Das Bauwesen erfordert sehr hohe Flächenleistungen, so dass der physische Kontakt zur Oberfläche möglichst vermieden werden sollte, um eine hohe Verfahrgeschwindigkeit der Sensoren zu gewährleisten. Andererseits weisen luftgekoppelte, membranbasierte Aktuatoren durch den Impedanzsprung sehr hohe Verluste auf. Daher stellt das schnelle berührungslose Ultraschallmessen immer noch eine ungelöste Herausforderung im Bauwesen dar.
The majority of ultrasonic devices used for non-destructive testing in civil engineering require contact with the surface of the concrete (specimen), which significantly increases the time required for the measurement. This makes it impractical for extensive investigation of large-scale structures such as bridge decks, foundations, or tunnels.
In a pioneering approach, fluidic oscillators are used as contact
free ultrasonic sources to overcome the aforementioned limitations. These robust and cost-effective actuators require only pressurised air and are ideally suited for harsh environments. At a constant supply pressure, they generate a continuous monofrequent actuation signal. Further, varying the supply pressure via a fast pressure regulator was found to generate a frequency modulated signal which enabled time-of-flight measurement with an added advantage of increased signal to noise ratio. To demonstrate the feasibility of this novel idea of non-contact ultrasound, the results of the initial tests are presented.
The majority of ultrasonic devices used for non-
destructive testing in civil engineering require contact with the
surface of the concrete (specimen), which significantly increases
the time required for the measurement. This makes it impractical
for extensive investigation of large-scale structures such as bridge
decks, foundations, or tunnels.
In a pioneering approach, fluidic oscillators are used as contact
free ultrasonic sources to overcome the aforementioned limi-
tations. These robust and cost-effective actuators require only
pressurised air and are ideally suited for harsh environments. At
a constant supply pressure, they generate a continuous mono-
frequent actuation signal. Further, varying the supply pressure
via a fast pressure regulator was found to generate a frequency
modulated signal which enabled time-of-flight measurement with
an added advantage of increased signal to noise ratio. To
demonstrate the feasibility of this novel idea of non-contact
ultrasound, the results of the initial tests are presented.
Das vorliegende Arbeitspapier stellt den Stand des Wissens und der Forschung zum Einsatz von Sensorik in Straßenbefestigungen zur Erfassung von Eingangsgrößen und Merkmalen für die Substanzbewertung zusammenfassend dar. Unter Sensorik versteht dieses Arbeitspapier ganz allgemein technische Einrichtungen, mit denen man die Werte von physikalischen Größen erfassen und zur Interpretation darstellen kann.
The development of prevention methods and the detection of moisture related damages in buildings and transport infrastructure at an early stage are current issues in the field of non-destructive testing in civil engineering.
Especially the subject of partial saturation requires further research since it is more likely to occur than full saturation of the material. In fact, partial saturation in porous media is even more complicated because both fully and partly saturated pores (i.e. pores in which the surfaces are covered with thin water layers) are present.
As the non-destructive method nuclear magnetic resonance (NMR) enables the measurement and quantification of relative low moisture contents, it is suitable for the investigation of partly saturated porous building materials. Nevertheless, the differentiation between partly and fully saturated pores is still a challenge. Therefore, in this study, we investigate two sandstones types (Bozanov and Schönbrunner sandstone) at various defined saturation states by using NMR. Furthermore, we measure the relative humidities within the samples and compute the water layer thicknesses (WLT) along the pore walls of all pore sizes to calculate the corresponding degree of pore saturation. To finally assign the NMR signals to pore sizes and to differentiate between partly and fully saturated pores, the water content distribution obtained from the WLT calculation is used for calibration of the relaxation-time distribution. In this extended abstract, selected results only for Schönbrunner sandstone are presented.
While contact and immersion ultrasonic testing are established methods in non-destructive testing (NDT), generating high power air-coupled ultrasound remains a challenging task. Solutions often involve setups that are restricted to lab environments. When field measurements are required, such as in NDT for civil engineering, a handy, robust and safe transducer is needed. For this purpose, an ultrasonic transducer based on a fluidic switch has been developed. A sonic air flow inside the device is switched rapidly so that an ultrasonic signal is generated. Both theory and previous flow simulations suggest that the control flow pressure ramp has only little influence on the switching time of the device. This publication gives an overview over the operating principle of the fluidic ultrasonic transducer and investigates the influence of control tube length and pulsing repetition rate on the ultrasonic pressure amplitude. High repetition rates are found to reduce the signal amplitude, whereas long tubing has only little negative influence on the amplitude while improving signal quality.
Ultrasonic measurement technology has become indispensable in NDT-CE. Air-coupled ultrasonic (ACU) measurement techniques promise to reduce measurement time. However, the signal quality suffers from large specific impedance mismatch at the transducer-air and air-specimen interface. Additionally, large pressure amplitudes are necessary for the penetration depth required in NDT-CE applications. To address the specific requirements of ultrasonic testing in NDT-CE, a robust ACU transducer was developed, that generates ultrasound by quickly switching a pressurized air flow. The simple design of the fluidic transducer makes the device maintenance free and resilient against harsh environmental conditions. Since the signal is generated by aeroacoustics, there is no specific impedance mismatch between the transducer and the surrounding air. The ultrasonic signal exhibits frequencies in the 30-60 kHz range and is therefore well suited to penetrate heterogenous materials such as concrete. This contribution gives an introduction in the working principle and signal characteristics of the fluidic transducer. Its applicability to measurements in concrete is verified. A detailed outlook is given to discuss the future potential of fluidic ultrasonic actuators.
Ultrasonic measurement technology has become indispensable in NDT-CE. Air-coupled ultrasonic (ACU) measurement techniques promise to reduce measurement time. However, the signal quality suffers from large specific impedance mismatch at the transducer-air and air-specimen interface. Additionally, large pressure amplitudes are necessary for the penetration depth required in NDT-CE applications.
To address the specific requirements of ultrasonic testing in NDT-CE, a robust ACU transducer was developed, that generates ultrasound by quickly switching a pressurized air flow. The simple design of the fluidic transducer makes the device maintenance free and resilient against harsh environmental conditions. Since the signal is generated by aeroacoustics, there is no specific impedance mismatch between the transducer and the surrounding air. The ultrasonic signal exhibits frequencies in the 30-60 kHz range and is therefore well suited to penetrate heterogenous materials such as concrete. This contribution gives an introduction in the working principle and signal characteristics of the fluidic transducer. A detailed outlook is given to discuss the future potential of fluidic ultrasonic actuators.
Several countries, which use or used nuclear power, started to destruct nuclear power plants. Thus, large amounts of radioactive waste have to be stored safely during the next decades. Large underground caverns will
be used a nuclear waste disposal. Once the cavern is full, a sealing construction is required. The sealing should avoid the contact to any fluids or substances of the storage barrels and reduce hazardous radiation.