Easy to handle and stretchable polymer optical fibres for sensor applications
Basic idea of stimulated Brillouin scattering
Brillouin threshold for PMMA-POF and PFGI-POF in comparison
Sensorial behavior of Brillouin scattering in PFGI-POF and silica SMF
Basics and classification of distributed Brillouin sensing methods
Basic idea of dynamic Brillouin sensing
We demonstrate (and are the first to do so) 63 km Brillouin Optical Frequency-Domain Analysis (BOFDA) for temperature and strain monitoring using a 100 km fiber loop. The use of BOFDA for long-range applications can be considered a novel approach, as previous investigations focused on the utilization of Brillouin Optical Time-Domain Reflectometry and Analysis (BOTDR and BOTDA, respectively). At 51.7 km, a 100 m hotspot (37 °C) was detected without using distributed Raman amplification or image processing.
We report, to our knowledge, for the first time on humidity-induced Brillouin frequency shifts in perfluorinated graded index polymer optical fibers. A linear relation between Brillouin frequency shift and humidity was observed. Furthermore, the humidity coefficient of the Brillouin frequency shift is demonstrated to be a function of temperature (-107 to -64 kHz/%r.h. or -426 to -49 kHz m3/g in the range of 20 to 60 °C). An analytical description proves temperature and humidity as two mutually independent effects on the Brillouin frequency shift.
In this thesis, a distributed Brillouin sensor in perfluorinated polymer optical fibers utilizing BOFDA is presented. These commercially available polymer fibers offer beneficial characteristics for sensing applications such as higher break down strain up to 100 %, minimal bending radii below 2 mm, higher sensitivity to temperature and lower sensitivity to strain compared to their silica equivalent.
The chosen wavelength of operation at 1319 nm corresponds to lower fiber propagation loss (< 37 dB/km) compared to other approaches at 1550 nm (150 - 250 dB/km). A 86 m PFGI-POF was successfully measured by BOFDA with spatial resolution of 3.4 m.
The findings related to humidity influences can serve as a basis for future distributed humidity sensors not only limited to stimulated Brillouin backscattering.
We present our research on the development of a Brillouin optical frequency-domain analysis (BOFDA) using a perfluorinated graded-index polymer optical fiber (PFGI-POF) as a sensing fiber. The described works include investigations both on the selection of the setup components with respect to mode coupling effects and on the impact of the humidity cross-sensitivity. The suitability of the developed POF-based BOFDA is proved by a distributed measurement on an 86 m long PFGI-POF recorded with the spatial resolution of 6 m.
In this paper, we present a study aimed at characterizing the optimal fiber optic components for Brillouin sensing in multimode fibers. For this purpose the use of single-mode and multimode circulators as well as couplers typically used in the Brillouin measurement setups was investigated. On the one hand the undesired coupling losses between conventional fiber optic measurement system components and a multimode sensor fiber can be overcome by replacing the singlemode components with their own multimode equivalents. On the other hand the use of multimode fiber optic circulators and multimode couplers affects the mode distribution of laser light which can impair the measurement signal backscattered in the multimode sensor fibers. In view of an increasing interest in high strain measurements using polymer optical fibers (POFs) as Brillouin-distributed sensors the investigation on Brillouin scattering effects in multimode fibers (MMFs) was performed on a low-loss perfluorinated graded-index polymer optical fiber (PFGI-POF). The obtained results were compared with those of a standard graded-index multimode (GI-MMF) silica glass optical fiber (GOF).
This study confirms the relevance of the adaptation of the measurement system components to the use of the multimode sensor fibers. In addition, due to mode coupling effects occurring in the tested POF itself, the results show differences in the yield of the components adaptation in the sensory implementation of the two kinds of the tested optical fibers.
In this paper, we present a study aimed at characterizing the optimal fiber optic components for Brillouin sensing in multimode fibers. For this purpose the use of single-mode and multimode circulators as well as couplers typically used in the Brillouin measurement setups was investigated. On the one hand the undesired coupling losses between conventional fiber optic measurement system components and a multimode sensor fiber can be overcome by replacing the single-mode components with their own multimode equivalents. On the other hand the use of multimode fiber optic circulators and multimode couplers affects the mode distribution of laser light which can impair the measurement signal backscattered in the multimode sensor fibers. In view of an increasing interest in high strain measurements using polymer optical fibers (POFs) as Brillouin-distributed sensors the investigation on Brillouin scattering effects in multimode fibers (MMFs) was performed on a low-loss perfluorinated graded-index polymer optical fiber (PFGI-POF). The obtained results were compared with those of a standard graded-index multimode (GI-MMF) silica glass optical fiber (GOF).
This study confirms the relevance of the adaptation of the measurement system components to the use of the multimode sensor fibers. In addition, due to mode coupling effects occurring in the tested POF itself, the results show differences in the yield of the components adaptation in the sensory implementation of the two kinds of the tested optical fibers.
In this paper perfluorinated graded-index polymer optical fibers are characterized with respect to the influence of relative humidity changes on spectral transmission absorption and Rayleigh backscattering. The hygroscopic and thermal expansion coefficient of the fiber are determined to be CHE = (7.4 +/- 0.1) 10^-6 %r.h.^-1 and CTE = (22.7 +/- 0.3) 10^-6 K^-1, respectively. The influence of humidity on the Brillouin backscattering power and linewidth are presented for the first time to our knowledge. The Brillouin backscattering power at a pump wavelength of 1319 nm is affected by temperature and humidity. The Brillouin linewidth is observed to be a function of temperature but not of humidity. The strain coefficient of the BFS is determined to be CS = (146.5 +/- 0.9) MHz/% for a wavelength of 1319 nm within a strain range from 0.1 % to 1.5 %. The obtained results demonstrate that the humidity-induced Brillouin frequency shift is predominantly caused by the swelling of the fiber over-cladding that leads to fiber straining.