This paper presents a numerical and an experimental procedure to obtain the pressure field in single-axis acoustic levitators. Numerically, the pressure field is determined by a matrix method based on the Rayleigh integral that take into account the multiple wave reflections that occur between the transducer and the reflector. The numerical pressure field is compared with the acoustic pressure measured by an earplug microphone, that is connected to a hollow needle. The tip of the needle is moved by a µm translation stage through the field and the signal is recorded using a lock-in amplifier locked to the levitator frequency. The pressure field obtained numerically show good agreement with that obtained experimentally.
One major drawback of matrix-assisted laser desorption/ionization (MALDI) is still the relatively poor pulse-to-pulse reproducibility of the signal intensity. This problem, caused by insufficient homogeneity in the matrix/analyte co-crystallization, is usually circumvented by averaging the detected ion intensity over several shots. However, during the consecutive laser pulses, the applied matrix gets depleted and only a number of subsequent experiments can be done on the same sample spot. In order to achieve the desired long-term stability in combination with a sufficient pulse-to-pulse reproducibility, recently liquid MALDI matrices have been introduced. This contribution demonstrates the promising combination of liquid matrices with high repetition rate lasers for atmospheric pressure MALDI (AP-MALDI). To demonstrate the robustness of the new approach, two different kinds of liquid matrices were used in combination with both a typical flashlamp pumped 15 Hz laser and a diode pumped solid state laser operated at 5 kHz. The latter showed a stable ion signal over more than 3,500,000 consecutive laser pulses.
New-found interest in the development of ionization sources for mass spectrometry, inspired by the advent of ambient desorption/ionization mass spectrometry, has led to a resurgence in plasma-source development and characterization. Dielectric-barrier discharges, particularly the low-temperature plasma (LTP) probe format, have been at the forefront of this field due to their low power consumption and relatively simple design. However, better fundamental understanding of this desorption/ionization source is needed to improve the analytical capabilities of such a device. Here, we use relatively fast (2.5 ms per spectrum) time-resolved mass spectrometry to characterize the temporal reagent-ion distribution from a low-frequency LTP probe. Different voltage waveforms were found to heavily influence the discharge properties and, consequently, ion production. Ion signals from short discharge pulses, ca. 40 µs, were found to be significantly broadened, ca. 10 ms, prior to extraction into the mass spectrometer. Additionally, higher frequencies of a sine-wave LTP produced the largest flux of reagent ions, which existed for most of the voltage waveforms. Finally, temporal signals for reagent and analyte ions were measured and related to specific ionization processes: proton transfer and charge transfer.
Characterization of Pressure Field Distribution for an Optimization of Ultrasonic Levitatiors
(2013)
A novel method for predictions of the sound pressure distribution in acoustic levitators is based on a matrix representation of the Rayleigh integral. This method allows for a fast calculation of the acoustic field within the resonator. To make sure that the underlying assumptions and simplifications are justified, this approach was tested by a direct comparison to experimental data. The experimental sound pressure distributions were recorded by high spatially resolved frequency selective microphone scanning. To emphasize the general applicability of the two approaches, the comparative studies were conducted for four different resonator geometries. In all cases, the results show an excellent agreement, demonstrating the accuracy of the matrix method.