Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (17)
- Beitrag zu einem Tagungsband (10)
- Vortrag (4)
- Forschungsbericht (1)
Schlagworte
- Behälterversagen (6)
- Druckbehälter (5)
- Degradation (4)
- Auswirkungsbetrachtung (3)
- Betriebssicherheit (3)
- Consequences (3)
- Explosion (3)
- Faserverbundwerkstoffe (3)
- Reproduzierbarkeit (3)
- Alternative Antriebe (2)
Organisationseinheit der BAM
- 3 Gefahrgutumschließungen; Energiespeicher (9)
- 3.0 Abteilungsleitung und andere (8)
- 8 Zerstörungsfreie Prüfung (5)
- 2 Prozess- und Anlagensicherheit (3)
- 2.1 Sicherheit von Energieträgern (3)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (3)
- 8.6 Faseroptische Sensorik (3)
- 2.2 Prozesssimulation (2)
- 7 Bauwerkssicherheit (2)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (2)
Eingeladener Vortrag
- nein (4)
In einer Großversuchsserie wurden auf dem BAM-TTS 15 11-kg-Propangasflaschen ohne Sicherheitseinrichtung mit drei verschiedenen Methoden (Holz, Benzinpool, Gas) unterfeuert. Der Beitrag beschreibt die dokumentierten Auswirkungen (z. B. Fragmentierung, Überdruck), die Art des Versagens sowie den Behälterzustand zum Zeitpunkt des Versagens.
Commercial, off-the shelf propane cylinders are subjected to high safety regulations. Furthermore, those cylinders are equipped with safety devices like pressure relief valves (PRV). Despite these regulations and safety measures, a failure of the Container is possible if exposed to an intense fire. The result of this is severe hazard for users, rescue forces and infrastructure. Within the framework of a destructive test series, 15 identical propane cylinders, without pressure relief devices, were exposed to an intensive fire in horizontal Position until failure. Each cylinder was filled with a mass of m =11 kg of liquid propane. Three different fire sources were used (wood, petrol, propane). The experiments revealed the failure of all cylinders in a time period t < 155 s. The failure lead to a fragmentation into several major parts with throwing distances of up to l =262 m. In all trials, the temperature of the cylinder wall (top, side, bottom), of the liquid phase inside and of the surrounding fire (top, side, bottom) was recorded. In addition, the inner cylinder pressure and the induced overpressure of the blast wave after the failure were recorded. Overpressures of up to p=0.27 bar were recorded close to the cylinder (l =5 m). AM tests were documented hy video from several positions (general view, close-up, high-speed 5000 fps). This test series creates the basis for further experimental studies in the field of alternative fuels for vehicles. The aim of this test series is to assess and analyse the consequences of the failure of gas vessels (for LPG, CNG, CGH2) in the aftermath of severe incidents.
In Deutschland gibt es eine große Anzahl von Kraftfahrzeugen, die mit alternativen Antrieben (z. B. LPG (Liquefied Petroleum Gas), CNG (Compressed Natural Gas)) ausgerüstet sind. In zahlreichen Großversuchsserien untersucht die Bundesanstalt für Materialforschung und -prüfung (BAM) im Rahmen des internen Forschungsprojekts CoFi-ABV (Complex Fires – Auswirkungen von Behälterversagen) die Auswirkungen beim Versagen der Treibstoffbehälter dieser alternativen Antriebe. Ziel dieser Untersuchungen ist eine ganzheitliche Auswirkungsbetrachtung, um die Risiken für Feuerwehren und Rettungskräfte besser abschätzen zu können. Im Vorfeld zu den Versuchen für LPG- und CNG-Tanks wurden in einer weiteren Versuchsserie 15handelsübliche 11-kg-Propangasflaschen ohne Sicherheitseinrichtung unterfeuert. Alle 15 Behälter haben – wie zu erwarten war – versagt. Neben den Zustandsdaten des Behälters zum Versagenszeitpunkt (Temperatur des Behältermantels, Innendruck und -temperatur) wurden die Auswirkungen auf die Umgebung hinsichtlich Druckwirkung und Fragmentierung (Anzahl, Masse, Distanz, Richtung) dokumentiert.
Im Rahmen einer Bachelorarbeit zum Thema „Untersuchungen an Bremsleitungsabschnittsreparaturen“ zwischen der HTW Berlin und der TÜV Rheinland Kraftfahrt GmbH wurden in Zusammenarbeit mit der Bundesanstalt für Materialforschung und -prüfung (BAM) Berstdruckprüfungen durchgeführt. Im Rahmen der Kooperation sollte untersucht werden, inwiefern Reparaturmaßnahmen an beschädigten Bremsleitungsabschnitten sicherheitstechnisch unbedenklich sind, auch in Bezug auf die Verwendung unterschiedlicher auf dem Markt erhältlicher Bremsleitungsmaterialien.
Compressed natural gas (CNG) is a widely used automotive fuel in a variety of countries. In case of a vehicle fire where the safety device also malfunctions, a failure of the CNG automotive cylinder could occur. Such a cylinder failure is associated with severe hazards for the surrounding environment. Firstly, a comprehensive analysis is given below, summarizing various accidents involving CNG automotive cylinders and their consequences. In an extensive experimental program, 21 CNG automotive cylinders with no safety device were tested. Of the 21, burst tests were carried out on 5 Type III and 5 Type IV cylinders. Furthermore, fire tests with 8 Type III and 3 Type IV cylinders were conducted. Apart from cylinder pressure, inner temperature and cylinder mantle temperature, the periphery consequences, such as nearfield blast pressure and fragmentation are documented. The maximum measured overpressure due to a Type III cylinder failure was p = 0.41 bar. Each traceable fragment was georeferenced. All-in-all, fragment throw distances of d > 300 m could be observed. As one key result, it can be stated that the tested Type IV CNG cylinders showed less critical failure behavior then the Type III cylinders under fire impingement.
15 identical off-the-shelf propane cylinders (m = 11 kg liquid propane) were underfired. The infrared Radiation of the Explosion, that occurred in the aftermath of the vessel failure, was recorded using four bolometers. These measurements are compared with an estimation of the Maximum intensity gained by an Analysis of the Video data, an Extended Version of the Stefan-Boltzmann law and a BLEVE model.
In case of a vehicle fire, an installed LPG (liquefied petroleum gas) tank with a malfunctioning safety device poses severe hazards. To investigate the consequences in case of tank failure, we conducted 16 tests with toroidal shaped LPG vehicle tanks. Three tanks were used for a Hydraulic Burst Test under standard conditions. Another three tanks were equipped with a statutory safety device and were subjected to a gasoline pool fire. The safety device prevented tank failure, as intended. To generate a statistically valid dataset on tank failure, ten tanks without safety devices were exposed to a gasoline pool fire. Five tanks were filled to a level of 20 %; the re-maining five were filled to a level of 100 %. In order to gain information on the heating process, three tem-perature readings at the tank surface, and three nearby flame temperatures were recorded. At distances of l = (7; 9; 11) m to the tank, the overpressure of the shock wave induced by the tank failure and the unsteady tem-peratures were measured. All ten tanks failed within a time of t < 5 min in a BLEVE (boiling liquid expanding vapor explosion). Seven of these resulted directly in a catastrophic failure. The other three resulted in partial failure followed by catastrophic failure. A near field overpressure at a distance of l = 7 m of up to p = 0.27 bar was measured. All ten tests showed massive fragmentation of the tank mantle. In total, 50 fragments were found. These 50 fragments make-up 88.6 % of the original tank mass. Each fragment was georeferenced and weighed. Fragment throwing distances of l > 250 m occurred. For the tanks with a fill level of 20 %, the average number of fragments was twice as high as it was for the tanks that were filled completely.
In continuation of a preceding test series involving sole LPG vehicle tanks, three passenger cars equipped with identical toroidal steel LPG tanks were set on fire. The tanks were installed in the space normally reserved for the spare tyre, in the car boot. No safety device was installed on the tank, in order to force critical failure of the cylinder. Two of the cars were equipped with a tank filled with liquefied propane to a level of 20 % (5.3 kg), the third one was filled completely (25.5 kg). The partially filled tanks failed critically within a time period of more than 20 min after the initiation of the fire. The fully-filled tank did not rupture; the propane was released continuously through a small leak that appeared during the fire. Comprehensive equipment was used to procure measurement data, enabling an analysis of potential consequences and hazards to humans and infrastructure within the vehicle surroundings. The inner status of the tank (pressure, temperature of the liquid phase and the steel casing), the development of the fire (temperature inside and around the vehicle) and the pressure induced in the near-field in case of tank rupture were recorded. The results were analysed in detail and compared against the data gained in tests involving sole, but identical LPG tanks.
Entwickelt und validiert - Probengeometrie zur Untersuchung von gewickelten Faserverbundproben
(2012)
Durch die beschriebene, auf eine Umfangsbelastung ausgelegte Probengeometrie werden
Fertigung und Einsatz von Druckbehältern nachempfunden. Dafür wurden bereits bestehende
Probenformen überarbeitet, um im Probenkörper eine unidirektionale Zugbelastung zu
erzeugen. Da die endgültigen Eigenschaften von faserverstärktem Kunststoff erst in der
Fertigung entstehen, sind gleiche Fertigungsbedingungen von Proben und Bauteilen wichtig.
Die hier vorgestellte Probe verspricht dadurch eine gute Eignung für den Einsatz bei Untersuchungen
zum Zeitstandsverhalten.
Die aktuelle Praxis, auch die wiederkehrende Prüfung von Druckgefäßen aus Verbundwerkstoffen primär auf die hydraulische Innendruckprüfung abzustellen, ist sowohl bezüglich der Schädigung der Prüfmuster als auch ihrer Aussagekraft kritisch zu bewerten. Entsprechend kommt durch die BAM Bundesanstalt für Materialforschung und -prüfung zur Absicherung bei der Zulassung von Prüffristen für Composite-Druckgefäßen von mehr als fünf Jahren ein neuer Ansatz zur Anwendung. Er ermöglicht eine Zustandsabschätzung der Population eines Baumusters auf der Basis wiederholt betriebsbegleitend zerstörender Prüfungen. Ein wesentlicher Aspekt dieses Ansatzes ist die Prognose der sicheren Restlebensdauer. In Fällen, in denen diese nicht wie in den Teilen 1 und 2 beschrieben mittels hydraulischer Lastwechselprüfungen abgeschätzt werden kann, bleiben als Ersatz die Zeitstands- oder die Berstprüfung. Als Kombination aus diesen beiden Prüfungen schlägt die BAM die 'langsame Berstprüfung' vor. Zu diesem Prüfkonzept werden zahlreiche Ergebnisse dargestellt. Hierzu werden sowohl die Parameter der Prüfung wie auch die Art und Intensität der Vorschädigung künstlich gealterter Prüfmuster statistisch ausgewertet. Dies führt zum einen zu einer Bewertung der verschiedenen Belastungsarten aber auch zu der eindeutigen Empfehlung, die heute üblicherweise schnellen Berstprüfungen zum Nachweis der Festigkeit von Composite-Druckgefäßen am besten ganz zu ersetzen.