contains different tanks, whose height was estimated due to a lack of available data. The diameter was extrapolated from the available image data. Further, a grid of walls is located between a number of tanks. The total domain has a size of 750 m x 400 m x 50 m. An unstructured mesh was created using tetrahedral elements with prism layers at the ground to improve mesh quality in the boundary layer. The mesh has a total number of 775 686 cells.
Flame temperature (T), surface emissive power (SEP) of Liquefied Natural Gas (LNG) pool fires (d = 1 m, 6.1 m, 30 m) are investigated by CFD (Computational Fluid Dynamics) simulation and compared with experimental results.
Time averaged flame temperatures of T = 1320 K, T = 1298 K and T = 1281 K are obtained. Surface emissive power (SEP) of 55 kW=m2, 130 kW=m2 and 230 kW=m2 are predicted.
Most of the measurements of temperatures in large pool fires are indirect and present a number of complexities due to the interactions of convection, radiation and soot blockage. In the present work these influences for two organic peroxide [tert-butyl peroxybenzoate (TBPB) and tert-butyl peroxy-2-ethylhexanoate (TBPEH)] pool fires are analysed.
Thermocouple measured temperature in the clear flame zone i.e. combustion zone are found to be 250-400 K lower than from the thermographic measurements. The convective and radiative heat flux contributions from the fire on temperature measurements are discussed. CFD (Computational Fluid Dynamics) simulations have been performed for large pool fires and the predicted time averaged flame temperatures were found to be in qualitative agreement with
measurements due to the stoichiometric combustion model used in the present simulations.
Two-phase CFD (Computational Fluid Dynamics) model for characterising the spill-over/dispersion of peroxy-fuels is presented. The model is independent of type and burning rate of the spilled/dispersed fuel and considers only overflow Reynolds number (Re) to characterise the spill/dispersion behaviour. Additional simulations are performed for LNG (Liquified Natural Gas) dispersion and it is found that the model can be used for different fuels within a defined range of Re. Different scenarios with Re = 100 to 3 × 105 are investigated covering a wide range of mass flow rates, opening sizes and viscosities. Depending on Lower Flammability Limits (LFL) of the fuels spill/dispersion (vapour cloud) diameters (DCFD) and heights (hCFD) are predicted. A generalised correlation between DCFD and Re is established to predict the dispersion occurring at varying scales. The model is validated by: (1) conducting an extensive grid independent study; (2) comparing the results with the existing analytical methods and (3) comparing against the standard field test data on LNG dispersions.