Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (22)
- Zeitschriftenartikel (17)
- Vortrag (8)
- Buchkapitel (1)
- Forschungsbericht (1)
Sprache
- Englisch (45)
- Mehrsprachig (4)
Schlagworte
- Cement (49) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (8)
The existing cement and concrete standards are not capable of making full use of the current technology capacity due to strong focus on conventional concrete and thus they are not fit for the current and future challenges of construction industry. The paper highlights shortcomings with regard to the implementation of the existing standards. It can be seen that future-oriented standards are generally required to contribute to a lower-carbon footprint of the industry. These changes are significantly more relevant in sub-Saharan Africa, due to the rapidly increasing urbanisation challenge and the enormous potentials to develop lower-carbon technologies than elsewhere in the world.
Organic/inorganic mixtures were prepared from ordinary Portland cement (OPC), water (w/c 0.22), a fluorescent dye in aqueous solution (stable at alkaline pH; BAM-I), and two different comb shape polycarboxylates (PCEs), i.e., high charge (PCE-HC) and low charge (PCE-LC), respectively. Rheological and calorimetric measurements were performed prior to optical studies in order to select PCE concentrations. Absorption and fluorescence spectroscopy of the system OPC + BAM-I (CBAM-I) revealed maxima of dye BAM-I located at 645 nm and 663 nm, respectively. In presence of PCE-HC and PCE-LC, these mixtures displayed a small red shift in reflectance and a faster decrease in intensity compared to studies with CBAM-I; however, only slight differences were observed between the different PCEs. With time, all systems exhibited a decrease in intensity of BAM-I in absorption/reflectance and emission. This could be caused by dye adsorption and possibly decomposition when in contact with cement particles or hydration products.
South Africa and recently Nigeria are the only net exporter of cement in Africa, yet cements are imported into the country mainly on the basis of price competitiveness. This poses potential for scatter in the properties of the cements in the South African market as pricing seems to be the only determining factor that affects Portland cements imported. A survey of cements of grade 42.5N in the South African cement market was carried out to identify major players in the industry. The identified cements, which included four locally produced and one imported cement were then analysed for both chemical composition and physical properties in line with the Eurocode EN 196. Tests carried out include loss on ignition, chloride content, sulphate content, specific surface (Blaine), standard consistence, initial setting time, final setting time, soundness and flexural and compressive strength at 2, 7 and 28 days. The testing program was initiated as part of on-going Africa-wide cement testing competency program in partnership with BAM and PTB in Germany. The performance of the identified cements from the different local manufacturers and the imported cement were analysed and are presented in this paper. These results reveal some similarities and differences in the properties. Particularly of interest is the marked difference in the 28 days compressive strength of the cements. This paper shows that there is need for further tests across the cement industry as some of the cements failed to meet certain requirement as set by EN 196. The paper also recommends the use of proficiency testing schemes in the cement industry of the country to ensure the cement laboratories are providing results of high quality and at the same time act as a check to make sure these laboratories are not failing to meet standard requirements.
In the last years flowable concrete has become increasingly important in applications such as, for systems with highly reinforced concrete with a complicated formwork, or sprayed concrete and 3D-printing of concrete. For all these applications it is necessary to have tailored rheological properties. Rheology can be described by values of yield stress and plastic viscosity, which can be determined for example by evaluation of rheometer measurements. But for different materials various rheometers with different geometries and stirrers are being used. To see the effects from paste in concrete, it is necessary to investigate mixes of paste, mortar and concrete, stepwise. But currently there exists no device, which is calibrated for these different systems at once. Due to this fact, conventional tests such as V-funnel efflux-time and flow diameter were determined, as well as rheometer data in different cell sizes and geometries.
In this study the assessment of rheological effects in the binder on the rheology of mortar and concrete was investigated by using combination of two rheometers.
After a brief introduction into past and modern concrete, the relevance of sustainable concrete technologies is emphasised from a global perspective. In order to minimise the environmental impact of cement and concrete in the world, solutions for alternative binder materials as well as rheology and performance modifying additives are presented based on local bio-based resources.
However, the perception of bio-based constituents is typically rather negative in construction materials and its application is often limited to low-end construction. In order to show that this is not inevitable, the lecture ends with a number of case studies for the use of bio-based materials for high performance concrete applications.
The cement proficiency testing (PT) scheme was set up by the German Metrology Institute (PTB) and the Federal Institute for Materials Research and Testing (BAM) in 2012. The PT scheme was a spin-off from a European Commission and African, Caribbean and Pacific-Group of States funded project entitled SPIN – Spearhead Network for Innovative, Clean and Safe Cement and Concrete Technologies (www.spin.bam.de). The SPIN project aimed at crosslinking experts in industry and policy making bodies, with the prospect of establishing a sustainable cement and concrete construction capacity in Africa.
After a successful first pan-African proficiency testing scheme in 2012/2013, it was decided to establish the scheme permanently and independent of the SPIN project.
The main focus of setting up a testing scheme was to enable all cement testing laboratories in Africa to evaluate their competence and efficiency in cement testing and further enhance their capacity to obtain better quality products according to their environment. The acronym developed for the PT scheme is PACE-PTS (Pan-African Cement Proficiency Testing Scheme). The framework for the PT scheme was set up jointly among the organisers and the first participants. The first PT scheme was initiated in Dar Es Salaam in 2012 followed by a final workshop in Berlin in 2013. The second PT scheme began in 2014. A final workshop was organised in Dar es Salaam in 2015. The third and current scheme was started in 2016 and the final workshop is held in Yaoundé.
Sub-Saharan Africa is populated by more than half a billion people,
and rapid urbanization is creating challenges in the areas of housing,
roads, railways, power supply, dams and water pipelines —
aspects of infrastructure that are critical to the well being of the
population. This situation indicates that cement and concrete will
play a major role in the future construction technology in Africa, despite
the fact that it does not have a long-lasting tradition over most
of the continent. Although the continent is rich in natural resources
for the production of mineral binder systems, many sub-Saharan
African countries exhibit challenging boundary conditions, that have
to be well understood in order to use cement and concrete technologies
in a sustainable and reasonable way.
Concrete technology was exposed to a rapid development during the last three decades. For the longest time in its history, concrete was considered as a three component System consisting of aggregates, which are bound by the hardened cement paste consisting of hydrated cement. Traditionally, the only way of adjusting the consistency of concrete was using well adjusted aggregates and grading curves and adding excess water to the concrete, accepting that the latter in return reduces strength and durability. During the last three decades, however, concrete has developed further from a three component System towards an (at least) five component system, since the use of mineral additions and Chemical admixtures has become state of the art. Both components are able to enhance the workability, the compactability, and the density of the microstructure with effects on strength, ductility and durability, while cement can be saved in parallel. Due to reasonable use of admixtures and additions, concrete can be designed to match mechanically high performance specifications. Traditionally, cement paste was considered the weakest component in concrete. Flowever, in modern concrete a good paste composition can yield highest performance, passing the role of the mechanical bottleneck towards the aggregates.
The African cement, concrete and construction business are growing at rapid pace. The cement sales are expected to grow tremendously until 2050. The number of newly built cement plants increases dramatically and in addition more cements are being imported from outside the continent, e.g. from Turkey, Pakistan, Indonesia, and China, driven by overcapacities in the countries of origin. This causes a high number of potentials and challenges at the same time. New cement plants can operate directly at best technological state of the art and thus incorporate more sustainable technologies as well as produce new and more sustainable products such as cements blended with sustainable supplementary cementitious materials such as calcined clays, and industrial or agricultural by products. At the same time the new variety of binding agent as well as the international imports, which are driven by price considerations, make the cement market prone to quality scatter. This puts pressure on the quality control regulations and institutions to ensure safety of construction, healthy application, and environmental safety for the population.
The paper presents possible solutions to build up the rapidly increasing African cement production more sustainably than in the rest of the world as well as the related challenges and obstacles that need to be overcome. Based on experiences with a series of pan-African cement testing laboratory proficiency schemes conclusions are made on technical, regulative and political level.