Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (39)
- Posterpräsentation (22)
- Vortrag (21)
- Buchkapitel (3)
- Beitrag zu einem Tagungsband (2)
- Beitrag zu einem Sammelband (1)
- Sonstiges (1)
- Forschungsbericht (1)
Schlagworte
- Laser ablation (32)
- ICP-MS (30)
- Cell (19)
- Imaging (18)
- Nanoparticle (17)
- LA-ICP-MS (11)
- Nanoparticles (7)
- Immunohistochemistry (5)
- Bioimaging (4)
- Copper (4)
- Magnetic resonance imaging (3)
- Mass cytometry (3)
- SERS (3)
- Antibody (2)
- Atomic Force Microscopy (2)
- Bio-imaging (2)
- Calibration (2)
- Cancer (2)
- Cells (2)
- Contrast agent (2)
- Cyanide (2)
- Fluorescence (2)
- Laser ablation (LA)-ICP-MS (2)
- Laser ablation ICP-MS (2)
- Life sciences (2)
- MRI (2)
- Surface-enhanced Raman scattering (2)
- Tissue (2)
- Traceability (2)
- Uncertainty (2)
- X-ray tomography (2)
- AFM (1)
- Affinity (1)
- Alanine scan (1)
- Analytical methods (1)
- BAM-S005 (1)
- Bewitterung (1)
- Binding molecule (1)
- Bio-Imaging (1)
- Bioanalytical methods (1)
- Bioconjugation (1)
- Boden (1)
- Bodenluft (1)
- Brain (1)
- Carbodiimide crosslinking (1)
- CdSe/ZnS quantum Dots (1)
- Cell systems/single cell analysis (1)
- Cellular uptake (1)
- Characterisation (1)
- Chelate (1)
- Chrom(VI) (1)
- Chromium (1)
- Combinatorial chemistry (1)
- Coreshell structures (1)
- DC arc OES (1)
- Diatretglas (1)
- Direct current optical emission spectrometry (1)
- Direct solid sampling technique (1)
- Direkte Feststoffanalytik (1)
- Docking (1)
- EPMA (1)
- ETV ICP OES (1)
- Electrothermal vaporization (1)
- Elemental Distribution (1)
- Endosome (1)
- Evaluierung von Analyseverfahren (1)
- Extracellular matrix (1)
- Fast single pulse response (1)
- Fibroblast (1)
- Fluorescence label (1)
- Fractionation (1)
- GD-MS (1)
- GDMS (1)
- Gadolinium (1)
- Glass (1)
- Glycosaminoglycan (1)
- Gold nanoparticles (1)
- HT22 (1)
- HeLa (1)
- Heavy metals (1)
- Homogeneity (1)
- Homogenität (1)
- ICP-OES (1)
- ICP-ToF-MS (1)
- IDMS (1)
- Immunofluorescence (1)
- Inductively coupled plasma optical emission spectrometry (1)
- Inflammation (1)
- Iron oxide (1)
- Isotope dilution (1)
- Kupfer (1)
- LA-ICP-OES (1)
- LA-ICP-SFMS (1)
- Lab-on-a-chip (1)
- Lanthanoid (1)
- Laser Ablation (1)
- Laser Ablation/Imaging (1)
- Laserablation (1)
- MALDI (1)
- MALDI-TOF MS (1)
- MST (1)
- Magnesium (1)
- Mass spectrometry (1)
- Mass spectrometry/ICP-MS (1)
- Massenspektrometrie (1)
- Messunsicherheit (1)
- Metal (1)
- Metal nanoclusters (1)
- Metals (1)
- Method standardization (1)
- Method validation (1)
- Methodenvalidierung (1)
- Microanalysis (1)
- Molecular imaging (1)
- Multiple sclerosis (1)
- Nanocluster (1)
- Nanomaterial (1)
- National law (1)
- Non-target (1)
- Normung (1)
- OBOC library (1)
- OCP (1)
- On-chip screening (1)
- One-bead-one-compound library (1)
- Organic contaminants (1)
- PAK (1)
- PCB (1)
- PCP (1)
- Particle aggregation (1)
- Particle size distribution (1)
- Peptide (1)
- Peptide aptamers (1)
- Peptide library (1)
- Protein imaging (1)
- Purity (1)
- Quantification (1)
- Quantitative bioimaging (1)
- Reference glasses (1)
- Reference material (1)
- Referenzmaterial (1)
- Referenzmaterialien (1)
- Ringversuche (1)
- SI (1)
- SIMS (1)
- SPR (1)
- Schadstoffaustrag (1)
- Silica nanoparticles (1)
- Siliciumcarbid (1)
- Silicon carbide powder (1)
- Single cell (1)
- Single cell analysis (1)
- Soil (1)
- Spark ablation (1)
- Spark-OES (1)
- Speroid (1)
- Spheroid (1)
- Spurenelemente (1)
- Stabilität (1)
- Standardization (1)
- Sulfur (1)
- Surface plasmon resonance (1)
- Synthetic peptides (1)
- Synthetic standard (1)
- Säulenelution (1)
- Thin tissue sections (1)
- Umweltsimulation (1)
- Vor-Ort-Analytik (1)
- ZRM (1)
- Zinc (1)
- pL-droplets (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (32)
- 1.1 Anorganische Spurenanalytik (31)
- 1.8 Umweltanalytik (5)
- P Präsident (4)
- P.0 Präsident und andere (4)
- 1.5 Proteinanalytik (3)
- 1.6 Anorganische Referenzmaterialien (3)
- 9 Komponentensicherheit (3)
- 9.5 Tribologie und Verschleißschutz (3)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
Eingeladener Vortrag
- nein (21)
Nanoparticles (NPs) have potential applications in medical diagnostics, imaging, drug delivery and other kinds of therapy. Furthermore, studies concerning nanoparticle uptake by cells are important for risk assessment. Size, shape and surface modification of the NPs determine the uptake rate and pathway into the cells, and therefore impact specific cell components and processes. Understanding the different uptake mechanisms and involved processes require sub-cellular resolution to determine, for example, whether the nanoparticles are reaching the nucleus. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is an established quantitative multi-elemental analysis and mapping technique. However, sub-cellular imaging has traditionally been challenging to achieve due to a lack of sensitivity at small laser spots. But now novel laser ablation systems with improved sensitivity and washout time allow imaging at high lateral resolution with spot sizes down to 1 µm.
Here LA-ICP-MS was applied for the imaging of individual fibroblast cells to study the uptake and intracellular processing of metal-containing NPs. To indicate cell morphology the local distribution of naturally occurring elements in cells like P and Zn was measured, too. Our results show that LA-ICP-MS can be used to localise nanoparticle aggregates within cellular compartments. The studied NPs accumulate in the perinuclear region in the course of intracellular processing, but do not enter the cell nucleus. The uptake efficiency depends strongly on the physico-chemical properties of the nanostructures as well as on the incubation conditions like concentration and incubation time. The potential of LA-ICP-MS for analysis at single cell level will be demonstrated.
Studying the interaction of nanoparticles (NPs) with cells has become a growing field of interest. Research topics are ranging from nanotoxicology to medical applications e.g. as theranostic agents. In order to evaluate nano-bio interactions, the number of NPs inside cells as well as their localisation within cellular substructures is of particular interest.
In recent years, elemental imaging of biological samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is gaining more and more importance. Latest instrumental developments regarding spatial resolution (down to 1 µm) and detection efficiency make LA ICP-MS particularly interesting for single cell analysis.
Here, we have applied LA-ICP-MS for sub-cellular scale imaging of individual cells to study the NP pathway from uptake, via intracellular processing up to cell division. Furthermore, the local distribution of naturally occurring elements in cells like P was measured to indicate the cell morphology.
Murine fibroblast cells were incubated with different metal-containing NPs under varying experimental conditions. For LA analysis, the cells were fixed and dried. Sub-cellular resolution was achieved by careful optimisation of the laser ablation parameters. By rastering with the laser beam across the sample, a two-dimensional image of the elemental distribution can be received. Our results show that LA-ICP-MS is able to localise NP aggregates within cellular substructures. The studied NPs accumulate in the perinuclear region in the course of intracellular processing, e.g. multivesicular fusion and endosomal maturation, but do not enter the nucleus. The uptake depends on the physico-chemical properties of the nanostructures and on the incubation conditions like concentration and incubation time. Additionally, the number of NPs internalized by individual cells was determined and variations within a cell population became visible.
The findings demonstrate the potential of LA-ICP-MS providing insight into NP uptake and intracellular distribution dependent on experimental parameters.
Gold nanostructures that serve as probes for nanospectroscopic analysis of eukaryotic cell cultures can be obtained by the in situ reduction of tetrachloroauric acid (HAuCl4). To understand the formation process of such intracellularly grown particles depending on the incubation medium, the reaction was carried out with 3T3 fibroblast cells in three different incubation media, phosphate buffer, Dulbecco's Modified Eagle Medium (DMEM), and standard cell culture medium (DMEM with fetal calf serum). The size, the optical properties, the biomolecular corona, and the localization of the gold nanoparticles formed in situ vary for the different conditions. The combination of surface-enhanced Raman scattering (SERS) and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) microscopic mapping and transmission electron microscopy (TEM) provides complementary perspectives on plasmonic nanoparticles and non-plasmonic gold compounds inside the cells. While for the incubation with HAuCl4 in PBS, gold particles provide optical signals from the nucleus, the incubation in standard cell culture medium leads to scavenging of the toxic molecules and the formation of spots of high gold concentration in the cytoplasm without formation of SERS-active particles inside the cells. The biomolecular corona of nanoparticles formed in situ after incubation in buffer and DMEM differs, suggesting that different intracellular molecular species serve for reduction and stabilization. Comparison with data obtained from ready-made gold nanoparticles suggests complementary application of in situ and ex situ generated nanostructures for optical probing.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is nowadays an established multi-elemental analysis and mapping technique. It was shown that LA-ICP-MS can visualize the elemental distribution within tissue thin sections or cell samples. Quantification is possible by using appropriate matrix-matched calibration samples. Besides naturally occurring elements and metals from contrast agents, biomolecules using metal-tagged antibodies were detected in different bio-medical samples. By combining the results with findings from histology, magnetic resonance imaging (MRI) and other techniques disease related changes like alterations of the extracellular matrix can be investigated.
We have efficiently produced collagen-rich microstructures in fibroblast multicellular spheroids (MCSs) as a three-dimensional in vitro tissue analog to investigate silver (Ag) nanoparticle (NP) penetration. The MCS production was examined by changing the seeding cell number (500 to 40,000 cells) and the growth period (1 to 10 days). MCSs were incubated with Ag NP suspensions with a concentration of 5 μg/mL for 24 h. For this study, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used to visualize Ag NP localization quantitatively. Thin sections of MCSs were analyzed by LA-ICP-MS with a laser spot size of 8 μm to image distributions of 109Ag, 31P, 63Cu, 66Zn, and 79Br. A calibration using a NP suspension was applied to convert the measured Ag intensity into the number of NPs present. The determined numbers of NPs ranged from 30 to 7200 particles in an outer rim of MCS. The particle distribution was clearly correlated with the presence of 31P and 66Zn and was localized in the outer rim of proliferating cells with a width that was equal to about twice the diameter of single cells. Moreover, abundant collagens were found in the outer rim of MCSs. For only the highest seeding cell number, NPs were completely captured at the outer rim, in a natural barrier reducing particle transport, whereas Eosin (79Br) used as a probe of small molecules penetrated into the core of MCSs already after 1 min of exposure.
Polyethylene (PE) frits were used to quantify sulphur in copper and its alloys by isotope dilution combined with LA-ICP-MS as an alternative approach to conventional sample preparation: the copper samples were spiked, the spiked samples were dissolved, the resulting solutions were absorbed in the PE frits and finally the PE frits were analysed by LA-ICP-MS. A prerequisite for such a support material is a low sulphur blank and thus PE was selected for this purpose. The absorption efficiency of the PE frits was studied for varying sulphur amounts ranging from 2 mg S to 80 mg S showing that more than 99.5% of the loaded sulphur was absorbed by the frit. The so prepared PE frits were measured by LA-ICP-MS and yielded a good linearity (R2 ¼ 0.999) for the sulphur ion intensities corresponding to sulphur amounts up to 40 mg S; the associated sensitivity is approximately 3.4 x 10⁴ cps μg⁻¹ for ³²S. For the validation of the developed procedure the reference materials BAM-M376a, BAM-228 and BAM-227 were applied such that 2 μg S, 5 μg S and 11 μg S were absorbed in the PE frits, respectively. These samples were pre-quantified for the adsorbed sulphur amount by external calibration LA-ICP-MS yielding sulphur amounts of 0.9 μg, 5.1 μg and 8.5 μg (quantified for ³²S only), respectively. Relative Standard deviations of the isotope ratios were below 5% in average (n ¼ 3 lines) in all cases (except for the pure spike solution). These samples were then analysed by LA-ICP-IDMS and the measurement results were validated by comparing them with the results obtained by conventional ICP-IDMS. The obtained relative expanded measurement uncertainties ranged between 10% and 26%. Pearson's coefficient was used to express the correlation between both techniques; the obtained value was 0.999 demonstrating a strong correlation. Contrary to most published LA-ICP-IDMS procedures, the developed procedure enables SI-traceability for the measurement results. The metrological traceability to the SI for the sulphur mass fractions in copper was established by an unbroken chain of comparisons, each accompanied by an uncertainty budget. Thus, the measurement results are considered reliable, acceptable and comparable within the stated measurement uncertainty. The metrological traceability chain from the kg down to mass fraction in the samples obtained by LA-ICP-IDMS is presented as well.
Two types of copper samples, compact certified copper reference materials and calibration samples prepared from liquid doped, pressed copper powders, were studied in terms of accuracy of obtained calibration functions originating from infrared spark ablation. Additionally, corresponding particle size distributions of the aerosols from infrared spark ablation were recorded. It is shown that the differences in quantification results, originating from the two sets of calibration functions, could not mainly be ascribed to different particle size distributions of the two copper sample types. Possible other causes, as different ablation rates, parts of melting and differences of the chemical constitutions of the two sample types were explored.