Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (21)
Referierte Publikation
- ja (21) (entfernen)
Schlagworte
- Ultrafine particles (4)
- TXRF (3)
- Aerosol (2)
- Air pollution (2)
- Air quality monitoring (2)
- Calibration (2)
- Cascade impactor (2)
- Emission (2)
- Exposure (2)
- ICP-MS (2)
Organisationseinheit der BAM
- 4 Material und Umwelt (12)
- 4.2 Material-Mikrobiom Wechselwirkungen (10)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.4 Prozessanalytik (2)
- 4.5 Kunst- und Kulturgutanalyse (2)
- 8 Zerstörungsfreie Prüfung (2)
- 8.0 Abteilungsleitung und andere (2)
- 5 Werkstofftechnik (1)
- 5.1 Mikrostruktur Design und Degradation (1)
- 5.2 Metallische Hochtemperaturwerkstoffe (1)
Paper des Monats
- ja (1)
Untersuchung der Wirksamkeit von Filtern zum Schutz vor Partikelemissionen aus Laserdrucksystemen
(2012)
Laserdrucksysteme (Laserdrucker, -kopierer, Multifunktionsgeräte) emittieren in sehr unterschiedlichen Mengen Partikel im Größenbereich zwischen 5 und 300 nm, die im Druckbetrieb überwiegend durch Kondensation aus der Gasphase entstehen. Eine präventive Minderung dieser Emissionen ist sinnvoll. Die Filtration der in Laserdruckern entstehenden Aerosole bietet eine Option für eine wirksame Emissionsminderung. Die untersuchten Filter mit verschiedenen Filterkonzepten zeigten in ihrer Wirkung deutliche Unterschiede. Die Ergebnisse unterstreichen die Notwendigkeit der gerätespezifischen Optimierung von Filtern für die Anwendung in Laserdrucksystemen.----------------------------------------------------------------------------------------------------------------------------------------------
Laser printing devices are sources of particle emission in different quantities in the size range between 5 and 300 nm. The particles are predominantly generated by re-condensation from the gas phase. Emission mitigation as a precautionary measure should be considered and exhaust air filtration is one technical option. Two particle filters with different filter concepts were compared and revealed different levels of performance. The result underpins the need for individual filter solutions for laser printing devices.
In this work, we characterise the performance of a Sharp optical aerosol sensor model GP2Y1010AU0F. The sensor was exposed to different environments: to a clean room, to a controlled atmosphere with known aerosol size distribution and to the ambient atmosphere on a busy city street. During the exposure, the output waveforms of the sensor pulses were digitised, saved and a following offline analysis enabled us to study the behaviour of the sensor pulse-by-pulse. A linear response of the sensor on number concentration of the monosized dispersed PSL particles was shown together with an almost linear dependence on particle diameters in the 0.4 to 4 micrometer range.
The gathered data about the sensor were used to predict its response to an ambient atmosphere, which was observed simultaneously with a calibrated optical particle counter.
Ultrafine particles emitted from laser printers are suspected to elicit adverse health effects. We performed 75-minute exposures to emissions of laser printing devices (LPDs) in a standardized, randomized, cross- over manner in 23 healthy subjects, 14 mild, stable asthmatics, and 15 persons reporting symptoms associated with LPD emissions. Low-level exposures (LLE) ranged at the particle background (3000 cm−3) and High-level exposures (HLE) at 100 000 cm−3. Examinations before and after exp sures included spirometry, body plethysmography, transfer factors for CO and NO (TLCO, TLNO), bronchial and alveolar NO, cytokines in serum and nasal secretions (IL-1β, IL-5, IL-6, IL-8, GM-CSF, IFNγ, TNFα), serum ECP, and IgE. Across all participants, no statistically significant changes occurred for lung mechanics and NO. There was a decrease in volume-related TLNO that was more pronounced in HLE, but the difference to LLE was not significant. ECP and IgE increased in the same way after exposures. Nasal IL-6 showed a higher increase after LLE. There was no coherent pattern regarding the responses in the participant subgroups or single sets of variables. In conclusion, the experimental acute responses to short but very high-level LPD exposures were small and did not indicate clinically relevant effects compared to low particle number concentrations.
The possible impact of ultrafine particles from laser printers on human health is controversially discussed although there are persons reporting substantial symptoms in relation to these emissions. A randomized, single-blinded, cross-over experimental design with two exposure conditions (high-level and low-level exposure) was conducted with 23 healthy subjects, 14 subjects with mild asthma, and 15 persons reporting symptoms associated with laser printer emissions. To separate physiological and psychological effects, a secondary physiologically based categorization of susceptibility to particle effects was used. In line with results from physiological and biochemical assessments, we found no coherent, differential, or clinically relevant effects of different exposure conditions on subjective complaints and cognitive performance in terms of attention, short-term memory, and psychomotor performance. However, results regarding the psychological characteristics of participants and their situational perception confirm differences between the participants groups: Subjects reporting symptoms associated with laser printer emissions showed a higher psychological susceptibility for adverse reactions in line with previous results on persons with multiple chemical sensitivity or idiopathic environmental intolerance. In conclusion, acute psychological and cognitive effects of laser printer emissions were small and could be attributed only to different participant groups but not to differences in exposure conditions in terms of particle number concentrations.
Mobility particle size spectrometers (MPSS) belong to the essential instruments in aerosol science that determine the particle number size distribution (PNSD)in the submicrometer size range. Following calibration procedures and target uncertainties against standards and reference instruments are suggested for a complete MPSS quality assurance program: a) calibration of the CPC counting efficiency curve (within 5% for the plateau counting efficiency; within 1 nm for the 50% detection efficiency diameter), b) sizing calibration of the MPSS, using a certified polystyrene latex (PSL) particle size standard at 203 nm (within 3%), c) intercomparison of the PNSD of the MPSS (within 10% and 20% of the dN/dlogDP concentration for the particle size range 20 – 200 nm and 200 to 800 nm, respectively), and d) intercomparison of the integral PNC of the MPSS (within 10%). Furthermore, following measurement uncertainties have been investigated: a) PSL particle size standards in the range from 100-500nm match within 1% after sizing calibration at 203 nm. b) Bipolar diffusion chargers based on the radioactive nuclides Kr85, Am241 and Ni63 and a new ionizer based on corona discharge follow the recommended bipolar charge distribution, while soft X-ray-based charges may alter faster than expected. c) The use of a positive high voltage supply show a 10% better performance than a negative one. d) The intercomparison of the integral PNC of an MPSS against the total number concentration is still within the target uncertainty at an ambient pressure of approximately 500 hPa.
3D-printing or additive manufacturing has many promising and unique advantages. Especially low cost molten polymer Deposition Printers are increasingly populär in the private and educational sector.
Their environmental friendliness can be questioned due to recently reported ultrafine particle and suspected VOC emissions, To further investigate 3D-printing as a potential indoor air pollution source we characterized fine and ultrafine particle emissions from a molten polymer deposition printer producing a 3D object with ten marketable polymer filament materials under controlled conditions in a test chamber. VOC emissions from the filaments have also been compared. Using a straightforward emission model time dependent and averaged particle emission rates were determined. The results indicate that under comparable conditions some filament materials produce mainly ultrafine particles up to an average rate of 1013 per minute. This value is in the upper ränge of typical indoor ultrafine particle sources (e.g. Smoking, frying, candle light, laser printer). The observed material-specific rates differ by five Orders of magnitude. Filament-specific gaseous emissions of organic compounds such as bisphenol A, styrene and others were also detected.
Our results suggest a detailed evaluation of related risks and considering protective measures such as housing and filtering.
Quantitative chemical analysis of airborne particulate matter (PM) is vital for the understanding of health effects in indoor and outdoor environments, as well as for enforcing EU air quality regulations. Typically, airborne particles are sampled over long time periods on filters, followed by lab-based analysis, e.g., with inductively coupled plasma mass spectrometry (ICP-MS). During the EURAMET EMPIR AEROMET project, cascade impactor aerosol sampling is combined for the first time with on-site total reflection X-ray fluorescence (TXRF) spectroscopy to develop a tool for quantifying particle element compositions within short time intervals and even on-site. This makes variations of aerosol chemistry observable with time resolution only a few hours and with good size resolution in the PM10 range. The study investigates the proof of principles of this methodological approach. Acrylic discs and silicon wafers are shown to be suitable impactor carriers with sufficiently smooth and clean surfaces, and a non-destructive elemental mass concentration measurement with a lower limit of detection around 10 pg/m3 could be achieved. We demonstrate the traceability of field TXRF measurements to a radiometrically calibrated TXRF reference, and the results from both analytical methods correspond satisfactorily.
A new facility has been developed which allows for a stable and reproducible production of ambient-like model aerosols (PALMA) in the laboratory. The set-up consists of multiple aerosol generators, a custom-made flow tube homogeniser, isokinetic sampling probes, and a system to control aerosol temperature and humidity. Model aerosols containing elemental carbon, secondary organic matter from the ozonolysis of α-pinene, inorganic salts such as ammonium sulfate and ammonium nitrate, mineral dust particles,and water were generated under different environmental conditions and at different number and mass concentrations. The aerosol physical and chemical properties were characterised with an array of experimental methods, including scanning mobility particle sizing, ion chromatography, total reflection X-ray fluorescence spectroscopy and thermo-optical analysis. The facility is very versatile and can find applications in the calibration and performance characterisation of aerosol instruments monitoring ambient air. In this study, we performed, as proof of concept, an intercomparison of three different commercial PM (particulate matter) monitors (TEOM1405, DustTrak DRX 8533 and Fidas Frog) with the gravimetric reference method under three simulated environmental scenarios. The results are presented and compared to previous field studies. We believe that the laboratory-based method for simulating ambient aerosols presented here could provide in the future a useful alternative to time-consuming and expensive field campaigns, which are often required for instrument certification and calibration.
The emission of ultrafine particles from small desktop Fused Filament Fabrication (FFF) 3D printers has been frequently investigated in the past years. However, the vast majority of FFF emission and exposure studies have not considered the possible occurrence of particles below the typical detection limit of Condensation Particle Counters and could have systematically underestimated the total particle emission as well as the related exposure risks. Therefore, we comparatively measured particle number concentrations and size distributions of sub-4 nm particles with two commercially available diethylene glycol-based instruments – the TSI 3757 Nano Enhancer and the Airmodus A10 Particle Size Magnifier. Both instruments were evaluated for their suitability of measuring FFF-3D printing emissions in the sub-4 nm size range while operated as a particle counter or as a particle size spectrometer. For particle counting, both instruments match best when the Airmodus system was adjusted to a cut-off of 1.5 nm. For size spectroscopy, both instruments show limitations due to either the fast dynamics or rather low levels of particle emissions from FFF-3D printing in this range. The effects are discussed in detail in this article. The findings could be used to implement sub-4 nm particle measurement in future emission or exposure studies, but also for the development of standard test protocols for FFF-3D printing emissions.
Fused filament fabrication (FFF) is a material extrusion-based technique often used in desktop 3D printers. Polymeric filaments are melted and are extruded through a heated nozzle to form a 3D object in layers. The extruder temperature is therefore a key parameter for a successful print job but also one of the main emission driving factors as harmful pollutants (e.g., ultrafine particles) are formed by thermal polymer degradation. The awareness of potential health risks has increased the number of emission studies in the past years. However, studies usually refer their calculated emission data to the printer set extruder temperature for comparison purposes. In this study, we used a thermocouple and an infrared camera to measure the actual extruder temperature and found significant temperature deviations to the displayed set temperature among printer models. Our result shows that printing the same filament feedstocks with three different printer models and with identical printer set temperature resulted in a variation in particle emission of around two orders of magnitude. A temperature adjustment has reduced the variation to approx. one order of magnitude. Thus, it is necessary to refer the measured emission data to the actual extruder temperature as it poses a more accurate comparison parameter for evaluation of the indoor air quality in user scenarios or for health risk assessments.
The development of traceable new methodologies to quantify elemental air pollutants in particulate matter (PM) supports modernization of methods used in air quality monitoring networks in Europe. In the framework of the EURAMET EMPIR AEROMET II project, the combination of cascade impactor aerosol sampling and total reflection X-ray fluorescence elemental spectroscopy (TXRF) was investigated. This technique requires a traceable calibration based on reference samples. This paper describes a new, simple and effective method to produce such reference samples using flexible, reusable, and low-cost parylene C shadow masks, fabricated by photolithographic steps. These shadow masks can be used to produce reference samples that mimic the Dekati cascade impactor’s deposition patterns by applying as-prepared micro stencils to 30 mm acrylic substrates and evaporating a reference material (Ti) in arrangements of thin circular dots. The highly flexible direct patterning of acrylic discs with reference material, otherwise impossible with conventional photolithography, allows multiple reusing of the same micro stencils. The aspect ratios of the dots could be repeated with an error less than 4 %. A first set of standard reference samples for the 13 stages of the Dekati cascade impactor was produced and preliminary TXRF measurements of the deposited Ti masses were performed. The centricity of the deposition patterns turned out to be an important parameter for the quality of the TXRF results. The parylene mask technology for the production of reference samples turns out to be a promising new approach for the traceable calibration of TXRF spectrometers for the quantification of element concentrations in environmental aerosol samples but, due to its great versatility, it could be used for several other micropatterning applications on conventional and unconventional substrates.
Condensation particle counters (CPCs) are widely used for the measurement of aerosol particle number concentrations in the size range from approximately 3 nm to 3 μm. For an SI-traceable calibration of the size-dependent counting efficiency, which is advisable on a regular basis and required in several applications, Faraday cup aerosol electrometers (FCAEs) are considered to be a suitable SI-traceable reference.While the volumetric aerosol inlet flowrate and the electrical current measurement in FCAEs can be related to respective SI references, inter-comparison exercises for FCAEs are still performed on a regular basis to establish reliable uncertainty budgets and to further investigate the influences of designs and operational parameters on comparability. This is strongly demanded in the international community of metrological institutes and aerosol calibration facilities around the world, which provide CPC calibrations. In the present study, the performance of FCAEs was investigated,using Ag test aerosol particles with a 30 nm particle diameter by varying the inlet flowrates from 0.5 l min−1 to 4 l min−1. From our experimental results, significant deviations were observed in FCAE currents at sample flowrates smaller than 1.5 l min−1. It is recommended that these discrepancies should be quantified before an FCAE is used for CPC calibration at low sample flowrates and small particle sizes in the sub-30 nm size range.
Geomembranes used in basal liner systems of landfills must not be damaged by the coarse gravel of the standard drainage layer. Therefore, the geomembrane must be protected against mechanical damage and strain by means of a suitable protective layer. The main requirements for this protective layer as well as the long-term durability of the mineral and geotextile components are compiled in the guideline recently released by German authorities. An overview is given on the existing types of protective layer systems with the state-of-the-art testing, the requirements and selected results of related research programs.
Geosynthetic clay liners (GCLs) often have a sandwich-like multilayer structure, e.g. bentonite encased between two geotextile layers connected by fibers or yarns, either by needle-punching or stitch-bonding. Therefore, the internal shear strength of the GCL depends on the strength of reinforcing fiber bundles or yarns and their anchoring strength in the cover and carrier geotextiles. When used on long and steep slopes and covered with thick soil layers, the GCL is permanently exposed to a combined action of compressive and shear stress. Such load conditions are characteristic for landfill covers and the slope stability of the overall cover system in the long run strongly depends on the long-term internal shear strength of the GCL. A new test method was developed to study this long-term shear behavior. The focus was not only on creep, as it is normally done, but on aging effects. The shear test devices allow the measurement of creep curves and times-to-failure at elevated temperatures in different media (tap water and de-ionized water). In this publication, the main findings of the experiments on needle-punched GCLs with and without thermal treatment are summarized. Tap water as a test medium was essential to ensure sodium to calcium ion exchange in the bentonite layer. Under this condition extremely long test durations without failure were achieved. Sliding failure occurred when de-ionized water was used. Two failure modes were observed: brittle failure of the GCLs with thermal treatment and slow disentanglement of fiber bundles for untreated GCLs. Short-term shear strength (e.g. peel strength) is unrelated to the actual long-term shear strength, i.e. to the times-to-failure achieved in long-term shear strength test. Hence, short-term shear strength alone will not provide reliable dimensioning data for product design and choice of resins. Therefore, the often suggested approach, namely, restriction to short-term tests only and application of factors of safety, is challenged by these results.
Beim Abbrand einzelner Feuerwerkskörper für den Indoor-Bereich wurden als gasförmige Hauptreaktionsprodukte unter anderem CO2, CO, COS, nitrose Gase, diverse Kohlenwasserstoffe und Schwefelverbindungen (teilweise in sehr hohen Konzentrationen) mit Hilfe der FTIR-Spektroskopie nachgewiesen. Zusätzliche Feinstaubmessungen parallel zum Abbrand in einem großen Raum illustrierten die zeitweise hohen Partikelkonzentrationen an unterschiedlichen Messpunkten.
The results of investigations on the emission of particulate matter from three outdoor firework displays are presented. During these events, possibly harmful and toxic aerosol emissions were measured. Aerosols in the size range from 30 to 450 nm were detected. The maxima in the observed particle size distribution were between 80 and 175 nm, and the highest value determined was ~1.3 · 106 particles per cm³, while the highest mass concentration was approximately 1.8 mg m–3. The time-averaged particle mass concentration did, however, not exceed 0.7 mg m–3 (over 15 min).
In this work, the elemental composition of fine and ultrafine particles emitted by ten different laser printing devices (LPD) is examined. The particle number concentration time series was measured as well as the particle size distributions. In parallel, emitted particles were size-selectively sampled with a cascade impactor and subsequently analyzed by the means of XRF. In order to identify potential sources for the aerosol's elemental composition, materials involved in the printing process such as toner, paper, and structural components of the printer were also analyzed. While the majority of particle emissions from laser printers are known to consist of recondensated semi volatile organic compounds, elemental analysis identifies Si, S, Cl, Ca, Ti, Cr, and Fe as well as traces of Ni and Zn in different size fractions of the aerosols. These elements can mainly be assigned to contributions from toner and paper. The detection of elements that are likely to be present in inorganic compounds is in good agreement with the measurement of nonvolatile particles. Quantitative measurements of solid particles at 400 °C resulted in residues of 1.6 × 109 and 1.5 × 1010 particles per print job, representing fractions of 0.2% and 1.9% of the total number of emitted particles at room temperature. In combination with the XRF results it is concluded that solid inorganic particles contribute to LPD emissions in measurable quantities. Furthermore, for the first time Br was detected in significant concentrations in the aerosol emitted from two LPD. The analysis of several possible sources identified the plastic housings of the fuser units as main sources due to substantial Br concentrations related to brominated flame retardants.
The diversity of fused filament fabrication (FFF) filaments continues to grow rapidly as the popularity of FFF-3D desktop printers for the use as home fabrication devices has been greatly increased in the past decade. Potential harmful emissions and associated health risks when operating indoors have induced many emission studies. However, the lack of standardization of measurements impeded an objectifiable comparison of research findings. Therefore, we designed a chamber-based standard method, i.e., the strand printing method (SPM), which provides a standardized printing procedure and quantifies systematically the particle emission released from individual FFF-3D filaments under controlled conditions. Forty-four marketable filament products were tested. The total number of emitted particles (TP) varied by approximately four orders of magnitude (1E9 ≤ TP ≤ 1E13), indicating that origin of polymers, manufacturer-specific additives, and undeclared impurities have a strong influence. Our results suggest that TP characterizes an individual filament product and particle emissions cannot be categorized by the polymer type (e.g., PLA or ABS) alone. The user's choice of a filament product is therefore decisive for the exposure to released particles during operation. Thus, choosing a filament product awarded for low emissions seems to be an easily achievable preemptive measure to prevent health hazards.
The physical and chemical analysis of aerosols using reliable and physically traceable methods is important for the thorough investigation of airborne particles to support a better understanding of their origin as well as their health and climate impacts. Within the European Metrology Research AeroMet project,the aim of hysikalisch–Technische Bundesanstalt’s (PTB) X-ray spectrometry group is to develop and establish traceable and reliable X-ray methods to measure the elemental mass deposition per unit area, the elemental composition,and the chemical binding state of particulate matter supported by a flat substrate. This approach can substantially contribute to support quantitative analytical methods during on-site measurement campaigns where portable Instrumentation is employed by qualifying suitable calibration samples for commercial analytical X-ray instruments and by investigating samples collected during the field campaign.
Two types of copper samples, compact certified copper reference materials and calibration samples prepared from liquid doped, pressed copper powders, were studied in terms of accuracy of obtained calibration functions originating from infrared spark ablation. Additionally, corresponding particle size distributions of the aerosols from infrared spark ablation were recorded. It is shown that the differences in quantification results, originating from the two sets of calibration functions, could not mainly be ascribed to different particle size distributions of the two copper sample types. Possible other causes, as different ablation rates, parts of melting and differences of the chemical constitutions of the two sample types were explored.