Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (38)
- Zeitschriftenartikel (15)
- Vortrag (7)
- Beitrag zu einem Sammelband (5)
- Posterpräsentation (5)
- Buchkapitel (1)
Schlagworte
- OTDR (8)
- Structural health monitoring (8)
- POF (7)
- Distributed fiber sensing (6)
- Distributed acoustic sensing (5)
- Distributed fiber optic sensing (5)
- Strain sensor (5)
- Temperature sensor (5)
- Atmungssensor (4)
- Faseroptischer Sensor (4)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (22)
- 8.6 Faseroptische Sensorik (22)
- 3 Gefahrgutumschließungen; Energiespeicher (6)
- 3.0 Abteilungsleitung und andere (3)
- 5 Werkstofftechnik (3)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (3)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.4 Prozessanalytik (2)
- 3.5 Sicherheit von Gasspeichern (2)
- 5.3 Polymere Verbundwerkstoffe (2)
Eingeladener Vortrag
- nein (7)
For patients under Magnetic Resonance Imaging (MRI) spontaneous respiration is constantly at risk of being impaired by anesthetic drugs or by upper airway obstruction. Therefore, continuous monitoring of the breathing activity is needed to assess adequate ventilation or to detect specific obstruction patterns. The paper describes three MRI compatible respiration sensors based on pure optical technologies developed within the EU FP6 project OFSETH. The sensors are based on fiber Bragg gratings, optical time-domain reflectometry and macrobending effects. The developed smart medical textiles can sense elongation up to 3% while maintaining the stretching properties of the textile substrates for patient's comfort. The OFSETH harness allows a continuous measurement of abdominal and thoracic respiration movement while all vitals organs are free for medical staff actions. The sensors were tested in MRI environment and on healthy adults.
In this paper a technique for integrating copper coated silica optical fibers into AS-4/PEEK composite for Structural Health Monitoring (SHM) is presented. The integration steps are described in detail. X-ray and microscopic images indicate a successfully integrated optical fiber which does not seem to affect the fiber/matrix distribution around it. Optical backscatter reflectometry shows losses of approximately 2dBm-1 along the integrated parts of the optical fiber due to temperature induced shrinkage of the composite.
We investigated to our knowledge for the first time the capabilities of long period gratings (LPG) in single-mode microstructured polymer optical fibre (mPOF) as real-time gamma dosimeter. The fibre is made from polymethyl methacrylate (PMMA) with a polycarbonate jacket. We measured the radiation-induced wavelength shift of the mPOF LPG loss feature wavelength and the radiation-induced attenuation of a mPOF for
different wavelength between 600 nm and 800 nm for gamma radiation with an energy distribution between 6 keV and 18 keV.
This paper reports on a fibre optic sensor for heart rate measurement which is developed within the framework of the FP7 EU project i-Protect. Goal is integration of the sensor into personal protective equipment Two different sensor prototypes based on polymer optical fibre (POF) were developed. One is based on long period gratings in microstrutured POF and the other one is based on macrobending effects in POF.
We investigate two real-time strain sensing principles based on the optical time-domain reflectometry
(OTDR) in polymer optical fibres (POF). The first sensing principle uses the increase of the level of backscattered light
in a stretched POF. The second sensing principle uses the effect of losses due to bending.
The potential impact of optical fiber sensors embedded into medical textiles for the monitoring of respiratory movements in a magnetic resonance imaging environment is presented. We report on three different designs, all textile based: a macrobending sensor, a Bragg grating sensor, and a time reflectometry sensor. In all three cases, the sensing principle is based on the measure of the elongation of the abdominal circumference during breathing movements. We demonstrate that the three sensors can successfully sense textile elongations between 0% and 3%, while maintaining the stretching properties of the textile substrates for a good comfort of the patients.
Die Eignung von Faser-Bragg-Gitter-(FBG)-Sensoren zur Messung ionisierender Strahlung wurde an einem Undulator des Elektronenspeicherrings BESSY II untersucht. Über einen Zeitraum von 20 Wochen wurde eine durch Strahlung verursachte Bragg-Wellenlängenänderung der FBG-Sensoren von 25pm gemessen, was einer Strahlendosis von 720 Gy entspricht.
The suitability of using fiber Bragg grating (FBG) sensors for the measurement of ionizing radiation on the electron storage ring BESSY II by measuring the Bragg wavelength shift caused by radiation was investigated. During a time period of 20 weeks a Bragg wavelength shift of 25pm caused by the ionizing radiation was measured by FBG sensors at the storage ring. This Bragg wavelength shift corresponds to a radiation dose value of 720 Gy.
Fiber optic sensors based on polymer optical fibers (POF) take advantage of the high elasticity and high break-down strain of POF. Because of their outstanding elastic properties, POF are well suited for integration into technical textiles like geotextiles and medical textiles. Smart textiles with incorporated POF sensors, able to sense various mechanical and physical quantities, can be realized. The integration of POF as a sensor into geotextiles for monitoring of displacement of soil is very attractive since POF can be used for distributed strain measurement of strain values of more than 40 %. An online monitoring of critical mechanical deformations of geotechnical structures like dikes, dams, slopes, embankments as well as of masonry structures can be ensured. Medical textiles that incorporate POF sensors can control vital physiological parameters like respiratory movement and can be used for wearable health monitoring of patients requiring a continuous medical assistance and treatment. The biocompatibility of POF is an important criterion for selecting POF as a medical sensor. The paper shows selected examples of using POF sensors for the mentioned monitoring purposes.