There is a lack of data on the self-ignition behaviour of tetrafluoroethylene in industrial sized equipment. Therefore, a facility was designed and constructed for the determination of the Minimum Ignition Temperature of Decomposition of tetrafluoroethylene in a cylindrical reactor with a volume of 100 dm3. Tests with initial pressures of 5 and 10 bar(a) were performed. The Minimum Ignition Temperature of Decomposition of tetrafluoroethylene was observed to decrease with the initial pressure, in agreement with previous experiments with small scale cylindrical vessels. This paper describes the test set-up und gives an overview of the achieved experimental results. In particular the effect of the reactor orientation (vertical or horizontal) is discussed. Furthermore, simplified equations from the Semenov thermal explosion theory are used to attempt extrapolations of previous and current data on the Minimum Ignition Temperature of Decomposition of tetrafluoroethylene to other vessel volumes or initial pressures. Moreover, the experimental data are plotted together against the heated volume to heated surface ratio, which should provide a better extrapolation to other vessel dimensions by taking into account that the efficiency of the dispersion of the heat generated by the reaction is different for two reactors with the same volume but different diameter. Finally, simplified methods for predicting the Minimum Ignition Temperature of Decomposition of tetrafluoroethylene presented previously by the authors are validated for large scale reactors with the experimental data collected within the current work.
Es wurde ein Verfahren zur Berechnung von Explosionsgrenzen ethylenoxidhaltiger Gasphasen in Sterilisatoren entwickelt. Mit Hilfe der Software GasEq® und des neu entwickelten Makros SterEx für MS-Excel® lassen sich die Explosionsgrenzen für Gemische aus Ethylenoxid, Luft und Inertgasen bei Temperaturen zwischen 20°C und 100°C sowie 0,4 bar und 1,0 bar berechnen. Somit ist es schnell möglich, sichere Betriebsbedingungen für Sterilisationsprozesse mit Ethylenoxid festzulegen. Das halbempirische Modell basiert auf der Annahme konstanter Flammentemperaturprofile an den Explosionsgrenzen in Abhängigkeit der EO-Konzentration für verschiedene Gemische. Durch systematische Zündversuche wurden Explosionsgrenzen für Gemische aus Ethylenoxid, Stickstoff, Kohlenstoffdioxid, Wasserdampf und Luft zur Bestimmung von Modellparametern und zur Validierung des Verfahrens bestimmt. Um die Prozessbedingungen in Sterilisatoren möglichst genau zu simulieren, wurden die Versuche in einem geschlossenen Autoklav in Anlehnung an DIN EN 1839-B durchgeführt. Berechnungen der Explosionsgrenzen von Prozessgasgemischen mit SterEx ergeben eine gute Übereinstimmung mit experimentell ermittelten Werten.
----------------------------------------------------------------------------------------------------------------------------------
A calculation method for flammability limits of gas phases with ethylene oxide in sterilisers was developed. Using the Software GasEq® and the newly developed Makro SterEx for MS-Excel®, flammability limits of mixtures with ethylene oxide, air and inert gases at temperatures between 20°C and 100°C and pressures between 0.4 bar and 1.0 bar can be calculated. This method can be used to easily determine safe operating conditions. The used semi-empirical model is based upon the assumption of constant flame temperature profiles at the flammability limits subject to the EO-concentration for different mixtures. To collect model parameters and to validate the model, several experiments with mixtures of ethylene oxide, nitrogen, carbon dioxide, water vapour and air were carried out to determine flammability limits. To simulate the structural conditions of sterilisers, the experiments were conducted in accordance to DIN EN 1839-B in a closed autoclave with temperatures and pressures relevant for sterilisation processes. The calculation of flammability limits of process gas mixtures with SterEx provides good agreement with flammability limits that were determined in experiments.
For the determination of safety characteristics of gases, vapors and dusts different types of ignition sources are used in international standards and guidelines. The paper presents test results of a comparative calorimetric and visual study between four different types of ignition sources. The ignition procedures were analyzed visually with a high-speed camera and electric recordings. In addition to that, the influence of the electrode-orientation, -distance as well as ignition energy on the reproducibility of the exploding wire igniter was tested.
The exploding wire is already in use for standardized determination of safety characteristics of gases, first tests on the suitability of the exploding wire igniter for dust testing have been carried out but are not standardized yet. Using the exploding wire, the ignition energy can be varied from 2 J to 10 000 J (2 x 5000 J) and thus it could be used for gases, vapors, dusts and hybrid mixtures. Moreover it can be used at high initial pressures and it is the only ignition source with an easily measurable ignition energy release. Furthermore, it does not introduce another chemical reaction into the system.
Finally, a proposal for a standard ignition source for explosion tests on hybrid mixtures is derived from the test results.
The classification of flammable gas mixtures is based on either testing or calculation methods proposed by the revised international standard ISO 10156. This standard is used for classification of physical hazards in Chapters 2.2 and 2.4 of the UN Globally Harmonized System of Classification and Labelling of Chemicals (GHS) and in the UN Recommendations on Transport of Dangerous Goods (TDG). The test methods of flammability and oxidizing potential in this standard were developed by BAM. Earlier versions of this standard are not based on triangular diagrams and on the reference combustible substance 'ethane'. The old material characteristics, especially in case of oxidizing potential, are based mostly on practical experience without any quantifiable test results. First time it is possible to compare experimental results from the CHEMSAFE database with the newly developed calculation method. In this paper the basic principles of the calculation methods are presented and the methods are validated by examples. A comparison of experimental flammability data with classification results gained by the calculation methods of ISO 10156 is demonstrated.
Many industrial processes are run at non-atmospheric conditions (elevated temperatures and pressures, other oxidizers than air). To judge whether and if yes to what extent explosive gas(vapor)/air mixtures will occur or may be generated during malfunction it is necessary to know the safety characteristic data at the respective conditions. Safety characteristic data like Explosion limits, are depending on pressure, temperature and the oxidizer. Most of the determination methods are standardized for ambient conditions.
In order to obtain determination methods for non-atmospheric conditions, particularly for higher initial pressures, reliable ignition criteria were investigated. Ignition tests at the explosion Limits were carried out for mixtures of methane, propane, n-butane, n-hexane, hydrogen, ammonia and acetone in air at initial pressures up to 20 bar. The tests have been evaluated according to different ignition criteria: visual flame propagation, temperature and pressure rising. It could be shown that flame propagation and occasionally self-sustained combustion for several seconds occurred together with remarkable temperature rise, although the pressure rise was below 3%. The results showed that the combination of a pressure rise criterion of 2% and a temperature rise criterion of 100 K seems to be a suitable ignition criterion for the determination of explosion limits and limiting oxidizer concentration at higher initial pressures and elevated temperatures. The tests were carried out within the framework of a R&D project founded by the German Ministry of Economics and Technology.
Für die sicherheitstechnische Beurteilung von Sterilisationsprozessen wurden die Explosionsgrenzen von Gasgemischen aus Ethylenoxid, Inertgas und Luft experimentell bestimmt. Die Messungen sind mit Stickstoff, Kohlenstoffdioxid und Wasserdampf bei 20 und 100 °C sowie bei 0,4 und 1,0 bar durchgeführt worden. Mit Hilfe der Daten wurde ein halbempirisches Modell entwickelt, mit dem die Explosionsfähigkeit von Prozessgasgemischen berechnet werden kann.
The hazardous potential of accidental heavy gas releases, especially those involving flammable and toxic gases, is widely known. In order to predict the area in which these gases are in hazardous concentrations, an estimation of the dispersion of these gases must be carried out. While the hazardous area for flammable heavy gases is determined by the lower flammability limit (ca. >1 vol%), the release of toxic heavy gases can result in a much larger hazardous area. Toxic gases, even in very low concentrations (ca. <3,000 ppm), have the potential to be highly damaging. State-of-the-art dispersion models, such as the VDI Guideline 3783, can be used to estimate the dispersion of heavy gases. However, VDI 3783 gives no method for the prediction of the height and width of a heavy gas cloud, which are both required for quantitative risk analysis as well as for a possible coupling of a Lagrangian particle model with the VDI 3783 heavy gas dispersion model. Therefore, further calculation methods were used to describe these dimensions and were evaluated against experimental studies of the length, width, and height of the heavy and neutral gas field. In addition to that the influence of the source height on the heavy gas dispersion was also examined