Filtern
Erscheinungsjahr
- 2013 (21) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (9)
- Vortrag (8)
- Posterpräsentation (2)
- Buchkapitel (1)
- Beitrag zu einem Sammelband (1)
Schlagworte
- XPS (5)
- NEXAFS (4)
- Surface analysis (3)
- Imaging (2)
- SEM (2)
- TEM (2)
- ToF-SIMS (2)
- AES (1)
- Ageing (1)
- Amino groups (1)
Eingeladener Vortrag
- nein (8)
Mechanically interlocked molecules (MIMs) such as rotaxanes and catenanes are capable of mechanical motion on the nanoscale and are therefore promising prototypes for molecular machines in recent nanotechnology. However, most of the existing examples are isotropically distributed in solution, which prohibits concerted movement and with it the generation of macroscopic effects. Thus, arranging them in ordered arrays is of huge interest in recent research. We report the deposition of quite densely packed multilayers of tetralactam macrocycles on gold surfaces by metal-coordinated layer-by-layer self-assembly. Linear dichroism effects in angle-resolved NEXAFS spectra indicate a preferential orientation of the macrocycles. The sequence of the metal ions can be programmed by the use of different transition metal ions at each deposition step. Additionally, reversible on-surface pseudorotaxane formation was successfully realized by repeated uptake and release of axle molecules inside the macrocycles cavities.
Fluorinated Boron-Dipyrromethene (BODIPY) dyes: bright and versatile probes for surface analysis
(2013)
A family of bright boron-dipyrromethene-type fluorophores with a high number of fluorine atoms (F-BODIPYs) has been developed and characterized by X-ray crystallography and optical spectroscopy. The introduction of 3,5-bis(trifluoromethyl)phenyl and pentafluorophenyl moieties significantly enhances the photostability of such dyes, yielding for instance photostable near-infrared (NIR) fluorophores that show emission maxima>750 nm, when the BODIPY's π system is extended with two (dimethylamino)styryl and (dimethylamino)naphthastyryl moieties, or green-emitting BODIPYs with fluorescence quantum yields of unity. When equipped with a suitable group that selectively reacts for instance with amines, F-BODIPYs can be used as potent dual labels for the quantification of primary amino groups on surfaces by X-ray photoelectron spectroscopy (XPS) and fluorescence, two powerful yet complementary tools for the analysis of organic surface functional groups. The advantage of reactive F-BODIPYs is that they allow a fast and non-destructive mapping of the labelled supports with conventional fluorescence scanners and a subsequent quantification of selected areas of the same sample by the potentially traceable XPS technique. The performance is exemplarily shown here for the assessment of the amino group density on SiO2 supports, one of the most common reactive silica supports, in particular, for standard microarray applications.
Nitrogen rich plasma polymer films (L-PPE:N) were prepared by low-pressure RF plasma using a 1:1 mixture of ethylene and ammonia and aged for 345 d in four different ambient conditions: (i) at room temperature (RT) in air; (ii) at RT in nitrogen; (iii) at -20?°C in air and; (iv) at –20 °C in nitrogen. The films were analyzed by X-ray photoelectron spectroscopy (XPS) and by time-of-flight secondary ion mass spectrometry (ToF-SIMS) at various intervals over the duration of the experiment. The ageing of primary amines, NH2, was followed by chemical derivatization with 4-trifluoromethyl benzaldehyde. Storage at –20 °C, mostly independently of ambient atmosphere, slowed down ageing to almost undetectable levels as evaluated by the analytical methods used for this study.
This Technical Report revises ISO/TR 19319:2003 - Surface chemical Analysis-Auger electron spectroscopy and X-ray photoelectron spectroscopy-Determination of lateral resolution, analysis area and sample area viewed by the analyser. The revised Technical Report gives a short introduction to basic models of image formation and introduces functions which characterize the performance of imaging instruments with respect to lateral resolution and sharpness. The determination of lateral resolution by imaging of square-wave gratings and the determination of sharpness by imaging of narrow stripes and straight edges are described in detail. Finally, physical factors affecting lateral resolution, analysis area and sample area viewed by the analyser are discussed.