Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (22)
- Beitrag zu einem Tagungsband (13)
- Vortrag (11)
- Beitrag zu einem Sammelband (10)
- Forschungsbericht (3)
- Sonstiges (1)
- Posterpräsentation (1)
Sprache
- Englisch (61) (entfernen)
Schlagworte
- Aerosol (9)
- Cascade impactor (7)
- TXRF (7)
- Particles (6)
- Air quality monitoring (4)
- ICP-MS (4)
- Ultrafine particles (4)
- Aerosols (3)
- Calibration (3)
- Element mass concentration (3)
Organisationseinheit der BAM
- 4 Material und Umwelt (25)
- 4.2 Material-Mikrobiom Wechselwirkungen (22)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.4 Prozessanalytik (2)
- 4.5 Kunst- und Kulturgutanalyse (2)
- 8 Zerstörungsfreie Prüfung (2)
- 8.0 Abteilungsleitung und andere (2)
- 9 Komponentensicherheit (2)
- 9.3 Schweißtechnische Fertigungsverfahren (2)
- 4.0 Abteilungsleitung und andere (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (11)
Geomembranes used in basal liner systems of landfills must not be damaged by the coarse gravel of the standard drainage layer. Therefore, the geomembrane must be protected against mechanical damage and strain by means of a suitable protective layer. The main requirements for this protective layer as well as the long-term durability of the mineral and geotextile components are compiled in the guideline recently released by German authorities. An overview is given on the existing types of protective layer systems with the state-of-the-art testing, the requirements and selected results of related research programs.
Geosynthetic clay liners (GCLs) often have a sandwich-like multilayer structure, e.g. bentonite encased between two geotextile layers connected by fibers or yarns, either by needle-punching or stitch-bonding. Therefore, the internal shear strength of the GCL depends on the strength of reinforcing fiber bundles or yarns and their anchoring strength in the cover and carrier geotextiles. When used on long and steep slopes and covered with thick soil layers, the GCL is permanently exposed to a combined action of compressive and shear stress. Such load conditions are characteristic for landfill covers and the slope stability of the overall cover system in the long run strongly depends on the long-term internal shear strength of the GCL. A new test method was developed to study this long-term shear behavior. The focus was not only on creep, as it is normally done, but on aging effects. The shear test devices allow the measurement of creep curves and times-to-failure at elevated temperatures in different media (tap water and de-ionized water). In this publication, the main findings of the experiments on needle-punched GCLs with and without thermal treatment are summarized. Tap water as a test medium was essential to ensure sodium to calcium ion exchange in the bentonite layer. Under this condition extremely long test durations without failure were achieved. Sliding failure occurred when de-ionized water was used. Two failure modes were observed: brittle failure of the GCLs with thermal treatment and slow disentanglement of fiber bundles for untreated GCLs. Short-term shear strength (e.g. peel strength) is unrelated to the actual long-term shear strength, i.e. to the times-to-failure achieved in long-term shear strength test. Hence, short-term shear strength alone will not provide reliable dimensioning data for product design and choice of resins. Therefore, the often suggested approach, namely, restriction to short-term tests only and application of factors of safety, is challenged by these results.
In this work, the elemental composition of fine and ultrafine particles emitted by ten different laser printing devices (LPD) is examined. The particle number concentration time series was measured as well as the particle size distributions. In parallel, emitted particles were size-selectively sampled with a cascade impactor and subsequently analyzed by the means of XRF. In order to identify potential sources for the aerosol's elemental composition, materials involved in the printing process such as toner, paper, and structural components of the printer were also analyzed. While the majority of particle emissions from laser printers are known to consist of recondensated semi volatile organic compounds, elemental analysis identifies Si, S, Cl, Ca, Ti, Cr, and Fe as well as traces of Ni and Zn in different size fractions of the aerosols. These elements can mainly be assigned to contributions from toner and paper. The detection of elements that are likely to be present in inorganic compounds is in good agreement with the measurement of nonvolatile particles. Quantitative measurements of solid particles at 400 °C resulted in residues of 1.6 × 109 and 1.5 × 1010 particles per print job, representing fractions of 0.2% and 1.9% of the total number of emitted particles at room temperature. In combination with the XRF results it is concluded that solid inorganic particles contribute to LPD emissions in measurable quantities. Furthermore, for the first time Br was detected in significant concentrations in the aerosol emitted from two LPD. The analysis of several possible sources identified the plastic housings of the fuser units as main sources due to substantial Br concentrations related to brominated flame retardants.
Two types of copper samples, compact certified copper reference materials and calibration samples prepared from liquid doped, pressed copper powders, were studied in terms of accuracy of obtained calibration functions originating from infrared spark ablation. Additionally, corresponding particle size distributions of the aerosols from infrared spark ablation were recorded. It is shown that the differences in quantification results, originating from the two sets of calibration functions, could not mainly be ascribed to different particle size distributions of the two copper sample types. Possible other causes, as different ablation rates, parts of melting and differences of the chemical constitutions of the two sample types were explored.
The results of investigations on the emission of particulate matter from three outdoor firework displays are presented. During these events, possibly harmful and toxic aerosol emissions were measured. Aerosols in the size range from 30 to 450 nm were detected. The maxima in the observed particle size distribution were between 80 and 175 nm, and the highest value determined was ~1.3 · 106 particles per cm³, while the highest mass concentration was approximately 1.8 mg m–3. The time-averaged particle mass concentration did, however, not exceed 0.7 mg m–3 (over 15 min).
This work presents results of investigations towards the emission of chemical reaction products and sound pressure during an outdoor and an indoor firework display. Potentially harmful and toxic gases, and aerosols, were measured as well as sound pressures. Aerosols were measured with a Differential Mobility Analyzer (DMA) as well as a Laser Particle Counter. The focus was on particles with diameters between 11 nm and 20 µm. A transportable Fourier Transform Infrared (FTIR) spectroscopy detector registered the concentrations of emitted reaction gases, simultaneously. During the outdoor firework display, peak particle concentrations of >550000 particles cm-3, equivalent to a mass concentration of approximately 3.95 mg m-3, were detected, revealing a concentration maximum at approximately 175 nm particle diameter. The time-averaged particle mass concentration did not exceed 1.58 mg m-3 over 15 minutes. Due to the large distances (110 m) to the firing points, no significant harmful or toxic gas concentrations were measured during the entire firework display. In contrast, concentrations of sulphur dioxide (SO2) rose after an indoor firework display in a large event hall. On two days, more than 23000 particles cm-3 (which equates to a mass concentration of approximately 0.41 mg m-3) were detected when the hall ventilation was turned off, and more than 11000 particles cm-3 (which equates to a mass concentration of approximately 1.18 mg m-3) when the hall ventilation was activated. Concentration maxima appeared at approximately 300 nm particle diameter. The time-averaged particle concentrations in this case did not exceed 0.56 mg m-3 (over 15 minutes).