Filtern
Dokumenttyp
- Zeitschriftenartikel (12)
- Vortrag (8)
- Beitrag zu einem Tagungsband (3)
- Sonstiges (2)
- Posterpräsentation (1)
- Forschungsbericht (1)
Schlagworte
- Aerosol (7)
- Cascade impactor (7)
- TXRF (7)
- Air quality monitoring (4)
- Element mass concentration (3)
- ICP-MS (3)
- Particles (3)
- Ultrafine particles (3)
- Additive Manufacturing (2)
- Aerosole (2)
Organisationseinheit der BAM
- 4 Material und Umwelt (27) (entfernen)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (8)
In this work, we characterise the performance of a Sharp optical aerosol sensor model GP2Y1010AU0F. The sensor was exposed to different environments: to a clean room, to a controlled atmosphere with known aerosol size distribution and to the ambient atmosphere on a busy city street. During the exposure, the output waveforms of the sensor pulses were digitised, saved and a following offline analysis enabled us to study the behaviour of the sensor pulse-by-pulse. A linear response of the sensor on number concentration of the monosized dispersed PSL particles was shown together with an almost linear dependence on particle diameters in the 0.4 to 4 micrometer range.
The gathered data about the sensor were used to predict its response to an ambient atmosphere, which was observed simultaneously with a calibrated optical particle counter.
The emission of ultrafine particles from small desktop Fused Filament Fabrication (FFF) 3D printers has been frequently investigated in the past years. However, the vast majority of FFF emission and exposure studies have not considered the possible occurrence of particles below the typical detection limit of Condensation Particle Counters and could have systematically underestimated the total particle emission as well as the related exposure risks. Therefore, we comparatively measured particle number concentrations and size distributions of sub-4 nm particles with two commercially available diethylene glycol-based instruments – the TSI 3757 Nano Enhancer and the Airmodus A10 Particle Size Magnifier. Both instruments were evaluated for their suitability of measuring FFF-3D printing emissions in the sub-4 nm size range while operated as a particle counter or as a particle size spectrometer. For particle counting, both instruments match best when the Airmodus system was adjusted to a cut-off of 1.5 nm. For size spectroscopy, both instruments show limitations due to either the fast dynamics or rather low levels of particle emissions from FFF-3D printing in this range. The effects are discussed in detail in this article. The findings could be used to implement sub-4 nm particle measurement in future emission or exposure studies, but also for the development of standard test protocols for FFF-3D printing emissions.
Berichtet wird über ein abgeschlossenes Folgeprojekt zu vorangegangenen Forschungsprojekte zum gleichen Thema. In diesem Projekt wurde das Messverfahren und der Prüfwert für die Partikelemission aus Bürogeräten (siehe Vergabegrundlage DE-UZ 205, Anhang S-M) validiert und weiterentwickelt. Dies geschah erstens durch Auswertung der Qualität der im Zuge der Antragsbearbeitung für das Umweltzeichen beim RAL vorgelegten Prüfberichte der zugelassenen Prüfinstitute und - basierend darauf - durch Erarbeitung von technisch-methodischen Veränderungsvorschlägen für die Prüfung der chemischen Emissionen, inklusive der Partikelemissionen. Zweitens wurde zur Beurteilung der Veränderung der Emissionen aktueller gegenüber älteren Geräte-generationen ein nicht repräsentativer Pool von table-top-Laserdruckern aufgebaut und die chemischen Emissionen wurden gemäß DE-UZ-205, Anhang S-M gemessen. Ergänzend wurde eine quantitative chemische Analyse der anorganischen Feststoffe - insbesondere der Metalle - in den emittierten Aerosolen vorgenommen die Feststoffgehalte um 2 Massen-% ergaben. Diese Ergebnisse wurden gemeinsam mit neueren wissenschaftlichen Untersuchungen zur gesundheitlichen Bewertung der Emissionen aus Laserdruckern ausgewertet, es besteht kein Handlungsbedarf hinsichtlich einer Veränderung von Prüfkriterien und Prüfwerten. Drittens wurde untersucht und bestätigt, dass mit dem Ziel eines zukünftigen Umweltzeichens das Emissionsverhalten Kunststoff verarbeitender 3D-FDM-Drucker und/oder die darin verarbeiteten Verbrauchsmaterialien (Filamente) mit dem für Laserdrucker entwickelten Mess- und Prüfschema charakterisiert und quantifiziert werden können. Untersuchungen an Stereo-lithografie (SLA)-Druckern und Vorrichtungen zur Nach-Aushärtung (Curing Units) ergaben keine nachweisbaren Partikelemissionen.
Laser Powder Bed Fusion (L-PBF) is a promising additive manufacturing (AM) technology for metal part production especially for complex and lightweight structures or functional designs. In L PBF processes several by-products including welding plume and its condensates, spatter and ejected powder are generated during laser exposure. Investigations of micro- and nano-sized by-products have received little attention in literature. This study focuses on the analysis of particle emissions in L PBF of 316L stainless steel using a scattered light aerosol spectrometer and a fast mobility particle sizer spectrometer during the process which allows for in-situ analysis of particle sizes in the range of 6 nm to 100 µm. A distinct correlation of emission signals to part position can be revealed. In addition, a significant influence of laser scanning vector directions on emission signals is presented. Furthermore, differing powder layer thicknesses can be recognised by deviations in emission signals.
Measurements of aerosol particles are vital for enforcing EU air quality regulations to protect human health, and for research on climate change effects. Although metrics such as PM10 and PM2.5 are currently in use, the level of uncertainty of aerosol metrics is too high and the traceability is insufficient. The project AEROMET, which has been started in June 2017 aims at implementing improvements in a) the uncertainty of particle mass, size and number concentration measurements and b) in the characterization of regulated components in airborne particles. Both are demanded by existing networks within the EU as well as by global atmospheric research.
On-site measurement campaigns
One of the objects is the application of mobile x-ray spectroscopy techniques combined with aerosol sampling techniques for quantifying particle compositions in the field for real time analysis. During two in-field measurement campaigns in Budapest, Hungary in May 2018 and Cassino, Italy in September 2018 the size dependent mass concentrations of specific elements in ambient aerosols were monitored under dynamic conditions.
Typically, airborne particles are sampled on filter substrates. During this project new sampling methods with specially designed substrate holders for an in-situ TXRF analysis were developed and applied for the first time. This approach allows a direct time and size resolved analysis without laborious digestion steps and a reduced risk of contamination.
Aerosol particles were sampled in a 13-stage DLPI impactor - size range from 0,03 µm to 10 µm - which was equipped with special adapters for acrylic discs of 30 mm diameter, serving as substrates. TXRF analysis was performed on site with the transportable spectrometer S2 PICOFOX (Bruker Nano GmbH) equipped with a Mo X-ray tube and a 30 mm² Silicon Drift Detector (SDD). Excitation conditions were 50 kV, 600 µA, measurement time 1000 s. Quantification was based on internal standardization using 50 ng of Y in solution, which was pipetted into the centre of the discs prior to sampling.
At moderate air pollution levels, i.e. PM10 ~ 20 µg/m³, sampling times of less than 2 hours were enough for the detection of elements in different particle size bins. The in-situ approach and the high sensitivity of TXRF enables the observation of rather quick changes in the quantity and distribution of elements in an ambient aerosol on the day of sampling, as the below example from the Cassino field campaign on 11 Sept. 2018 shows: The analysis of the morning and afternoon sampling shifts reveals the occurrence of the elements Fe, Ca and Si in different size bins as well as their significant temporal change in respective mass concentrations over the day while the distributions of several other elements in the aerosol remain unchanged.
The validation of these results by backup measurements is planned.
A mobile Bruker S2 Picofox TXRF spectrometer has been used in two field campaigns within the EMPIR env07 AEROMET project for the on-site analysis of cascade impactor aerosol samples.The results show that even at moderate air pollution levels – i.e.PM10 fairly below 20 μg/m³ - element mass concentrations in air in the range of 100 pg/m³could be measured in up to 13 size bins after sampling times of less than only 0.5 days.