Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (40)
- Posterpräsentation (23)
- Vortrag (22)
- Buchkapitel (3)
- Beitrag zu einem Tagungsband (2)
- Sonstiges (2)
- Beitrag zu einem Sammelband (1)
- Forschungsbericht (1)
Schlagworte
- Laser ablation (34)
- ICP-MS (32)
- Cell (19)
- Imaging (19)
- Nanoparticle (17)
- LA-ICP-MS (11)
- Nanoparticles (7)
- Immunohistochemistry (5)
- Bioimaging (4)
- Contrast agent (4)
- Copper (4)
- Laser ablation ICP-MS (3)
- Magnetic resonance imaging (3)
- Mass cytometry (3)
- SERS (3)
- Spheroid (3)
- Antibody (2)
- Atomic Force Microscopy (2)
- Bio-imaging (2)
- Calibration (2)
- Cancer (2)
- Cells (2)
- Cyanide (2)
- Extracellular matrix (2)
- Fluorescence (2)
- Laser ablation (LA)-ICP-MS (2)
- Life sciences (2)
- MRI (2)
- Surface-enhanced Raman scattering (2)
- Tissue (2)
- Traceability (2)
- Uncertainty (2)
- X-ray tomography (2)
- AFM (1)
- Affinity (1)
- Alanine scan (1)
- Analytical methods (1)
- BAM-S005 (1)
- Bewitterung (1)
- Binding molecule (1)
- Bio-Imaging (1)
- Bioanalytical methods (1)
- Bioconjugation (1)
- Boden (1)
- Bodenluft (1)
- Brain (1)
- Carbodiimide crosslinking (1)
- CdSe/ZnS quantum Dots (1)
- Cell systems/single cell analysis (1)
- Cellular uptake (1)
- Characterisation (1)
- Chelate (1)
- Chrom(VI) (1)
- Chromium (1)
- Combinatorial chemistry (1)
- Coreshell structures (1)
- Crystal (1)
- DC arc OES (1)
- Diatretglas (1)
- Direct current optical emission spectrometry (1)
- Direct solid sampling technique (1)
- Direkte Feststoffanalytik (1)
- Docking (1)
- EPMA (1)
- ETV ICP OES (1)
- Electrothermal vaporization (1)
- Elemental Distribution (1)
- Endosome (1)
- Evaluierung von Analyseverfahren (1)
- Fast single pulse response (1)
- Fibroblast (1)
- Fluorescence label (1)
- Fractionation (1)
- GD-MS (1)
- GDMS (1)
- Gadolinium (1)
- Glass (1)
- Glycosaminoglycan (1)
- Gold nanoparticles (1)
- HT22 (1)
- HeLa (1)
- Heavy metals (1)
- Homogeneity (1)
- Homogenität (1)
- ICP (1)
- ICP-OES (1)
- ICP-ToF-MS (1)
- IDMS (1)
- Immunofluorescence (1)
- Impurity (1)
- Inductively coupled plasma optical emission spectrometry (1)
- Inflammation (1)
- Iron oxide (1)
- Isotope dilution (1)
- Kupfer (1)
- LA-ICP-OES (1)
- LA-ICP-SFMS (1)
- Lab-on-a-chip (1)
- Lanthanoid (1)
- Laser Ablation (1)
- Laser Ablation/Imaging (1)
- Laser cooling (1)
- Laserablation (1)
- LiYF4 (1)
- MALDI (1)
- MALDI-TOF MS (1)
- MST (1)
- Magnesium (1)
- Mass spectrometry (1)
- Mass spectrometry/ICP-MS (1)
- Massenspektrometrie (1)
- Messunsicherheit (1)
- Metal (1)
- Metal nanoclusters (1)
- Metals (1)
- Method standardization (1)
- Method validation (1)
- Methodenvalidierung (1)
- Microanalysis (1)
- Molecular imaging (1)
- Multiple sclerosis (1)
- Nanocluster (1)
- Nanomaterial (1)
- National law (1)
- Non-target (1)
- Normung (1)
- OBOC library (1)
- OCP (1)
- On-chip screening (1)
- One-bead-one-compound library (1)
- Organic contaminants (1)
- PAK (1)
- PCB (1)
- PCP (1)
- Particle aggregation (1)
- Particle size distribution (1)
- Peptide (1)
- Peptide aptamers (1)
- Peptide library (1)
- Protein imaging (1)
- Purity (1)
- Quantification (1)
- Quantitative bioimaging (1)
- Reference glasses (1)
- Reference material (1)
- Referenzmaterial (1)
- Referenzmaterialien (1)
- Ringversuche (1)
- SI (1)
- SIMS (1)
- SPR (1)
- Schadstoffaustrag (1)
- Silica nanoparticles (1)
- Siliciumcarbid (1)
- Silicon carbide powder (1)
- Single cell (1)
- Single cell analysis (1)
- Soil (1)
- Spark ablation (1)
- Spark-OES (1)
- Speroid (1)
- Spurenelemente (1)
- Stabilität (1)
- Standardization (1)
- Sulfur (1)
- Surface plasmon resonance (1)
- Synthetic peptides (1)
- Synthetic standard (1)
- Säulenelution (1)
- Thin tissue sections (1)
- Umweltsimulation (1)
- Vor-Ort-Analytik (1)
- ZRM (1)
- Zinc (1)
- pL-droplets (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (35)
- 1.1 Anorganische Spurenanalytik (34)
- 1.8 Umweltanalytik (5)
- P Präsident (4)
- P.0 Präsident und andere (4)
- 1.5 Proteinanalytik (3)
- 1.6 Anorganische Referenzmaterialien (3)
- 9 Komponentensicherheit (3)
- 9.5 Tribologie und Verschleißschutz (3)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
Eingeladener Vortrag
- nein (22)
Polyethylene (PE) frits were used to quantify sulphur in copper and its alloys by isotope dilution combined with LA-ICP-MS as an alternative approach to conventional sample preparation: the copper samples were spiked, the spiked samples were dissolved, the resulting solutions were absorbed in the PE frits and finally the PE frits were analysed by LA-ICP-MS. A prerequisite for such a support material is a low sulphur blank and thus PE was selected for this purpose. The absorption efficiency of the PE frits was studied for varying sulphur amounts ranging from 2 mg S to 80 mg S showing that more than 99.5% of the loaded sulphur was absorbed by the frit. The so prepared PE frits were measured by LA-ICP-MS and yielded a good linearity (R2 ¼ 0.999) for the sulphur ion intensities corresponding to sulphur amounts up to 40 mg S; the associated sensitivity is approximately 3.4 x 10⁴ cps μg⁻¹ for ³²S. For the validation of the developed procedure the reference materials BAM-M376a, BAM-228 and BAM-227 were applied such that 2 μg S, 5 μg S and 11 μg S were absorbed in the PE frits, respectively. These samples were pre-quantified for the adsorbed sulphur amount by external calibration LA-ICP-MS yielding sulphur amounts of 0.9 μg, 5.1 μg and 8.5 μg (quantified for ³²S only), respectively. Relative Standard deviations of the isotope ratios were below 5% in average (n ¼ 3 lines) in all cases (except for the pure spike solution). These samples were then analysed by LA-ICP-IDMS and the measurement results were validated by comparing them with the results obtained by conventional ICP-IDMS. The obtained relative expanded measurement uncertainties ranged between 10% and 26%. Pearson's coefficient was used to express the correlation between both techniques; the obtained value was 0.999 demonstrating a strong correlation. Contrary to most published LA-ICP-IDMS procedures, the developed procedure enables SI-traceability for the measurement results. The metrological traceability to the SI for the sulphur mass fractions in copper was established by an unbroken chain of comparisons, each accompanied by an uncertainty budget. Thus, the measurement results are considered reliable, acceptable and comparable within the stated measurement uncertainty. The metrological traceability chain from the kg down to mass fraction in the samples obtained by LA-ICP-IDMS is presented as well.
ADAMTS4-specific MR-probe to assess aortic aneurysms in vivo using synthetic peptide libraries
(2022)
The incidence of abdominal aortic aneurysms (AAAs) has substantially increased during the last 20 years and their rupture remains the third most common cause of sudden death in the cardiovascular field after myocardial infarction and stroke. The only established clinical parameter to assess AAAs is based on the aneurysm size. Novel biomarkers are needed to improve the assessment of the risk of rupture. ADAMTS4 (A Disintegrin And Metalloproteinase with ThromboSpondin motifs 4) is a strongly upregulated proteoglycan cleaving enzyme in the unstable course of AAAs. In the screening of a one-bead-one-compound library against ADAMTS4, a low-molecular-weight cyclic peptide is discovered with favorable properties for in vivo molecular magnetic resonance imaging applications. After identification and characterization, it’s potential is evaluated in an AAA mouse model. The ADAMTS4-specific probe enables the in vivo imaging-based prediction of aneurysm expansion and rupture.
Analyse von reinem Kupfer mit LA-ICP-MS: Möglichkeiten der Kalibrierung mit synthetischen Standards
(2007)
A micro-droplet generator (µDG) sample introduction system was coupled to a sector field ICP-MS instrument to investigate the analytical figures of merit with respect to single cell analysis. The sector field instrument was operated for the first time in a fast scanning mode (E-scan) with the shortest time resolution of 100 µs to measure the single droplet time resolved and using the original detector in a pulse counting mode without modification of the existing electronics. For reduction of the droplet diameter a triple pulse mode of the droplet generator was applied and a droplet diameter down to 23 µm has been achieved for this investigation with a 100% transport efficiency of droplets. Signal duration times of single droplets of less than 500 µs have been measured. Overall detection efficiencies in the range of 10-3 counts per atom have been achieved and absolute limits of detection range between 120 ag for Fe and 1.1 ag for Mg as a mean value from 1000 droplet events.