Filtern
Dokumenttyp
Schlagworte
- Non-destructive testing (2)
- Ultrasonic echo (2)
- 3D-SAFT (1)
- Beton (1)
- Concrete (1)
- Concrete bridge (1)
- Elastodynamic Finite Integration Technique (EFIT) (1)
- Grouting condition (1)
- Impact-echo (1)
- Luftgekoppelter Ultraschall (1)
Since several years ultrasonic imaging techniques are used for testing concrete elements. Combined with a reconstruction calculation they lead to an acoustic imaging of scatterers and reflectors from the inside of the concrete element. For several testing problems it is an advantage to use a two dimensional synthetic aperture and to combine it with a three-dimensional reconstruction calculation (3D-SAFT, Synthetic Aperture Focussing Technique).
This enables the analysis of the tested volume by means of B-scans in two directions and C-scans (projections parallel to the surface), respectively. Using the 2D-scanning technique, especially the disturbing influence of the reinforcing rebars can be minimised.
In this contribution the state of the art of this method is demonstrated and analysed. Examples of the application are presented, concerning
Localisation of honeycombing and compaction faults
Characterisation of cracks (especially measuring the crack depth)
Investigation of tendon ducts
The results presented are obtained in the frame of a research initiative Non-destructive Evaluation of Concrete Structures Using Acoustic and Electromagnetic Echo-Methods supported by the German Science Council (FOR 384 of DFG, Deutsche Forschungsgemeinschaft). The methods are assessed and improved in cooperation with the partners participating in the project.
Ultrasonic Reflection Properties at Interfaces Between Concrete Steel and Air: Imaging and Modelling
(2006)
This paper presents the progress of successful location of grouting faults in tendon ducts with ultrasonic imaging. The examples were obtained in the research group FOR 384 funded by DFG (German Research Foundation). The co-operation of experimental research and modeling allowed imaging and identification of grouted and ungrouted areas of tendon ducts (including strands) in a large test specimen (40 m²). In addition to the criteria for indicating grouting faults in post-tensioned ducts known until now the phase evaluation of reflected ultrasonic pulses is described. Experiments and modeling of wave propagation are presented for reflections at metal plates in concrete (thickness range 0.5 mm to 40 mm) and for tendon ducts including strands.
The main part of the progress was achieved by automated measurements using dry contact transducers, 3D-SAFT reconstruction including phase evaluation and modeling considering wave propagation for typical elastic parameters and exact experimental site conditions. The results for shear waves as well as for pressure waves are compared in the frequency range from 50 kHz to 120 kHz.