Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (116)
- Zeitschriftenartikel (99)
- Posterpräsentation (25)
- Forschungsbericht (11)
- Beitrag zu einem Sammelband (9)
- Beitrag zu einem Tagungsband (7)
- Buchkapitel (3)
- Sonstiges (2)
- Corrigendum (1)
- Forschungsdatensatz (1)
Schlagworte
- Traceability (35)
- Metrology (33)
- IDMS (19)
- Absolute isotope ratio (18)
- Isotope ratio (17)
- Uncertainty (17)
- CCQM (11)
- Measurement uncertainty (11)
- ICP-MS (10)
- Reference material (10)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (90)
- 1.1 Anorganische Spurenanalytik (90)
- P Präsident (4)
- P.0 Präsident und andere (4)
- 1.3 Instrumentelle Analytik (3)
- 1.4 Prozessanalytik (3)
- 1.6 Anorganische Referenzmaterialien (3)
- S Qualitätsinfrastruktur (3)
- S.1 Qualität im Prüfwesen (3)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
Eingeladener Vortrag
- nein (116)
The present paper describes the contribution of the Institute for Reference Materials and Measurements to the certification of B, Cd, Mg, Pb, Rb, Sr, and U amount contents in a natural water sample, in round 9 of the International Measurement Evaluation Programme (IMEP-9). The analytical procedure to establish the reference values for B, Cd, Mg, Pb, Rb, Sr, and U amount contents was based on isotope dilution inductively coupled plasma-mass spectrometry used as a primary method of measurement. Applying this procedure reference values, traceable to the SI, were obtained for the natural water sample of IMEP-9. For each of the certified amount contents presented here a total uncertainty budget was calculated using the method of propagation of uncertainties according to ISO and EURACHEM guidelines. The measurement procedures, as well as the uncertainty calculations are described for all seven elements mentioned above. In order to keep the whole certification process transparent and so traceable, the preparations of various reagents and materials as well as the sample treatment and blending, the measurements themselves, and finally the data treatment are described in detail. Explanations focus on Pb as a representative example. The total uncertainties (relative) obtained were less than 2% for all investigated elements at amount contents in the pmol/kg up to the high 7mol/kg range, corresponding to low 7g/kg and mg/kg levels.
The present paper describes the certification of the amount content of Cd, Cr and Pb in two different polyethylene materials within the third phase of the Polyethylene Elemental Reference Material (PERM) project. The analytical procedure to establish the reference values for Cd, Cr and Pb amount contents in these materials is based on isotope dilution mass spectrometry used as a primary method of measurement. Cd and Pb were measured with inductively coupled plasma-mass spectrometry and Cr with positive thermal ionization-mass spectrometry. The decomposition of the polymer matrix was carried out using a high pressure asher. Reference values for amount content, traceable to the SI-system, have been obtained for these three elements in both of the polyethylene samples of PERM. For each of the certified amount content values an uncertainty budget was calculated using the method of propagation of uncertainties according to ISO and EURACHEM guidelines. The measurement procedures, as well as the uncertainty calculations, are described for all three elements. In order to keep the whole certification process as transparent as possible, the preparations of various reagents and materials as well as the sample treatment and blending are described in detail. The mass spectrometry measurements and the data treatment are also explained carefully. The various sources of uncertainty present in the procedure are displayed in the uncertainty budgets. The obtained combined uncertainties for the amount content values were less than 2% relative (k=1) for all investigated elements. The amount contents were in the ?mol/kg range, corresponding to mg/kg levels.
Comparative performance study of ICP mass spectrometers by means of U "isotopic measurements"
(2000)
The performance of four commercially available ICPMS instruments of three different types was compared by means of uranium "isotopic measurements". Examined were two quadrupole sector (different generation, different manufacturer), one single detector double focusing magnetic sector and one multiple collector double focusing magnetic sector instruments. The same samples of the IRMM-072 series were used under routine conditions to measure the 233U/235U and the 233U/238U ratios which, in these samples, vary over almost three orders of magnitude from ~ 1 to ~ 2 · 10-3. Within expanded (k = 2) uncertainties, good agreement was observed between the certified values and the data internally corrected for mass-discrimination effects. The magnitude of the evaluated uncertainties was different for each type of instrument. With the multiple collector instrument, expanded uncertainties varied from - 0.04% to- 0.24% for the 233U/235U ratio, and from - 0.08% to - 0.27% for the 233U/238U ratio. They were ~ 1 to 5 times larger with the single detector magnetic sector instrument, and ~ 10 to 25 times larger with both quadrupole sector instruments. With the multiple collector instrument, repeatability of the measurements seemed to be limited by the difficulty of correcting properly for instrumental background, whereas with the single detector magnetic sector instrument the counting statistics was the only limitation (on smallest ratios). Apparent mass-discrimination was clearly found to be larger but more reproducible (and hence easier to correct for) in the case of magnetic sector instruments than for both quadrupole sector instruments. If space charge effects were the main source of mass-discrimination for all instruments, these results are in contradiction with the hypothesis of the size of mass-discrimination decreasing with the acceleration voltage. With the single detector magnetic sector instrument in particular (when operated by changing the ion energy only), our results pointed at more than only one major source of mass-discrimination, with variable size depending on the ratios measured.
A thin-layer reference material for surface and near-surface analytical methods was produced and certified. The surface density of the implanted Sb layer was determined by Rutherford backscattering spectrometry (RBS), instrumental neutron activation analysis (INAA), and inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) equipped with a multi-collector. The isotopic abundances of Sb (121Sb and 123Sb) were determined by multi-collector ICP-MS and INAA. ICP-IDMS measurements are discussed in detail in this paper. All methods produced values traceable to the SI and are accompanied by a complete uncertainty budget. The homogeneity of the material was measured with RBS. From these measurements the standard uncertainty due to possible inhomogeneities was estimated to be less than 0.78% for fractions of the area increments down to 0.75 mm2 in size. Excellent agreement between the results of the three different methods was found. For the surface density of implanted Sb atoms the unweighted mean value of the means of four data sets is 4.8121016 cm-2 with an expanded uncertainty (coverage factor k=2) of 0.0921016 cm-2. For the isotope amount ratio R (121Sb/123Sb) the unweighted mean value of the means of two data sets is 1.435 with an expanded uncertainty (coverage factor k=2) of 0.006.