Ground Penetration Radar (GPR) as a non-destructive (NDT)-method can be applied to obtain detailed information about the inner structure and condition of bridges without damaging the structure.
In this paper the capabilities and limitations of the application of the fast inspection technique GPR will be demonstrated.
In addition to GPR investigations, geoelectrical measurements, coring and petrophysical investigations have been carried out.
The investigated railway bridge in Olesnica is a typical European masonry arch bridge (age, construction and span length).
It shows typical damage to the masonry arches such as increasing salt concentration, destruction, material losses and longitudinal cracks.
Radar measurements were carried out with two main objectives: (1) Identification of basic geometric dimensions of the bridge and identification of construction details; (2) Evaluation of the condition of the masonry, such as mechanical damage (e.g. cracks) or variation of the moisture content.
Radar antennas of different frequencies (having different penetration depths) have been used to estimate the thickness of the walls.
Because of the high attenuation in the inner masonry structure the measurements have not produced satisfying results, but the radar measurements have been successfully applied to investigate the moisture distribution in the masonry.
These results have been verified by coring and through geoelectrical measurements.
Cracks were studied at two testing areas at one wing wall of the bridge using an automatic 2D radar scanning system.
The radar data were processed using advanced data processing tools like FT-SAFT reconstruction and data fusion.
The processing sequence allowed the creation of high-resolution depth sections (C-Scans).
Moisture ingress is one of major damaging factors for masonry buildings. As the complex resistivity (CR) is sensitive to textural properties as well as to the pore fluid chemistry of wet porous media, its non-destructive application can provide helpful information for conservators. In a comprehensive laboratory study it has been shown that CR might even be able to distinguish between salt content and saturation degree in only one measurement. The combined use of electrical and electromagnetic measurement techniques in two field-scale flooding experiments has shown some unexpected differences. Possible reasons are discussed and it is shown that bringing together the information of both methods leads to a clearer picture.
Complex resistivity (CR) behavior of building material - first results of field scale measurements
(2008)
The influence of moisture on the reliability of detection of larger voids in brickwork masonry was investigated using three non-destructive techniques: radar, ultrasonic and complex resistivity (CR). Radar and ultrasonic travel time tomography, as well as CR tomography, were performed over a specific cross section of a specimen containing a large void at a known position to determine the influence of different levels of moisture content in the brickwork on the wave velocities and the CR magnitude. We defined a numerical estimator to quantitatively determine the void detection efficiency from the images obtained when exposing the specimen to moisture. The results showed radar to be the most reliable technique for void detection in both dry and wet masonry, while CR performed much better in detecting larger air voids in wet masonry.
One of the main problems in the assessment of the operability, stability and contamination potential of tailings facilities is the lack of data on subsurface materials, properties and structures. One key task in the use of geophysics is the selection of the proper methods for a given site/problem combination. Interpretation of the acquired and processed physical data (e.g. electrical resistivity distribution) into something useful for site assessment (e.g. contamination distribution) is another. In the TAILSAFE project (funded by the European Commission) we have worked with partners on the use of geophysics for tailings facilities inspection. DC and complex resistivity, ground penetrating radar, and spectral analysis of surface waves and multichannel analysis of surface waves have been used on dams and beaches. In most cases, our methods provided useful information on the subsurface structure, but the translation of geophysical values into geotechnical or other parameters is still challenging.
Moisture ingress is one of the major deteriorating factors for building materials. Today, the only approved way to assess such damage is the gravimetric Darr method, which is essentially destructive. Substantial progress has been made using the geophysical complex-resistivity method, which can be applied non-destructively and provides spatial information along two-dimensional sections, rather than punctual along one borehole. Considerable advantages of complex resistivity are its sensitivity to textural properties, as well as the pore-fluid chemistry of wet, porous media. In a comprehensive laboratory study, and later in field scale experiments, it could be shown that complex resistivity may even be able to distinguish between salt content and saturation degree in a single measurement. A comparison with complementary nondestructive testing techniques points to the benefit and further research to be explored in multimethodical approaches.