Filtern
Dokumenttyp
- Zeitschriftenartikel (6)
- Vortrag (4)
- Posterpräsentation (2)
- Beitrag zu einem Tagungsband (1)
Schlagworte
- Acoustic levitation (2)
- Ambient mass spectrometry (2)
- Levitated droplets (2)
- Mass spectrometry (2)
- AP-MALDI (1)
- Air (1)
- Airbrush (1)
- Atmospheric-pressure (1)
- DPSS laser (1)
- Dielectric barrier discharge (1)
Eingeladener Vortrag
- nein (4)
A commercially available airbrush gun as a new source for spray ionization is presented. It is best operated employing moderate stagnation pressures, resulting in a sonic gas flow. A mass spectrometric investigation on the amino acid lysine and several peptides reveals that this inexpensive approach results in reproducible mass spectra. The ion patterns strongly resemble the results from other studies obtained with custom made sonic spray vaporizers. The patterns as well resemble the mass spectra recorded with electrospray devices. For a better understanding of the vaporization process, the mass spectrometry experiments are accompanied by laser induced fluorescence experiments. Inverse Abel transform of the obtained fluorescence maps allows the determination of the full 3D distribution of the spray cone. Furthermore, via exploitation of the solvatochromism of the used dye the solvation state distribution can be visualized. In addition, expansion parameters like droplet size and velocity are obtained by laser stroboscopy. The experiments demonstrate that the analyte is hardly desolvated throughout the expansion. This indicates a subsequent vaporization of the residual solvent in the intermediate pressure region of the mass spectrometer.
Characterization of Pressure Field Distribution for an Optimization of Ultrasonic Levitatiors
(2013)
For many analytical purposes, direct laser ionization of liquids is desirable. Several studies on supported droplets, free liquid jets, and ballistically dispensed microdroplets have been conducted, yet detailed knowledge of the underlying mechanistics in ion formation is still missing. This contribution introduces a simple combination of IR-MALDI mass spectrometry and an acoustical levitation device for contactless confinement of the liquid sample. The homebuilt ultrasonic levitator supports droplets of several millimeters in diameter. These droplets are vaporized by a carbon dioxide laser in the vicinity of the atmospheric pressure interface of a time of flight mass spectrometer. The evaporation process is studied by high repetition rate shadowgraphy experiments elucidating the ballistic evaporation of the sample and revealing strong confinement of the vapor by the ultrasonic field of the trap. Finally, typical mass spectra for pure glycerol/water matrix and lysine as an analyte are presented with and without the addition of trifluoracetic acid, and the ionization mechanism is briefly discussed. The technique is a promising candidate for a reproducible mass spectrometric detection scheme for the field of microfluidics.
A novel method for predictions of the sound pressure distribution in acoustic levitators is based on a matrix representation of the Rayleigh integral. This method allows for a fast calculation of the acoustic field within the resonator. To make sure that the underlying assumptions and simplifications are justified, this approach was tested by a direct comparison to experimental data. The experimental sound pressure distributions were recorded by high spatially resolved frequency selective microphone scanning. To emphasize the general applicability of the two approaches, the comparative studies were conducted for four different resonator geometries. In all cases, the results show an excellent agreement, demonstrating the accuracy of the matrix method.
One major drawback of matrix-assisted laser desorption/ionization (MALDI) is still the relatively poor pulse-to-pulse reproducibility of the signal intensity. This problem, caused by insufficient homogeneity in the matrix/analyte co-crystallization, is usually circumvented by averaging the detected ion intensity over several shots. However, during the consecutive laser pulses, the applied matrix gets depleted and only a number of subsequent experiments can be done on the same sample spot. In order to achieve the desired long-term stability in combination with a sufficient pulse-to-pulse reproducibility, recently liquid MALDI matrices have been introduced. This contribution demonstrates the promising combination of liquid matrices with high repetition rate lasers for atmospheric pressure MALDI (AP-MALDI). To demonstrate the robustness of the new approach, two different kinds of liquid matrices were used in combination with both a typical flashlamp pumped 15 Hz laser and a diode pumped solid state laser operated at 5 kHz. The latter showed a stable ion signal over more than 3,500,000 consecutive laser pulses.