Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (121)
- Vortrag (49)
- Posterpräsentation (16)
- Beitrag zu einem Tagungsband (3)
- Buchkapitel (2)
- Sonstiges (1)
Schlagworte
- Immunoassay (49)
- ELISA (36)
- Biosensoren (15)
- Antikörper (14)
- Carbamazepine (12)
- Abwasser (11)
- Antibody (10)
- Biomarkers (9)
- Biosensor (9)
- LC-MS/MS (9)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (74)
- 1.8 Umweltanalytik (74)
- 6 Materialchemie (8)
- 1.9 Chemische und optische Sensorik (7)
- 6.1 Oberflächen- und Dünnschichtanalyse (5)
- P Präsident (5)
- P.0 Präsident und andere (5)
- 1.5 Proteinanalytik (3)
- 6.3 Strukturanalytik (3)
- 1.0 Abteilungsleitung und andere (2)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (49)
The main goal of the study was to evaluate the catalytic activity of two hybrid nanocatalysts consisting in Fe3O4 nanoparticles modified with either chitosan (CS) or polyethylene glycol (PEG)/ferrous oxalate (FO), and further deposited on solid substrate as thin films. X-ray powder diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy, and scanning electron microscopy (SEM) were employed for the structural and morphological characterizations of the heterogeneous catalysts. The Degradation kinetic studies of two reactive azo dye (Reactive Black 5 (RB5) and Reactive Yellow 84 (RY84)) as well as Bisphenol A (BPA) solutions were carried out using Fenton-like oxidation, in the presence of different concentrations of H2O2, at initial near-neutral pH and room temperature. The results indicated that a low amount of catalytic material (0.15 g/L), deposited as thin film, was able to efficiently trigger dye degradation in solution in the presence of 6.5mmol/LH2O2 for RB5 and of only 1.6mmol/LH2O2 in the case of BPA and RY84. In the presence of complex matrices such asWWTP waters, the removal of BPAwas low (only 24% for effluent samples). Our findings recommend the studied immobilized nanocatalysts as promising economical tools for the pretreatment of wastewaters using advanced oxidation processes (AOPs).
Ocean acidification and increasing discharges of pharmaceutical contaminants into aquatic systems are among key and/or emerging drivers of environmental change affecting marine ecosystems. A growing body of evidence demonstrates that ocean acidification can have direct and indirect impacts on marine organisms although combined effects with other stressors, namely with pharmaceuticals, have received very little attention to date. The present study aimed to evaluate the impacts of the pharmaceutical drug Carbamazepine and pH 7.1, acting alone and in combination, on the clamScrobicularia plana. For this, a long-termexposure (28 days)was conducted and a set of oxidative stress markers was investigated. The results obtained showed that S. plana was able to develop mechanisms to prevent oxidative damage when under low pH for a long period, presenting higher survival when exposed to this stressor compared to CBZ or the combination of CBZ with pH 7.1. Furthermore, the toxicity of CBZ on S. plana was synergistically increased under ocean acidification conditions (CBZ + pH 7.1): specimens survival was reduced and oxidative stress was enhanced when compared to single exposures. These findings add to the growing body of evidence that ocean acidification will act to increase the toxicity of CBZ to marine organisms,which has clear implications for coastal benthic ecosystems suffering chronic pollution from pharmaceutical drugs.
The chemistry of caffeine
(2012)
The use of magnetic materials as heterogeneous catalysts has attracted increasing attention in the last years since they proved to be promising candidates for water treatment. In the present study, two types of surface-modified magnetite (Fe3O4) nanoparticles, coated with non-hazardous naturally occurring agents—either tannic acid (TA) or dissolved natural organic matter—were evaluated as magnetic heterogeneous catalysts. Chemical synthesis (co-precipitation) was chosen to yield the nanocatalysts due to its well-established simplicity and efficiency. Subsequently, the properties of the final products were fully assessed by various characterization techniques. The catalytic activity in heterogeneous oxidation of aqueous solutions containing a model pollutant, Bisphenol A (BPA), was comparatively studied. The effect of operational parameters (catalyst loading, H2O2 dosage, and UV light irradiation) on the Degradation performance of the oxidation process was investigated. The optimum experimental parameters were found to be 1.0 g/L of catalysts and 10 mM H2O2, under UV irradiation. The highest mineralization rates were observed for Fe3O4-TA catalyst. More than 80 % of BPA was removed after 30 min of reaction time under the specified experimental conditions. The obtained results showed that the two catalysts studied here are suitable candidates for the removal of pollutants in wastewaters by means of heterogeneous reaction using a green sustainable treatment method.
Zeolitic imidazolate framework (ZIF) hybrid fluorescent nanoparticles and ZIF antibody conjugates have been synthesized, characterized, and employed in lateral-flow immunoassay (LFIA). The bright fluorescence of the conjugates and the possibility to tailor their mobility gives a huge potential for diagnostic assays. An enzyme-linked immunosorbent assay (ELISA) with horseradish peroxidase (HRP) as label, proved the integrity, stability, and dispersibility of the antibody conjugates, LC-MS/MS provided evidence that a covalent link was established between these metal-organic frameworks and lysine residues in IgG antibodies.
For many heterogeneous sensor applications as well as the synthesis of hapten antigens to produce antibodies, protein conjugates of the target substance are essential. A requirement is that the target substance already offers or is modified to contain a functionality that allows for coupling to a protein, that is, an amino acid residue. Ideally, to avoid shielding of the compound by the carrier protein, a sufficient distance to the protein surface should be provided. With its carboxyl function diclofenac (DCF) allows for direct binding to lysine residues after in situ synthesis of the NHS ester. One problem is that diclofenac as free acid tends to autocondensation, which results in low yields. Here we describe the 'insertion' of a C6 spacer via synthesis of the amide with 6-aminohexanoic acid. To carry out the reaction in solution, first the methyl ester of the amino acid had to be produced. Due to otherwise low yields and large cleaning efforts, solid-phase synthesis on Fmoc Ahx Wang resin is recommended. The crude product is mainly contaminated by cleavage products from the resin which were removed by chromatography. The structure of the highly pure hapten was completely determined by nuclear magnetic resonance (NMR) spectroscopy.
Studies on the development of antibodies for the highly hydrophobic plasticizers DINCH and DEHT
(2018)
Diisononylcyclohexane-1,2-dicarboxylate (DINCH) and di-2-ethylhexyl terephthalate (DEHT), two of the most important substitutes for phthalate plasticizers, are used for a wide range of applications. Consequently, an increasing occurrence in urine and environmental samples is reported. Reliable and fast analytical methods for the quantification of these plasticizers are needed. So far, mainly GC-MS or LC-MS methods are used. We aimed to develop the first antibodies and immunoassays allowing for high-throughput analysis of samples. We designed two DINCH hapten structures and one DEHT hapten structure and employed hapten-protein conjugates for the immunization of rabbits. Sensitive competitive enzyme-linked immunosorbent assays (ELISAs) against each hapten using the produced polyclonal antibodies were established. Yet, binding of DINCH to the respective antibodies was not observed in neither direct nor indirect assay formats, even when using protein conjugates with the heterologous haptens and different carrier proteins in the indirect format. The use of surfactants and solvents in the sample buffer did not result in recognition of the plasticizers. Also, no binding of DEHT in ELISA employing the respective antibodies was detected. We speculate that the production of antibodies against these highly hydrophobic molecules is not possible via our route, however a different hapten design could overcome this obstacle.
Sulfamethoxazol (SMX),a sulfonamide, is a widely used bacteriostatic antibiotic and therefore a promising marker for the entry of anthropogenic Pollution in the environment. SMX is frequently found in wastewater and surface water. This study presents the production of high affinity and selective polyclonal antibodies for SMX and the development and Evaluation of a direct competitive enzyme-linked immunosorbent assay(ELISA)for the quantification of SMX in environmental watersamples. The crystal structures of the cross-reacting compounds sulfamethizole, N4-acetyl-SMX andsuccinimidyl-SMX were determined by x-ray diffraction aiming to explain their high cross-reactivity. These crystal structures are described for the first time. The quantification range of the ELISA is 0.82–63 µg/L. To verify our results, the SMX concentration in 20 environmental samples,including wastewater and surfacewater,was determined by ELISA and tandem mass spectrometry(MS/MS).A good Agreement of the measured SMX concentrations was found with average recoveries of 97–113%for the results of ELISA compared to LC-MS/MS.
Sulfamethoxazol (SMX),a sulfonamide, is a widely used bacteriostatic antibiotic and therefore a promising marker for the entry of anthropogenic Pollution in the environment. SMX is frequently found in wastewater and surface water. This study presents the production of high affinity and selective polyclonal antibodies for SMX and the development and Evaluation of a direct competitive enzyme-linked immunosorbent assay(ELISA)for the quantification of SMX in environmental watersamples. The crystal structures of the cross-reacting compounds sulfamethizole, N4-acetyl-SMX andsuccinimidyl-SMX were determined by x-ray diffraction aiming to explain their high cross-reactivity. These crystal structures are described for the first time. The quantification range of the ELISA is 0.82–63 µg/L. To verify our results, the SMX concentration in 20 environmental samples,including wastewater and surfacewater,was determined by ELISA and tandem mass spectrometry(MS/MS).A good Agreement of the measured SMX concentrations was found with average recoveries of 97–113%for the results of ELISA compared to LC-MS/MS.
Sorption of atrazine on soils subjected to three different organic amendments was measured using a batch equilibrium technique. A higher KF value (2.20 kg-1(mg L-1)-N) was obtained for soil fertilized with compost, which had a higher organic matter (OM) content. A correlation between the KFOC values and the percentage of aromatic carbon in OM was observed. The highest KFOC value was obtained for the soil with the highest aromatic content. Higher aromatic content results in higher hydrophobicity of OM, and hydrophobic interactions play a key role in binding of atrazine. On the other hand, the soil amended with farmyard manure had a higher content of carboxylic units, which could be responsible for hydrogen bonding between atrazine and OM. Dominance of hydrogen bonds compared to hydrophobic interactions can be responsible for the lower desorption capacity observed with the farmyard manure soil. The stronger hydrogen bonding can reduce the leaching of atrazine into drinking water resources and runoff to rivers and other surface waters.
The transport and fate of hydrophobic organic contaminants in the environment involve complex phenomena that are influenced by many processes that include sorption by soil components. Sorption behavior of EE2 molecules onto different soil samples was studied and results correlated with the content and type of organic matter present. The highest Κ value, among all soils presented in this study, was obtained for soil fertilized with compost (1.22) which presented the highest organic carbon content. Also the sorption behavior depends greatly on the soil specific organic matter characteristics. A strong positive correlation was observed between aromatic and carboxylic units and ΚOC values. The results also suggested an association of the EE2 aromatic nuclei face to face with the surface and/or another EE2 molecule and also sorbentsorbate interactions due to hydrogen or covalent bonding, likely to occur due to the presence of phenolic function at C-3 and hydroxyl function at C-17 of the EE2 molecules that can react with carboxylic functional groups of soil organic matter. The stronger EE2 sorbs to soil organic matter lower is the leaching into drinking water resources and runoff to rivers and surface water, minimizing its residual toxicity.
Singlet oxygen generation potential of two novel free-base-porphyrin photocatalysts was investigated. The freebase-porphyrin-sensitized Fe3O4 magnetic nanoparticles (MNPs) were tested for the degradation of the model pollutant Bisphenol A (BPA) in aqueous solution, for the first time. MNPs with either cubic or spherical shape were synthesized using the sonochemical approach, followed by sensitizing with photoactive 4,4′,4′′,4′′′- (Porphine-5,10,15,20-tetrayl)tetrakis(benzoic acid) (TCPP). The resulted photocatalysts were characterized in detail by scanning and transmission electron microscopy, Brunauer–Emmett–Teller analysis, spectral techniques and vibrating sample magnetometry. The electron spin resonance experiments have confirmed the high activity of the photocatalysts through the efficient formation of singlet oxygen in solution. The optimum operational parameters for BPA degradation were established as follows: 1.0 μmol L−1 BPA, 1.0 g L−1 of photocatalyst, 100 μmol L−1 H2O2, under UVA irradiation. In these conditions, the results for both photocatalysts revealed that after only 10 min of reaction, over 64% and ca. 90% of BPA have been removed from solution in the absence and presence of H2O2, respectively. Whereas after 60 minutes of treatment, only 24% of BPA in real wastewater effluent samples were removed under UVA irradiation in the absence of H2O2, showing the high complexity of real wastewater. Moreover, both photocatalysts were successfully used for BPA removal in three consecutive runs, without significant loss of catalytic features.
This study focused on quantitative detection of cocaine on Euro banknotes in Germany. A sensitive direct competitive immunoassay was developed and optimized with a limit of detection (LOD) of 5.6 ng/L. Exhaustive cocaine extraction by solvent was tested using different methanol concentrations and buffered solutions. Crossreactivity studies were performed to determine the degree of interference of cocaine metabolites with the immunoassay. Sixty-five Euro banknotes obtained from different districts in Berlin were evaluated. A 100% contamination frequency with cocaine was detected. A comparison between the amount of cocaine extracted by cotton swabbing of one square centimeter of the banknote showed a good correlation for lower contamination levels. This assay showed high sensitivity of detecting pg of cocaine per 1 cm2 of one banknote by swabbing 1 cm2: 0, 14, and 21 pg/cm2. Moreover, three notes of different denominations revealed high cocaine concentration; 1.1 mg/note, and twice 55 μg/note.
In Coastal Systems, pollutants as pharmaceutical drugs exert changes from the molecular to the organism level in marine bivalves. Besides pollutants, Coastal Systems are prone to changes in environmental Parameters, as the alteration of salinity values because of Climate Change. Together, these Stressors (pharmaceutical drugs and salinity changes) can exert different threats than each Stressor acting individually; for example, salinity can change the physical-chemical properties of the drugs and/or the sensitivity of the organisms to them. However, limited Information is available on this subject, with variable results, and for this reason, this study aimed to evaluate the impacts of salinity changes (15,25 and 35) on the effects of the antiepileptic carbamazepine (CBZ, 1 (ig/L) and the antihistamine cetirizine (CTZ, 0.6 pg/L), when acting individually and combined (CBZ + CTZ), in the edible clam Ruditapes philippinarum. After 28 days ofexposure, drugs concentrations, bioconcentration factors and biochemical parameters, related to clam's metabolic caparity and oxidative stress were evaluated. The results showed that dams under low salinity suffered more changes in metabolic, antioxidant and biotransformation activities, in comparison with the remaining salinities under study. However, limited impacts were observed when comparing drug effects at low salinity. Indeed, it seemed that CTZ and CBZ + CTZ, under high salinity (salinity 35) were the worst exposure conditions for the dams, since they caused higher leveis of cellular damage. It Stands out that salinity changes altered the impact of pharmaceutical drugs on marine bivalves.
In coastal systems, organisms are exposed to amultitude of stressors whose interactions and effects are poorly studied. Pharmaceutical drugs and Climate Change consequences, such as lowered pH, are examples of stressors affecting marine organisms, as bivalves. Although a vast literature is available for the effects of these stressors when acting individually, very limited information exists on the impacts that the combination of both can have on marine bivalves. For this reason, this study aimed to evaluate the impacts of a simulated ocean acidification scenario (control pH, 8.0; lowered pH, pH 7.6) on the effects of the antiepileptic carbamazepine (CBZ, 1 μg/L) and the antihistamine cetirizine (CTZ, 0.6 μg/L), when acting individually and combined (CBZ + CTZ), on the edible clam Ruditapes philippinarum. After 28 days of exposure, drug concentrations, bioconcentration factors and biochemical parameters related to the clams' metabolic capacity and oxidative stress were evaluated. The results showed that R. philippinarum clams responded differently to pharmaceutical drugs depending on the pH tested, influencing both bioconcentration and biological responses. In general, drug combined treatments showed fewer impacts than drugs acting alone, and acidification seemed to activate at a higher extension the elimination processes that were not activated under control pH. Also, lowered pH per se exerted negative impacts (e.g., cellular damage) on R. philippinarum and the combination with pharmaceutical drugs did not enhance the toxicity.
Two iron-based molten salts comprising an imidazolium and Schiff base were evaluated as catalysts for removal of carbamazepine (CBZ) from water. The catalysts were fully characterized using scanning electron microscopy (SEM), energy-dispersive X-ray spectrometry (EDX), nuclear magnetic resonance spectroscopy (NMR), electrospray ionisation–mass spectrometry (ESI–MS), differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR) and nitrogen adsorption–desorption isotherms (BET). Additionally, the formation of photo-sensitized oxygen was investigated by spin-trapping using electron spin resonance (ESR). The catalytic activity in heterogeneous oxidation of the micropollutant (CBZ) was also evaluated. The effects of catalyst loading, pH, H2O2 dosage and UV light on the oxidation of the selected compound were investigated. After 15 min of UVA irradiation in the presence of 200 μM H2O2, CBZ was completely removed over both catalysts.
The non-steroidal anti-inflammatory drug (NSAID) diclofenac (DCF) is an important environmental contaminant occurring in surface waters all over the world, because, after excretion, it is not adequately removed from wastewater in sewage treatment plants. To be able to monitor this pollutant, highly efficient analytical methods are needed, including immunoassays. In a medical research project, monoclonal antibodies against diclofenac and its metabolites had been produced. Based on this monoclonal anti-DCF antibody, a new indirect competitive enzyme-linked immunosorbent assay (ELISA) was developed and applied for environmental samples. The introduction of a spacer between diclofenac and the carrier protein in the coating conjugate led to higher sensitivity. With a test midpoint of 3 mg L−1 and a measurement range of 1–30 mg L−1, the system is not sensitive enough for direct analysis of surface water. However, this assay is quite robust against matrix influences and can be used for wastewater. Without adjustment of the calibration, organic solvents up to 5%, natural organic matter (NOM) up to 10 mg L−1, humic acids up to 2.5 mg L−1, and salt concentrations up to 6 g L−1 NaCl and 75 mg L−1 CaCl2 are tolerated. The antibody is also stable in a pH range from 3 to 12. Cross-reactivity (CR) of 1% or less was determined for the metabolites 40-hydroxydiclofenac (40-OH-DCF), 5-hydroxydiclofenac (5-OH-DCF), DCF lactam, and other NSAIDs. Relevant cross-reactivity occurred only with an amide derivative of DCF, 6-aminohexanoic acid (DCF-Ahx), aceclofenac (ACF) and DCF methyl ester (DCF-Me) with 150%, 61% and 44%, respectively. These substances, however, have not been found in samples. Only DCF-acyl glucuronide with a cross-reactivity of 57% is of some relevance. For the first time, photodegradation products were tested for cross-reactivity. With the ELISA based on this antibody, water samples were analysed. In sewage treatment plant effluents, concentrations in the range of 1.9–5.2 mg L−1 were determined directly, with recoveries compared to HPLC-MS/MS averaging 136%.
Concentrations in lakes ranged from 3 to 4.4 ng L−1 and were, after pre-concentration, determined with an average recovery of 100%
This report focuses on the characterization of CD4 expression level in terms of equivalent number of reference fluorophores (ERF). Twelve different flow cytometer platforms across sixteen laboratories were utilized in this study. As a first step the participants were asked to calibrate the fluorescein isothiocyanate (FITC) channel of each flow cytometer using commercially available calibration standard consisting of five populations of microspheres. Each population had an assigned value of equivalent fluorescein fluorophores (EFF denotes a special case of the generic term ERF with FITC as the reference fluorophore). The EFF values were assigned at the National Institute of Standards and Technology (NIST). A surface-labelled lyophilized cell preparation was provided by the National Institute of Biological Standards and Control (NIBSC), using human peripheral blood mononuclear cells (PBMC) pre-labeled with a FITC conjugated anti-CD4 monoclonal antibody. Three PBMC sample vials, provided to each participant, were used for the CD4 expression analysis. The PBMC are purported to have a fixed number of surface CD4 receptors. On the basis of the microsphere calibration, the EFF value of the PBMC samples was measured to characterize the population average CD4 expression level of the PBMC preparations. Both the results of data analysis performed by each participant and the results of centralized analysis of all participants' raw data are reported. Centralized analysis gave a mean EFF value of 22,300 and an uncertainty of 750, corresponding to 3.3% (level of confidence 68%) of the mean EFF value. The next step will entail the measurement of the ERF values of the lyophilized PBMC stained with labels for other fluorescence channels. The ultimate goal is to show that lyophilized PBMC is a suitable biological reference cell material for multicolor flow cytometry and that it can be used to present multicolor flow cytometry measurements in terms of ABC (antibodies bound per cell) units.
A surface-labeled lyophilized lymphocyte (sLL) preparation has been developed using human peripheral blood mononuclear cells prelabeled with a fluorescein isothiocyanate conjugated anti-CD4 monoclonal antibody. The sLL preparation is intended to be used as a reference material for CD4+ cell counting including the development of higher order reference measurement procedures and has been evaluated in the pilot study CCQM-P102. This study was conducted across 16 laboratories from eight countries to assess the ability of participants to quantify the CD4+ cell count of this reference material and to document cross-laboratory variability plus associated measurement uncertainties. Twelve different flow cytometer platforms were evaluated using a standard protocol that included calibration beads used to obtain quantitative measurements of CD4+ T cell counts. There was good overall cross-platform and counting method agreement with a grand mean of the laboratory calculated means of (301.7 ± 4.9) µL-1 CD4+ cells. Excluding outliers, greater than 90% of participant data agreed within ±15%. A major contribution to variation of sLL CD4+ cell counts was tube to tube variation of the calibration beads, amounting to an uncertainty of 3.6%. Variation due to preparative steps equated to an uncertainty of 2.6%. There was no reduction in variability when data files were centrally reanalyzed. Remaining variation was attributed to instrument specific differences. CD4+ cell counts obtained in CCQM-P102 are in excellent agreement and show the robustness of both the measurements and the data analysis and hence the suitability of sLL as a reference material for interlaboratory comparisons and external quality assessment.
Temperature is one factor that influences the performance of immunoassays. Most commonly all incubation steps of the immunoassay are performed at ambient temperature. To systematically study the influence of temperature deviations on assay parameters like signal variation coefficients, limit of detection and measurement range, direct competitive enzyme immunoassays for the determination of two anthropogenic markers, caffeine and carbamazepine, were run at different temperatures above and below room temperature during individual assay steps. The temperature during the competition step had the greatest impact on the assay sensitivity yielding changes in test midpoints by a factor of 10 to 15. For carbamazepine, the test midpoints varied from 36 ng L-1, 108 ng L-1 to 378 ng L-1 employing 4 °C, 21 °C, or 37 °C as incubation temperature, respectively. The edge effect can be minimized resulting in a good plate homogeneity with small variation coefficients, when the assay is performed at ambient temperature.
Enzyme immunoassays with optical detection are amongst the most widely used bioanalytical tools. We defined seven parameters for the quality assessment of immunoassays that were addressed in a systematic study of direct and indirect immunoassays, using the enzymes horseradish peroxidase (HRP) and alkaline phosphatase (AP), the chromogenic substrates 3,3',5,5'-tetramethylbenzidine (TMB) and para-nitrophenyl phosphate, and the fluorescent substrates 3-(4-hydroxyphenyl)propionic acid and 4-methylumbelliferyl phosphate. The same monoclonal antibody against caffeine was used throughout the study. The four quality parameters regarding the standard curve were the test midpoint (sensitivity), the measurement range, the relative dynamic range of the signal, and the goodness of fit of the adjusted four-parameter logistic function. All HRP immunoassays showed a higher sensitivity compared to the AP assays. On the basis of all four criteria, it was established that the direct assay format is superior to the indirect format, the immunoassay using HRP TMB fulfilling all requirements best. In a second step, caffeine concentrations in 24 beverage and cosmetics samples were determined and three more quality parameters were assessed with this application. The direct HRP TMB assay showed one of the best intra- and inter-plate precisions and the best accuracy, defined by the correlation of results with those from the chosen reference method liquid chromatography tandem mass spectrometry (LC-MS/MS). Considering all criteria, HRP TMB seems to be the enzyme substrate system of choice preferably used in the direct assay format.
Carbamazepine (CBZ) is one of the most frequently detected pharmaceuticals in water samples. For the determination of this anthropogenic marker, various immunoassay formats were tested and evaluated in order to identify the most suitable one. For these direct competitive assays, the analyte was labelled with the enzyme horseradish peroxidase (HRP) or alkaline phosphatase (AP), and seven substrates with specific detection properties were used. The quality criteria for the standard curves were fulfilled by all HRP assays and the chemiluminescence AP format. Furthermore, intra- and inter-plate coefficients of variation as a measure of the achievable precision were determined for the samples. The application of the AP assays to surface water was unfeasible due to CBZ concentrations below the quantifiable concentration range. Surface as well as waste water samples could be analyzed with the HRP assays. Here, the HRP assay employing the chromogenic substrate 3,3',5,5'-tetramethylbenzidine yielded the best results.
Carbamazepine (CBZ), an antiepileptic drug, is one of the most commonly detected pharmaceutical drugs in aquatic ecosystems, and is used as a marker of urban pollution. Since CBZ is designed to exert a biological effect, when it reaches aquatic environment high probability exist for toxic effects on non-target organisms. The present study evaluated the acute toxicity of environmentally relevant concentrations of CBZ (0.00, 0.03, 0.30, 3.00, 9.00 µg/L) in the edible clams Venerupis decussata (a native species) and Venerupis philippinarum (an invasive species) collected from the Ria de Aveiro. The effects on both species were assessed through the use of a battery of biomarkers mainly related with health status and oxidative stress. Furthermore, in this work an alternative and promising tool, the direct competitive immunoassay ELISA, for the direct CBZ quantification in clam's tissues, was applied.
The results of the present work showed that CBZ in clam's tissues increased with the exposure concentration and V. decussata gave slightly higher values than V. philippinarum. Although the clams accumulated lower levels of CBZ than the concentration of exposure, these concentrations were enough to impair the health status and induce oxidative stress. However, a different response to CBZ was observed in the two species. While in V. philippinarum the lipid peroxidation levels increased at the highest CBZ concentration (9.00 µg/L), in V. decussata a significant decrease was seen. Moreover, glutathionse S-transferase activity was stimulated in V. decussata and decreased in V. philippinarum. Nevertheless, an induction of glutathione reductase, superoxide dismutase and cytochrome P450 3A4 activities was found in both species as a result of the exposure. The results indicate that, probably, V. philippinarum have a less efficient antioxidant system than V. decussata, and are therefore less capable to neutralize oxidative stress and consequently more sensitive to CBZ. The risk quotient determined for the Ria de Aveiro was higher than 1 indicating that a ecotoxicological risk is suspected. Furthermore, bioaccumulation of CBZ in clams should be taken into consideration since this chemical might be transferred along the food chain and affect non-target organisms.
Portable, antikörperbasierte Analysenverfahren für die Schadstofferfassung im Wasserkreislauf
(2021)
Die Wasseranalytik wird bestimmt von zwei Hauptbedarfen, einerseits der Erfassung der Gewässergüte und Grundwassergüte als Basis für die Bereitstellung einwandfreien Trinkwassers und zum anderen des Monitorings der Wasserqualität in den Prozessen der Wasseraufbereitung und der Abwasserreinigung. Für beide Anwendungsbereiche ist eine laborbasierte Analytik eher hinderlich, werden die Analysenergebnisse doch eigentlich vor Ort benötigt, um etwa Beprobungskampagnen rasch anpassen zu können. Des Weiteren werden die Daten auch schnell benötigt, um zeitnah in die technischen Prozesse einzugreifen. Organische Kontaminanten werden meist über chromatographische Verfahren, häufig gekoppelt mit einer massenspektrometrischen Detektion, in instrumentellen Labormethoden erfasst, und die hochauflösende Massenspektrometrie und die Non-target-Analytik haben viel zum Wissen über das Vorkommen, insbesondere von sogenannten „Emerging Contaminants“, beigetragen, sowie zum Verständnis der beteiligten Eintragspfade und Abbauwege. Moderne, portable Analysenmethoden und insbesondere Sensoren werden zukünftig aber ihren Platz in der Schadstofferfassung im Wasserkreislauf einnehmen. Dies gilt insbesondere für antikörperbasierte Analysenverfahren, da erst diese oft die nötige Selektivität und Sensitivität in die Detektionsmethoden einbringen.
Portable, antikörperbasierte Analysenverfahren für die Schadstofferfassung im Wasserkreislauf
(2021)
Die Wasseranalytik wird bestimmt von zwei Hauptbedarfen, einerseits der Erfassung der Gewässergüte und Grundwassergüte als Basis für die Bereitstellung einwandfrei-en Trinkwassers und zum anderen des Monitorings der Wasserqualität in den Prozes-sen der Wasseraufbereitung und der Abwasserreinigung. Für beide Anwendungsbe-reiche ist eine laborbasierte Analytik eher hinderlich, werden die Analysenergebnisse doch eigentlich vor Ort benötigt, um etwa Beprobungskampagnen rasch anpassen zu können. Desweiteren werden die Daten auch schnell benötigt, um zeitnah in die technischen Prozesse einzugreifen. Organische Kontaminanten werden meist über chromatographische Verfahren, häufig gekoppelt mit einer massenspektrometrischen Detektion, in instrumentelle Labormethoden erfasst und die hochauflösende Massen-spektrometrie und die Non-target-Analytik haben viel zum Wissen über das Vorkom-men, insbesondere von sog. „emerging contaminants“, beigetragen, sowie zum Ver-ständnis der beteiligten Eintragspfade und Abbauwege. Moderne, portable Analy-senmethoden und insbesondere Sensoren werden zukünftig aber ihren Platz in der Schadstofferfassung im Wasserkreislauf einnehmen. Dies gilt insbesondere für anti-körperbasierte Analysenverfahren, da erst diese oft die nötige Selektivität und Sensitivität in die Detektionsmethoden einbringen.
Gastric cancer (GC) is the 3rd deadliest cancer worldwide, due to limited treatment options and late diagnosis. Human epidermal growth factor receptor-2 (HER2) is overexpressed in similar to 20% of GC cases and anti-HER2 antibody trastuzumab in combination with conventional chemotherapy, is recognized as standard therapy for HER2-positive metastatic GC. This strategy improves GC patients' survival by 2-3 months, however its optimal results in breast cancer indicate that GC survival may be improved. A new photoimmunoconjugate was developed by conjugating a porphyrin with trastuzumab (Trast: Porph) for targeted photodynamic therapy in HER2-positive GC. Using mass spectrometry analysis, the lysine residues in the trastuzumab structure most prone for porphyrin conjugation were mapped. The in vitro data demonstrates that Trast: Porph specifically binds to HER2-positive cells, accumulates intracellularly, co-localizes with lysosomal marker LAMP1, and induces massive HER2-positive cell death upon cellular irradiation. The high selectivity and cytotoxicity of Trast: Porph based photoimmunotherapy is confirmed in vivo in comparison with trastuzumab alone, using nude mice xenografted with a HER2-positive GC cell line. In the setting of human disease, these data suggest that repetitive cycles of Trast: Porph photoimmunotherapy may be used as an improved treatment strategy in HER2-positive GC patients.
The synthesis of a novel PS conjugated with bovine and human serum albumin (BSA and HSA) and a monoclonal antibody anti-CD104 is reported, as well as their biological potential against the human bladder cancer cell line UM-UC-3. No photodynamic effect was detected when the non-conjugated porphyrin was used. Yet, when it was coupled covalently with the mAb anti-CD104, BSA and HSA, the resulting photosensitizer conjugates demonstrated high efficacy in destroying the cancer cells, the mAb anti-CD104 efficacy overruling the albumins.
Bile acids are relevant markers for clinical research. This study reports the production of antibodies for isolithocholic acid, the isomer of the extensively studied lithocholic acid. The IgG titer and affinity maturation were monitored during the immunizations of three mice and two rabbits. In both animal models, polyclonal antibodies with a high selectivity and affinity were produced. The development of a direct competitive ELISA with a test midpoint of 0.69 ± 0.05 µg/L and a measurement range from 0.09–15 µg/L is reported. Additionally, the crystal structure of isolithocholic acid is described for the first time.
Contamination of waters with pharmaceuticals is an alarming problem as it may support the evolution of antimicrobial resistance. Therefore, fast and cost-effective analytical methods for potential on-site analysis are desired in order to control the water quality and assure the safety of its use as a source of drinking water. Antibody-based methods, such as the enzyme-linked immunosorbent assay (ELISA), can be helpful in this regard but can also have certain pitfalls in store, depending on the analyte. As shown here for the class of β-lactam antibiotics, hydrolysis of the β-lactam ring is a key factor in the immunochemical analysis as it influences antibody recognition. With the antibody used in this study, the limit of detection (LOD) in the immunoassay could be significantly reduced by hydrolysis for the five tested penicillins, with the lowest LOD for carbenicillin (0.2 nmol/L) and the greatest impact on penicillins G and V (reduction by 85%). In addition to enhanced quantification, our strategy also provides access to information about the degree of hydrolysis in water samples as shown for the most abundant penicillin amoxicillin.
The bivalve Mytilus galloprovincialis collected in the Ria de Aveiro, was selected to evaluate the acute and chronic effects of carbamazepine (CBZ) at environmentally relevant concentrations. CBZ is an antiepileptic drug widely found in the aquatic environment with toxic effects to inhabiting organisms. However, few studies evaluated the acute and chronic toxicity of this drug. The experiment was performed 'by exposing mussels to 0.0, 0.3, 3.0, 6.0 and 9.0 CBZ mu g/L, for 96 h and 28 days. To assess the toxicity of the drug, a battery of biomarkers related to mussels general physiological health status and oxidative stress was applied. CBZ was quantified in mussel tissues by an Enzyme-Linked Immunosorbent Assay (ELISA). The results obtained show that CBZ did not induce oxidative stress. However, our findings,demonstrated that the drug was taken up by mussels even though presenting low bioconcentration factor (BCF) values (up to 2.2). Furthermore, our results demonstrated that after a chronic exposure the physiological parameters, namely the condition and gonadosomatic indices, were negatively affected which may impair organisms' reproductive capacity with consequences to population sustainability.
We report for the first time the formation of sitespecific interstrand cross-linked (ICL) surface-immobilized furanmodified DNA duplexes via singlet oxygen. 1O2, necessary for effecting furan-mediated ICL formation, was produced in situ using methylene blue or a zinc phthalocyanine derivative (TT1) as a photosensitizer. Via surface plasmon resonance spectroscopy, we show that surface ICL was achieved, and a robust link formed that enhances the stability of the 12-mer duplex even after surface regeneration. The described method represents a novel platform technology based on surfaces with addressable and stable DNA duplexes requiring only short oligonucleotides.
Photodegradation of organic pollutants in water by immobilized porphyrins and phthalocyanines
(2016)
New methods for water treatment are required as a result from an increasing awareness in the reduction of the pollution impact in the environment. In the perspective of the photo-oxidation of organic pollutants present in water, the principal incentive for the preparation of heterogeneous photocatalysts is their easy recovery from the reaction mixture, which allows their reuse in successive runs, minimizing the loss of their original photocatalytic properties. Different types of supports can be used in the immobilization of photoactive species, such as porphyrins (Pors) and phthalocyanines (Pcs). This mini-review will consider the different methodologies for the immobilization of Pors and Pcs and their photocatalytic performance in the photodegradation of organic pollutants in water, addressing also their recycling ability in successive water treatments.
The efficiency, relatively low cost and eco-friendly nature of hydrogen peroxide-assisted photocatalysis treatment procedures are significant advantages over conventional techniques for wastewater remediation. Herein, we evaluate the behaviour of g-cyclodextrin (g-CD) immobilised on either bare or chitosan (CS)–functionalised Fe3O4 nanoparticles, for photodegrading Bisphenol A (BPA) in ultrapure water and in real wastewater samples. The BPA removal efficiencies with Fe3O4/g-CD and Fe3O4/CS/g-CD were compared with those of Fe3O4/b-CD, and were monitored under UVA irradiation at near-neutral pH. The addition of H2O2 at low concentrations (15 mmol L-1) significantly increased BPA photodegradation in the presence of each nanocomposite. The highest catalytic activity was shown by both Fe3O4/g-CD and Fe3O4/CS/g-CD nanocomposites (,60 and 27%BPA removal in ultrapure water and real wastewater effluent, respectively). Our findings reveal the superior performance of g-CD-functionalised Fe3O4 relative to that of Fe3O4/b-CD. The use of CD-based nanocomposites as photocatalytic materials could be an attractive option in the pre- or post-treatment stage of wastewaters by advanced oxidation processes before or after biological treatment.
Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a pilot study, CCQM-P216, was coordinated by the Chinese National Institute of Metrology (NIM), National Research Council of Canada (NRC) and the Bureau International des Poids et Mesures (BIPM). Eleven Metrology Institutes or Designated Institutes and the BIPM participated in the first phase of the pilot study (Part 1). The purpose of this pilot study was to develop measurement capabilities for larger proteins using a recombinant humanized IgG monoclonal antibody against Spike glycoprotein of SARS-CoV-2 (Anti-S IgG mAb) in solution. The first phase of the study was designed to employ established methods that had been previously studies by the CCQM Protein Analysis Working Group, involving the digestion of protein down to the peptide or amino acid level. The global coronavirus pandemic has also led to increased focus on antibody quantitation methods. IgG are among the immunoglobulins produced by the immune system to provide protection against SARS-CoV-2. Anti-SARS-CoV-2 IgG can therefore be detected in samples from affected patients. Antibody tests can show whether a person has been exposed to the SARS-CoV-2, and whether or not they potentially show lasting immunity to the disease. With the constant spread of the virus and the high pressure of re-opening economies, antibody testing plays a critical role in the fight against COVID-19 by helping healthcare professionals to identify individuals who have developed an immune response, either via vaccination or exposure to the virus. Many countries have launched large-scale antibody testing for COVID-19. The development of measurement standards for the antibody detection of SARS-CoV-2 is critically important to deal with the challenges of the COVID-19 pandemic. In this study, the SARS-CoV-2 monoclonal antibody is being used as a model system to build capacity in methods that can be used in antibody quantification. Amino acid reference values with corresponding expanded uncertainty of 36.10 ± 1.55 mg/kg, 38.75 ± 1.45 mg/kg, 18.46 ± 0.78 mg/kg, 16.20 ± 0.67 mg/kg and 30.61 ± 1.30 mg/kg have been established for leucine, valine, phenylalanine, isoleucine and proline, respectively. Agreement between nearly all laboratories was achieved for the amino acid analysis within 2 to 2.5 %, with one participant achieving markedly higher results due to a technical issue found in their procedure; this result was thus excluded from the reference value calculations. The relatively good agreement within a laboratory between different amino acids was not dissimilar to previous results for peptides or small proteins, indicating that factors such as hydrolysis conditions and calibration procedures could be the largest sources of variability. Peptide reference values with corresponding expanded uncertainty of 4.99 ± 0.28 mg/kg and 6.83 ± 0.65 mg/kg have been established for ALPAPIEK and GPSVFPLAPSSK, respectively. Not surprisingly due to prior knowledge from previous studies on peptide quantitation, agreement between laboratories for the peptide-based analysis was slightly poorer at 3 to 5 %, with one laboratory's result excluded for the peptide GPSVFPLAPSSK. Again, this level of agreement was not significantly poorer than that achieved in previous studies with smaller or less complex proteins. To reach the main text of this paper, click on Final Report.
The demands for the assessment of water quality are increasing steadily, making it necessary to routinely monitor multiple contaminants in water samples. For this application a hapten microarray was developed. In order to reach the required low detection limits a design of experiments (DoE) approach was used to optimize the assay performance. Here we show that a Box-Behnken design plan is an adequate choice for the straightforward exploration of hapten microarray assay parameters. For both read-out systems studied (fluorophore-labelled detection antibodies or enzymatic signal development followed by reflectometric scan, respectively), it was possible to significantly extend the measurement ranges. Furthermore, it could be shown that multivariate data analysis, here partial least squares regression (PLS), can improve the prediction accuracy of 'unknown' samples when used as calibration model, compared to classical, univariate data evaluation methods.
We report a novel and innovative electrochemical paper-based immunocapture assay (EPIA) to address the need for ultrasensitive detection of emerging pollutants without regulatory status and whose effects on environment and human health are not completely yet understood. In particular, we present the application of this system toward highly sensitive detection of the emerging pollutant ethinyl estradiol (EE2). The EPIA approach is based on the use of paper microzones modified with silica nanoparticles (SNs) and anti-EE2 specific antibodies for capture and preconcentration of EE2 from river water samples. After the preconcentration procedure, the paper microzones are placed onto a screen-printed carbon electrode modified with electrochemically reduced graphene (RG). The bound EE2 is subsequently desorbed adding a diluted solution of sulfuric acid on the paper microzones. Finally, recovered EE2 is electrochemically detected by OSWV. The proposed novel methodology showed an appropriate LOD and linear range for the quantification of EE2 for water samples with different origins. The nonsophisticated equipment required, the adequate recovery values obtained (from 97% to 104%, with a RSD less than 4.9%), and the appropriate LOD and linear range value (0.1 ng L−1 and 0.5−120 ng L−1, respectively) achieved by our immunocapture sensor present significant analytical figures of merit, particularly when the routine quantification of EE2 is considered. In addition, our System was based on electrochemical paper-based technology, which allows obtainment of portable, easy-to-use, inexpensive, and disposable devices. The EPIA can also serve as a general-purpose immunoassay platform applicable to quantitation of other drugs and emerging pollutants in environmental samples.
A non-invasive method to monitor the humoral immune response in mice after immunization is described. From fecal pellets of an individual mouse, a sufficient amount of active immunoglobulins or their fragments can be extracted to perform a regular examination of the status of the immune response by immunoassay. Hapten-specific antibodies from the feces of mice from three immunization trials showed very similar characteristics to those obtained from serum at a given date. Therefore, it can be suspected that some serum IgG enters the intestinal lumen and ends up in the feces, where they appear to be considerably stable. Hapten-specific IgAs were not found in the feces. Being able to analyze antibody titers in feces could be an interesting animal welfare refinement to standard practice that does not entail repeated blood sampling.
The preparation of porphyrins and phthalocyanines covalently attached onto nanostructured magnetic supports consisting of magnetite nanoparticles coated with an amorphous silica shell is reported. The easy recovery of these heterogeneous photocatalysts, just by applying an external magnetic field, allows their reuse in multiple treatment cycles. The photocatalytic activity of the non-immobilized photosensitizers and the obtained hybrid materials was evaluated in the degradation of 17 beta-estradiol, as a model organic pollutant present in water, using batch and flow mode treatment systems, assisted by visible light radiation (4 mW cm(-2)). The flow mode system potentiated the photocatalytic capacity of these novel hybrid materials. In order to improve the process, further studies based on different photocatalyst concentration and pH conditions were performed. Reuse capacity of these materials was investigated upon three photocatalytic cycles.
Commercial bead-based assays are commonly built upon polystyrene particles. The polymeric carrier can be encoded with organic dyes and has ideal material properties for cytometric applications such as low density and high refractive index. However, functional groups are conventionally integrated during polymerization and subsequent modification is limited to the reactivity of those groups. Additionally, polystyrene as the core material leads to many hydrophobic areas still being present on the beads’ surfaces even after functionalization, Rendering the particles prone to nonspecific adsorption during an application. The latter calls for several washing steps and the use of additives in (bio)analytical assays. In this contribution, we show how these limitations can be overcome by using monodisperse polystyrene (PS) core/silica (SiO2) shell particles (SiO2@PS). Two different hydrophobic BODIPY (boron−dipyrromethene) dyes were encapsulated inside a poly(vinylpyrrolidone) (PVP) -stabilized polystyrene core in different concentrations to create 5-plex arrays in two separate detection channels of a cytometer. A subsequent modification of the silica shell with an equimolar APTES/PEGS (aminopropyltriethoxysilane/polyethylene glycol silane) blend added multifunctional properties to the hybrid core/Shell microparticles in a single step: APTES provides amino groups for the attachment of a caffeine derivative (as a hapten) to create antigen-coupled microspheres; the PEG moiety effectively suppresses nonspecific binding of antibodies, endowing the surface with antifouling properties. The particles were applied in a competitive fluorescence immunoassay in suspension, and a highly selective wash-free assay for the detection of caffeine in beverages was developed as a proof of concept.
Monitoring carbamazepine in surface and wastewaters by an immunoassay based on a monoclonal antibody
(2009)
The pharmaceutical compound carbamazepine (CBZ) is an emerging pollutant in the aquatic environment and may potentially be used as a wastewater marker. In this work, an enzyme-linked immunosorbent assay (ELISA) for the detection of carbamazepine in surface and sewage waters has been developed. The heterogeneous immunoassay is based on a commercially available monoclonal antibody and a novel enzyme conjugate (tracer) that links the hapten via a hydrophilic peptide (triglycine) spacer to horseradish peroxidase. The assay achieves a limit of detection of 24 ng/L and a quantitation range of 0.05-50 µg/L. The analytical performance and figure of merits were compared to liquid chromatography-tandem mass spectrometry after solid-phase extraction. For nine Berlin surface water samples and one wastewater sample, a close correlation of results was observed. A constant overestimation relative to the CBZ concentration of approximately 30% by ELISA is probably caused by the presence of 10,11-epoxy-CBZ and 2-hydroxy-CBZ in the samples. The ELISA displayed cross-reactivities for these compounds of 83% and 14%, respectively. In a first screening of 27 surface water samples, CBZ was detected in every sample with concentrations between 0.05 and 3.2 µg/L. Since no sample cleanup is required, the assay allowed for the determination of carbamazepine with high sensitivity at low costs and with much higher throughput than with conventional methods.