Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (40)
- Beitrag zu einem Tagungsband (28)
- Zeitschriftenartikel (21)
- Posterpräsentation (21)
- Beitrag zu einem Sammelband (2)
- Sonstiges (2)
- Buchkapitel (1)
- Dissertation (1)
Sprache
- Englisch (70)
- Deutsch (44)
- Mehrsprachig (2)
Schlagworte
- Electronic nose (11)
- H2Safety@BAM (10)
- Gassensorik (6)
- SensRef (6)
- Hydrogen (5)
- Voltammetric electronic tongue (5)
- Air quality monitoring (4)
- Ammonia (4)
- Apis mellifera (4)
- Coulometric sensors (4)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (73)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (73)
- 1 Analytische Chemie; Referenzmaterialien (8)
- 8.6 Faseroptische Sensorik (8)
- 1.9 Chemische und optische Sensorik (5)
- 8.4 Akustische und elektromagnetische Verfahren (5)
- 3 Gefahrgutumschließungen; Energiespeicher (4)
- 3.5 Sicherheit von Gasspeichern (4)
- 7 Bauwerkssicherheit (4)
- 1.4 Prozessanalytik (3)
Eingeladener Vortrag
- nein (40)
Spuren leicht flüchtiger organischer Verbindungen mikrobiellen Ursprungs (MVOC) in der Luft von Innenräumen können das Vorhandensein von Schimmelpilzen indizieren. Die Anwendung der Ionenmobilitätsspektrometrie (IMS) zur Detektion von leicht flüchtigen schimmelpilzspezifischenVerbindungen ist wegen ihrer hohen Empfindlichkeit viel versprechend. Um dieses analytisch-chemische Verfahren für eine Innenraumdiagnostik zu nutzen, wurde ein mobil einsetzbares Gerät zur Vor-Ort-Detektion getestet. Im ersten Teil der Arbeit wurden MVOC-Prüfgase im Labor generiert. Die Prüfgase wurden durch permeative Beimengungen in einen definierten Gasstrom hergestellt. Anhand dieser Prüfgase wurden die typischen IMS-Parameter, wie reduzierte Mobilität (K0), relative Driftzeit (trd), Konzentrationsabhängigkeit der Signale und daraus resultierend die Nachweisgrenze des Ionenmobilitätsspektrometer ermittelt. Die bestimmten Nachweisgrenzen der 14 untersuchten MVOC liegen im Bereich zwischen 2 und 192 μg m-3 (1 bis 51 ppbV). Im zweiten Teil wurden sieben oft im Innenraum nachgewiesene Schimmelpilzarten auf Nährmedien kultiviert und ihre produzierten MVOC detektiert. Dabei wurde festgestellt, dass Schimmelpilze art- und altersabhängige MVOC-Emissionen aufweisen. Eine statistische Auswertung und Bestätigung zeigte die Anwendung der Hauptkomponentenanalyse (PCA). Versuchsbegleitend erfolgte eine Identifizierung der MVOC durch gaschromatographische Analysen und bestätigte die IMS-Ergebnisse. Beim Schimmelpilzwachstum einer Mischsporenkultur auf drei verschiedenen Baumaterialien wurden die produzierten MVOC detektiert. Die IMS-Spektren wurden chemometrisch durch eine PCA ausgewertet. Es können die Spektren von unbeimpften und mit Schimmelpilzkulturen beimpften Baumaterialien damit unterscheiden werden ohne die stoffliche Zusammensetzung der Emissionskammerluft zu kennen. Im letzten Teil dieser Arbeit wurde das IMS in 27 Feldversuchen eingesetzt, um MVOC und damit ein Schimmelpilzwachstum in Innenräumen zu detektieren. In 59 % der Fälle wurde eine positive Korrelation zwischen einem sichtbaren Schimmelpilzbefall und den mittels IMS detektierten MVOC ermittelt.
Application of electronic nose and ion mobility spectrometer to quality control of spice mixtures
(2009)
Detection of microbial volatile organic compounds (MVOC) with ion mobility spectrometry (IMS)
(2009)
Traces of microbial volatile organic compounds (MVOCs) in air can indicate the presence of growth of moulds in the indoor environment. Ion-mobility spectrometry is a very promising method for detection of these MVOCs, because of its high sensitivity. For development of an in-situ method for detection of MVOCs, a portable ion-mobility spectrometer (IMS) was used and test gases of 14 MVOCs and their respective mixtures were investigated. IMS spectra were recorded as a function of concentration of MVOCs in air. Drift time and mobility of reactant ions formed in positive polarity mode were determined and correlated with the mass-to-charge ratio (m/z) of the MVOCs investigated. The estimated detection limit has a specific value for each MVOC and is in the range 3 to 96 µg m-3 (1 to 52 ppbV). Indoor trials show that IMS can indicate hidden mould growth.
The metabolism of moulds results in the formation of various microbial volatile organic compounds (MVOCs). These substances can be used as an indicator for the presence of moulds in the indoor environment. Three different mould strains were cultivated on culture media and IMS spectra of gaseous mould metabolites were recorded using a portable mini system with a tritium source and a 5 cm drift cell. The headspace spectra are characteristic for mould species and their age. Typical gaseous components of the metabolites were identified and compared with results obtained from gas chromatography using a mass spectrometer detector. It was observed that the MVOCs formation depends on mould species and their growing stage with a maximum of MVOCs emission occurring during the first 10 days. These preliminary results show that IMS can be applied to detect MVOCs in indoor environment and indicate hidden mould growth.
A new planar sensor element for continuous coulometric trace humidity measurements in industrial gases has been developed. In order to ensure precise measurements a calibration facility including a precision dew point hygrometer as a reference device was developed. The sensor can measure the humidity in the frost point temperature range of -20 °C to -80 °C and has an expanded uncertainty of 2 K, a fast reaction time and a settling time of the entire system from 15 to 30 min.
The detection of the aroma and flavour volatile compounds of spices is key in product quality control. Accordingly, it is necessary to develop new electronic sensing systems for food adulteration control and authenticity assessment for protecting customer's health.
In this work, the capability of the E-nose and VE-tongue in combination with SPME-GC-MS to correctly discriminate between several cumin samples of different geographical origins and to detect their adulteration, by using unsupervised and supervised chemometric tools, was evaluated. Regarding the aroma profile, eleven volatile compounds were characterized by SPME-GC-MS; all of them were found in cumin powder while only eight are found in cumin seeds. The main volatile compounds detected were b-pinene, m-cymene, g-terpinene, cuminaldehyde and cuminic alcohol, in different proportions depending on the cumin sample form (seed or powder). In summary, the results obtained are sufficiently encouraging as a starting point for the development of new electronic sensing systems with more improvement in the reliability of the sensor's performance as well as chemometric tools in order to deal with a complex dataset.
A metrological approach to improve accuracy and reliability of ammonia measurements in ambient air
(2016)
The environmental impacts of ammonia (NH3) in ambient air have become more evident in the recent decades, leading to intensifying research in this field. A number of novel analytical techniques and monitoring instruments have been developed, and the quality and availability of reference gas mixtures used for the calibration of measuring instruments has also increased significantly. However, recent inter-comparison measurements show significant discrepancies, indicating that the majority of the newly developed devices and reference materials require further thorough validation. There is a clear need for more intensive metrological research focusing on quality assurance, intercomparability and validations. MetNH3 (Metrology for ammonia in ambient air) is a three-year project within the framework of the European Metrology Research Programme (EMRP), which aims to bring metrological traceability to ambient ammonia measurements in the 0.5–500 nmol mol−1 amount fraction range. This is addressed by working in three areas: (1) improving accuracy and stability of static and dynamic reference gas mixtures, (2) developing an optical transfer standard and (3) establishing the link between high-accuracy metrological standards and field measurements. In this article we describe the concept, aims and first results of the project.
Pollution through emission of toxic gases is an increasing problem for the environment. It affects similarly agricultural, industrial and urban areas. In future, environmental emissions in ambient air must be monitored at even lower concentrations as nowadays. One environmental relevant compound is ammonia and its conversion product ammonium that have strong negative impact on human health and ecosystems. Most ammonia measurements in ambient air are performed in the range below 1000 nmol·mol-1 and thus there is a need for reliable traceable ammonia gas standards and in addition in situ analytical procedures for monitoring (in ambient air to avoid that thresholds are exceeded). Therefore, the use of reference materials is necessary for development accompanying test or for calibration, e. g. of structure-integrated sensors and mobile multi-gas sensors.
The developed gas standard generator produces gas mixtures that comply with the metrological traceability for ammonia gas standards in the desired environmentally relevant measurement range. The method is based on the permeation of ammonia through a membrane at constant temperature and pressure. The resulting ammonia penetrant gas flow is then mixed with a carrier gas flow to generate a gas standard flow of known concentration. The dynamic rage is enlarged by using a two dilution steps. Depending on the permeation rate, generable molar fractions are possible in the range nmol·mol-1 to a few µmol·mol-1. We present the design of an ammonia gas standard generator and first results of the characterisation of its individual components supporting the uncertainty assessment according to GUM for stable gas concentrations in this range. The relative uncertainty of the generated ammonia gas standard is smaller than 4 % (k = 2).
Because ammonia and its reaction products can cause considerable damage to human health and ecosystems, there is a need for reliably operating and reversibly interacting sensor materials to monitor traces of gaseous ammonia in ambient air, which at best can be used on-site for in-the-field measurements. Herein, the development of a sensor material for gaseous ammonia in the lower ppm to ppb range using optical fluorescence as transduction mechanism is presented. A fluorescent dye, which shows reversible fluorescence enhancement in the presence of ammonia is incorporated into a polymer matrix, the latter to ensure the accumulation of ammonia. The sensor material is integrated into a prototype of a miniaturized sensor device, facilitating long-term operation. To calibrate the optical sensor system a gas standard generator, producing standard gas mixtures, is used, leading to a sensitivity down to lower ppm concentrations of ammonia.
Die Spurenfeuchte von technischen Gasen kann zuverlässig mit coulometrischen Feuchtesensoren bestimmt werden. Das Prinzip dieser Sensoren basiert auf der Absorption von Wasser in einer hygroskopischen Schicht und anschließenderelektrolytischer Zersetzung. Die Kalibrierung der Sensoren erfolgte mit einem Spurenfeuchtegenerator bei Frostpunkttemperaturen kleiner als -30 °C bzw. einem Volumenanteil kleiner als 376 µL·L-1. Die generierte Feuchte wurde zusätzlich zu den coulometrischen Sensoren mit einem Taupunktspiegelhygrometer, welches als Referenz diente, gemessen. Zwischen dem coulometrischen Sensorsignal und der gemessenen Referenzfeuchte wurde eine empirische nichtlinare Funktion gefunden. Die resultierende Kalibrierungsfunktion, die aus zwei Parametern besteht, wurde hinsichtlich ihrer Messunsicherheit bewertet.
Zusätzlich erfolgt die Überprüfung der Kalibrierparameter mittels einfaktorieller Varianzanalyse (ANOVA). Die ANOVA zeigte, dass eine gemittelte Funktion für die Feuchtigkeitbestimmung in Stickstoff, Helium und synthetischer Luft für mehrere Sensoren angewendet werden kann.
Mit coulmetrischen Sensoren ist es möglich, die Spurenfeuchte in technischen Gasen mit einer erweitereten Unsicherheit hinsichtlich der Frostpunkttemperatur kleiner als 2,1 K zu ermitteln.
Leaking methane (CH4) from infrastructures, such as pipelines and landfills, is critical for the environment but can also pose a safety risk. To enable a fast detection and localization of these kind of leaks, we developed a novel robotic platform for aerial remote gas sensing. Spectroscopic measurement methods for remote sensing of selected gases lend themselves for use on mini-copters, which offer a number of advantages for inspection and surveillance over traditional methods. No direct contact with the target gas is needed and thus the influence of the aerial platform on the measured gas plume can be kept to a minimum. This allows to overcome one of the major issues with gas-sensitive mini-copters. On the other hand, remote gas sensors, most prominently Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensors have been too bulky given the payload and energy restrictions of mini-copters. Here, we present the Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), which combines a novel lightweight TDLAS sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile hexacopter. The proposed system can be deployed in scenarios that cannot be addressed by currently available robots and thus constitutes a significant step forward for the field of Mobile Robot Olfaction (MRO). It enables tomographic reconstruction of gas plumes and a localization of gas sources. We also present first results showing its performance under realistic conditions.
Planar coulometric sensors were tested in humidified synthetic air at various gas temperatures. Generated frost point temperature in the gas ranged from -30 °C to -60 °C and were measured by coulometric sensors and in addition by a calibrated dew point hygrometer. The gas temperatures, which were measured by a calibrated Pt100 sensor, were set to -20 °C, 0 °C, 23 °C, 40 °C, 50 °C, and 60 °C during the experiments. Empiric nonlinear functions were calculated between the generated humidity and the sensor signals. In comparison to the measured signals at 23 °C, the sensor signals were lower at the other gas temperatures. The measurements at 60 °C showed indistinct results due to a great signal noise. The response behavior of the sensors was similar at 23 °C, 40 °C and 50 °C. In contrast to that, the sensors reacted slowly at a gas temperature of -20 °C and 0 °C. In summary, with coulometric sensors it was possible to measure continuously trace humidity with an expanded uncertainty below 2 K.
Innovation is the catalyst for the technology of the future. It is important to develop new and better technologies that can continuously monitor the environmental impact, e.g., for air quality control or emission detection. In the recently at BAM developed Universal Pump Sensor Control (UPSC3) module, different components and sensors are fused. The combination of the individual components makes the UPSC3 module an excellent monitoring and reference system for the development and characterization of gas specific sensors. Measurements over long periods are possible, for mixed gas loads or for certain gas measurements. The system is part of a mobile sensor network of several sensor units, which can also be used as standalone systems.
The motivation and objective of this research is to develop gas sensors based on fluorescence detection with range of ppm / ppb. For this task a reference system is required, which contains volatile organic compound (VOC) sensors for reference data from different scenarios. The integrated multi-sensor unit can measure different gases through the integrated 3-fold VOC sensor, which can be adapted to the addressed scenario. . The system-integrated flow control, with pump and flow sensor, allows the gas molecules to be transported directly to the VOC sensor. The entire measurement is permanently stored on an integrated memory card. If the previously determined limit range is exceeded, an alarm is generated. The system is an important tool towards further developments in the field of gas sensors and is primarily used for the validation of chemically based gas sensors.
In the KonSens Project, sensor systems are developed, validated, and operated in form of functional models for the application areas Structure Integrated Sensors and Mobile Multi-gas Sensors. Key aspects are the detection and evaluation of corrosion processes in reinforced concrete structures as well as the detection and quantification of very low concentrations of toxic gases in air. The adaption of sensor principles from the lab into real-life application including appropriate communication techniques is a major task.
In recent years, Structural Health Monitoring have gained in importance, since growing age of buildings and infrastructure as well as increasing load requirements demand for reliable surveillance methods. In this regard, the project follows two strategies: First, the development and implementation of completely embedded sensor systems consisting of RFID-tag and in situ sensors, and their further application potential (e.g. for precast concrete elements, roadways, wind power plants, and maritime structures). Secondly, the development of a long-term stable, miniaturized, fiber optic sensor for a ratiometric and referenced measurement of the pH-value in concrete based on fluorescence detection as an indicator for carbonation and corrosion.
Environmental pollution through emission of toxic gases becomes an increasing problem not only in agriculture (e.g. biogas plants) and industry but also in urban areas. This leads to increasing demand to monitor environmental emissions as well as ambient air and industrial air components in many scenarios and in even lower concentrations than nowadays. The selectivity of luminescence-based sensors is enabled by the combination of the sensing dye and the material, which is used as accumulation medium for concentration of the analyte. This principle allows for developing gas sensors with high selectivity and sensitivity of defined substances. Additional benefits, particularly of fluorescence-based sensors, are their capability for miniaturization and potential multiplex mode. Objective is the development and implementation of sensors based on fluorescence detection for defined toxic gases (ammonia, hydrogen sulfide, ozone, and benzene) with sensitivity in the low ppm or even ppb range. Additionally, the integration of such sensors in mobile sensor devices is addressed.