Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (40)
- Beitrag zu einem Tagungsband (27)
- Zeitschriftenartikel (21)
- Posterpräsentation (21)
- Beitrag zu einem Sammelband (2)
- Sonstiges (2)
- Buchkapitel (1)
- Dissertation (1)
Sprache
- Englisch (70)
- Deutsch (43)
- Mehrsprachig (2)
Schlagworte
- Electronic nose (11)
- H2Safety@BAM (10)
- SensRef (6)
- Gassensorik (5)
- Hydrogen (5)
- Voltammetric electronic tongue (5)
- Air quality monitoring (4)
- Ammonia (4)
- Apis mellifera (4)
- Coulometric sensors (4)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (72)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (72)
- 1 Analytische Chemie; Referenzmaterialien (8)
- 8.6 Faseroptische Sensorik (8)
- 1.9 Chemische und optische Sensorik (5)
- 8.4 Akustische und elektromagnetische Verfahren (5)
- 3 Gefahrgutumschließungen; Energiespeicher (4)
- 3.5 Sicherheit von Gasspeichern (4)
- 7 Bauwerkssicherheit (4)
- 1.4 Prozessanalytik (3)
Eingeladener Vortrag
- nein (40)
The project "SealWasteSafe" of the Bundesanstalt für Materialforschung und -prüfung (BAM, Berlin) deals with sealing structures applied for underground disposal of nuclear waste from two perspectives: (1) material improvement for application in sealing constructions and (2) feasibility study regarding multi-sensor approaches to ensure quality assurance and long-term monitoring.
One specimen of 150 l made of alkali-activated material, which was found innovative and suitable for sealing constructions based on preliminary laboratory studies, and, for comparison purpose, another one made of salt concrete, are manufactured with an integrated multi-sensory setup for quality assurance and long-term-monitoring. The specimens were left in their cast form and additionally thermally insulated to simulate the situation in the repository. The multi-sensory concept comprises RFID technology embedded in the specimens suppling material temperature and moisture measurements, integrated fibre optic sensing allowing strain measurement and acoustic emission testing for monitoring possible crack formation. Overall, the suitability and the functionality of the sensors embedded into and attached to strongly alkaline (pH > 13 for the AAM) and salt corrosive (NaCl) environment was proven for the first 672 h.
First temperature measurement based on RFID succeeded after 626 h for the alkali-activated material and after 192 h for the conventional salt concrete. Strain measurement based on distributed fibre optic sensing turned out the alkali-activated material with > 1 mm m-1 undergoing approximately twice the compression strain as the salt concrete with strains < 0.5 mm m-1. In contrast, the acoustic emission first and single hits representing crack formation in numbers, was found for alkali-activated material half of that detected at the salt concrete.
Spices have an important impact on daily aliment. Changes of their quality resulting in far reaching consequences in different foodstuffs and imply financial losing and even health hazard. In this study it is demonstrated that application of two different portable multi gas sensors (electronic nose and ion mobility spectrometer) supported by multivariate data analysis can contribute to ensure quality control of spice mixtures and to find out product adulteration. Headspace above spice mixtures for sausages and saveloy and product counterfeitings was investigated by a metal oxide based electronic nose (e-nose of KAMINA-type). Linear discriminant analysis (LDA) of sensor resistivity data was performed for differentiation. Simultaneously an ion mobility spectrometer (IMS) was coupled to the emission chamber for detection of gaseous components above spice mixtures. The measured spectra show differences between the two spice mixtures and were discussed using a principal component analysis (PCA). The two multigas sensors permit discrimination between the types of spice mixtures and can indicate product adulteration. Additionally, a headspace gas analysis by gas chromatography was performed to identify the main volatile components and to prove the chemical basis for the observed differences of the multi gas sensors.
Application of electronic nose and ion mobility spectrometer to quality control of spice mixtures
(2009)
KonSens (Kommunizierende Sensorsysteme für die Bauteil- und Umweltüberwachung) - Projektergebnisse
(2019)
Im Projekt KonSens werden für die Anwendungsbeispiele bauteilintegrierte Sensorik für Betonkomponenten und mobile Multigassensorik Sensorsysteme in Form von Funktionsmustern entwickelt, validiert und angewendet. Schwerpunkte liegen einerseits in der Detektion und Bewertung von Korrosionsprozessen in Beton und andererseits in der Detektion und Quantifizierung sehr geringer Konzentrationen toxischer Gase in der Luft. Dabei ist die Adaption der sensorischen Methoden aus dem Labor in reale Messumgebungen inklusive geeigneter Kommunikationstechnik ein wichtiger Aspekt.
In the KonSens Project, sensor systems are developed, validated, and operated in form of functional models for the application areas Structure Integrated Sensors and Mobile Multi-gas Sensors. Key aspects are the detection and evaluation of corrosion processes in reinforced concrete structures as well as the detection and quantification of very low concentrations of toxic gases in air. The adaption of sensor principles from the lab into real-life application including appropriate communication techniques is a major task.
In recent years, Structural Health Monitoring have gained in importance, since growing age of buildings and infrastructure as well as increasing load requirements demand for reliable surveillance methods. In this regard, the project follows two strategies: First, the development and implementation of completely embedded sensor systems consisting of RFID-tag and in situ sensors, and their further application potential (e.g. for precast concrete elements, roadways, wind power plants, and maritime structures). Secondly, the development of a long-term stable, miniaturized, fiber optic sensor for a ratiometric and referenced measurement of the pH-value in concrete based on fluorescence detection as an indicator for carbonation and corrosion.
Environmental pollution through emission of toxic gases becomes an increasing problem not only in agriculture (e.g. biogas plants) and industry but also in urban areas. This leads to increasing demand to monitor environmental emissions as well as ambient air and industrial air components in many scenarios and in even lower concentrations than nowadays. The selectivity of luminescence-based sensors is enabled by the combination of the sensing dye and the material, which is used as accumulation medium for concentration of the analyte. This principle allows for developing gas sensors with high selectivity and sensitivity of defined substances. Additional benefits, particularly of fluorescence-based sensors, are their capability for miniaturization and potential multiplex mode. Objective is the development and implementation of sensors based on fluorescence detection for defined toxic gases (ammonia, hydrogen sulfide, ozone, and benzene) with sensitivity in the low ppm or even ppb range. Additionally, the integration of such sensors in mobile sensor devices is addressed.
Im Projekt KonSens werden für die Anwendungsbei-
spiele bauteilintegrierte Sensorik für Betonkomponen-
ten und mobile Multigassensorik Sensorsysteme in
Form von Funktionsmustern entwickelt, validiert und
angewendet. Schwerpunkte liegen einerseits in der
Detektion und Bewertung von Korrosionsprozessen in
Beton und andererseits in der Detektion und Quantifi-
zierung sehr geringer Konzentrationen toxischer Gase
in der Luft. Dabei ist die Adaption der sensorischen
Methoden aus dem Labor in reale Messumgebungen
inklusive geeigneter Kommunikationstechnik ein
wichtiger Aspekt.
Innovation is the catalyst for the technology of the future. It is important to develop new and better technologies that can continuously monitor the environmental impact, e.g., for air Quality control or emission detection. In the recently at BAM developed Universal Pump Sensor Control (UPSC3) module, different components and sensors are fused. The combination of the individual components makes the UPSC3 module an excellent monitoring and reference system for the development and characterization of gas specific sensors. Measurements over long periods are possible, for mixed gas loads or for certain gas measurements. The System is part of a mobile sensor network of several sensor units, which can also be used as standalone systems.
Leaking methane from infrastructures, such as pipelines and landfills, is critical for the environment but can also pose a safety risk. To enable a fast detection and localization of these kind of leaks, BAM developed a novel robotic platform for aerial remote gas sensing. Spectroscopic measurement methods for remote sensing of selected gases lend themselves for use on mini-copters, which offer a number of advantages for inspection and surveillance over traditional methods. No direct contact with the target gas is needed and thus the influence of the copter downwash on the measured gas plume can be kept to a minimum. This allows to overcome one of the major issues with gas-sensitive mini-copters. On the other hand, remote gas sensors, most prominently Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensors have been too bulky given the payload and energy restrictions of mini-copters. Here, we present the Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), which combines a novel lightweight TDLAS sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile multicopter. The proposed system can be deployed in scenarios that cannot be addressed by currently available systems and thus constitutes a significant step forward for the field of Mobile Robot Olfaction (MRO). It enables tomographic reconstruction of gas plumes and a localization of gas sources. We also present first results showing its performance under realistic conditions.
Mit der Initiative QI-Digital werden völlig neue Perspektiven für das Sicherheitsmanagement und die Qualitätssicherung technischer Anlagen erschaffen. Unsere Forschung im Kontext einer Wasserstofftankstelle zeigt, wie digitale Innovationen und Verfahren die Herausforderungen effizienter und verlässlicher Qualitätssicherung für komplexe Anlagen bewältigen können.
In diesem Vortrag werden Potentiale und Beispiele der digitalen QI für technische Anlagen demonstriert und diskutiert: Moderne Anlagenüberwachung mit digitalen Zwillingen und KI sowie Kalibriermanagement mithilfe digitaler Kalibrierscheine und elektronischem Siegel.
Planar coulometric sensors were tested in humidified synthetic air at various gas temperatures. Generated frost point temperature in the gas ranged from -30 °C to -60 °C and were measured by coulometric sensors and in addition by a calibrated dew point hygrometer. The gas temperatures, which were measured by a calibrated Pt100 sensor, were set to -20 °C, 0 °C, 23 °C, 40 °C, 50 °C, and 60 °C during the experiments. Empiric nonlinear functions were calculated between the generated humidity and the sensor signals. In comparison to the measured signals at 23 °C, the sensor signals were lower at the other gas temperatures. The measurements at 60 °C showed indistinct results due to a great signal noise. The response behavior of the sensors was similar at 23 °C, 40 °C and 50 °C. In contrast to that, the sensors reacted slowly at a gas temperature of -20 °C and 0 °C. In summary, with coulometric sensors it was possible to measure continuously trace humidity with an expanded uncertainty below 2 K.