Organisationseinheit der BAM
Laboratory test results are of vital importance for correctly classifying and labelling chemicals as “hazardous” as defined in the UN Globally Harmonized System (GHS) / EC CLP Regulation or as “dangerous goods” as defined in the UN Recommendations on the Transport of Dangerous Goods. Interlaboratory tests play a decisive role in assessing the reliability of laboratory test results. Interlaboratory tests performed over the last 10 years have examined different laboratory test methods. After analysing the results of these interlaboratory tests, the following conclusions can be drawn:
1. There is a need for improvement and validation for all laboratory test methods examined.
2. To avoid any discrepancy concerning the classification and labelling of chemicals, the use of validated laboratory test methods should be state of the art, with the results accompanied by the measurement uncertainty and (if applicable) the probability of incorrect classification.
This paper addresses the probability of correct/incorrect classification (for example, as dangerous goods) on the basis of the measurement deviation obtained from interlaboratory tests performed by the Centre for quality assurance for testing of dangerous goods and hazardous substances (CEQAT-DGHS) to validate laboratory test methods. This paper outlines typical results (e.g. so-called “Shark profiles” – the probability of incorrect classification as a function of the true value estimated from interlaboratory test data) as well as general conclusions and steps to be taken to guarantee that laboratory test results are fit for purpose and of high quality.
Biocide leaching was investigated for acrylate and vinyl acetate based coatings containing biocides either as liquid formulations or microcapsules. Laboratory and field tests indicate similar relations of results on carbendazim, diuron, terbutryn and OIT from different coatings in laboratory and field experiments. Emissions were higher in EN 16105 laboratory tests than from vertically installed test specimens exposed to weathering, and slower for microencapsulated biocides. Competing processes that cause losses of active substances can occur in both tests, but to a higher degree in field experiments. Emission curves related to runoff water were similar in repeated field experiments. Relative humidity, temperature and global radiation were identified as meteorological factors that affect leaching by complex interaction besides the amount of driving rain.