Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (20)
- Beitrag zu einem Tagungsband (19)
- Vortrag (16)
- Beitrag zu einem Sammelband (7)
- Posterpräsentation (4)
- Sonstiges (3)
- Buchkapitel (2)
Schlagworte
- Computertomographie (8)
- Computed tomography (5)
- X-ray refraction (4)
- CT (3)
- Pore orientation (3)
- Porous ceramics (3)
- Archäologie (2)
- Computed Tomography (2)
- Concrete (2)
- Coordinate metrology (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (16)
Ceramic parts possessing an ordered porosity were produced for the first time by powder-based three-dimensional printing of a preceramic polymer followed by pyrolysis in an inert atmosphere. The main parameters involved in the process were investigated, and the precision of the printed and ceramized parts was assessed by means of scanning electron microscopy and micro computed tomography. The influence of two different printing solvents was investigated and the use of a mixture of 1-hexanol and hexylacetate in particular allowed the production of parts with a relative density of 80% both in the polymeric and in the ceramic state. The mixing of a cross-linking catalyst directly with the printing liquid greatly simplified the process, minimizing the necessity of preprocessing the starting powder. Three-dimensional printing of a preceramic polymer not containing any inert or active fillers was proved to be a feasible, convenient and precise process for the production of porous ceramic possessing a complex, ordered structure, such as stretch-dominated lattices.
Die Produktion von elektronischen, optischen und elektro-mechanischen Mikro- und Nanosystemen stellt hohe Anforderungen an die Messtechnik, um die Fertigungsprozesse zu optimieren und die Qualität zu prüfen. Existierende Messverfahren unterliegen Beschränkungen hinsichtlich des Auflösungsvermögens, der Messfeldgröße und des Ergebnisses der Messung. Der kombinierte Einsatz von Sensoren mit unterschiedlichen Fähigkeiten in den Auflösungsstufen mittels einer intelligenten Messstrategie ermöglicht eine effiziente Prüfung.
Neben den geeigneten Prüfstrategien werden auch Methoden zur Fusion und Auswertung der Daten von Sensoren mit unterschiedlichen Auflösungsfähigkeiten benötigt. Datenfusion bezeichnet dabei das Zusammenfügen verschiedener Messungen, um entweder unterschiedliche Eigenschaften eines Messobjekts in einem gemeinsamen Koordinatensystem angeben zu können oder um aus verschiedenen Messungen derselben Eigenschaft des Messobjekts einen Datensatz von höherer Qualität gegenüber den einzelnen Datensätzen zu erhalten. Voraussetzung für die Datenfusion ist Registrierung, die eine Überführung von Messdaten unterschiedlicher Messfelder oder Messmittel in ein gemeinsames Koordinatensystem darstellt und Thema dieses Beitrages ist.
The Final Gravettian level (level 2) of the abri Pataud (Dordogne, France) yielded a large assemblage of body ornaments that consists essentially of 85 quite standardized rectangular beads. Some uncertainty remained about the raw material in which these small beads were made: mammoth ivory, reindeer antler or bone? Non-invasive methods were employed in order to determine the raw material. First chemical analyses using microbeam Proton Induced X-ray Emission analysis (microPIXE) did not enable us to conclude definitively. Therefore, synchrotron and laboratory X-ray microtomography (microCT) were applied on eight beads and allowed us to identify ivory for all of them except for one, which shows slightly different morphological features.
Most knowledge about the structure, function, and evolution of early compound eyes is based on investigations in trilobites. However, these studies dealt mainly with the cuticular lenses and little was known about internal anatomy. Only recently some data on crystalline cones and retinula cells were reported for a Cambrian trilobite species. Here, we describe internal eye structures of two other trilobite genera. The Ordovician Asaphus sp. reveals preserved crystalline cones situated underneath the cuticular lenses. The same is true for the Devonian species Archegonus (Waribole) warsteinensis, which in addition shows the fine structure of the rhabdom in the retinula cells. These results suggest that an apposition eye with a crystalline cone is ancestral for Trilobita. The overall similarity of trilobite eyes to those of myriapods, crustaceans, and hexapods corroborates views of a phylogenetic position of trilobites in the stem lineage of Mandibulata.
Ein dreidimensionaler Prüfkörper für die Lunkererkennung in Gussteilen mittels Computertomographie
(2010)
The effects of refraction (phase-contrast) are normally considered as disturbances in high-resolution μCT-measurements. We show that in the case of small objects with low absorption a single-distance phase-retrieval algorithm not only reduces the edge enhancement, but also raises the signal-to-noise ratio sufficiently to allow dimensional measurements. This is exemplified at an optical element for optical fibre connectors.
Methode und Prüfkörper zum Nachweis von Gussdefekten in Aluminiumbauteilen mit Computertomographie
(2009)
We present a modified aluminium casting which is especially suited as test piece for measuring casting defects and the geometry by means of cone-beam micro-focus X-ray systems, and which may become a reference standard for dimensional measurements and defect detection.
To obtain a test piece with inner geometries measured by tactile means, we divided a small aluminium cylinder head into four pieces in such a way that most inner surfaces can be reached with a tactile probe. Reference geometries (spheres and cylinders) were applied to define a coordinate system for aligning the measurements in the disassembled and re-assembled state. The four pieces were re-assembled after the tactile measurement.
The test piece also contains casting defects. In order to be able to use the assembled cylinder head as reference sample for defect detection, measurements with higher spatial resolution and better signal-to-noise ratio were performed on the single parts. For improving the reliability of the reference measurements, CT measurements of each part were carried out in three different orientations, and the individual defect detections were combined to obtain a reference data set with a high probability of defect detection and a low rate of erroneous detections.
A new method for comparing the defect detection in a CT measurement to a reference data set is demonstrated, which provides individual information on every detected flaw.
We discuss the results of measurements in the assembled state with respect to the reference data for flaw detection.
Methode und Prüfkörper zum Nachweis von Gussdefekten in Aluminiumbauteilen mit Computertomographie
(2009)
Ein dreidimensionaler Prüfkörper für die Lunkererkennung in Gussteilen mittels Coputertomographie
(2009)
Since the advent of industrial computed tomography (CT), this new analysis method has been used also for the investigation of objects of cultural heritage and art. CT provides the possibility to determine the inner and outer surfaces and to investigate the material structure without causing damage to the valuable objects.
In this talk I will present examples of measurements performed at BAM, which demonstrate what CT can do for objects of diverse materials and for different objectives.
Ziel des Vorhabens ist die hochgenaue und vollständige Erfassung innerer und äußerer Geometrien von Mikrobauteilen mittels Mikro-Computertomographie (µCT). Industriell wichtige Mikrobauteile sind z.B. Einspritzsysteme, Festplattenkomponenten oder Instrumente für die minimal-invasive Chirurgie. Typische Bauteilgrößen liegen hier im Bereich 0,1 mm - 100mm; typische zu messende Strukturen haben Größen von 0,5 µm - 500 µm. Mit klassischen Methoden der Messtechnik ist eine schnelle und hochgenaue Erfassung der gesamten Oberfläche von Mikrobauteilen bisher kaum möglich. Innenstrukturen von Mikrobauteilen können mit keiner optischen oder taktilen Messtechnik zerstörungsfrei gemessen werden. Diese Einschränkungen sollen mittels hochgenauer µCT überwunden werden. Hierzu soll der Messprozess simuliert werden, um die Anwendung von Korrekturverfahren zur Genauigkeitssteigerung zu ermöglichen. CT-Messungen an kalibrierten Mikroprüfkörpern sollen die Korrekturverfahren verifizieren. Für die Kalibrierung der Prüfkörper sollen Multisensor-Verfahren entwickelt und getestet werden. Diese sollen es erlauben, Prüfkörper gleichzeitig hochgenau und mit großer Messpunktdichte zu kalibrieren. Es ist geplant, die an Prüfkörpern erreichten Messunsicherheiten und Auflösungen zum Projektabschluss an realen, industriellen Mikrobauteilen (z.B. Mikrozahnrädern) messtechnisch nachzuweisen.
Computertomographische Aufnahmen von Objekten mit stark
voneinander abweichenden Absorptionseigenschaften stellen sowohl für den
Anwendungsbereich der zerstörungsfreien Prüfung als auch für den der
dimensionellen Messtechnik eine besondere Herausforderung dar. Die
Aufnahmekonfiguration kann bei Objekten dieser Art häufig nicht so gewählt
werden, dass die unterschiedlichen Materialeigenschaften mit ausreichender Qualität
abgebildet werden können. Aus diesem Grund ist eine objektive Bewertung der
Oberflächenmessung mit Hilfe eines in dieser Untersuchung eingeführten
Qualitätsmaßes erforderlich. Anhand der in dieser Arbeit vorgestellten
Prüfkörperserie soll der Einfluss der Materialzusammensetzung auf das
dimensionelle Messen mit CT erfasst und charakterisiert werden. Unter
Berücksichtigung der Qualitätsbewertung der Oberflächenpunkte erfolgt die
Berechnung der Form- und Abstandsabweichungen. Ziel ist es, die Genauigkeit der
Oberflächenmessung hinsichtlich unterschiedlicher Aufnahmeparameter und
Materialzusammensetzungen darzustellen. Anhand dieser Ergebnisse ist es möglich,
den computertomographischen Aufnahme- und Auswertungsprozess quantitativ zu
bewerten und Ursachen der Abweichungen zu diskutieren.
Most knowledge about the structure, function, and evolution of early compound eyes is based on investigations in trilobites. However, these studies dealt mainly with the cuticular lenses and little was known about internal anatomy. Only recently some data on crystalline cones and retinula cells were reported for a Cambrian trilobite species. Here, we describe internal eye structures of two other trilobite genera. The Ordovician Asaphus sp. reveals preserved crystalline cones situated underneath the cuticular lenses. The same is true for the Devonian species Archegonus (Waribole) warsteinensis, which in addition shows the fine structure of the rhabdom in the retinula cells. These results suggest that an apposition eye with a crystalline cone is ancestral for Trilobita. The overall similarity of trilobite eyes to those of myriapods, crustaceans, and hexapods corroborates views of a phylogenetic position of trilobites in the stem lineage of Mandibulata.
Die Mikro- und Nanotechnologie gehört zu den Schlüsseltechnologien des 21. Jahrhunderts mit hohen Wachstumsprognosen, wie auch die im Auftrag des BMBF durchgeführte Studie “Nanotechnologie als wirtschaftlicher Wachstumsmarkt” von 2004 ausführlich darstellt. Aus diesem Trend resultiert ein steigender Bedarf an Messsystemen, die Nanostrukturen prozessnah bzw. im Fertigungsprozess charakterisieren können. Virtuelle Messgeräte liefern Erkenntnisse zur Entwicklung neuartiger Messsysteme, Analyse und Optimierung bestehender Verfahren sowie die Bestimmung der Messunsicherheit und modellbasierten Korrektur systematischer Fehler. Der virtuelle Messprozess umfasst neben dem Messmittel auch die Probe und die Wechselwirkungen zwischen beiden. In diesem Beitrag werden virtuelle Messgeräte vorgestellt sowie deren Anwendung diskutiert.
Subject of this investigation is the in-situ evolution of pore volume and pore size distribution in Ytong (a porous concrete material) under increasing pressure with two different non-destructive analytical methods: Nuclear Magnetic Resonance (NMR) and X-ray Computed Tomography (CT). For both methods special strain devices to apply external pressure were constructed. The results from the two techniques yield complementary information on the pore size distribution and allows covering different pore size regions.
Archaeological bone, ivory and antler, as well as objects manufactured from them, are largely studied to extract as much information as possible from these materials. Among others, one key question in archaeology is the exact identification of the material. Even if the identification of different kinds of osseous material seems to be trivial in many cases, it can be a difficult issue when small, heavily carved and more or less altered ancient objects are concerned. This study was focused on the determination of parameters allowing the distinction of archaeological ivory, bone and antler in order to identify the raw material used for the manufacture of prehistoric objects. The high performance of synchrotron radiation (SR) and laboratory-based micro X-ray computed tomography (microCT), providing highly resolved three-dimensional information on the micromorphology, permitted the establishment of such distinctive features of modern references of ivory, antler, land mammal and whale bones: ivory shows characteristic tubular pores with a diameter of about 1 to 2 µm, bone and antler show typical osteon structures. In our measured references, antler shows on average larger and more elongated shaped pores of the osteons compared to terrestrial mammal bone. This feature however depends very much on the original localization of the studied sample within the antler. Whale bones can be distinguished from the other osseous materials by a cancellous, osteoporotic-like structure with irregularly distributed rounded porosities with diameters reaching up to 500 µm. These characteristics have also been tested on determined Palaeolithic fragments, as diagenetic changes during burial have to be considered and may lead to the modification of the parameters established on the basis of modern bone references. In general, the chemical composition of bone objects can change drastically over time while micromorphological features, as evidenced by microCT, seem to be less susceptible to such alterations. In addition, microCT enables the comparison of inner and possibly less altered parts of the objects, and can be considered as completely non-destructive for small mineralised prehistoric objects. In this study, specific morphological features allowing the distinction of ivory and of whale bone from other bone and antler material were determined, even for altered materials dating back to Palaeolithic periods. Thus, we provide, in addition to archaeozoological, chemical and isotopic markers, a new non-destructive tool to identify some raw materials used for the fabrication of osseous objects ranging from recent to prehistoric periods.
Complementary to Part 1 of this work, the bi-continuous microstructure of porous synthetic cordierite ceramics for filtration applications was investigated using 3D x-ray computed tomography at different resolutions. Applying both Fast Fourier Transform and a newly developed image analysis algorithm, we quantitatively evaluated porosity and pore orientation. The statistical approach allows extraction of spatially resolved or average values. Porosity values based on x-ray absorption agree with mercury intrusion measurements, while pore orientation factors agree with x-ray refraction data (Part 1 of this work), and with published crystallographic texture data.
Die industrielle Computertomographie (CT) ist ein gut bekanntes Verfahren zur zerstörungsfreien Prüfung von Werkstücken. In den letzten Jahren wird die CT aber zunehmend auch für dimensioneile Messungen von Werkstücken eingesetzt. Der wesentliche Vorteil der CT liegt in der Kompletterfassung mit hoher Messpunktdichte, die auch für andere Messverfahren unzugängliche, innere Geometrien einschließt. An kleinen Bauteilen können Strukturen bis herunter zu wenigen Mikrometern gemessen werden, wodurch sich das Verfahren gut für die Messung von Mikroteilen eignet. Nachteilig ist, dass viele Einflussgrößen das Messergebnis beeinflussen, was die Rückführung der Messergebnisse, die Bestimmung der Messunsicherheit und die Definition von Spezifikationen für CT-Anlagen erschwert.
Der Beitrag stellt nach einer Einführung in das Verfahren Anwendungsbeispiele der CT an Mikroteilen vor. Darüber hinaus geht der Beitrag auf Prüfkörper und -verfahren zur Einmessung und Überprüfung von CT-Anlagen ein und berichtet über aktuelle Normungsaktivitäten. Abschließend werden Möglichkeiten zur weiteren Steigerung der Auflösung aufgezeigt, um zukünftig möglicherweise auch Nanogeometrien messen zu können.
Micro gears are applied in an increasing quantity in many applications. Therefore, precise measurements are of growing importance to ensure their quality. This contribution describes the measurement of gears of a micro planetary gear set with a tactile probe, a tactile-optical probe, an optical sensor, and computed tomography (CT). For the tactile measurements, a high precision piezoresistive microprobe was used. A so-called fiber probe was applied for tactile-optical measurements. This probe applies image processing to determine the position of the tactile probing element. For all tactile and tactile-optical measurements, single point probing was used. The optical measurements were carried out with an imaging sensor based on focus variation. Due to limited accessibility, on some gears not all regions could be measured by the optical sensor and the tactile-optical probe. In contrast to this, with CT the whole part could be measured with high point density. We used a micro-CT system and carried out measurements with Synchrotron-CT. All the sensors used deliver measurement data in Cartesian coordinates. It is a challenge to transfer these data into coordinates in which gear parameters are defined. For this, special attention must be paid to the determination of the gear axis and to the orientation of the teeth. The applied procedures are detailed for different micro gears. The comparison between data of different measurements was carried out successfully. The deviations between the CT data and the tactile or tactile-optical data lie in the range of only a few micrometers.
Anhand des hier vorgestellten zylindrischen Prüfkörpers, an dem
Kugeln aus einem Material mit einem hohen Absorptionskoeffizienten und sehr
geringen Formabweichungen angebracht wurden, können die geometrischen
Eigenschaften von CT-Anlagen untersucht werden. Die Basis der Auswertung
bilden die radiometrischen Aufnahmen. Mit Hilfe eines angepassten
Ellipsenoperators werden die Mittelpunkte der in den radiometrischen Aufnahmen
überlagerungsfrei abgebildeten Kugeln ermittelt. Anhand dieser Mittelpunkte
können die geometrischen Eigenschaften des Gesamtsystems zunächst rein an den
sich daraus ergebenen Spuren diskutiert und in einem weiteren Schritt
photogrammetrisch mit Hilfe der Bündelblockausgleichung ausgewertet werden.
Die Untersuchungen zeigen, dass der Prüfkörper geeignet ist, die geometrischen
Eigenschaften von CT-Anlagen zu überwachen. In einem weiteren Schritt könnte
das vorgestellte Verfahren benutzt werden, um z.B. Abweichungen von Drehtischen
zu charakterisieren und ggf. zu korrigieren.
In order to investigate their microcracking behaviour, the microstructures of several β-eucryptite ceramics, obtained from glass precursor and cerammed to yield different grain sizes and microcrack densities, were characterized by laboratory and synchrotron x-ray refraction and tomography. Results were compared with those obtained from scanning electron microscopy (SEM). In SEM images, the characterized materials appeared fully dense but computed tomography showed the presence of pore clusters. Uniaxial tensile testing was performed on specimens while strain maps were recorded and analyzed by Digital Image Correlation (DIC). X-ray refraction techniques were applied on specimens before and after tensile testing to measure the amount of the internal specific surface (i.e., area per unit volume). X-ray refraction revealed that (a) the small grain size (SGS) material contained a large specific surface, originating from the grain boundaries and the interfaces of TiO2 precipitates; (b) the medium (MGS) and large grain size (LGS) materials possessed higher amounts of specific surface compared to SGS material due to microcracks, which decreased after tensile loading; (c) the precursor glass had negligible internal surface. The unexpected decrease in the internal surface of MGS and LGS after tensile testing is explained by the presence of compressive regions in the DIC strain maps and further by theoretical arguments. It is suggested that while some microcracks merge via propagation, more close mechanically, thereby explaining the observed X-ray refraction results. The mechanisms proposed would allow the development of a strain hardening route in ceramics.
This poster presentation gives an overview of the great potential of X-ray micro computed tomography (CT) to cast light on the evolution of the microstructure in construction materials. Prevention of damage is of major economic and social importance in the development of suitable construction materials such as concrete and asphalt. Therefore a non-destructive testing method such as CT is an appropriate tool for visualization of the inner structure. Its combination with other test methods allows understanding the damage processes such as crack propagation or corrosion. We show examples of internal structure analyses on a wide range of materials: Automatic 3D crack detection and the visualization of corrosion products inside of steel reinforced concrete, pore and shape analysis of lightweight aggregates and the visualization of deformation of high-pressure loaded aerated concrete specimens, distribution of aggregates inside concrete, and determination of the surface of porous asphalt core samples. Segmented structures serve, e.g., as input data for simulation of transport phenomena or virtual load tests.
Evaluating porosity in cordierite diesel particulate filter materials, part 1 X-ray refraction
(2013)
Bi-continuous porous ceramics for filtration applications possess a particularly complicated microstructure, with porosity and solid matter being intermingled. Mechanical, thermal, and filtration properties can only be precisely estimated if the morphology of both solid matter and porosity can be quantitatively determined. Using x-ray absorption and refraction, we quantitatively evaluate porosity and pore orientation in cordierite diesel particulate filter ceramics. Porosity values turn out to agree with mercury intrusion measurements, while pore orientation factors agree with published crystallographic texture data.
Bi-continuous porous ceramics for filtration applications possess a particularly complicated microstructure, whereby porosity and solid matter are intermingled. Mechanical, thermal, and filtration properties can only be precisely estimated if the morphology of both solid matter and porosity can be quantitatively determined. Using 3D computed tomography (CT) at different resolutions, and several X-ray refraction-based techniques, we quantitatively evaluated porosity and pore orientation in cordierite diesel particulate filter ceramics.Moreover, applying both Fast Fourier Transform (FFT) and a newly developed image analysis algorithm (directional interface variance analysis, DIVA), we quantitatively evaluated porosity and pore orientation. Both the experimental techniques and the statistical approach allow extraction of spatially resolved or average values.Porosity values from synchrotron computed tomography used turn out to agree with mercury intrusion measurements, while pore orientation factors agree with published crystallographic texture data. This latter point also implies that the study of the pore/matter interface is sufficient to describe the morphological properties of these materials.