Since its invention in the early 1990’s, self-consolidating concrete has never become well established in the ready-mix sectors worldwide. The reason for this can be mainly found in the fact that the sophisticated compositions are sensitive against changing environments. This lack of robustness can be attributed to the interaction between cement hydration reaction and high range water reducing agent (HRWRA). Understanding the relevant mechanisms that control the initial flow performance as well as the flow retention helps optimizing SCC mixtures that perform either steadily in one specific environment or that perform largely similarly at steadily changing environments.
This paper depicts how HRWRAs interact with clinker and hydration phases and discusses the important role of the charge density of a polycarboxylic HRWRA in the way the rheology is affected. Based on rheometric results and observations of the Vicat setting times, it is shown that increasing charge densities of the HRWRA and decreasing water to powder ratios (w/p) reduce the flow retention and have lesser retarding effect on the setting. Based on the discussion, optimization procedures for the mixture composition and the HRWRA modification are suggested to achieve optimized performance for varying environmental situations or highest robustness for specific conditions.
Selbstverdichtender Beton verhält sich unter Temperatureinfluss anders als Normalbeton, da die Rheologie neben der fortschreitenden Hydratation zusätzlich durch die von der Zeit und dem Hydratationsfortschritt abhängige Adsorption von Fließmitteln beeinflusst wird. Anhand rheometrischer Betonversuche an SVB unterschiedlicher Entwurfskonzepte mit variierter anionischer Ladungsdichte im Fließmittel wird verdeutlicht, dass mehlkornreiche SVB bei niedrigen Temperaturen sehr robust sind, während bei hohen Temperaturen mehlkornärmere Entwürfe zu bevorzugen sind. Darüber hinaus wird gezeigt, wie sich unterschiedliche Fließmittelmodifikationen in bestimmten Temperaturbereichen verhalten. Anhand des Wasser-Feststoff-Verhältnisses und des Adsorptionsverhaltens von Fließmitteln werden die maßgeblichen Prozesse erläutert und Möglichkeiten für die Entwicklung robuster Mischungen für individuelle Temperaturbereiche aufgeführt.--------------------------------------------------------------------------------------------------------------------------------------------------------------
Regarding the temperature dependent performance, self-compacting concrete (SCC) distinguishes from normal concrete, since its rheology does not only depend upon the hydration itself but supplementary upon the adsorption of superplasticizers, which is affected by the time and the hydration progress. Based on rheometric concrete investigations with different SCC mixture compositions and varied anionic charge densities of the superplasticizers, it is shown that SCC, which is rich in powder components, shows robust performance at low temperatures, while compositions with lower powder contents are favourable at high temperatures. Furthermore, the performance of different superplasticizer modifications at different temperature ranges is demonstrated. The relevant processes are explained by means of the water to powder ratio as well as the adsorption behaviour of superplasticizers, and options for the development of robust mixture compositions for individual temperature ranges are itemised.
Stabilising admixtures are commonly used additives in repair mortars and grouts. Beyond this, such type of admixture is increasingly used in concrete and other cementitious materials. In particular when fresh mortar or concrete properties have to be adjusted reliably, stabilising agents can be beneficially used to improve workability and robustness of the mixture. The mode of operation of these admixtures varies, rather affecting either the liquid phase or the solid particles in the dispersion, both causing strong interactions with the mortar or concrete system, and significant changes in their rheological behaviour. Furthermore, these are strongly affected by the environmental temperature during the casting process. In the paper the effect of temperature on the performance of stabilising agents in cementitious systems is presented and how performance changes affect fresh and hardening mortar or concrete properties. Particular attention is placed on interactions between stabilising agents and superplasticizers. Results are discussed with special focus on self-compacting concrete.
Sub-Saharan Africa is populated by more than half a billion people,
and rapid urbanization is creating challenges in the areas of housing,
roads, railways, power supply, dams and water pipelines —
aspects of infrastructure that are critical to the well being of the
population. This situation indicates that cement and concrete will
play a major role in the future construction technology in Africa, despite
the fact that it does not have a long-lasting tradition over most
of the continent. Although the continent is rich in natural resources
for the production of mineral binder systems, many sub-Saharan
African countries exhibit challenging boundary conditions, that have
to be well understood in order to use cement and concrete technologies
in a sustainable and reasonable way.
Polysaccharides provide high potential to be used as rheology modifying admixtures in mineral binder systems for the construction industry such as concrete or mortar. Since superplasticizers have become state of technology, today, concrete is more and more adjusted to flowable consistencies. This often goes along with the risk of segregation, which can be effectively avoided by adding stabilising agents supplementary to superplasticizers. Stabilising agents are typically based on polysaccharides such as cellulose, sphingan gum, or starch. Starch clearly distinguishes in its effect on rheology from other polysaccharides, mainly due to the strong influence of amylopectin on the dispersion and stabilisation of particles. Based on rheometric investigations on cementitious and limestone based dispersions with different volumetric water to solid ratios, the mode of operation of modified potato starch is explained in comparison to a sphingan gum. It is shown that the stabilising effect of starch in a coarsely dispersed system is mainly depending upon the water to solid ratio and that above a certain particle volume threshold starch mainly affects the dynamic yield stress of dispersions, while plastic viscosity is affected only to a minor degree. Sphingans operate more independent of the particle volume in a coarsely dispersed system and show significantly higher effect on the plastic viscosity than on the yield stress. In systems incorporating superplasticizers, influences of both stabilising agents on yield stress retreat into the background, while both observed polysaccharides maintain their effect on the plastic viscosity.
Self-compacting concrete typically contains a higher content of powder materials than normal concrete. Furthermore it is assumed that the use of superplasticizers yields a more homogenous microstructure in the hardened paste. Both aspects generate a very dense microstructure, which can be assumed to cause material behaviour that differs from than normal concrete when it is exposed to elevated temperatures. However, the paste volumes in SCC can vary significantly based on the mixture composition. At a low paste volumes SCC can be very similar to normal concrete at hardened state while it can vary greatly at higher paste volumes. Since the high temperature behaviour of concrete is strongly affected by the different physical behaviour of the paste and the aggregates, it is likely that the high temperature behaviour is consequently strongly affected by the ratio of these mixture components. In the present study different SCC mixtures were observed with similar mechanical properties, but with significantly differing paste to aggregate ratios. Based on observations of the heat evolution at the fire exposed surface and at different depths inside the specimens as well as based on photogrammetric observations of the spalled dimensions, the results indicate that with increasing paste volumes the heat conductivity is reduced and as a result concrete with higher paste to aggregate ratios shows less spalling.
Control chart systems are commonly used in quality management systems to keep production processes stable. The most efficient control chart systems are cumulated sums (cusum), which look at the deviations from a target value. Cusum charts react more rapidly on systematic changes in processes than other charts such as Shewhart charts, which look at the process values. The cusum method is often applied for compressive strength but it is particularly suitable if counteractions be taken immediately, like in the case of fresh concrete properties.
The present study shows that regardless of the manipulation, a steady slump flow can be achieved only by adding supplementary superplasticizer in case of loss of flow and adding stabilising agent (ST) in case of increased flow if the V-mask indicates a systematic change. A reference SCC was artificially manipulated in order to achieve either increased or reduced flowability. Arithmetic mean values and standard deviations were determined experimentally without and after taking counteractions. These parameters were used for case studies of steady SCC productions based on normally distributed random values. For the indication of a systematic change, a standard V-mask was used.
The results point out that productions with applied cusum methods were capable of keeping the slump flow deviation from the target in the order of magnitude of about 1% despite drastic manipulations, while productions without applied cusum method deviated up to 14% and more from the target slump flow value.