Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (20)
- Beitrag zu einem Tagungsband (19)
- Vortrag (16)
- Beitrag zu einem Sammelband (7)
- Posterpräsentation (4)
- Sonstiges (3)
- Buchkapitel (2)
Schlagworte
- Computertomographie (8)
- Computed tomography (5)
- X-ray refraction (4)
- CT (3)
- Pore orientation (3)
- Porous ceramics (3)
- Archäologie (2)
- Computed Tomography (2)
- Concrete (2)
- Coordinate metrology (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (16)
Bi-continuous porous ceramics for filtration applications possess a particularly complicated microstructure, whereby porosity and solid matter are intermingled. Mechanical, thermal, and filtration properties can only be precisely estimated if the morphology of both solid matter and porosity can be quantitatively determined. Using 3D computed tomography (CT) at different resolutions, and several X-ray refraction-based techniques, we quantitatively evaluated porosity and pore orientation in cordierite diesel particulate filter ceramics.Moreover, applying both Fast Fourier Transform (FFT) and a newly developed image analysis algorithm (directional interface variance analysis, DIVA), we quantitatively evaluated porosity and pore orientation. Both the experimental techniques and the statistical approach allow extraction of spatially resolved or average values.Porosity values from synchrotron computed tomography used turn out to agree with mercury intrusion measurements, while pore orientation factors agree with published crystallographic texture data. This latter point also implies that the study of the pore/matter interface is sufficient to describe the morphological properties of these materials.
This poster presentation gives an overview of the great potential of X-ray micro computed tomography (CT) to cast light on the evolution of the microstructure in construction materials. Prevention of damage is of major economic and social importance in the development of suitable construction materials such as concrete and asphalt. Therefore a non-destructive testing method such as CT is an appropriate tool for visualization of the inner structure. Its combination with other test methods allows understanding the damage processes such as crack propagation or corrosion. We show examples of internal structure analyses on a wide range of materials: Automatic 3D crack detection and the visualization of corrosion products inside of steel reinforced concrete, pore and shape analysis of lightweight aggregates and the visualization of deformation of high-pressure loaded aerated concrete specimens, distribution of aggregates inside concrete, and determination of the surface of porous asphalt core samples. Segmented structures serve, e.g., as input data for simulation of transport phenomena or virtual load tests.
We present a modified aluminium casting which is especially suited as test piece for measuring casting defects and the geometry by means of cone-beam micro-focus X-ray systems, and which may become a reference standard for dimensional measurements and defect detection.
To obtain a test piece with inner geometries measured by tactile means, we divided a small aluminium cylinder head into four pieces in such a way that most inner surfaces can be reached with a tactile probe. Reference geometries (spheres and cylinders) were applied to define a coordinate system for aligning the measurements in the disassembled and re-assembled state. The four pieces were re-assembled after the tactile measurement.
The test piece also contains casting defects. In order to be able to use the assembled cylinder head as reference sample for defect detection, measurements with higher spatial resolution and better signal-to-noise ratio were performed on the single parts. For improving the reliability of the reference measurements, CT measurements of each part were carried out in three different orientations, and the individual defect detections were combined to obtain a reference data set with a high probability of defect detection and a low rate of erroneous detections.
A new method for comparing the defect detection in a CT measurement to a reference data set is demonstrated, which provides individual information on every detected flaw.
We discuss the results of measurements in the assembled state with respect to the reference data for flaw detection.
The Bronze Age site in the Tollense valley, Germany, has yielded thousands of human and animal bones and a number of archaeological artifacts. Several of the human bones exhibit blunt and sharp force lesions, and the assemblage has been interpreted as representing victims of a large scale conflict. One of the earliest finds is a human humerus with an embedded flint arrowhead. Alleged signs of healing initially reported for this humerus based on clinical CT imaging were interpreted as evidence of an antemortem lesion. The present study, using micro-CT imaging, revealed that the arrowhead lesion in the humerus, contrary to the previous interpretation, shows no signs of healing. The structure previously assumed to represent a sclerotic margin around the wound canal was shown to actually represent compacted trabecular debris. Thus, our re-analysis of the specimen led to a re-classification of the arrow wound as a perimortem lesion. The findings of the present study demonstrate the value of micro-CT imaging as a non-destructive method for obtaining information on the nature of bone lesions and healing reactions critical for the reconstruction of interpersonal conflict scenarios in the past.
Die Computertomographie (CT) ist in der Medizin als Standardtechnik etabliert, in der zerstörungsfreien Prüfung wird sie zunehmend angewendet, in einzelnen Fällen sogar als Referenzverfahren eingesetzt. Gegenwärtig ist eine starke Zunahme von Anwendungen der CT in der Materialcharakterisierung zu verzeichnen. Zudem werden weitere moderne 3D-Techniken für werkstoffwissenschaftliche Fragestellungen genutzt, um die Mikrostruktur - auch in situ (z.B. Druck, Temperatur) - aufzuklären. Hier werden neben der konventionellen Absorptions-CT auch die Potenziale der Refraktions-CT zur Beantwortung prozesstechnischer sowie werkstofflicher Fragestellungen aufgezeigt, die ein „ganzheitliches Bild“ des jeweiligen Werkstoffs zum Ziel haben.
Subject of this investigation is the in-situ evolution of pore volume and pore size distribution in Ytong (a porous concrete material) under increasing pressure with two different non-destructive analytical methods: Nuclear Magnetic Resonance (NMR) and X-ray Computed Tomography (CT). For both methods special strain devices to apply external pressure were constructed. The results from the two techniques yield complementary information on the pore size distribution and allows covering different pore size regions.
Most knowledge about the structure, function, and evolution of early compound eyes is based on investigations in trilobites. However, these studies dealt mainly with the cuticular lenses and little was known about internal anatomy. Only recently some data on crystalline cones and retinula cells were reported for a Cambrian trilobite species. Here, we describe internal eye structures of two other trilobite genera. The Ordovician Asaphus sp. reveals preserved crystalline cones situated underneath the cuticular lenses. The same is true for the Devonian species Archegonus (Waribole) warsteinensis, which in addition shows the fine structure of the rhabdom in the retinula cells. These results suggest that an apposition eye with a crystalline cone is ancestral for Trilobita. The overall similarity of trilobite eyes to those of myriapods, crustaceans, and hexapods corroborates views of a phylogenetic position of trilobites in the stem lineage of Mandibulata.
Numerical measurement uncertainty determination for dimensional measurements of microparts with CT
(2016)
Up to now, the only standardized method to determine the measurement uncertainty for computed tomography (CT) is to use calibrated workpieces as specified in the Guideline VDI/VDE 2630 Part 2.1. This paper discusses a promising numerical method for uncertainty determination with help of a virtual metrological CT (VMCT). It gives an explanation of the adjustments, the input parameters and the execution of the simulation. Furthermore, it discusses the first results of uncertainty determination compared to the method of using calibrated workpieces with the aid of two example cases.
In this paper we present the results of imaging studies of ancient Egyptian metallic artifacts using micro-Computed Tomography (micro-CT). Micro-CT is a non-destructive imaging method with high spatial resolution, which enables the examination of the internal structure of objects. It is thus especially suitable for the investigation of cultural heritage and archaeological findings, when it is not possible to sample or difficult to manipulate the object. Using specialized software for 3D visualization and segmentation, data sets of two objects were analyzed. We gained a clear view of the inner structure of a metallic archaeological artifact from the necropolis of Abusir el-Meleq, which is believed to be very ancient in the Egyptian archaeological context (from the Predynastic Era), and were able to distinguish its different omponents under the thick layers of external concretions. These components give hints about the production technology of the object. We also investigated the contents of a closed metal box found near Abusir dated to the Late/Greco-Roman Period. The identified Content corresponds either to sediments or to mineral remains of the original content of the box. Both artifacts are from excavations conducted in Egypt and are part of the archeological collection of the Ägyptisches Museum und Papyrussammlung in Berlin.
Most knowledge about the structure, function, and evolution of early compound eyes is based on investigations in trilobites. However, these studies dealt mainly with the cuticular lenses and little was known about internal anatomy. Only recently some data on crystalline cones and retinula cells were reported for a Cambrian trilobite species. Here, we describe internal eye structures of two other trilobite genera. The Ordovician Asaphus sp. reveals preserved crystalline cones situated underneath the cuticular lenses. The same is true for the Devonian species Archegonus (Waribole) warsteinensis, which in addition shows the fine structure of the rhabdom in the retinula cells. These results suggest that an apposition eye with a crystalline cone is ancestral for Trilobita. The overall similarity of trilobite eyes to those of myriapods, crustaceans, and hexapods corroborates views of a phylogenetic position of trilobites in the stem lineage of Mandibulata.
In order to investigate their microcracking behaviour, the microstructures of several β-eucryptite ceramics, obtained from glass precursor and cerammed to yield different grain sizes and microcrack densities, were characterized by laboratory and synchrotron x-ray refraction and tomography. Results were compared with those obtained from scanning electron microscopy (SEM). In SEM images, the characterized materials appeared fully dense but computed tomography showed the presence of pore clusters. Uniaxial tensile testing was performed on specimens while strain maps were recorded and analyzed by Digital Image Correlation (DIC). X-ray refraction techniques were applied on specimens before and after tensile testing to measure the amount of the internal specific surface (i.e., area per unit volume). X-ray refraction revealed that (a) the small grain size (SGS) material contained a large specific surface, originating from the grain boundaries and the interfaces of TiO2 precipitates; (b) the medium (MGS) and large grain size (LGS) materials possessed higher amounts of specific surface compared to SGS material due to microcracks, which decreased after tensile loading; (c) the precursor glass had negligible internal surface. The unexpected decrease in the internal surface of MGS and LGS after tensile testing is explained by the presence of compressive regions in the DIC strain maps and further by theoretical arguments. It is suggested that while some microcracks merge via propagation, more close mechanically, thereby explaining the observed X-ray refraction results. The mechanisms proposed would allow the development of a strain hardening route in ceramics.