Filtern
Dokumenttyp
- Vortrag (11)
- Posterpräsentation (9)
- Zeitschriftenartikel (5)
- Buchkapitel (3)
- Beitrag zu einem Sammelband (1)
- Sonstiges (1)
Sprache
- Englisch (30) (entfernen)
Referierte Publikation
- nein (30) (entfernen)
Schlagworte
- Laser ablation (18)
- ICP-MS (17)
- Cell (11)
- Imaging (11)
- Nanoparticle (10)
- Bioimaging (4)
- Nanoparticles (4)
- LA-ICP-MS (3)
- Mass cytometry (3)
- Antibody (2)
- Bio-imaging (2)
- Cells (2)
- Immunohistochemistry (2)
- Laser ablation (LA)-ICP-MS (2)
- Life sciences (2)
- Analytical methods (1)
- Atomic Force Microscopy (1)
- Bio-Imaging (1)
- Boden (1)
- Chromium (1)
- Copper (1)
- Cyanide (1)
- Elemental Distribution (1)
- Fluorescence (1)
- Heavy metals (1)
- Isotope dilution (1)
- Lanthanoid (1)
- Laser Ablation (1)
- Laser ablation ICP-MS (1)
- MALDI (1)
- Metals (1)
- Nanocluster (1)
- Nanomaterial (1)
- National law (1)
- Organic contaminants (1)
- Quantification (1)
- Referenzmaterial (1)
- Soil (1)
- Spurenelemente (1)
- Stabilität (1)
- Standardization (1)
- Tissue (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (11)
The traceability and availability of nanoparticles enables their use to enhance a variety of nano-biological and nano-medicinal applications. The particular size and shape of nanoparticles determine the uptake rate and pathway into the cell, and therefore impact specific cell components and processes. Selecting specific particle types allows researchers to target the process or structure of interest, with minimal additional impact. This can be used for drug or DNA delivery, and is being explored for use in oncology. Understanding the different uptake mechanisms and impacted processes requires sub-cellular Imaging resolution to determine, for example, whether or not the nanoparticles are reaching the nucleus.
Sub-cellular imaging has traditionally been challenging to achieve with laser ablation ICP-MS due to a lack of sensitivity at small spots. Bioimaging using LA-ICP-MS is a well-established technique, but usually applied on the tissue scale, which depends on larger spot areas where sensitivity is less problematic. The improved sensitivity and washout from the NWRimage has allowed faster imaging of smaller spots. The NWRimage also provides the possibility of true sub-micron spot sizes. This work compares the capabilities of standard laser Ablation (NWR213 system) with results from the NWRimage platform, which has been optimized for imaging applications.
Nanoparticles (NPs) have found a wide range of applications in research and industry. Thereby the interaction of NPs with biological systems like cells has become a major field of interest, ranging from medical applications to nanotoxicology. Size, shape and surface modification of the nanomaterials determine the uptake rate and pathway into the cells, and therefore impact specific cell components and processes.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is an established quantitative multi-elemental analysis and mapping technique. In recent years, it was shown that LA-ICP-MS can provide quantitative as well as distribution information of metal containing nanoparticles (NPs) in cell samples.
Here LA-ICP-MS was applied for the imaging of individual fibroblast cells to study the uptake and intracellular processing of NPs. Our results show that LA-ICP-MS can be used to localize nanoparticle aggregates within cellular compartments. The studied NPs accumulate in the perinuclear region in the course of intracellular processing, but do not enter the cell nucleus. The uptake efficiency depends strongly on the physico-chemical properties of the nanostructures as well as on the incubation conditions like concentration and incubation time.
ICP-MS was used to determine the composition of the nanomaterials as well as the number of NPs in cells after acid digestion of the samples.
The interaction of nanoparticles (NPs) with cells has become a major field of interest, ranging from therapeutic applications to nanotoxicology. The cellular uptake depends on the primary characteristics of the NPs (e.g. size, shape, surface modification) and on the cells interacting with the particles. Thereby the quantification of NPs in cells is of particular importance to obtain information under different experimental conditions. Presently, the number of NPs internalized is often determined by inductively coupled plasma (ICP) optical emission spectrometry (OES) or ICP mass spectrometry (MS) after acid digestion of a cell suspension or a cell pellet. The result is an average value and no information about the distribution among cells or within a cell is available. Therefore we developed a method based on laser ablation (LA) in combination with ICP-MS to localise and quantify metallic NPs in single cells.
LA-ICP-MS is a powerful analytical method which offers excellent sensitivity at high spatial resolution and multielement capability without time-consuming sample preparation steps. Recently, LA-ICP-MS was established for elemental mapping of biological samples like tissues.
In our experiments, fibroblast cells were incubated with gold or silver containing nanoparticles and grown on sterile coverslips under standard conditions. For LA analysis the cells were fixed with formaldehyde and dried. Subcellular resolution is achived by careful optimisation of laser energy, ablation frequency and scan speed. The elemental distribution was determined by continuous ablation line by line of cells incubated with NPs. Our results show that LA-ICP-MS is able to detect NP aggregates within cellular substructures. After 24 h of incubation the NPs were found in the cytosol, preferencially in the perinuclear region, but do not enter the nucleus. Additionally, a quantification strategy at single-cell level was developed. For this purpose nitrocellulose membrane was spiked with Ag or Au nanoparticle suspension at different concentration levels and analysed by LA-ICP-MS. Based on this calibration the number of NPs taken up by individual cells was determined and variations within the cell population become visible. The cells show a strong dependence of NP uptake on concentration and incubation time.
Our results demonstrate the potential of LA-ICP-MS providing insight into NP uptake and intracellular distribution dependent on experimental parameters.
Many current nanomaterials can serve as contrast agents in cellular or tissue imaging, drug delivery vehicles or therapeutics, whereas others can cause toxic effects. In order to evaluate nano-bio interactions, the number of nanoparticles (NPs) inside cells as well as their localisation within cellular substructures is of particular interest. The cellular uptake depends on the primary characteristics of the NPs (e.g. size, shape, surface coating) and on the cell type.
Laser ablation inductively coupled plasma mass spectrometry (LA‑ICP‑MS) is more and more used to study the NP pathway from uptake, via intracellular processing up to cell division. High-spatial resolution laser ablation at single cell level is achieved using novel low-dispersion LA chambers and by careful optimisation of laser energy, ablation frequency and scan speed at small laser spot sizes down to 1 µm. Different examples from BAM, Division 1.1 and cooperation partners using LA-ICP-MS to localize and quantify metal-containing nanoparticles are shown. The results demonstrate the potential of LA-ICP-MS providing insight into NP uptake, intracellular distribution and cell-to-cell variation.
Nanoparticles (NPs) have potential applications in medical diagnostics, imaging, drug delivery and other kinds of therapy. Furthermore, studies concerning nanoparticle uptake by cells are important for risk assessment. Size, shape and surface modification of the NPs determine the uptake rate and pathway into the cells, and therefore impact specific cell components and processes. Understanding the different uptake mechanisms and involved processes require sub-cellular resolution to determine, for example, whether the nanoparticles are reaching the nucleus. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is an established quantitative multi-elemental analysis and mapping technique. However, sub-cellular imaging has traditionally been challenging to achieve due to a lack of sensitivity at small laser spots. But now novel laser ablation systems with improved sensitivity and washout time allow imaging at high lateral resolution with spot sizes down to 1 µm.
Here LA-ICP-MS was applied for the imaging of individual fibroblast cells to study the uptake and intracellular processing of metal-containing NPs. To indicate cell morphology the local distribution of naturally occurring elements in cells like P and Zn was measured, too. Our results show that LA-ICP-MS can be used to localise nanoparticle aggregates within cellular compartments. The studied NPs accumulate in the perinuclear region in the course of intracellular processing, but do not enter the cell nucleus. The uptake efficiency depends strongly on the physico-chemical properties of the nanostructures as well as on the incubation conditions like concentration and incubation time. The potential of LA-ICP-MS for analysis at single cell level will be demonstrated.
Studying the interaction of nanoparticles (NPs) with cells has become a growing field of interest. Research topics are ranging from nanotoxicology to medical applications e.g. as theranostic agents. In order to evaluate nano-bio interactions, the number of NPs inside cells as well as their localisation within cellular substructures is of particular interest.
In recent years, elemental imaging of biological samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is gaining more and more importance. Latest instrumental developments regarding spatial resolution (down to 1 µm) and detection efficiency make LA ICP-MS particularly interesting for single cell analysis.
Here, we have applied LA-ICP-MS for sub-cellular scale imaging of individual cells to study the NP pathway from uptake, via intracellular processing up to cell division. Furthermore, the local distribution of naturally occurring elements in cells like P was measured to indicate the cell morphology.
Murine fibroblast cells were incubated with different metal-containing NPs under varying experimental conditions. For LA analysis, the cells were fixed and dried. Sub-cellular resolution was achieved by careful optimisation of the laser ablation parameters. By rastering with the laser beam across the sample, a two-dimensional image of the elemental distribution can be received. Our results show that LA-ICP-MS is able to localise NP aggregates within cellular substructures. The studied NPs accumulate in the perinuclear region in the course of intracellular processing, e.g. multivesicular fusion and endosomal maturation, but do not enter the nucleus. The uptake depends on the physico-chemical properties of the nanostructures and on the incubation conditions like concentration and incubation time. Additionally, the number of NPs internalized by individual cells was determined and variations within a cell population became visible.
The findings demonstrate the potential of LA-ICP-MS providing insight into NP uptake and intracellular distribution dependent on experimental parameters.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is nowadays an established multi-elemental analysis and mapping technique. It was shown that LA-ICP-MS can visualize the elemental distribution within tissue thin sections or cell samples. Quantification is possible by using appropriate matrix-matched calibration samples. Besides naturally occurring elements and metals from contrast agents, biomolecules using metal-tagged antibodies were detected in different bio-medical samples. By combining the results with findings from histology, magnetic resonance imaging (MRI) and other techniques disease related changes like alterations of the extracellular matrix can be investigated.
LA-ICP-MS is increasingly used for single cell analysis in two different detection modes using either the imaging mode with subcellular resolution or alternatively single spot analysis of cells with a larger laser spot size. This study compares the analytical figures of merit of both detection modes (signal to noise, precision, accuracy, throughput), as well as ease of operation and data evaluation. Adherent 3T3 fibroblast cells were stained with two metal dyes (mDOTA-Ho, Ir-DNA-intercalator) and several dozen cells were measured using both modes. We found a ten times higher throughput for single spot analysis, which has as well a straightforward data analysis, shortening the total analysis time further. The signal to noise ratio for single spot analysis was found to be slightly better compared to the signal to noise of pixels in imaging. The mean metal intensity per single cell differed by only 10% between both modes and obtained distributions were found to show no statistically significant differences. Using matrix matched calibration based on standards spotted onto nitrocellulose membrane, we achieved detection limits (10s) of 12 fg for Ir and 30 fg for Ho and quantified 57 +/-35 fg Ir and 1192 +/- 707 fg Ho per single cell.
Compared to a conventional ICP-MS measurement of a digest of about 60000 cells, 54% of Ir content and 358% Ho content was found using quantitative LA-ICP-MS. The difference might be a consequence of the two metal dyes binding to different structures of the cell and therefore might behave differently in sample preparation for conventional and LA-ICP-MS.
Quantification of sulphur in copper metals by isotope dilution LA-ICP-MS using polyethylene frits
(2018)
Sulphur is one of the relevant impurities in copper and its alloys affecting their material properties. To ensure the quality of copper products, fast direct solid sampling techniques are very attractive. However, for the calibration suitable matrix reference materials are required. For the certification of such reference materials appropriate, SI-traceable analytical methods are essential. Therefore, a procedure was developed to quantify total sulphur in copper by combining the classical isotope dilution (ID) technique and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS).
Here, for the first time, polyethylene (PE) frits were used to prepare appropriate solid samples for the sulphur quantification in copper metals (alloyed/unalloyed) by isotope dilution LA-ICP-MS. The properties of the PE frit meet the requirements as porous material with high absorption efficiency, thermal and chemical resistance as well as low sulphur blank. Different copper reference materials were used to develop and validate the procedure. The copper samples were spiked with 34S, digested with nitric acid and then the digests were absorbed on PE frits. After drying, the frits were analysed by LA-ICP-IDMS using a Nd:YAG laser at 213 nm coupled to an ICP sector field mass spectrometer. It could be demonstrated, that the sample solution dispersed on the frits did not influence the 32S/34S ratio significantly even though the sulphur intensities were fluctuating along the scanned lines. Relative standard deviations of the isotope ratios were below 5 % in average between three line scans (except for the pure spike solution and procedure blank). The measurement results were validated by comparing them with the results obtained by conventional ICP-IDMS after analyte-matrix separation. Plotting the mass fraction of sulphur in copper obtained by LA-ICP-IDMS versus those obtained by ICP-IDMS yields a linear curve with a correlation coefficient of 0.9999 showing a strong agreement between both techniques.
The metrological traceability to the SI from the kg down to the sulphur mass fraction in copper is established by an unbroken chain of comparisons, each accompanied by an uncertainty budget. Thus, the measurement results are considered reliable, acceptable and comparable within the stated measurement uncertainty.
ICP-MS is a well-established analytical method which excels by high accuracy, high dynamic range and extremely low limits of detection for most metals. Furthermore ICP-MS offers a very high multi-element coverage so that many elements of the periodic table can be detected simultaneously. In this series of lectures, we want to focus on the historical developments, fundamentals, instrumentation and novel applications of ICP-MS in the life and material sciences.