When reusing or disposing of contaminated granular waste materials there is a need to evaluate how the contaminants will interact on the pathway soil-groundwater and the effect this interaction will have on the surrounding environment. While column testing can provide a closer approximation to field percolation conditions than batch testing, there is still a need to develop column testing procedures that consider the requirements of practical testing time frames. This study evaluates the effect of different column contact times (2.5, 5, and 16 h) on the release of inorganic constituents from bottom ash and demolition waste, two commonly reused granular materials. Leaching data for representative constituents of concern, such as copper, chromium, sulfate and chloride, as well as pH and electrical conductivity was compared for all different contact times studied.
Results for the materials investigated in this study showed that variations in contact time have no significant effect on the release of the selected constituents and leaching parameters at low liquid to solid ratios. However, after a liquid to solid ratio of 1 L/kg, the effect is more noticeable, and higher contact times show lower pH values as well as a reduction in the release of constituents of concern from bottom ash. In the case of demolition waste, the variation of contact time did not have a strong effect on the leaching behavior.
Leaching experiments on the release of heavy metals and PAH from C&D waste and MSWI bottom ash
(2010)
Leaching tests are fundamental tools for the assessment of long-term impact of
contaminated waste materials on the soil-groundwater pathway. Waste materials should be
tested under conditions equal to their actual application in re-use scenarios to achieve reliable
results. Since the standards for leaching procedures available on international level so far are
either not validated or considered inadequate in respect to coarse grained materials, new
standards had to be developed. Therefore column percolation and batch test procedures have
been standardized and validated to enable their introduction to new German regulations
concerning waste management. Practical aspects of the test procedures as well as the
boundary conditions compared to the already existing standards will be described. Examples
including round robin test results will be given to justify the selection of the new
specifications.