Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (40)
- Beitrag zu einem Tagungsband (27)
- Zeitschriftenartikel (21)
- Posterpräsentation (21)
- Beitrag zu einem Sammelband (2)
- Sonstiges (2)
- Buchkapitel (1)
- Dissertation (1)
Sprache
- Englisch (70)
- Deutsch (43)
- Mehrsprachig (2)
Schlagworte
- Electronic nose (11)
- H2Safety@BAM (10)
- SensRef (6)
- Gassensorik (5)
- Hydrogen (5)
- Voltammetric electronic tongue (5)
- Air quality monitoring (4)
- Ammonia (4)
- Apis mellifera (4)
- Coulometric sensors (4)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (72)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (72)
- 1 Analytische Chemie; Referenzmaterialien (8)
- 8.6 Faseroptische Sensorik (8)
- 1.9 Chemische und optische Sensorik (5)
- 8.4 Akustische und elektromagnetische Verfahren (5)
- 3 Gefahrgutumschließungen; Energiespeicher (4)
- 3.5 Sicherheit von Gasspeichern (4)
- 7 Bauwerkssicherheit (4)
- 1.4 Prozessanalytik (3)
The objective of this work is to report the improvement obtained in the discrimination of complex aroma and taste with subtle differences in odor and flavor, by the use of fast suitable procedures for the cases of measurements in the field demanding decision-making in real time. The proposed electronic sensing systems, formed by an E-nose and VE-tongue, were used to discriminate cumin cultivars from different geographical origins, as well as to quantify the cumin adulteration percentages by using unsupervised and supervised chemometric tools. Thus, the results obtained are sufficiently encouraging as a starting point for the development of new electronic sensing systems with more improvement such the reliability of the sensors’ performance as well as the chemometric tools in order to deal with a complex dataset.
Pollution through emission of toxic gases is an increasing problem for the environment. It affects similarly agricultural, industrial and urban areas. In future, environmental emissions in ambient air must be monitored at even lower concentrations as nowadays. One environmental relevant compound is ammonia and its conversion product ammonium that have strong negative impact on human health and ecosystems. Most ammonia measurements in ambient air are performed in the range below 1000 nmol·mol-1 and thus there is a need for reliable traceable ammonia gas standards and in addition in situ analytical procedures for monitoring (in ambient air to avoid that thresholds are exceeded). Therefore, the use of reference materials is necessary for development accompanying test or for calibration, e. g. of structure-integrated sensors and mobile multi-gas sensors.
The developed gas standard generator produces gas mixtures that comply with the metrological traceability for ammonia gas standards in the desired environmentally relevant measurement range. The method is based on the permeation of ammonia through a membrane at constant temperature and pressure. The resulting ammonia penetrant gas flow is then mixed with a carrier gas flow to generate a gas standard flow of known concentration. The dynamic rage is enlarged by using a two dilution steps. Depending on the permeation rate, generable molar fractions are possible in the range nmol·mol-1 to a few µmol·mol-1. We present the design of an ammonia gas standard generator and first results of the characterisation of its individual components supporting the uncertainty assessment according to GUM for stable gas concentrations in this range. The relative uncertainty of the generated ammonia gas standard is smaller than 4 % (k = 2).
Die Spurenfeuchte von technischen Gasen kann zuverlässig mit coulometrischen Feuchtesensoren bestimmt werden. Das Prinzip dieser Sensoren basiert auf der Absorption von Wasser in einer hygroskopischen Schicht und anschließenderelektrolytischer Zersetzung. Die Kalibrierung der Sensoren erfolgte mit einem Spurenfeuchtegenerator bei Frostpunkttemperaturen kleiner als -30 °C bzw. einem Volumenanteil kleiner als 376 µL·L-1. Die generierte Feuchte wurde zusätzlich zu den coulometrischen Sensoren mit einem Taupunktspiegelhygrometer, welches als Referenz diente, gemessen. Zwischen dem coulometrischen Sensorsignal und der gemessenen Referenzfeuchte wurde eine empirische nichtlinare Funktion gefunden. Die resultierende Kalibrierungsfunktion, die aus zwei Parametern besteht, wurde hinsichtlich ihrer Messunsicherheit bewertet.
Zusätzlich erfolgt die Überprüfung der Kalibrierparameter mittels einfaktorieller Varianzanalyse (ANOVA). Die ANOVA zeigte, dass eine gemittelte Funktion für die Feuchtigkeitbestimmung in Stickstoff, Helium und synthetischer Luft für mehrere Sensoren angewendet werden kann.
Mit coulmetrischen Sensoren ist es möglich, die Spurenfeuchte in technischen Gasen mit einer erweitereten Unsicherheit hinsichtlich der Frostpunkttemperatur kleiner als 2,1 K zu ermitteln.
Planar coulometric sensors were tested in humidified synthetic air at various gas temperatures. Generated frost point temperature in the gas ranged from -30 °C to -60 °C and were measured by coulometric sensors and in addition by a calibrated dew point hygrometer. The gas temperatures, which were measured by a calibrated Pt100 sensor, were set to -20 °C, 0 °C, 23 °C, 40 °C, 50 °C, and 60 °C during the experiments. Empiric nonlinear functions were calculated between the generated humidity and the sensor signals. In comparison to the measured signals at 23 °C, the sensor signals were lower at the other gas temperatures. The measurements at 60 °C showed indistinct results due to a great signal noise. The response behavior of the sensors was similar at 23 °C, 40 °C and 50 °C. In contrast to that, the sensors reacted slowly at a gas temperature of -20 °C and 0 °C. In summary, with coulometric sensors it was possible to measure continuously trace humidity with an expanded uncertainty below 2 K.
Because ammonia and its reaction products can cause considerable damage to human health and ecosystems, there is a need for reliably operating and reversibly interacting sensor materials to monitor traces of gaseous ammonia in ambient air, which at best can be used on-site for in-the-field measurements. Herein, the development of a sensor material for gaseous ammonia in the lower ppm to ppb range using optical fluorescence as transduction mechanism is presented. A fluorescent dye, which shows reversible fluorescence enhancement in the presence of ammonia is incorporated into a polymer matrix, the latter to ensure the accumulation of ammonia. The sensor material is integrated into a prototype of a miniaturized sensor device, facilitating long-term operation. To calibrate the optical sensor system a gas standard generator, producing standard gas mixtures, is used, leading to a sensitivity down to lower ppm concentrations of ammonia.
The fluorescence properties of three molecular rotors, related to 4-dimethylamino-4-nitrostilbene (4-DNS), are studied versus different diesel/kerosene blends. In nonviscous solvents, these compounds can populate a twisted intramolecular charge transfer state which deactivates nonradiatively, successfully suppressing fluorescence emission. Solution experiments with diesel/kerosene blends showed a good linear correlation between the fluorescence intensity of the probe molecules and the diesel fraction of the blend. The dyes have been immobilized on paper, retaining their fluorescence behavior, i.e., negligible emission in the presence of nonviscous organic solvents and increasing fluorescence when the environment is increasingly viscous. When the impregnated paper is devised as a test strip, the latter is compatible with a newly designed smartphone reader system, which allows in-the-field measurements. The method can safely detect the presence of kerosene in diesel at ≥7%, which competes favorably with current standard methods for the detection of diesel adulteration.
Ionische Flüssigkeiten als neuartige Sensorbeschichtung für coulometrische Spurenfeuchtesensoren
(2018)
Die Arbeit präsentiert erste Messungen mit coulometrischen Sensoren, die mit einer ionischen Flüssigkeit beschichtet sind. Diese Sensoren werden in der Industrie verwendet, um die Spurenfeuchte in unterschiedlichen Gasen zu messen. Normalerweise erfolgt eine Beschichtung der Sensoren mit Phosphorpentoxid und dessen Hydrolyseprodukte. In dieser Arbeit wurde stattdessen eine hygroskopische ionische Flüssigkeit benutzt. Die generierte Gasfeuchte für die Untersuchungen betrug bezogen auf die Frostpunkttemperatur -80 °C bis -30 °C, was gleichbedeutend mit einem Wasserdampf-Stoffmengenanteil von 0,5 μmol·mol-1 bis 376 μmol·mol-1 ist. Zusätzlich zu der Messung mit coulometrischen Sensoren erfolgte eine Referenzmessung der Gasfeuchte mittels eines Taupunkthygrometers. Erste Ergebnisse haben gezeigt, dass es möglich ist mit dieser Art der Beschichtung unterschiedliche Gasfeuchten zu messen. Aber es ergaben sich trotz gleicher Feuchte unterschiedliche Signalintensitäten bei den benutzen Sensoren und es zeigte sich eine Drift des Sensorsignales.
Planar coulometric sensors were investigated in humidified synthetic air at various absolute gas pressures, i. e. 2 bar, 5, bar, 10 bar, and 15 bar. Humidified gas flow at adjusted gas pressure was split into two flows, one passed a coulometric sensor and the other one passed a reference hygrometer after decompression. Both signals were recorded and then compared after calculation of resulting frost point temperature. Calculation is based on a calibration function obtained at ambient pressure. Comparison showed that an increasing pressure resulted in a higher derivation between sensor signal (calculated frost point temperature) and reference frost point temperature. At an absolute pressure of 2 bar the differences were minor in consideration of the uncertainty, however at 15 bar the differences were 6.77 K. Nevertheless, it was possible to measure the gas humidity at higher pressure with coulometric trace humidity sensors.
Emissions of ammonia into the environment are mainly caused by agriculture, but also by combustion processes in waste and by road traffic. Even at low concentrations, this substance is not only an odour nuisance, but also a substance with ecological and climatic relevance. Therefore, BAM tested commercial electrochemical, and metal oxide based sensors, which have limited suitability for measuring in the environmental molar fraction range. Alternatively, own developments for the detection of ammonia in the trace range were implemented, wherein the analyte is measured by changing the fluorescence of a BODIPY dye at 550 nm by means of a portable fluorescence sensor directly from the gas phase. For the calibration of ammonia sensors and measuring instruments, a stationary system based on the mixture of certified test gases from pressure cylinders with calibrated mass flow controllers is available. A test gas generator was developed for on-site calibration and testing of sensors and measuring devices. The generation of ammonia-containing gases in the environmental relevant range of levels below 1000 nmol/mol is carried out by the permeation method according to ISO 6145-10. For the traceability of ammonia, standards are provided and further developed by the National Metrological Institutes and designated institutes. Metrological standards are based on SI units and are a basis for traceability of sensors or gas analysers.