Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (28) (entfernen)
Schlagworte
- Electronic nose (4)
- Air quality monitoring (3)
- Coulometric sensors (3)
- Trace humidity measurement (3)
- Air quality (2)
- Apis mellifera (2)
- Environment (2)
- Gas sensors (2)
- Indoor air quality (2)
- LoRaWAN (2)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (22)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (22)
- 1 Analytische Chemie; Referenzmaterialien (3)
- 1.9 Chemische und optische Sensorik (3)
- 7 Bauwerkssicherheit (1)
- 7.4 Baustofftechnologie (1)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (1)
- 8.6 Faseroptische Sensorik (1)
A new planar sensor element for continuous coulometric trace humidity measurements in industrial gases has been developed. In order to ensure precise measurements a calibration facility including a precision dew point hygrometer as a reference device was developed. The sensor can measure the humidity in the frost point temperature range of -20 °C to -80 °C and has an expanded uncertainty of 2 K, a fast reaction time and a settling time of the entire system from 15 to 30 min.
Because ammonia and its reaction products can cause considerable damage to human health and ecosystems, there is a need for reliably operating and reversibly interacting sensor materials to monitor traces of gaseous ammonia in ambient air, which at best can be used on-site for in-the-field measurements. Herein, the development of a sensor material for gaseous ammonia in the lower ppm to ppb range using optical fluorescence as transduction mechanism is presented. A fluorescent dye, which shows reversible fluorescence enhancement in the presence of ammonia is incorporated into a polymer matrix, the latter to ensure the accumulation of ammonia. The sensor material is integrated into a prototype of a miniaturized sensor device, facilitating long-term operation. To calibrate the optical sensor system a gas standard generator, producing standard gas mixtures, is used, leading to a sensitivity down to lower ppm concentrations of ammonia.
Planar coulometric sensors were tested in humidified synthetic air at various gas temperatures. Generated frost point temperature in the gas ranged from -30 °C to -60 °C and were measured by coulometric sensors and in addition by a calibrated dew point hygrometer. The gas temperatures, which were measured by a calibrated Pt100 sensor, were set to -20 °C, 0 °C, 23 °C, 40 °C, 50 °C, and 60 °C during the experiments. Empiric nonlinear functions were calculated between the generated humidity and the sensor signals. In comparison to the measured signals at 23 °C, the sensor signals were lower at the other gas temperatures. The measurements at 60 °C showed indistinct results due to a great signal noise. The response behavior of the sensors was similar at 23 °C, 40 °C and 50 °C. In contrast to that, the sensors reacted slowly at a gas temperature of -20 °C and 0 °C. In summary, with coulometric sensors it was possible to measure continuously trace humidity with an expanded uncertainty below 2 K.
This work presents a first attempt to use ionic liquids as a new coating for planar coulometric sensors. These sensors are used for the measurement of trace humidity in various gases. Usually, the coating of the sensors is tetraphosphorus decaoxide and its hydrolysis products. Instead, a hygroscopic ionic liquid was used as sensor coating in this work. Generated frost point temperatures tf in the gas ranged from -80 °C to -30 °C, which is equivalent to vapour mole fractions xv from 0.5 μmol·mol-1 to 376 μmol·mol-1. In addition to the coulometric sensors, the generated humidity is determined by a precision dew point hygrometer as reference. First results show that it is possible to measure humidity with ionic liquid based coulometric sensors.
Moisture content and water activity are important parameters for quality characterization of products like bulk materials, powders, granules. Thus, an exact determination is necessarily required in a wide range of industrial applications. Moisture of materials is the content of non-chemically bound water in a solid or liquid. Water activity (aW) is a characteristic/parameter of the non-chemically bound ("free") water in materials and is measured as humidity over a solid/liquid surface at constant temperature (equilibrium moisture content). It is an important parameter to characterize the quality of e. g. pharmaceutical and food products. In our contribution, we present the developed MOISHUM device for staged determination of water activity and moisture content of liquid and solid materials.
Planar coulometric sensors were investigated in humidified synthetic air at various absolute gas pressures, i. e. 2 bar, 5, bar, 10 bar, and 15 bar. Humidified gas flow at adjusted gas pressure was split into two flows, one passed a coulometric sensor and the other one passed a reference hygrometer after decompression. Both signals were recorded and then compared after calculation of resulting frost point temperature. Calculation is based on a calibration function obtained at ambient pressure. Comparison showed that an increasing pressure resulted in a higher derivation between sensor signal (calculated frost point temperature) and reference frost point temperature. At an absolute pressure of 2 bar the differences were minor in consideration of the uncertainty, however at 15 bar the differences were 6.77 K. Nevertheless, it was possible to measure the gas humidity at higher pressure with coulometric trace humidity sensors.
This work presents the testing of a developed elec¬tronic nose for outdoor odour nuisance monitoring. The sensor system consists of a sampling system, a measuring cell equipped with commercially available low-cost gas sensor elements and a data acquisition system. The sensor testing showed that the developed prototype is able to distinguish, identify and partially quantify individual odorous substances like ethanol, ammonia and hydrogen sulphide. Ethanol and ammonia could even be detected below or near their odour threshold.
The efficiency of gas sensor application for facilitating the safe use of hydrogen depends considerably on the sensor response to a change in hydrogen concentration. Therefore, the response time has been measured for five different-type commercially available hydrogen sensors. Experiments showed that all these sensors surpass the ISO 26142 standard; for the response times t90 values of 2 s to 16 s were estimated. Results can be fitted with an exponential or sigmoidal function. It can be demonstrated that the results on transient behaviour depend on both the operating parameters of sensors and Investigation methods, as well as on the experimental conditions: gas change rate and concentration jump.
In this paper, we introduce a nano aerial robot swarm for Indoor Air Quality (IAQ) monitoring applications such as occupational health and safety of (industrial) workplaces. The robotic swarm is composed of nano Unmanned Aerial Vehicles (UAVs), based on the Crazyflie 2.0 quadrocopter, and small lightweight Metal Oxide (MOX) gas sensors for measuring the Total Volatile Organic Compound (TVOC), which is a measure for IAQ. An indoor localization and positioning system is used to estimate the absolute 3D position of the swarm similar to GPS. A test scenario was built up to validate and optimize the swarm for the intended applications. Besides calibration of the IAQ sensors, we performed experiments to investigate the influence of the rotor downwash on the gas measurements at different altitudes and compared them with stationary measurements. Moreover, we did a first evaluation of the gas distribution mapping performance. Based on this novel IAQ monitoring concept, new algorithms in the field of Mobile Robot Olfaction (MRO) are planned to be developed exploiting the abilities of an aerial robotic swarm.
Es wird ein Sensorsystem (HUMItrace III) zur Spurenfeuchtebestimmung in der Prozessmesstechnik vorgestellt. Die Bestimmung der Spurenfeuchte erfolgt mit neuentwickelten planaren Sensoren (HUMItrace-Sensoren) nach dem coulometrischen Messprinzip im Frostpunkttemperaturbereich von -80 °C bis -30 °C mit der Kalibriereinrichtung THG11 durch Mischen von trockenen und befeuchteten Teilgasströmen kalibriert. Die Gasfeuchte von Luft kann in diesem Bereich mit den HUMItrace-Sensoren mit einer erweiterten Unsicherheit von 2 K bestimmt werden. Die Sensoren können aber auch zur Gasfeuchtemessung in Wasserstoff, Stickstoff und Distickstoffmonoxid eingesetzt werden. Eine weitere Kalibriereinrichtung, THG-P12, generiert Prüfgase nach der Permeationsmethode; sie kann in das HUMItrace III Sensorsystem implementiert und zur vor-Ort-Kalibrierung der HUMItrace-Sensoren nach dem Standardadditionsverfahren genutzt werden.