A method is proposed to determine the effective detector area for energy-dispersive X-ray spectrometers (EDS). Nowadays, detectors are available for a wide range of nominal areas ranging from 10 up to 150mm2. However, it remains in most cases unknown whether this nominal area coincides with the “net active sensor area” that should be given according to the related standard ISO 15632, or with any other area of the detector device. Moreover, the specific geometry of EDS installation may further reduce a given detector area. The proposed method can be applied to most scanning electron microscope/EDS configurations. The basic idea consists in a comparison of the measured count rate with the count rate resulting from known X-ray yields of copper, titanium, or silicon. The method was successfully tested on three detectors with known effective area and applied further to seven spectrometers from different manufacturers. In most cases the method gave an effective area smaller than the area given in the detector description.
To compare the performance of different energy dispersive X-ray spectrometers (EDS), it is important to define characteristic spectrometer parameters. The ISO 15632 standard defines parameters like energy resolution as FWHM for the Kα lines of carbon, fluorine and manganese. The quantum efficiency, which is the ratio of the detected photons divided by the number of incoming photons for different energies, is another significant spectrometer property. It is important for the light element and low energy line detection sensitivity as well as for higher photon energies above 10 keV. A striking EDS feature, provided and marketed by many manufactures, is the active area of the detector, although actually, the solid angle available for photon collection is the more relevant geometrical parameter. It is defined as: Ω = A /r2 with A being the active area of a spherical detector and r being the distance between the point of the radiation origin and the center of the surface of the active detector chip. A more accurate calculation should be used for large flat detector areas. One should note that the solid angle Ω is not an intrinsic spectrometer property. It can only be defined for a specific detector in combination with a specific system (e.g. SEM, EPMA or TEM). Thus, the minimal possible distance r is determined by the particular geometry e.g. a possible interference with the pole piece or other detectors/components in the chamber of a microscope. New EDS technologies use e.g. integrated SDD chips or inclined chips in thinner detector fingers which can be placed closer to the sample with the final result of larger real solid angles. Therefore, the knowledge of the real solid angle is one of the crucial parameters of an EDS microscope combination. A straightforward way to estimate the real solid angle is to simply determine A and r. If respective data are not provided by the manufacturer, this approach can be difficult.