Die mechanische Spannung ist ein maßgeblicher Parameter ferromagnetischer Materialien. Wird ein solches Material unter die Curie Temperatur abgekühlt, zerfällt es spontan in nahezu selbstgesättigte magnetische Domänen. Diese Magnetisierung führt gleichzeitig zu einer Verformung der mit ihr gekoppelten Kristallgitter. Ein Effekt der auch reziprok gilt: wird die Gitterverformung durch eine Spannung behindert ändert sich zwangsweise der magnetische Zustand.
Man kann annehmen, dass zwischen unterschiedlichen, für sich aber homogen verspannten Werkstoffbereichen, lokale magnetische Streufelder auftreten, weil magneto-mechanische Effekte eine Inkompatibilität der Domänenstruktur induzieren. Bekanntlich bilden sich Spannungsgradienten nach Schweißprozessen durch ungleichmäßigen Wärmeeintrag, thermischer Dehnung, und unterschiedlichen Abkühlraten aus.
Unter dieser Prämisse untersuchen wir Wolfram-Inertgas geschweißte Blindnahtproben (250x100x4,8 mm^3) aus einem hypereutektoiden Baustahl.
Der Spannungszustand der Proben wurde anhand von Neutronendiffraktometrie (ND) am Instrument E3 am Reaktor BERII (Helmholzzentrum Berlin, HZB) charakterisiert. ND ist ein Referenzverfahren für die quantitative Bestimmung von elastischen Dehnungen in kristallinen Materialien, deren Gitter selbst der Messmaßstab ist. Die Auswertung zeigt hohe Längsspannungen mit lokalen Maxima in Größenordnung von 600 MPa, die von umgebenen Druckspannungszonen kompensiert werden.
Zur Detektion der magnetischen Kleinststreufelder verwenden wir speziell designte GMR-Sensorik (GMR - Giant Magneto Resistance), die aufgrund der geringen Größe ihrer aktiven Sensorelemente hohe Ortsauflösung mit Sensitivität vereint. Die Visualisierung der Messergebnisse lässt eine klare magnetische Mikrostruktur der Schweißnähte erkennen, in der die Streufelder lateral in Größenordnung des Erdmagnetfeldes variieren (~50 µT).
Wir zeigen durch einen Vergleich beider Messverfahren, dass lokale magnetische Streufeldmaxima in hohem Maße mit den Spannungsgradienten übereinstimmen.
Die mechanische Spannung ist ein maßgeblicher Parameter ferromagnetischer Materialien. Wird ein solches Material unter die Curie Temperatur abgekühlt, zerfällt es spontan in nahezu selbstgesättigte magnetische Domänen. Diese Magnetisierung führt gleichzeitig zu einer Verformung der mit ihr gekoppelten Kristallgitter. Ein Effekt der auch reziprok gilt: wird die Gitterverformung durch eine Spannung behindert ändert sich zwangsweise der magnetische Zustand.
Man kann annehmen, dass zwischen unterschiedlichen, für sich aber homogen verspannten Werkstoffbereichen, lokale magnetische Streufelder auftreten, weil magneto-mechanische Effekte eine Inkompatibilität der Domänenstruktur induzieren. Bekanntlich bilden sich Spannungsgradienten nach Schweißprozessen durch ungleichmäßigen Wärmeeintrag, thermischer Dehnung, und unterschiedlichen Abkühlraten aus.
Unter dieser Prämisse untersuchen wir Wolfram-Inertgas geschweißte Blindnahtproben (250x100x4,8 mm^3) aus einem hypereutektoiden Baustahl.
Der Spannungszustand der Proben wurde anhand von Neutronendiffraktometrie (ND) am Instrument E3 am Reaktor BERII (Helmholzzentrum Berlin, HZB) charakterisiert. ND ist ein Referenzverfahren für die quantitative Bestimmung von elastischen Dehnungen in kristallinen Materialien, deren Gitter selbst der Messmaßstab ist. Die Auswertung zeigt hohe Längsspannungen mit lokalen Maxima in Größenordnung von 600 MPa, die von umgebenen Druckspannungszonen kompensiert werden.
Zur Detektion der magnetischen Kleinststreufelder verwenden wir speziell designte GMR-Sensorik (GMR - Giant Magneto Resistance), die aufgrund der geringen Größe ihrer aktiven Sensorelemente hohe Ortsauflösung mit Sensitivität vereint. Die Visualisierung der Messergebnisse lässt eine klare magnetische Mikrostruktur der Schweißnähte erkennen, in der die Streufelder lateral in Größenordnung des Erdmagnetfeldes variieren (~50 µT).
Wir zeigen durch einen Vergleich beider Messverfahren, dass lokale magnetische Streufeldmaxima in hohem Maße mit den Spannungsgradienten übereinstimmen.
Die Mikrostruktur ferromagnetischer Materialien hat einen maßgeblichen Einfluss auf deren magnetischen Eigenschaften. Gerade bei niedrigen Feldstärken zeigen sich Parameter wie Koerzitivität, Permeabilität und Verlustleistung hoch sensitiv.
Wir zeigen am Beispiel des unlegierten Baustahls S235JR, dass die magnetische Mikrostruktur an der Probenoberfläche in hohem Maße mit inhomogenen Dehnungen übereinstimmt. Zur Detektion der Kleinststreufelder verwenden wir speziell designte GMR Sensorik, die Sensitivität (3mV/V/kA/m) mit hoher Ortsauflösung (180 µm) vereint. Infolgedessen können wir auf eine aktive magnetische Anregung verzichten. Wir nutzen allein die sich durch magneto-mechanische Prozesse ausbildende „spontane“ magnetische Mikrostruktur des Materials.
Das hervorragende Signal-Rausch-Verhältnis unserer GMR-Sensorik für inhomogene Streufelder erlaubt, schon geringe und lokal abgegrenzte plastische Deformationen in Form und Position reproduzierbar zu visualisieren. Die zugehörigen Signale zeigen die typische Sequenz von erhöhten positiven und negativen Normalkomponenten wie sie bei einer Rissanzeige der aktiven Streuflussprüfung (MFL - Magnetic Flux Leakage) beobachtet wird. Magnetisch kann eine plastische Zone daher als Vorstufe eines Risses betrachtet werden, deren relative Permeabilität für den Riss als Grenzfall zu μr = 1 tendiert.
This study examines the relationship between the magnetic mesostructure with the microstructure of low carbon steel tungsten inert gas welds. Optical microscopy revealed variation in the microstructure of the parent material, in the heat affected and fusion zones, correlating with distinctive changes in the local magnetic stray fields measured with high spatial resolution giant magneto resistance sensors. In the vicinity of the heat affected zone high residual stresses were found using neutron diffraction.
Notably, the gradients of von Mises stress and triaxial magnetic stray field modulus follow the same tendency transverse to the weld. In contrast, micro-X-ray fluorescence characterization indicated that local changes in element composition had no independent effect on magnetic stray fields.
Giant magneto-resistive (GMR) sensor based metal magnetic memory (MMM) technique is proposed for mapping of deformation-induced self-magnetic leakage fields (SMLFs) in carbon steel. The specimens were subjected to different amounts of tensile deformation and the deformation-induced SMLFs were measured using a GMR sensor after unloading the specimens. 3D-nonlinear finite element modeling was performed to predict stress–strain state in a steel specimen under tensile load. The experimentally obtained SMLF images were correlated with the finite element model predicted stress–strain states. Studies reveal that the MMM technique can detect the plastic deformation with signal-to-noise ratio better than 20 dB. The technique enables the mapping of plastic deformation in carbon steels for the evaluation of the severity of deformation. The study also reveals that deformation-induced SMLF is influenced by the presence of initial surface residual stress, introduced by shot peening. The intensity of SMLF signal is found to increase with increase in tensile load and decrease with shot peening.
It is widely accepted that the magnetic state of a ferromagnetic material may be irreversibly altered by mechanical loading due to magnetoelastic effects. A novel standardized nondestructive testing (NDT) technique uses weak magnetic stray fields, which are assumed to arise from inhomogeneous deformation, for structural health monitoring (i.e., for detection and assessment of damage). However, the mechanical and microstructural complexity of damage has hitherto only been insufficiently considered. The aim of this study is to discuss the phenomenon of inhomogeneous “self-magnetization” of a polycrystalline ferromagnetic material under inhomogeneous deformation experimentally and with stronger material-mechanical focus. To this end, notched specimens were elastically and plastically deformed. Surface magnetic states were measured by a three-axis giant magnetoresistant (GMR) sensor and were compared with strain field (digital image correlation) and optical topography measurements. It is demonstrated that the stray fields do not solely form due to magnetoelastic effects. Instead, inhomogeneous plastic deformation causes topography, which is one of the main origins for the magnetic stray field formation. Additionally, if not considered, topography may falsify the magnetic signals due to variable lift-off values. The correlation of magnetic vector components with mechanical tensors, particularly for multiaxial stress/strain states and inhomogeneous elastic-plastic deformations remains an issue.
Magneto resistance sensors like GMR (giant magneto resistance) or TMR (tunnel magneto resistance) are widely used in industrial applications, examples are position measurement and read heads of hard disk drives. However, in case of non-destructive testing (NDT) applications these sensors, although their properties are outstanding like high spatial resolution, high field sensitivity, low cost and low energy consumption, never reached a technical transfer to an application beyond sci-entific scope.
This paper deals with benefits of GMR/TMR sensors in terms of high spatial resolution testing for different NDT applica-tions. The first example demonstrates the preeminent advantages of MR-elements compared with conventional coils used in eddy current testing (ET). The probe comprises one-wire excitation with an array of MR elements. This led to a better spatial resolution in terms of neighboring defects.
The second section concentrates on MFL-testing (magnetic flux leakage) with active field excitation during and before test-ing. The latter illustrated the capability of highly resolved crack detection of a crossed notch. This example is best suited to show the ability of tiny magnetic field sensors for magnetic material characterization of a sample surface. Another example is based on characterization of samples after tensile test. Here, no external field is applied. The magnetization is only changed due to external load and magnetostriction leading to a field signature which GMR sensors can resolve. This gives access to internal changes of the magnetization state of the sample under test.
Magnetic testing methods are frequently applied in non-destructive evaluation of ferromagnetic materials. In the past decade, metal magnetic memory (MMM) technique according to ISO 24497 is gaining considerable interest in the magnetic NDT community. In contrast to traditional Magnetic Flux Leakage (MFL) testing, the inspection objects are not intentionally magnetized by an external magnetic field. Due to physical coupling between mechanical stress and magnetization in ferromagnetic materials, it is assumed that the distribution of the “natural” MFL (self-magnetic-leakage field, SMLF) indicate zones of different remanent magnetization, which in turn, correspond to the internal stress of specimen or in the most general sense to material degradation.
Usually, MMM measurements are performed by relatively bulky magnetic inspection sensors providing a spatial resolution in millimetre range. High precision GMR (Giant Magneto Resistance) measurements in the micrometer regime along with image based representation and evaluation can provide a higher degree of information. We present a concise summary of a broader research project aimed at studying the correlation of magnetic structure and microstructure of steels. Particularly, we compare residual stress measurements in S235JR steel by means of neutron diffraction with high resolution magnetic field measurements. In addition, we discuss the influence of deformation-induced magnetization in plastically deformed specimens with and without notches due to various quasi-static and cyclic load levels. Furthermore, comparative measurements with common non-destructive testing methods are presented.
Despite of a quantitative evaluation of material degradation, the in the field inspection by MMM remains problematic due to substantial influences on such as external magnetization, anisotropy of internal magnetization and material degradation, as well as geometry and surface effects of the inspection objects on SMFL signals. The prospects and restrictions of the MMM technique are discussed in this contribution.
Evaluation of high spatial resolution imaging of magnetic stray fields for early damage detection
(2017)
The paper discusses the evaluation of elastic and plastic strain states in two low-carbon steels of the same steel group with high spatial resolution GMR (giant magneto resistance) sensors. The residual stress distributions of tungsten inert gas welded plates were determined by means of neutron diffraction as a reference. The normal component of local residual magnetic stray fields arise in the vicinity of the positions of maximum stress. The experiments performed on flat tensile specimen indicate that the boundaries of plastic deformations are a source of stray fields. The spatial variations of magnetic stray fields for both the weld and the tensile samples are in the order of the earths magnetic field.
Magneto resistive (MR) sensors are suited for a wide range of different applications. Especially due to their small sizes and their frequency-independent behaviour, they are eligible candidates for non-destructive testing methods where high spatial resolution is required. The use of specialized magnetic field probes enables not only a defect evaluation, but also a localized characterization of ferromagnetic materials.
This paper presents some NDT (non-destructive testing) examples concerning magnetic flux leakage applications (MFL) and eddy current testing (ET). For MFL-testing we used an NDT-adapted GMR (Giant MR) sensor array for the detection of small inclusions in thin steel sheets. We also investigated the effects of microstructure on magnetic properties using GMR sensors. The ET-example describes an MR array probe consisting of 32 MR-elements, an ASIC, subsequent readout components and a one-wire excitation to generate eddy currents inside the material (developed in the EU-funded IMAGIC-project, 2011-2014, 7th Framework Programme). Using this MR-probe we achieved results with a better spatial resolved defect detection of neighbouring boreholes compared to “conventional” ET-probes.