Messung und Simulation des Inertgaseinflusses auf Explosionsgrenzen bei erhöhten Anfangsdrücken
(2001)
At Juelich Research Center the prototype of an alkaline 120-bar electrolyser has been developed and built. Constructive and process-engineering measures must be taken to ensure the safe operation of such facilities. Potential hazards occur due to the high operating pressure in conjunction with the reactivity of the product gases and the electrolyte. First of all, the operating mode and technical features of the Juelich high-pressure electrolyser will be dealt with. Within the framework of a parametric study, the potential for weight reduction of the prototype while observing the rules for pressure vessel design will be shown. The Federal Institute for Materials Research and Testing in Berlin has performed measurements concerning the explosion limits of H2/O2 mixtures at different temperatures and pressures up to 200 bars. At an electrolysis test rig of IWV-3, which can also be operated up to 200 bars, investigations were carried out concerning the gas composition on the H2 and O2 path under different operating conditions. These measurement series were compared to the explosion limits determined and evaluated to derive safety measures required for the operation of high-pressure electrolysers.
Messung und Simulation des Inertgaseinflusses auf Explosionsgrenzen bei erhöhten Anfangsdrücken
(2001)
International and European dangerous substances and dangerous goods regulations refer to the standard ISO 10156 (1996). This standard includes a test method and a calculation procedure for the determination of the flammability of gases and gas mixtures in air. The substance indices for the calculation, the so called Tci values, which characterise the fire potential, are provided as well. These ISO Tci values are derived from explosion diagrams of older literature sources which do not take into account the test method and the test apparatus. However, since the explosion limits are influenced by apparatus parameters, the Tci values and lower explosion limits, given by the ISO tables, are inconsistent with those measured according to the test method of the same standard. In consequence, applying the ISO Tci values can result in wrong classifications. In this paper internationally accepted explosion limit test methods were evaluated and Tci values were derived from explosion diagrams. Therefore, an open vessel method with flame propagation criterion was favoured. These values were compared with the Tci values listed in ISO 10156. In most cases, significant deviations were found. A detailed study about the influence of inert gases on flammability is the objective of Part 2.
Ternary systems, which contain flammable gas, inert gas and air, were studied in order to give the user an evaluation of the ISO 10156 calculation method for the flammability of gas mixtures. While in Part 1 of this article the fire potential of flammable gases was the focal point, the influence of inert gases on the flammability of gas mixtures was studied in Part 2. The inerting capacity of an inert gas is expressed by the dimensionless K value, the so-called coefficient of nitrogen equivalency. The experimental determination of K values is demonstrated by using explosion diagrams. The objective of this study was to compare the estimated results, given by ISO 10156, with measurements of explosion ranges based on the German standard DIN 51649-1, given by CERN and CHEMSAFE. The comparison shows that ISO 10156, Table 1, supplies conservative K values, which can be regarded as safe in all cases. Nevertheless, in a number of cases ISO underestimates the inerting capacity, so that non-flammable gas mixtures are considered flammable.
According to international standards several safety characteristics of dusts are determined in the 20-Lsphere (also known as SIWEK Chamber). Dust cloud ignition is carried out using pyrotechnical igniters.
Due to various disadvantages of such igniters the need for alternative ignition sources arises again and again. An alternative ignition source could be the so called 'exploding wire' or 'fuse wire'. The paper presents test results of a comparative study between both ignition sources for the determination of the safety characteristics Maximum Explosion Pressure and Maximum Explosion Pressure Rise of five selected dusts in the 20-L-sphere. In addition to that the ignition mechanisms of both ignition sources were analysed by high speed camera recordings and the ignition energy was determined with electric and calorimetric recordings.
The Ignition Temperature (IT) of stoichiometric tetrafluoroethylene–air mixtures on hot walls was determined in a 3-dm³-reactor. Tests at elevated pressure conditions were performed, namely at 5, 15 and 25 bar(a), showing a decrease of the IT with the initial pressure. Furthermore, the measured ignition temperatures of stoichiometric tetrafluoroethylene–air mixtures were lower than the ignition temperatures required for the decomposition pure tetrafluoroethylene (Minimum Ignition Temperature of Decomposition, MITD) reported in previous works.
Equations from the Semenov thermal explosion theory on spontaneous ignition were used to identify approximate combustion kinetics of tetrafluoroethylene from the experimental results. The determined kinetics was used for the prediction of the IT of stoichiometric tetrafluoroethylene-air by simplified calculation methods. A very good agreement with the experimental results was observed.
There is a lack of data on the self-ignition behaviour of tetrafluoroethylene (TFE) in industrial sized
equipment. In order to assess the tendency of TFE for
decomposition in large scale vessels, , a facility was
designed and constructed. Tests were
carried out in a cylindrical reactor with a volume of 100 L with initial
pressures of 5 and 10 bar(a). The effect of the reacto
r adjustment (vertical or horizontal) was taken into
account. The current work describes the test set
up and summarizes the experimental results achieved.
Furthermore, this paper reports on a numerical model for
the prediction of the self
-heating of TFE in closed
vessels, which was previously developed for small scale reactors and has been here validated for larger
dimensions with the experiments performed in the new facility.